Preterm BirthROAMNCT04687618
Oxygen Assist Module in Preterm Infants on High Flow Nasal Cannula Support.
A study of Preterm Birth, run by South Tees Hospitals NHS Foundation Trust at 1 site in United Kingdom.
Trial summary
Oxygen treatment is common in babies born early (preterm) and requiring intensive care. Having too much or too little oxygen can increase the risk of damage to the eyes and lungs, and contribute to death or disability. Preterm infants because of their immaturity experience episodes of low oxygen levels. Read more about this study
- Who is it for?
- Ages 23 to 32 weeks
- Conditions the study is for
- Preterm Birth
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 60 participants
- Where
- 1 siteUnited Kingdom
- Study dates
- 15 Apr 2021to 30 Apr 2023
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 23 to 32 weeks
- All sexes
- No healthy volunteers
- Child
Who may be able to join
- Preterm infants {born at a gestation <33 weeks (23+0 to 32+6 weeks) }
- Receiving HFNC as respiratory support anytime during their stay in the neonatal support
Who cannot join
- Preterm infants more than equal to 33 weeks.
- Preterm infants with major congenital or chromosomal anomalies
Trial locations and contacts
1 site in 1 country.
Joe Millar contact
United Kingdom1 site, 1 recruiting
- Recruiting
James Cook University Hospital
Middlesbrough, TS4 3BW
Vrinda Nair, MBBS, M.D, FRCPCH, vrinda.nair1@nhs.net
About this study
Official title: A Randomized Control Trial of Oxygen Assist Module in Preterm Infants on High Flow Nasal Cannula Support (ROAM)
Oxygen treatment is common in babies born early (preterm) and requiring intensive care. Having too much or too little oxygen can increase the risk of damage to the eyes and lungs, and contribute to death or disability. Preterm infants because of their immaturity experience episodes of low oxygen levels. The low oxygen episodes are primarily due to pauses in their breathing (Apnoea of prematurity) and immaturity of their lung. These episodes persist for weeks to months. The lower the gestation at birth the longer the duration of these events. Studies have shown that these episodes of low oxygen saturations especially if frequent and prolonged is associated with poor developmental outcome, severe eye disease and lung disease.
Traditionally, the oxygen delivery is manually adjusted when infant has low oxygen saturation. However previous studies have shown despite the best efforts the oxygen level can only be maintained less than half of the time and nearly a one-fifth of the time infant spends in low oxygen levels and nearly one-third of the time in high oxygen levels. With advancement in the neonatal care, preterm infants tend to spend more time on non invasive respiratory support. Now it is possible to maintain oxygen level in target range by using automatic control of oxygen delivery on non invasive support. With the proposed study, we would like to study the efficacy of automatic control of oxygen delivery in reducing the time spent in very low and high oxygen levels when infants are on non invasive respiratory support namely High Flow Nasal Cannula support.
Read the detailed description
Supplemental oxygen remains by far the most commonly used 'drug' in neonatal intensive care units. The goal of oxygen therapy is to maintain normal oxygenation while minimizing hypoxemia and hypoxemia. Preterm infants are particularly vulnerable to oxygen toxicity and oxidative stress leading to retinopathy of prematurity (ROP), bronchopulmonary dysplasia (BPD), and periventricular leukomalacia (PVL). It's also well known that preterm infants experience hypoxic events which are primarily linked to cardiovascular instability and apnea of prematurity. These events vary as the infant matures. Martin R et al showed in their study that these hypoxic events peaked around 2-4 weeks and decreases by 6-8 weeks in preterm infants . Exposure to prolonged and frequent hypoxemic episodes has been associated with increased morbidity and mortality . Prolonged hypoxic events (Saturation less than 80% for more than 1 minute) have been associated with severe ROP and impaired neurodevelopmental outcome in survivors . Very high oxygen levels are equally harmful.
Peripheral oxygen saturation monitoring is standard of care in infants admitted to neonatal unit. Traditionally oxygen saturation (SpO2) targeting is carried out by manual adjustment of fraction of inspired oxygen (FiO2) by the caregiver based on the monitored oxygen saturation. However, in practice this is only partially achieved during routine care[6]. Hagadorn et al conducted a study in 14 centers and showed that preterm infants under 28 weeks' gestation receiving oxygen spent on average only 48% of the time with SpO2 within the prescribed target range, about 36% of the time above and 16% of the time with SpO2 below the target range.
