Anemia, HemolyticNCT04721262
Ferumoxytol Enhanced Hyperfine Low Field Strength MRI
An observational study of Anemia, Hemolytic, run by University of Pennsylvania at 1 site in United States.
Trial summary
The purpose of this pilot study is to evaluate the feasibility of using Ferumoxytol as a contrast agent on a low field strength, portable magnetic resonance imaging (MRI) system. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Anemia, Hemolytic
- What is being tested?
- Hyperfine Portable MRI
- Type of treatment
- Injection or infusion, Medical device
- How many people
- 2 participants
- Where
- 1 siteUnited States
- Study dates
- 9 Nov 2020to 29 Aug 2022
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Subjects referred from the Hematology Oncology Department, scheduled to receive an intravenous infusion of Ferumoxytol as part of their standard of care (SOC) treatment for iron deficiency anemia will receive one Hyperfine MRI scan of the brain prior to their infusion and one Hyperfine MRI scan of the brain after their infusion.
Who may be able to join
- Age 18 years or older
- Prescribed Ferumoxytol for iron deficiency anemia
- Informed consent obtained from patient or a legally authorized representative
Who cannot join
- Contraindications to routine 1.5 T MRI evaluation, including:
- Electrical implants such as cardiac pacemakers or perfusion pumps
- Ferromagnetic implants such as aneurysm clips, surgical clips, prostheses, artificial hearts or heart valves with steel parts, metal fragments, shrapnel, tattoos near the eye, steel implants, or other irremovable ferromagnetic objects
- History of uncontrolled seizures
- Claustrophobia
- Weight greater than or equal to 400 lbs (181.4 kg)
- Pregnancy
- Inability or suspected inability to comply with the study procedures
Trial locations and contacts
1 site in 1 country.
United States1 site
Hospital of the University of Pennsylvania
Philadelphia, Pennsylvania, 19104
About this study
Official title: Evaluation of Hyperfine Low Field Strength Portable Point-of-Care Magnetic Resonance Imaging System in Patients Receiving Ferumoxytol Infusions
The purpose of this pilot study is to evaluate the feasibility of using Ferumoxytol as a contrast agent on a low field strength, portable magnetic resonance imaging (MRI) system. Participants receiving Ferumoxytol as part of routine clinical care for iron deficiency anemia will be recruited and scanned on the Hyperfine MRI system before and after their clinically scheduled intravenous infusion. Resultant images will be compared to assess signal intensity changes generated by the presence of Feromoxytol.
Read the detailed description
Ferumoxytol is a superparamagnetic iron oxide nanoparticle (SPION) preparation that was originally designed as an MRI contrast agent, but later received FDA approval as a treatment for iron deficiency anemia. Contrast agents alter MR images by changing tissue magnetic relaxation constants such as T1 and T2 (or T2*). Gadolinium-based contrast agents decrease T1 values, causing increased signal on T1-weighted images. At low field strength, T1 values are already very short so a further decrease may provide little contrast. At typical field strengths, Ferumoxytol strongly decreases T1 and also T2 (and T2*) values, increasing signal on T1-weighted images and (conversely) decreasing signal on T2-weighted images. This T2-based contrast mechanism may be maintained at lower field strength.
Patients with iron deficiency anemia are commonly prescribed Ferumoxytol periodically as part of their standard clinical care. Multiple studies have characterized the efficacy and safety of Ferumoxytol in the treatment of iron deficiency anemia. Patients prescribed Ferumoxytol for iron-deficiency anemia typically include otherwise healthy women with heavy menstrual periods, patients with inflammatory bowel disease, and patients with chronic kidney disease. Such patients make ideal candidates for characterizing the effects of Ferumoxytol on novel imaging devices by obviating a medically unnecessary injection of the contrast agent.
Contrast agents play a key role in diagnosing and managing numerous diseases. Ferumoxytol has been used to image a variety of pathologies and organs, including tumors and inflammation in the brain, liver, pancreas, and prostate. In addition to the different magnetic relaxation properties described above, Ferumoxytol has a higher molecular weight and prolonged blood pool period compared to typical gadolinium-based agents, facilitating imaging vasculature prior to the contrast agent leaking into the extravascular tissue. This has been exploited at higher field strengths and may be particularly advantageous for low field imaging that requires longer scan times. Ferumoxytol iron particles are taken up through the reticuloendothelial system and added to physiologic iron stores, rather than being excreted through the kidneys, resulting in increased plasma half-life while also avoiding concerns related to impaired renal function that sometimes arise with other contrast agents.
