Trial summary

DILAPAN-S® was FDA-approved for pre-induction cervical ripening in 2015. Since that time, there have been limited studies comparing its efficacy, safety, and patient satisfaction to other mechanical cervical ripening techniques. Read more about this study

Who is it for?
Ages 18 to 55 years, women only
What is being tested?
Foley bulb placement and DILAPAN-S® placement
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
0 participants
Where
No sites listed yet
Study dates
30 Jun 2022to 30 Jun 2022
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 55 years
  • Women only
  • No healthy volunteers
  • Adult

Who may be able to join

  • Singleton gestation. Twin gestation reduced to singleton, either spontaneously or therapeutically is not eligible unless the reduction occurred before 14 weeks 0 days gestational age.
  • Gestational age at randomization between 39 weeks and 40 weeks 6 days (based on reliable EGA defined as ultrasound performed before 14 weeks 0 days, or a certain LMP consistent with ultrasonography before 21 weeks and 0 days.)
  • Patient prefers outpatient cervical ripening
  • Patient lives within a one-hour commute from the hospital.

Who cannot join

  • Project gestational age at date of first ultrasound is > 20 weeks 6 days
  • Refusal of blood products
  • Participation in another interventional study that influences management of labor at delivery or perinatal morbidity or mortality
  • Delivery planned elsewhere at a non-Christiana site
  • Major maternal medical illness associated with increased risk for adverse pregnancy outcomes that would preclude her from an outpatient induction (e.g. any diabetes mellitus, lupus, any hypertensive disorder, cardiac disease, renal insufficiency)
  • Medical indication for induction prior to 40 weeks 5 days due to any maternal
Show all 24Show fewer
  • Heparin or low-molecular weight heparin use during the current pregnancy
  • Cerclage in current pregnancy
  • Prior uterine or cervical surgery (cesarean, myomectomy, cerclage, LEEP, cone biopsy, etc.)
  • Known HIV positivity because of modified delivery plan
  • Iodine or latex allergy
  • Fetal demise or known major fetal anomaly
  • Medical indication for induction prior to 40 weeks 5 days due to any fetal condition
  • Known oligohydramnios, defined as amniotic fluid index < 5 cm or maximal vertical pocket < 2 cm
  • Fetal growth restriction, defined as EFW < 10th percentile
  • Plan for cesarean delivery or contraindication to labor
  • Nonvertex fetal presentation
  • Placenta previa, placenta accrete, or vasa previa
  • Active genital herpes lesions
  • Cervical dilation greater than 3 cm on initial evaluation
  • Signs of labor (regular painful contractions with cervical change) on initial evaluation
  • Active vaginal bleeding greater than bloody show on initial evaluation
  • Ruptured membranes on initial evaluation
  • Non-reassuring fetal status (category II or III fetal heart rate tracing) on initial evaluation

About this study

Official title: Cervical Ripening With Foley Bulb Versus Dilapan-S at Home: a Randomized Trial

DILAPAN-S® was FDA-approved for pre-induction cervical ripening in 2015. Since that time, there have been limited studies comparing its efficacy, safety, and patient satisfaction to other mechanical cervical ripening techniques. The purpose of this trial is to perform a noninferiority randomized clinical trial comparing DILAPAN-S® to the Foley catheter for outpatient cervical ripening in term elective labor inductions, examining time spent on the labor and delivery unit, patient safety, and patient satisfaction feedback.

Read the detailed description

In 2019, Grobman et al, published the ARRIVE trial showing that labor inductions without medical indication at 39 weeks gestation are associated with improved maternal and perinatal outcomes compared to expectant management.1 In the wake of these landmark findings, labor inductions without medical indication are becoming increasingly common not only on a nation scale, but locally as well. Recent data show that labor inductions without medical indication encompass nearly one third of all inductions at Christiana Care Health System.

Labor induction can include both mechanical and pharmacological measures to ripen the cervix and stimulate uterine contractions. The ultimate challenge, which has been the focus of numerous studies to date, is to determine which mechanical and/or pharmacological products and which clinical settings are safest and most efficacious for inducing labor.

Currently, transcervical Foley catheters are the gold-standard mechanical method of cervical ripening. However, new-emerging data has shown that hygroscopic cervical dilators, traditionally used for early pregnancy termination, may be a viable alternative. DILAPAN-S® , a hygroscopic dilator composed of a synthetic hydrogel was approved by the Food and Drug Administration for cervical ripening in 2015 and has been the subject of recent investigation. In a single-center, randomized, open-label trial consisting of 419 patients, Saad et al showed that DILAPAN-S® is not inferior to the Foley catheter for pre-induction cervical ripening at term; there was no significant difference in maternal and neonatal adverse events and patients with DILAPAN-S® were more satisfied than patients with the Foley catheter as far as sleep, relaxing time, and performance of desired daily activities.2

Furthermore, in the pursuit of improving patient satisfaction with consideration of healthcare resources, studies have investigated the safety and efficacy of outpatient mechanical cervical ripening.3 Sciscione et al, showed that in a low-risk population of 1,905 patients, no adverse outcomes were associated with outpatient Foley catheter cervical ripening and patients on average avoided 9.6 hours of hospitalizations compared to the inpatient group.4 The ACOG practice bulletin on induction of labor now states that outpatient cervical ripening, particularly mechanical methods, may be appropriate in select patients.5 Based on the literature cited above, it is plausible to hypothesize that DILAPAN-S® used for outpatient cervical ripening may optimize patient satisfaction and healthcare resource utilization without compromising patient safety and efficacy. The purpose of this trial is to perform a noninferiority randomized clinical trial comparing DILAPAN-S® to the Foley catheter for outpatient cervical ripening in term elective labor inductions, examining time spent on the labor and delivery unit, patient safety, and patient satisfaction feedback.