Preterm infants have frequent fluctuations in SpO2 due to their cardio-respiratory instability requiring frequent adjustments of FiO2 . Consequently, these particularly vulnerable infants spend significant time with SpO2 outside intended range and are often exposed to extremes of hypoxemia and hyperoxaemia. The automatic oxygen control system continuously monitors the oxygen saturation and adjusts the oxygen delivery to maintain oxygen saturation within the target range. The safety, feasibility and efficacy of this mode of oxygen control have already been established. Automated control of FiO2 significantly improves compliance of oxygen saturation targeting and significantly reduces exposure to hypoxemia as well as hyperoxaemia. Automatic control of oxygen delivery is available in both invasive and non-invasive mode of ventilation. The HFNC Therapy is a common mode of non-invasive respiratory support in preterm infants. Oxygen Assist Module (OAM) is a system of automatic oxygen control available in the HFNC (Vapotherm Precision Flow).
Previous study looking at the efficacy of automated oxygen control with HFNC support mostly have been a crossover model and the study duration less than 48 hours . As previously mentioned, preterm infants experience hypoxic events for few weeks before cardiopulmonary maturation is established. Hence, it's important to study these events over a longer period of time. The objective of this randomized control trial is to evaluate the efficacy of OAM (Automatic oxygen Control) in reducing the extremes of oxygen saturations in preterm infants (<80% and >98%) through the entire period of HFNC respiratory support.
- Conditions
- Preterm Birth
- Being tested
- High Flow Nasal Cannula withAutomatic control of FiO2 using OAM, High Flow Nasal Cannula with manual control of FiO2
- Keywords
- Preterm, High Flow Nasal Cannula
- Medical subject headings
- Premature Birth
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
High Flow Nasal Cannula withAutomatic control of FiO2 using OAMDevice
The target oxygen saturation (SpO2) value will to be determined and set by the clinician according to specific patient needs. The target SpO2 in preterm infants is 90-95% with alarm limits at 89-96%. In automatic control of oxygen, the OAM automatically increases or decreases the FiO2 (oxygen delivery) setting on the Vapotherm Precision Flow based on pulse oximetry readings of the OAM. The target saturation will be set at 93% and the FiO2 will be adjusted by OAM to maintain the target saturation. The automated FiO2 setting can be overridden for a clinician pre-set period of time (30-120 sec) by simply manually adjusting the FiO2 on the Precision Flow. Automated control resumes after the clinicians pre-set period of time (30-120 sec) based on the current SpO2 and FiO2. The OAM utilizes a feedback control algorithm that receives a patient's oxygen saturation value from a build in pulse oximetry device (Masimo SET OEM - normal sensitivity, averaging time window set at 8 seconds).
High Flow Nasal Cannula with manual control of FiO2Device
In manual control of oxygen all FiO2 adjustments will be done by the clinical staff to maintain saturations between 90-95%. The alarm limits will be 89-96%.
| Study group | Role | What they receive |
|---|---|---|
| Automatic control of FiO2 | Experimental | Infants randomized to this arm will be monitored using automatic oxygen control system on the High Flow Nasal Cannula. When infants oxygen saturation are out of the target range the OAM module on HFNC will adjust the oxygen delivery depending on the saturation of the infant to bring the saturation in the target range. Receives: Device: High Flow Nasal Cannula withAutomatic control of FiO2 using OAM |
| Manual Control of FiO2 | Active comparator | Infants randomized to this arm will be receive oxygen delivery adjustments manually by the nursing and medical team taking care of the infants. When the infants oxygen saturation are out of the target range, the staff will manually adjust the oxygen delivery. Receives: Device: High Flow Nasal Cannula with manual control of FiO2 |
What is being measured
The primary outcome is the main question the study is designed to answer.
Proportion of time spent in extreme saturation (<80% and >98%) in preterm infants receiving HFNC as respiratory support.
The primary outcome of this study is proportion of time spent in extreme saturation (<80% and >98%) in preterm infants receiving HFNC as respiratory support.