The Hyperfine device is a newly developed MRI unit that has multiple potential advantages over standard CT or MRI including portability, easier upkeep, open design, and ease of use. Unlike CT, the Hyperfine device does not use moving parts or X-rays to generate images. Unlike routine MRI, the Hyperfine device uses two permanent magnets with open space between and around them, rather than a super-cooled superconducting magnetic tube. In contrast to CT and routine MRI, the device can be wheeled from place to place and moved into position with the patient remaining on a gurney or hospital bed. Relative to routine MRI, the device uses a very low magnetic field strength of 64 mT compared to 1.5 T or 3 T, making it safer for patients or environments with medical devices having metallic components.
Standard images of different types are obtained on the Hyperfine device at the push of a button on an attached touch pad. Imaging protocols include those for anatomical depiction such as balance steady-state free precession (bSFFP), T1-weighted (T1W) gradient echo (GRE), and fast low-angle shot (FLASH) as well as imaging methods focused on the detection of pathology and tissue damage such as diffusion-weighted imaging (DWI), fluid attenuated inversion recovery (FLAIR), and T2-weighted (T2W) fast spin echo (FSE). However, it is not known if existing contrast agents can provide effective contrast in the Hyperfine low-field MRI.
Thus, the primary purpose of this study is to evaluate the efficacy of Ferumoxytol as a contrast agent in low-field MRI scanners. Patients who are already receiving Ferumoxytol as a treatment for iron deficiency anemia will be scanned before and after Ferumoxytol infusion. Degree of contrast enhancement in intravascular and extravascular compartments including the cerebral vasculature and the brain parenchyma will be the primary end-point for the study.
- Conditions
- Anemia, Hemolytic
- Being tested
- Hyperfine Portable MRI
- Keywords
- Anemia, Infusion, Ferumoxytol, Feraheme
- Medical subject headings
- Anemia, Hemolytic, Anemia
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Hyperfine Portable MRIDevice
The Hyperfine device is a newly developed MRI unit that has multiple potential advantages over standard CT or MRI including portability, easier upkeep, open design, and ease of use. Unlike CT, the Hyperfine device does not use moving parts or X-rays to generate images. Unlike routine MRI, the Hyperfine device uses two permanent magnets with open space between and around them, rather than a super-cooled superconducting magnetic tube. In contrast to CT and routine MRI, the device can be wheeled from place to place and moved into position with the patient remaining on a gurney or hospital bed. Relative to routine MRI, the device uses a very low magnetic field strength of 64 mT compared to 1.5 T or 3 T, making it safer for patients or environments with medical devices having metallic components.
| Study group | Role | What they receive |
|---|---|---|
| Patients prescribed Ferumoxytol for iron deficiency anemia | Patients with iron deficiency anemia are commonly prescribed Ferumoxytol periodically as part of their standard clinical care. Multiple studies have characterized the efficacy and safety of Ferumoxytol in the treatment of iron deficiency anemia. Patients prescribed Ferumoxytol for iron-deficiency anemia typically include otherwise healthy women with heavy menstrual periods, patients with inflammatory bowel disease, and patients with chronic kidney disease. Such patients make ideal candidates for characterizing the effects of Ferumoxytol on novel imaging devices by obviating a medically unnecessary injection of the contrast agent. Receives: Device: Hyperfine Portable MRI |
What is being measured
The primary outcome is the main question the study is designed to answer.
Contrast enhancement
Changes in MRI signal intensity (contrast enhancement) produced by the presence of the Ferumoxytol contrast agent will be quantified by co-registering brain MRI studies obtained before and after administration of Ferumoxytol and determining the ratio of signal intensity values between the two sets of images (post-Ferumoxytol/pre-Ferumoxytol) in regions of interest placed separately over brain parenchyma or vascular structures. Based on the magnetic properties of Ferumoxytol, this contrast ratio is expected to be greater than one for T1-weighted scans and less than one for T2- or T2*-weighted scans.
Measured: 2 thirty-five minute scans
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted22 Jan 2021
- Study start9 Nov 2020
- Primary completion29 Aug 2022
- Study completion29 Aug 2022
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Anemia, HemolyticStudies of the same condition, open and under way.