Being tested
Foley bulb placement, DILAPAN-S® placement

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Foley bulb placementDevice

    A 16 F Foley catheter with a 30-mL balloon and stylet is inserted into the endocervical canal under direct visualization by sterile speculum exam or by digital palpation. The Foley catheter is advanced to or past the internal os, and the balloon is filled with 30-40 mL of sterile water. The catheter is then placed on genital traction by taping the end of the catheter to the medial portion of the thigh.

  • DILAPAN-S® placementDevice

    A bivalve speculum will be used to visualize and prepare the cervix with an antiseptic solution. The DILAPAN-S® (4 x 65 mm) will be inserted in the cervical canal until it traverses the internal os. As many dilators as needed to achieve the desired effect should be inserted. Specific number of pieces always depends on decision and clinical judgement of physician and indications. A gauze pad moistened with sterile water or saline may be inserted into the vagina to help keep the DILAPAN-S® in place, if needed

Study groups in NCT04739683
Study groupRoleWhat they receive
Foley bulbActive comparator16F latex or silicone Foley catheter inflated with 30-40 cc of sterile water. The catheter will be taped to the inner thigh with gentle traction.
Receives: Device: Foley bulb placement
DILAPAN-S®Active comparatorSynthetic hydrogel cervical dilator consists of the dilating part, the polypropylene handle, and the marker string. The dilating part is manufactured from an anisotropic xerogel of AQUACRYL.
Receives: Device: DILAPAN-S® placement

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Time spent on the labor and delivery unit

    Length of time spent on the labor and delivery unit, hours

    Measured: through study completion, an average of 2 years

Secondary outcomes (29)
  1. Rate of vaginal delivery

    Measured: through study completion, an average of 2 years

  2. Rate of cesarean delivery

    Measured: through study completion, an average of 2 years

  3. Indication for cesarean delivery

    Reasons for cesarean delivery include: non-reassuring fetal heart rate tracing, arrest of dilation, arrest of descent, failed induction of labor, maternal request, other

    Measured: through study completion, an average of 2 years

  4. Time from device insertion to delivery

    Time from device (Foley bulb or Dilapan) insertion to delivery (vaginal or cesarean), hours

    Measured: through study completion, an average of 2 years

  5. Rate of vaginal delivery within 24 hours of device insertion

    Measured: through study completion, an average of 2 years

  6. Rate of vaginal delivery within 36 hours of device insertion

    Measured: through study completion, an average of 2 years

  7. Time from device insertion to expulsion or extraction

    Time from device (Foley bulb or Dilapan) insertion to spontaneous expulsion or device removal, hours

    Measured: through study completion, an average of 2 years

  8. Rate of device expulsion at home

    Percentage of patients whose device (Foley bulb or Dilapan) was expelled at home

    Measured: through study completion, an average of 2 years

  9. Rate of patients that received Pitocin

    Measured: through study completion, an average of 2 years

  10. Average number of Dilapan dilator rods used

    Multiple Dilapan rods may be placed for cervical dilation. The number of rods used is at the discretion of the clinician.

    Measured: through study completion, an average of 2 years

  11. Change in Bishop score before and after mechanical cervical ripening

    Change in Bishop score from initial assessment to first exam following device expulsion/removal.

    Measured: through study completion, an average of 2 years

  12. Time from device insertion to active stage of labor

    The active stage of labor is defined as cervical dilation greater than or equal to 6cm, hours

    Measured: through study completion, an average of 2 years

  13. Rate of artificial rupture of membranes

    Measured: through study completion, an average of 2 years

  14. Rate of epidural or spinal anesthesia during labor

    Measured: through study completion, an average of 2 years

  15. Rate of analgesia needed for device insertion

    Analgesia methods may include butorphanol, neuraxial blockade, nitric oxide, etc.