Measured: Through study completion on an average of 3 months
Secondary outcomes (3)
Proportion of time spent in target saturation
Proportion of time spent in target saturation
Measured: Through study completion on an average of 3 months
Proportion of time spent in saturation >95%
Proportion of time spent in saturation >95%
Measured: Through the study completion on an average of 3 months
episodes of prolonged hypoxemia (SpO2 < 80% for more than 60 sec)
episodes of prolonged hypoxemia (SpO2 < 80% for more than 60 sec)
Measured: Through study completion on an average of 3 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted29 Dec 2020
- Study start15 Apr 2021
- Primary completion31 Dec 2022 (estimated)
- Study completion30 Apr 2023 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (6)Papers the sponsor has linked to this study.
- Other trials for Preterm BirthStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Model description
- Randomised Control Trial
- Masking
- None (open label)
- Enrolment
- 60 participants (estimated)
Sponsor and investigators
- Lead sponsor
- South Tees Hospitals NHS Foundation Trust
- Sponsor type
- University, hospital or other
- Collaborators
- Vapotherm, Inc.
- Responsible party
- Sponsor
- Investigators
- Vrinda Nair, Principal investigator, South Tees NHS Trust
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04687618
- Sponsor's protocol ID
- 291497
- Acronym
- ROAM
- Status last verified
- Apr 2021
- First submitted
- 1 Nov 2020
- Last updated
- 27 Apr 2021
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Stoll BJ, Hansen NI, Bell EF, Shankaran S, Laptook AR, Walsh MC, Hale EC, Newman NS, Schibler K, Carlo WA, Kennedy KA, Poindexter BB, Finer NN, Ehrenkranz RA, Duara S, Sanchez PJ, O'Shea TM, Goldberg RN, Van Meurs KP, Faix RG, Phelps DL, Frantz ID 3rd, Watterberg KL, Saha S, Das A, Higgins RD; Eunice Kennedy Shriver National Institute of Child Health and Human Development Neonatal Research Network. Neonatal outcomes of extremely preterm infants from the NICHD Neonatal Research Network. Pediatrics. 2010 Sep;126(3):443-56. doi: 10.1542/peds.2009-2959. Epub 2010 Aug 23.
PubMed 20732945Martin RJ, Wang K, Koroglu O, Di Fiore J, Kc P. Intermittent hypoxic episodes in preterm infants: do they matter? Neonatology. 2011;100(3):303-10. doi: 10.1159/000329922. Epub 2011 Oct 3.
PubMed 21986336SUPPORT Study Group of the Eunice Kennedy Shriver NICHD Neonatal Research Network; Carlo WA, Finer NN, Walsh MC, Rich W, Gantz MG, Laptook AR, Yoder BA, Faix RG, Das A, Poole WK, Schibler K, Newman NS, Ambalavanan N, Frantz ID 3rd, Piazza AJ, Sanchez PJ, Morris BH, Laroia N, Phelps DL, Poindexter BB, Cotten CM, Van Meurs KP, Duara S, Narendran V, Sood BG, O'Shea TM, Bell EF, Ehrenkranz RA, Watterberg KL, Higgins RD. Target ranges of oxygen saturation in extremely preterm infants. N Engl J Med. 2010 May 27;362(21):1959-69. doi: 10.1056/NEJMoa0911781. Epub 2010 May 16.
PubMed 20472937Reynolds PR, Miller TL, Volakis LI, Holland N, Dungan GC, Roehr CC, Ives K. Randomised cross-over study of automated oxygen control for preterm infants receiving nasal high flow. Arch Dis Child Fetal Neonatal Ed. 2019 Jul;104(4):F366-F371. doi: 10.1136/archdischild-2018-315342. Epub 2018 Nov 21.
PubMed 30464005Lal M, Tin W, Sinha S. Automated control of inspired oxygen in ventilated preterm infants: crossover physiological study. Acta Paediatr. 2015 Nov;104(11):1084-9. doi: 10.1111/apa.13137.
PubMed 26194933Nair V, Kannan Loganathan P, Lal MK, Bachman TE, Fantl R. Randomised control trial of oxygen assist module in preterm infants on high-flow nasal cannula support. Arch Dis Child Fetal Neonatal Ed. 2023 Dec 15;109(1):65-69. doi: 10.1136/archdischild-2023-325661.
