Coronary Artery DiseaseCONCORDNCT04761991
CMR Versus CT in Coronary Artery Disease
An observational study of Coronary Artery Disease, run by University of Leicester at 1 site in United Kingdom.
Trial summary
CONCORD is a prospective observational study evaluating the diagnostic accuracy of cardiovascular magnetic resonance (CMR) and computed tomography with fractional flow reserve (CT-FFR) in patients with suspected coronary artery disease, using invasive fractional flow reserve (FFR) as the reference standard. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Coronary Artery Disease
- What is being tested?
- CMR and CTCA with CT-FFR
- How many people
- 300 participants
- Where
- 1 siteUnited Kingdom
- Study dates
- 5 Nov 2020to 30 Nov 2025
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Patients with suspected coronary artery disease referred for invasive coronary angiography
Who may be able to join
- Patients aged ≥18 years
- Referred for invasive coronary angiography for investigation of chest pain
Who cannot join
- Recent acute coronary syndrome (< 6 months)
- Previous coronary artery bypass grafting
- Severe claustrophobia
- Absolute contraindications to CMR - those with MR conditional or safe devices will be included
- Second-/third-degree atrioventricular block
- Severe chronic obstructive pulmonary disease
Show all 11Show fewer
- Moderate-severe asthma
- Estimated glomerular filtration rate <30 ml/min/1.73m2
- Women who are pregnant, breast-feeding or of child-bearing potential( premenopausal women)
- Contraindication to iodinated contrast
- Participation in a research study involving an investigational product in the past 12 weeks
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Mo Elshibly contact
United Kingdom1 site, 1 recruiting
- Recruiting
Glenfield Hospital
Leicester, Leics, LE3 (QP
Jayanth Arnold, 0300 303 1573, jra14@le.ac.uk
Mo Elshibly, 0300 303 1573, mmme1@le.ac.uk
About this study
Official title: Comparison of Cardiovascular Magnetic Resonance and Computed Tomography With Fractional Flow Reserve in the Diagnosis of Suspected Coronary Artery Disease
CONCORD is a prospective observational study evaluating the diagnostic accuracy of cardiovascular magnetic resonance (CMR) and computed tomography with fractional flow reserve (CT-FFR) in patients with suspected coronary artery disease, using invasive fractional flow reserve (FFR) as the reference standard.
Read the detailed description
In patients with suspected coronary artery disease (CAD), CT coronary angiography (CTCA) provides excellent sensitivity and negative predictive value, enabling the safe exclusion of significant CAD. However, its positive predictive value remains suboptimal (c.50%). Undertaking additional CT-FFR improves specificity and positive predictive value, reducing unnecessary invasive coronary angiography. It has been established that CMR perfusion imaging offers excellent diagnostic accuracy for the identification of functionally significant coronary artery disease. The diagnostic performance of qualitative CMR perfusion assessment may be further enhanced by additional quantitative assessment. The purpose of this prospective observational study is to evaluate the diagnostic performance of all three modalities (CT-FFR and qualitative and quantitative CMR perfusion imaging), involving 300 patients with suspected coronary artery disease referred for invasive coronary angiography. A subset of 167 subjects will undergo an additional accelerated CMR scan for comparison. Invasively measured fractional flow reserve (FFR) will serve as the reference standard.
- Conditions
- Coronary Artery Disease
- Being tested
- CMR and CTCA with CT-FFR
- Keywords
- MRI, CT-FFR, coronary artery disease
- Medical subject headings
- Coronary Artery Disease
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
CMR and CTCA with CT-FFRDiagnostic test
multi-parametric CMR assessment and CT coronary angiography with FFR assessment
What is being measured
The primary outcome is the main question the study is designed to answer.
1. Diagnostic performance of CMR and CT-FFR
Diagnostic accuracy of CMR perfusion imaging (quantitative and qualitative analysis) and CT-FFR to determine the presence/absence of significant coronary artery disease at the subject level when compared with invasive FFR.
Measured: 6 weeks
Secondary outcomes (10)
1. Diagnostic performance of CMR and CT-FFR
- Sensitivity and specificity of CMR perfusion imaging (quantitative and qualitative analysis) and CT-FFR to determine the presence/absence of significant coronary artery disease at the subject level when compared with invasive FFR.
Measured: 6 weeks
2. Diagnostic performance of CMR and CT-FFR
- Diagnostic accuracy, sensitivity and specificity of CMR perfusion imaging (quantitative and qualitative analysis) and CT-FFR to determine the presence/absence of significant coronary artery disease at the vessel level when compared with invasive FFR.
Measured: 6 weeks
3. Diagnostic performance of CMR T1 mapping
Diagnostic accuracy, sensitivity and specificity of CMR T1 mapping using invasive FFR as the reference standard (per patient and per vessel levels).
Measured: 6 weeks
4. Diagnostic performance of hybrid imaging
Diagnostic accuracy, sensitivity and specificity of hybrid CMR/CT-FFR using invasive FFR as the reference standard (per patient and per vessel levels).
Measured: 6 weeks
Diagnostic performance of strain assessment
- Diagnostic accuracy, sensitivity and specificity of CMR strain assessment (global/segmental longitudinal/circumferential strain, mechanical dispersion) using invasive FFR as the reference standard (per patient and per vessel levels).
