AzTrials
AzTrials

Anemia, HemolyticNCT04721262

Ferumoxytol Enhanced Hyperfine Low Field Strength MRI

An observational study of Anemia, Hemolytic, run by University of Pennsylvania at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this pilot study is to evaluate the feasibility of using Ferumoxytol as a contrast agent on a low field strength, portable magnetic resonance imaging (MRI) system. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Anemia, Hemolytic
What is being tested?
Hyperfine Portable MRI
How many people
2 participants
Where
1 siteUnited States
Study dates
9 Nov 2020to 29 Aug 2022
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Subjects referred from the Hematology Oncology Department, scheduled to receive an intravenous infusion of Ferumoxytol as part of their standard of care (SOC) treatment for iron deficiency anemia will receive one Hyperfine MRI scan of the brain prior to their infusion and one Hyperfine MRI scan of the brain after their infusion.

Who may be able to join

  • Age 18 years or older
  • Prescribed Ferumoxytol for iron deficiency anemia
  • Informed consent obtained from patient or a legally authorized representative

Who cannot join

  • Contraindications to routine 1.5 T MRI evaluation, including:
  • Electrical implants such as cardiac pacemakers or perfusion pumps
  • Ferromagnetic implants such as aneurysm clips, surgical clips, prostheses, artificial hearts or heart valves with steel parts, metal fragments, shrapnel, tattoos near the eye, steel implants, or other irremovable ferromagnetic objects
  • History of uncontrolled seizures
  • Claustrophobia
  • Weight greater than or equal to 400 lbs (181.4 kg)
  • Pregnancy
  • Inability or suspected inability to comply with the study procedures

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Hospital of the University of Pennsylvania

    Philadelphia, Pennsylvania, 19104

Other trials in United States

About this study

Official title: Evaluation of Hyperfine Low Field Strength Portable Point-of-Care Magnetic Resonance Imaging System in Patients Receiving Ferumoxytol Infusions

The purpose of this pilot study is to evaluate the feasibility of using Ferumoxytol as a contrast agent on a low field strength, portable magnetic resonance imaging (MRI) system. Participants receiving Ferumoxytol as part of routine clinical care for iron deficiency anemia will be recruited and scanned on the Hyperfine MRI system before and after their clinically scheduled intravenous infusion. Resultant images will be compared to assess signal intensity changes generated by the presence of Feromoxytol.

Read the detailed description

Ferumoxytol is a superparamagnetic iron oxide nanoparticle (SPION) preparation that was originally designed as an MRI contrast agent, but later received FDA approval as a treatment for iron deficiency anemia. Contrast agents alter MR images by changing tissue magnetic relaxation constants such as T1 and T2 (or T2*). Gadolinium-based contrast agents decrease T1 values, causing increased signal on T1-weighted images. At low field strength, T1 values are already very short so a further decrease may provide little contrast. At typical field strengths, Ferumoxytol strongly decreases T1 and also T2 (and T2*) values, increasing signal on T1-weighted images and (conversely) decreasing signal on T2-weighted images. This T2-based contrast mechanism may be maintained at lower field strength.

Patients with iron deficiency anemia are commonly prescribed Ferumoxytol periodically as part of their standard clinical care. Multiple studies have characterized the efficacy and safety of Ferumoxytol in the treatment of iron deficiency anemia. Patients prescribed Ferumoxytol for iron-deficiency anemia typically include otherwise healthy women with heavy menstrual periods, patients with inflammatory bowel disease, and patients with chronic kidney disease. Such patients make ideal candidates for characterizing the effects of Ferumoxytol on novel imaging devices by obviating a medically unnecessary injection of the contrast agent.

Contrast agents play a key role in diagnosing and managing numerous diseases. Ferumoxytol has been used to image a variety of pathologies and organs, including tumors and inflammation in the brain, liver, pancreas, and prostate. In addition to the different magnetic relaxation properties described above, Ferumoxytol has a higher molecular weight and prolonged blood pool period compared to typical gadolinium-based agents, facilitating imaging vasculature prior to the contrast agent leaking into the extravascular tissue. This has been exploited at higher field strengths and may be particularly advantageous for low field imaging that requires longer scan times. Ferumoxytol iron particles are taken up through the reticuloendothelial system and added to physiologic iron stores, rather than being excreted through the kidneys, resulting in increased plasma half-life while also avoiding concerns related to impaired renal function that sometimes arise with other contrast agents.