PubMed 37451840
Study at a glance
From the registry record, last updated by the sponsor on 27 Apr 2021. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Randomized Control Trial of Oxygen Assist Module in Preterm Infants on High Flow Nasal Cannula Support (ROAM)
- ClinicalTrials.gov ID
- NCT04687618
- Acronym / sponsor ID
- ROAM / 291497
- Conditions
- Preterm Birth
- Keywords
- Preterm, High Flow Nasal Cannula
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 60 participants (estimated)
- Lead sponsor
- South Tees Hospitals NHS Foundation TrustUniversity, hospital or other
- Collaborators
- Vapotherm, Inc.
- Study start
- 15 Apr 2021 (actual)
- Primary completion
- 31 Dec 2022 (estimated)
- Study completion
- 30 Apr 2023 (estimated)
- First posted
- 29 Dec 2020 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Oxygen treatment is common in babies born early (preterm) and requiring intensive care. Having too much or too little oxygen can increase the risk of damage to the eyes and lungs, and contribute to death or disability. Preterm infants because of their immaturity experience episodes of low oxygen levels. The low oxygen episodes are primarily due to pauses in their breathing (Apnoea of prematurity) and immaturity of their lung. These episodes persist for weeks to months. The lower the gestation at birth the longer the duration of these events. Studies have shown that these episodes of low oxygen saturations especially if frequent and prolonged is associated with poor developmental outcome, severe eye disease and lung disease.
Traditionally, the oxygen delivery is manually adjusted when infant has low oxygen saturation. However previous studies have shown despite the best efforts the oxygen level can only be maintained less than half of the time and nearly a one-fifth of the time infant spends in low oxygen levels and nearly one-third of the time in high oxygen levels. With advancement in the neonatal care, preterm infants tend to spend more time on non invasive respiratory support. Now it is possible to maintain oxygen level in target range by using automatic control of oxygen delivery on non invasive support. With the proposed study, we would like to study the efficacy of automatic control of oxygen delivery in reducing the time spent in very low and high oxygen levels when infants are on non invasive respiratory support namely High Flow Nasal Cannula support.
Detailed description
Supplemental oxygen remains by far the most commonly used 'drug' in neonatal intensive care units. The goal of oxygen therapy is to maintain normal oxygenation while minimizing hypoxemia and hypoxemia. Preterm infants are particularly vulnerable to oxygen toxicity and oxidative stress leading to retinopathy of prematurity (ROP), bronchopulmonary dysplasia (BPD), and periventricular leukomalacia (PVL). It's also well known that preterm infants experience hypoxic events which are primarily linked to cardiovascular instability and apnea of prematurity. These events vary as the infant matures. Martin R et al showed in their study that these hypoxic events peaked around 2-4 weeks and decreases by 6-8 weeks in preterm infants . Exposure to prolonged and frequent hypoxemic episodes has been associated with increased morbidity and mortality . Prolonged hypoxic events (Saturation less than 80% for more than 1 minute) have been associated with severe ROP and impaired neurodevelopmental outcome in survivors . Very high oxygen levels are equally harmful.
Peripheral oxygen saturation monitoring is standard of care in infants admitted to neonatal unit. Traditionally oxygen saturation (SpO2) targeting is carried out by manual adjustment of fraction of inspired oxygen (FiO2) by the caregiver based on the monitored oxygen saturation. However, in practice this is only partially achieved during routine care[6]. Hagadorn et al conducted a study in 14 centers and showed that preterm infants under 28 weeks' gestation receiving oxygen spent on average only 48% of the time with SpO2 within the prescribed target range, about 36% of the time above and 16% of the time with SpO2 below the target range.