- More trials run by University of PennsylvaniaThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case only
- Time perspective
- Prospective
- Enrolment
- 2 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Pennsylvania
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Joel M. Stein, MD, PhD, University of Pennsylvania
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04721262
- Sponsor's protocol ID
- 842634
- Status last verified
- Dec 2022
- First submitted
- 2 Nov 2020
- Last updated
- 20 Dec 2022
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 20 Dec 2022. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Evaluation of Hyperfine Low Field Strength Portable Point-of-Care Magnetic Resonance Imaging System in Patients Receiving Ferumoxytol Infusions
- ClinicalTrials.gov ID
- NCT04721262
- Acronym / sponsor ID
- 842634
- Conditions
- Anemia, Hemolytic
- Keywords
- Anemia, Infusion, Ferumoxytol, Feraheme
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 2 participants (actual)
- Lead sponsor
- University of PennsylvaniaUniversity, hospital or other
- Study start
- 9 Nov 2020 (actual)
- Primary completion
- 29 Aug 2022 (actual)
- Study completion
- 29 Aug 2022 (actual)
- First posted
- 22 Jan 2021 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this pilot study is to evaluate the feasibility of using Ferumoxytol as a contrast agent on a low field strength, portable magnetic resonance imaging (MRI) system. Participants receiving Ferumoxytol as part of routine clinical care for iron deficiency anemia will be recruited and scanned on the Hyperfine MRI system before and after their clinically scheduled intravenous infusion. Resultant images will be compared to assess signal intensity changes generated by the presence of Feromoxytol.
Detailed description
Ferumoxytol is a superparamagnetic iron oxide nanoparticle (SPION) preparation that was originally designed as an MRI contrast agent, but later received FDA approval as a treatment for iron deficiency anemia. Contrast agents alter MR images by changing tissue magnetic relaxation constants such as T1 and T2 (or T2*). Gadolinium-based contrast agents decrease T1 values, causing increased signal on T1-weighted images. At low field strength, T1 values are already very short so a further decrease may provide little contrast. At typical field strengths, Ferumoxytol strongly decreases T1 and also T2 (and T2*) values, increasing signal on T1-weighted images and (conversely) decreasing signal on T2-weighted images. This T2-based contrast mechanism may be maintained at lower field strength.
Patients with iron deficiency anemia are commonly prescribed Ferumoxytol periodically as part of their standard clinical care. Multiple studies have characterized the efficacy and safety of Ferumoxytol in the treatment of iron deficiency anemia. Patients prescribed Ferumoxytol for iron-deficiency anemia typically include otherwise healthy women with heavy menstrual periods, patients with inflammatory bowel disease, and patients with chronic kidney disease. Such patients make ideal candidates for characterizing the effects of Ferumoxytol on novel imaging devices by obviating a medically unnecessary injection of the contrast agent.
Contrast agents play a key role in diagnosing and managing numerous diseases. Ferumoxytol has been used to image a variety of pathologies and organs, including tumors and inflammation in the brain, liver, pancreas, and prostate. In addition to the different magnetic relaxation properties described above, Ferumoxytol has a higher molecular weight and prolonged blood pool period compared to typical gadolinium-based agents, facilitating imaging vasculature prior to the contrast agent leaking into the extravascular tissue. This has been exploited at higher field strengths and may be particularly advantageous for low field imaging that requires longer scan times. Ferumoxytol iron particles are taken up through the reticuloendothelial system and added to physiologic iron stores, rather than being excreted through the kidneys, resulting in increased plasma half-life while also avoiding concerns related to impaired renal function that sometimes arise with other contrast agents.
The Hyperfine device is a newly developed MRI unit that has multiple potential advantages over standard CT or MRI including portability, easier upkeep, open design, and ease of use. Unlike CT, the Hyperfine device does not use moving parts or X-rays to generate images. Unlike routine MRI, the Hyperfine device uses two permanent magnets with open space between and around them, rather than a super-cooled superconducting magnetic tube. In contrast to CT and routine MRI, the device can be wheeled from place to place and moved into position with the patient remaining on a gurney or hospital bed. Relative to routine MRI, the device uses a very low magnetic field strength of 64 mT compared to 1.5 T or 3 T, making it safer for patients or environments with medical devices having metallic components.
Standard images of different types are obtained on the Hyperfine device at the push of a button on an attached touch pad. Imaging protocols include those for anatomical depiction such as balance steady-state free precession (bSFFP), T1-weighted (T1W) gradient echo (GRE), and fast low-angle shot (FLASH) as well as imaging methods focused on the detection of pathology and tissue damage such as diffusion-weighted imaging (DWI), fluid attenuated inversion recovery (FLAIR), and T2-weighted (T2W) fast spin echo (FSE). However, it is not known if existing contrast agents can provide effective contrast in the Hyperfine low-field MRI.