The Hyperfine device is a newly developed MRI unit that has multiple potential advantages over standard CT or MRI including portability, easier upkeep, open design, and ease of use. Unlike CT, the Hyperfine device does not use moving parts or X-rays to generate images. Unlike routine MRI, the Hyperfine device uses two permanent magnets with open space between and around them, rather than a super-cooled superconducting magnetic tube. In contrast to CT and routine MRI, the device can be wheeled from place to place and moved into position with the patient remaining on a gurney or hospital bed. Relative to routine MRI, the device uses a very low magnetic field strength of 64 mT compared to 1.5 T or 3 T, making it safer for patients or environments with medical devices having metallic components.

Standard images of different types are obtained on the Hyperfine device at the push of a button on an attached touch pad. Imaging protocols include those for anatomical depiction such as balance steady-state free precession (bSFFP), T1-weighted (T1W) gradient echo (GRE), and fast low-angle shot (FLASH) as well as imaging methods focused on the detection of pathology and tissue damage such as diffusion-weighted imaging (DWI), fluid attenuated inversion recovery (FLAIR), and T2-weighted (T2W) fast spin echo (FSE). However, it is not known if existing contrast agents can provide effective contrast in the Hyperfine low-field MRI.

Thus, the primary purpose of this study is to evaluate the efficacy of Ferumoxytol as a contrast agent in low-field MRI scanners. Patients who are already receiving Ferumoxytol as a treatment for iron deficiency anemia will be scanned before and after Ferumoxytol infusion. Degree of contrast enhancement in intravascular and extravascular compartments including the cerebral vasculature and the brain parenchyma will be the primary end-point for the study.

Being tested
Hyperfine Portable MRI
Keywords
Anemia, Infusion, Ferumoxytol, Feraheme
Medical subject headings
Anemia, Hemolytic, Anemia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Hyperfine Portable MRIDevice

    The Hyperfine device is a newly developed MRI unit that has multiple potential advantages over standard CT or MRI including portability, easier upkeep, open design, and ease of use. Unlike CT, the Hyperfine device does not use moving parts or X-rays to generate images. Unlike routine MRI, the Hyperfine device uses two permanent magnets with open space between and around them, rather than a super-cooled superconducting magnetic tube. In contrast to CT and routine MRI, the device can be wheeled from place to place and moved into position with the patient remaining on a gurney or hospital bed. Relative to routine MRI, the device uses a very low magnetic field strength of 64 mT compared to 1.5 T or 3 T, making it safer for patients or environments with medical devices having metallic components.

Study groups in NCT04721262
Study groupRoleWhat they receive
Patients prescribed Ferumoxytol for iron deficiency anemiaPatients with iron deficiency anemia are commonly prescribed Ferumoxytol periodically as part of their standard clinical care. Multiple studies have characterized the efficacy and safety of Ferumoxytol in the treatment of iron deficiency anemia. Patients prescribed Ferumoxytol for iron-deficiency anemia typically include otherwise healthy women with heavy menstrual periods, patients with inflammatory bowel disease, and patients with chronic kidney disease. Such patients make ideal candidates for characterizing the effects of Ferumoxytol on novel imaging devices by obviating a medically unnecessary injection of the contrast agent.
Receives: Device: Hyperfine Portable MRI

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Contrast enhancement

    Changes in MRI signal intensity (contrast enhancement) produced by the presence of the Ferumoxytol contrast agent will be quantified by co-registering brain MRI studies obtained before and after administration of Ferumoxytol and determining the ratio of signal intensity values between the two sets of images (post-Ferumoxytol/pre-Ferumoxytol) in regions of interest placed separately over brain parenchyma or vascular structures. Based on the magnetic properties of Ferumoxytol, this contrast ratio is expected to be greater than one for T1-weighted scans and less than one for T2- or T2*-weighted scans.

    Measured: 2 thirty-five minute scans

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Jan 2021
  2. Study start9 Nov 2020
  3. Primary completion29 Aug 2022
  4. Study completion29 Aug 2022

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Prospective
Enrolment
2 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04721262
Sponsor's protocol ID
842634
Status last verified
Dec 2022
First submitted
2 Nov 2020
Last updated
20 Dec 2022
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes

Questions about this trial

What is this clinical trial studying?

An observational study of Anemia, Hemolytic, run by University of Pennsylvania at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 20 Dec 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Contrast enhancement (time frame: 2 thirty-five minute scans). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Dec 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in