Preterm infants have frequent fluctuations in SpO2 due to their cardio-respiratory instability requiring frequent adjustments of FiO2 . Consequently, these particularly vulnerable infants spend significant time with SpO2 outside intended range and are often exposed to extremes of hypoxemia and hyperoxaemia. The automatic oxygen control system continuously monitors the oxygen saturation and adjusts the oxygen delivery to maintain oxygen saturation within the target range. The safety, feasibility and efficacy of this mode of oxygen control have already been established. Automated control of FiO2 significantly improves compliance of oxygen saturation targeting and significantly reduces exposure to hypoxemia as well as hyperoxaemia. Automatic control of oxygen delivery is available in both invasive and non-invasive mode of ventilation. The HFNC Therapy is a common mode of non-invasive respiratory support in preterm infants. Oxygen Assist Module (OAM) is a system of automatic oxygen control available in the HFNC (Vapotherm Precision Flow).
Previous study looking at the efficacy of automated oxygen control with HFNC support mostly have been a crossover model and the study duration less than 48 hours . As previously mentioned, preterm infants experience hypoxic events for few weeks before cardiopulmonary maturation is established. Hence, it's important to study these events over a longer period of time. The objective of this randomized control trial is to evaluate the efficacy of OAM (Automatic oxygen Control) in reducing the extremes of oxygen saturations in preterm infants (<80% and >98%) through the entire period of HFNC respiratory support.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
- Model description
- Randomised Control Trial
| Arm | Type | Receives |
|---|---|---|
| Automatic control of FiO2 | Experimental | Device: High Flow Nasal Cannula withAutomatic control of FiO2 using OAMInfants randomized to this arm will be monitored using automatic oxygen control system on the High Flow Nasal Cannula. When infants oxygen saturation are out of the target range the OAM module on HFNC will adjust the oxygen delivery depending on the saturation of the infant to bring the saturation in the target range. |
| Manual Control of FiO2 | Active comparator | Device: High Flow Nasal Cannula with manual control of FiO2Infants randomized to this arm will be receive oxygen delivery adjustments manually by the nursing and medical team taking care of the infants. When the infants oxygen saturation are out of the target range, the staff will manually adjust the oxygen delivery. |
Who may qualify
- Ages
- 23 to 32 weeks
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child
Key inclusion criteria (2 listed)
- Preterm infants {born at a gestation <33 weeks (23+0 to 32+6 weeks) }
- Receiving HFNC as respiratory support anytime during their stay in the neonatal support
Key exclusion criteria (2 listed)
- Preterm infants more than equal to 33 weeks.
- Preterm infants with major congenital or chromosomal anomalies
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| High Flow Nasal Cannula withAutomatic control of FiO2 using OAMThe target oxygen saturation (SpO2) value will to be determined and set by the clinician according to specific patient needs. The target SpO2 in preterm infants is 90-95% with alarm limits at 89-96%. In automatic control of oxygen, the OAM automatically increases or decreases the FiO2 (oxygen delivery) setting on the Vapotherm Precision Flow based on pulse oximetry readings of the OAM. The target saturation will be set at 93% and the FiO2 will be adjusted by OAM to maintain the target saturation. The automated FiO2 setting can be overridden for a clinician pre-set period of time (30-120 sec) by simply manually adjusting the FiO2 on the Precision Flow. Automated control resumes after the clinicians pre-set period of time (30-120 sec) based on the current SpO2 and FiO2. The OAM utilizes a feedback control algorithm that receives a patient's oxygen saturation value from a build in pulse oximetry device (Masimo SET OEM - normal sensitivity, averaging time window set at 8 seconds). | Device | Automatic control of FiO2 |
| High Flow Nasal Cannula with manual control of FiO2In manual control of oxygen all FiO2 adjustments will be done by the clinical staff to maintain saturations between 90-95%. The alarm limits will be 89-96%. | Device | Manual Control of FiO2 |
Primary outcome
Proportion of time spent in extreme saturation (<80% and >98%) in preterm infants receiving HFNC as respiratory support.
Time frame: Through study completion on an average of 3 months
The primary outcome of this study is proportion of time spent in extreme saturation (<80% and >98%) in preterm infants receiving HFNC as respiratory support.
3 secondary outcomes
Proportion of time spent in target saturation
Time frame: Through study completion on an average of 3 months
Proportion of time spent in saturation >95%
Time frame: Through the study completion on an average of 3 months
episodes of prolonged hypoxemia (SpO2 < 80% for more than 60 sec)
Time frame: Through study completion on an average of 3 months
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 27 Apr 2021.