Thus, the primary purpose of this study is to evaluate the efficacy of Ferumoxytol as a contrast agent in low-field MRI scanners. Patients who are already receiving Ferumoxytol as a treatment for iron deficiency anemia will be scanned before and after Ferumoxytol infusion. Degree of contrast enhancement in intravascular and extravascular compartments including the cerebral vasculature and the brain parenchyma will be the primary end-point for the study.
Study design
- Observational model
- Case only
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Patients prescribed Ferumoxytol for iron deficiency anemia | – | Device: Hyperfine Portable MRIPatients with iron deficiency anemia are commonly prescribed Ferumoxytol periodically as part of their standard clinical care. Multiple studies have characterized the efficacy and safety of Ferumoxytol in the treatment of iron deficiency anemia. Patients prescribed Ferumoxytol for iron-deficiency anemia typically include otherwise healthy women with heavy menstrual periods, patients with inflammatory bowel disease, and patients with chronic kidney disease. Such patients make ideal candidates for characterizing the effects of Ferumoxytol on novel imaging devices by obviating a medically unnecessary injection of the contrast agent. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Subjects referred from the Hematology Oncology Department, scheduled to receive an intravenous infusion of Ferumoxytol as part of their standard of care (SOC) treatment for iron deficiency anemia will receive one Hyperfine MRI scan of the brain prior to their infusion and one Hyperfine MRI scan of the brain after their infusion.
Key inclusion criteria (3 listed)
- Age 18 years or older
- Prescribed Ferumoxytol for iron deficiency anemia
- Informed consent obtained from patient or a legally authorized representative
Key exclusion criteria (8 listed)
- Contraindications to routine 1.5 T MRI evaluation, including:
- Pregnancy
- Inability or suspected inability to comply with the study procedures
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Hyperfine Portable MRIThe Hyperfine device is a newly developed MRI unit that has multiple potential advantages over standard CT or MRI including portability, easier upkeep, open design, and ease of use. Unlike CT, the Hyperfine device does not use moving parts or X-rays to generate images. Unlike routine MRI, the Hyperfine device uses two permanent magnets with open space between and around them, rather than a super-cooled superconducting magnetic tube. In contrast to CT and routine MRI, the device can be wheeled from place to place and moved into position with the patient remaining on a gurney or hospital bed. Relative to routine MRI, the device uses a very low magnetic field strength of 64 mT compared to 1.5 T or 3 T, making it safer for patients or environments with medical devices having metallic components. | Device | Patients prescribed Ferumoxytol for iron deficiency anemia |
Primary outcome
Contrast enhancement
Time frame: 2 thirty-five minute scans
Changes in MRI signal intensity (contrast enhancement) produced by the presence of the Ferumoxytol contrast agent will be quantified by co-registering brain MRI studies obtained before and after administration of Ferumoxytol and determining the ratio of signal intensity values between the two sets of images (post-Ferumoxytol/pre-Ferumoxytol) in regions of interest placed separately over brain parenchyma or vascular structures. Based on the magnetic properties of Ferumoxytol, this contrast ratio is expected to be greater than one for T1-weighted scans and less than one for T2- or T2*-weighted scans.
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 20 Dec 2022.
Related trials for Anemia, Hemolytic
RecruitingObservational study
HPC Offered for PRESERVE Expansion
Bone Marrow Transplant (BMT)
RecruitingPhase 2
Efficacy and Safety of SIL-8301 for Control of Hemolysis in a Uniform Sickle Cell Disease Endotype
Sickle Cell Disease, Sickle Cell Anaemia
RecruitingPhase 2
Haplo-identical Transplantation for Severe Aplastic Anemia, Hypo-plastic MDS and PNH Using Peripheral Blood Stem Cells and Post-transplant Cyclophosphamide for GVHD Prophylaxis
Severe Aplastic Anemia (SAA), Hypo-Plastic Myelodysplastic Syndrome (MDS)
RecruitingPhase 1
Study to Evaluate the Safety and Tolerability of Escalating Doses of Fostamatinib in Subjects With Stable Sickle Cell Disease
Sickle Cell Disorders, Sickle Cell Disease
Not yet recruiting
Hypoxic Red Blood Cells in Sickle Cell Anemia
Sickle Cell Anaemia, Sickle Cell Anemia Crisis
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Anemia, Hemolytic, run by University of Pennsylvania at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 20 Dec 2022. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Contrast enhancement (time frame: 2 thirty-five minute scans). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Dec 2022.