    Measured: through study completion, an average of 2 years

  16. Rate of complications from device insertion

    Complications include: incidental rupture of membranes, device malfunction/breakage, vaginal bleeding (defined as gross blood apparent on glove, perineum, vagina, or within Foley catheter lumen), cervical laceration, vasovagal reaction

    Measured: through study completion, an average of 2 years

  17. Rate of tachysystole

    Defined as at least 6 contractions in 10 minutes for 2 consecutive 10-minute periods

    Measured: through study completion, an average of 2 years

  18. Rate of postpartum hemorrhage

    Defined as 1,000 mL or blood loss accompanied by signs or symptoms of hypovolemia within 24 hours after the birth process

    Measured: through study completion, an average of 2 years

  19. Rate of shoulder dystocia

    Measured: through study completion, an average of 2 years

  20. Rate of suspected intraamniotic infection

    Defined as the presence of maternal intrapartum fever and one or more of the following: maternal leukocytosis, purulent cervical drainage, or fetal tachycardia

    Measured: through study completion, an average of 2 years

  21. Rate of any serious maternal morbidity

    Serious maternal morbidities include uterine rupture, admission to an intensive care unit, and sepsis

    Measured: through study completion, an average of 2 years

  22. Rate of maternal death

    Measured: through study completion, an average of 2 years

  23. Maternal satisfaction

    A two-part maternal satisfaction survey will be administered immediately after device placement and then postpartum day one

    Measured: through study completion, an average of 2 years

  24. Rate of 1 minute Apgar score < 5

    Rate of 1 minute Apgar score less than 5

    Measured: through study completion, an average of 2 years

  25. Rate of 5 minute Apgar score < 7

    Rate of 5 minute Apgar score less than 7

    Measured: through study completion, an average of 2 years

  26. Rate of NICU admission

    Rate of neonates admitted to the NICU

    Measured: through study completion, an average of 2 years

  27. Rate of NICU admission > 48 hours

    Rate of neonates requiring NICU admission for longer than 48 hours

    Measured: through study completion, an average of 2 years

  28. NICU length of stay

    Length of NICU admission, days

    Measured: through study completion, an average of 2 years

  29. Rate of any adverse neonatal outcome

    Includes death, severe respiratory distress syndrome (defined as intubation and mechanical ventilation for a minimum of 12 hours), hypoxic-ischemic encephalopathy, seizure, culture-proven neonatal sepsis, birth trauma (bone fracture, intracranial hemorrhage, neurologic injury, retinal hemorrhage), hypotension requiring vasopressor support, receipt of total body cooling.

    Measured: through study completion, an average of 2 years

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Feb 2021
  2. Study start30 Jun 2022
  3. Primary completion30 Jun 2022
  4. Study completion30 Jun 2022

Why it stopped: Withdrawn due to another study which superseded it.

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
0 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04739683
Sponsor's protocol ID
DDD#604684
Acronym
GOHOME
Status last verified
Sep 2022
First submitted
29 Jan 2021
Last updated
21 Sep 2022
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Publications

  • Grobman WA, Rice MM, Reddy UM, Tita ATN, Silver RM, Mallett G, Hill K, Thom EA, El-Sayed YY, Perez-Delboy A, Rouse DJ, Saade GR, Boggess KA, Chauhan SP, Iams JD, Chien EK, Casey BM, Gibbs RS, Srinivas SK, Swamy GK, Simhan HN, Macones GA; Eunice Kennedy Shriver National Institute of Child Health and Human Development Maternal-Fetal Medicine Units Network. Labor Induction versus Expectant Management in Low-Risk Nulliparous Women. N Engl J Med. 2018 Aug 9;379(6):513-523. doi: 10.1056/NEJMoa1800566.

    PubMed 30089070
  • Saad AF, Villarreal J, Eid J, Spencer N, Ellis V, Hankins GD, Saade GR. A randomized controlled trial of Dilapan-S vs Foley balloon for preinduction cervical ripening (DILAFOL trial). Am J Obstet Gynecol. 2019 Mar;220(3):275.e1-275.e9. doi: 10.1016/j.ajog.2019.01.008. Epub 2019 Feb 18.

    PubMed 30790569
  • Levine LD, Sciscione AC. Foley Catheter for Outpatient Cervical Ripening: Review of the Evidence and a Proposed Model of Care. Am J Perinatol. 2019 Dec;36(14):1528-1532. doi: 10.1055/s-0038-1677473. Epub 2019 Jan 23. No abstract available.

    PubMed 30674049
  • Sciscione AC, Bedder CL, Hoffman MK, Ruhstaller K, Shlossman PA. The timing of adverse events with Foley catheter preinduction cervical ripening; implications for outpatient use. Am J Perinatol. 2014 Oct;31(9):781-6. doi: 10.1055/s-0033-1359718. Epub 2013 Dec 17.

    PubMed 24347259
  • ACOG Practice Bulletin No. 107: Induction of labor. Obstet Gynecol. 2009 Aug;114(2 Pt 1):386-397. doi: 10.1097/AOG.0b013e3181b48ef5. No abstract available.

    PubMed 19623003
  • Albers LL. The duration of labor in healthy women. J Perinatol. 1999 Mar;19(2):114-9. doi: 10.1038/sj.jp.7200100.

    PubMed 10642971

Questions about this trial

What is this clinical trial studying?

A study testing Foley bulb placement and DILAPAN-S® placement in people with Induced; Birth and Induction of Labor Affected Fetus / Newborn, run by Christiana Care Health Services.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 24 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: withdrawn, as of the sponsor's last update on 21 Sep 2022. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was withdrawn before enrolling participants, so there are no results.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Time spent on the labor and delivery unit (time frame: through study completion, an average of 2 years). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04739683, which also lists 6 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 21 Sep 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in