- Background: PubMed 20732945Stoll BJ, Hansen NI, Bell EF, Shankaran S, Laptook AR, Walsh MC, Hale EC, Newman NS, Schibler K, Carlo WA, Kennedy KA, Poindexter BB, Finer NN, Ehrenkranz RA, Duara S, Sanchez PJ, O'Shea TM, Goldberg RN, Van Meurs KP, Faix RG, Phelps DL, Frantz ID 3rd, Watterberg KL, Saha S, Das A, Higgins RD; Eunice Kennedy Shriver National Institute of Child Health and Human Development Neonatal Research Network. Neonatal outcomes of extremely preterm infants from the NICHD Neonatal Research Network. Pediatrics. 2010 Sep;126(3):443-56. doi: 10.1542/peds.2009-2959. Epub 2010 Aug 23.
- Background: PubMed 21986336Martin RJ, Wang K, Koroglu O, Di Fiore J, Kc P. Intermittent hypoxic episodes in preterm infants: do they matter? Neonatology. 2011;100(3):303-10. doi: 10.1159/000329922. Epub 2011 Oct 3.
- Background: PubMed 20472937SUPPORT Study Group of the Eunice Kennedy Shriver NICHD Neonatal Research Network; Carlo WA, Finer NN, Walsh MC, Rich W, Gantz MG, Laptook AR, Yoder BA, Faix RG, Das A, Poole WK, Schibler K, Newman NS, Ambalavanan N, Frantz ID 3rd, Piazza AJ, Sanchez PJ, Morris BH, Laroia N, Phelps DL, Poindexter BB, Cotten CM, Van Meurs KP, Duara S, Narendran V, Sood BG, O'Shea TM, Bell EF, Ehrenkranz RA, Watterberg KL, Higgins RD. Target ranges of oxygen saturation in extremely preterm infants. N Engl J Med. 2010 May 27;362(21):1959-69. doi: 10.1056/NEJMoa0911781. Epub 2010 May 16.
- Background: PubMed 30464005Reynolds PR, Miller TL, Volakis LI, Holland N, Dungan GC, Roehr CC, Ives K. Randomised cross-over study of automated oxygen control for preterm infants receiving nasal high flow. Arch Dis Child Fetal Neonatal Ed. 2019 Jul;104(4):F366-F371. doi: 10.1136/archdischild-2018-315342. Epub 2018 Nov 21.
- Background: PubMed 26194933Lal M, Tin W, Sinha S. Automated control of inspired oxygen in ventilated preterm infants: crossover physiological study. Acta Paediatr. 2015 Nov;104(11):1084-9. doi: 10.1111/apa.13137.
- Derived from this study: PubMed 37451840Nair V, Kannan Loganathan P, Lal MK, Bachman TE, Fantl R. Randomised control trial of oxygen assist module in preterm infants on high-flow nasal cannula support. Arch Dis Child Fetal Neonatal Ed. 2023 Dec 15;109(1):65-69. doi: 10.1136/archdischild-2023-325661.
- Individual participant dataSharing planned: No
Related trials for Preterm Birth
Not yet recruitingPhase 1/2
Little Lungs Study
Invasive Mechanical Ventilation, Severe Respiratory Distress Syndrome
Recruiting
Effect of Support for Low-Income Mothers of Preterm Infants
Preterm Birth, Low; Birthweight, Extremely (999 Grams or Less)
Recruiting
Maximising Maternal Milk for Preterm Infant
Breastfeeding, Prematurity
Not yet recruitingObservational study
Probiotics in Preterm Babies Use & Abuse
Probiotic in Preterm Babies Use & Abuse, Uses
Recruiting
The Periviable GOALS Decision Support Tool
Pregnancy Preterm, Premature Birth
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Joe Millar contact
Vrinda Nair principal investigator
South Tees NHS Trust
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study of Preterm Birth, run by South Tees Hospitals NHS Foundation Trust at 1 site in United Kingdom.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 27 Apr 2021. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Vrinda Nair, M.D,FRCPCH (01642854874, vrinda.nair1@nhs.net), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Proportion of time spent in extreme saturation (<80% and >98%) in preterm infants receiving HFNC as respiratory support. (time frame: Through study completion on an average of 3 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT04687618, which also lists 6 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 27 Apr 2021.