Measured: 6 weeks
6. Cost analysis
Cost analysis to assess the long term costs of the different diagnostic testing strategies. Healthcare costs for each testing strategy - data on resource use (staff time, scan duration, hospital days and clinic visits) will be collected during the study period.
Measured: 2 years
7. Clinical endpoints
Prediction by imaging modalities of clinical endpoints (subsequent percutaneous and/or surgical revascularisation, admissions with acute coronary syndrome and cerebrovascular accident, all-cause mortality).
Measured: 2 years
8. Subjective experience
Subjective patient scan experience for CMR and CTCA.
Measured: 1 day
9. Time duration of each scan/scan component.
Duration of each scan/scan component.
Measured: 1 day
10. Image quality
Image quality of each scan/scan component, assessed visually on a 4-point score - excellent (3), good (2), moderate (1) and poor (0).
Measured: 1 day
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted21 Feb 2021
- Study start5 Nov 2020
- Primary completion30 Nov 2025 (estimated)
- Study completion30 Nov 2025 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Coronary Artery DiseaseStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 300 participants (estimated)
Sponsor and investigators
- Lead sponsor
- University of Leicester
- Sponsor type
- University, hospital or other
- Collaborators
- HeartFlow, Inc., National Heart, Lung, and Blood Institute (NHLBI), University of Oxford, University of Glasgow
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04761991
- Sponsor's protocol ID
- 0726/258996
- Other IDs
- 1ZIAHL006242-02
- Acronym
- CONCORD
- Status last verified
- Jun 2025
- First submitted
- 17 Dec 2020
- Last updated
- 1 Jul 2025
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Shergill S, Elshibly M, Parke KS, England R, Wormleighton JV, Das I, Gulsin GS, Hothi SS, Heggie R, Wu O, Kellman P, McIntosh A, McConnachie A, Ladwiniec A, McCann GP, Arnold JR. Cardiovascular magnetic resonance versus coronary computed tomography angiography with fractional flow reserve for diagnosing obstructive coronary artery disease in higher risk patients: rationale and design of CONCORD-A prospective, single-center diagnostic accuracy study. J Cardiovasc Magn Reson. 2026 Summer;28(1):101939. doi: 10.1016/j.jocmr.2025.101939. Epub 2025 Aug 14.
PubMed 40818667
Study at a glance
From the registry record, last updated by the sponsor on 1 Jul 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Comparison of Cardiovascular Magnetic Resonance and Computed Tomography With Fractional Flow Reserve in the Diagnosis of Suspected Coronary Artery Disease
- ClinicalTrials.gov ID
- NCT04761991
- Acronym / sponsor ID
- CONCORD / 0726/258996
- Conditions
- Coronary Artery Disease
- Keywords
- MRI, CT-FFR, coronary artery disease
- Study type
- Observational
- Recruitment status
- Recruiting
- Enrolment
- 300 participants (estimated)
- Lead sponsor
- University of LeicesterUniversity, hospital or other
- Collaborators
- HeartFlow, Inc., National Heart, Lung, and Blood Institute (NHLBI), University of Oxford, University of Glasgow
- Study start
- 5 Nov 2020 (actual)
- Primary completion
- 30 Nov 2025 (estimated)
- Study completion
- 30 Nov 2025 (estimated)
- First posted
- 21 Feb 2021 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
CONCORD is a prospective observational study evaluating the diagnostic accuracy of cardiovascular magnetic resonance (CMR) and computed tomography with fractional flow reserve (CT-FFR) in patients with suspected coronary artery disease, using invasive fractional flow reserve (FFR) as the reference standard.
Detailed description
In patients with suspected coronary artery disease (CAD), CT coronary angiography (CTCA) provides excellent sensitivity and negative predictive value, enabling the safe exclusion of significant CAD. However, its positive predictive value remains suboptimal (c.50%). Undertaking additional CT-FFR improves specificity and positive predictive value, reducing unnecessary invasive coronary angiography. It has been established that CMR perfusion imaging offers excellent diagnostic accuracy for the identification of functionally significant coronary artery disease. The diagnostic performance of qualitative CMR perfusion assessment may be further enhanced by additional quantitative assessment. The purpose of this prospective observational study is to evaluate the diagnostic performance of all three modalities (CT-FFR and qualitative and quantitative CMR perfusion imaging), involving 300 patients with suspected coronary artery disease referred for invasive coronary angiography. A subset of 167 subjects will undergo an additional accelerated CMR scan for comparison. Invasively measured fractional flow reserve (FFR) will serve as the reference standard.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Patients with suspected coronary artery disease referred for invasive coronary angiography
Key inclusion criteria (2 listed)
- Patients aged ≥18 years
- Referred for invasive coronary angiography for investigation of chest pain
Key exclusion criteria (11 listed)
- Recent acute coronary syndrome (< 6 months)
- Previous coronary artery bypass grafting
- Severe claustrophobia
- Absolute contraindications to CMR - those with MR conditional or safe devices will be included
- Second-/third-degree atrioventricular block
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| CMR and CTCA with CT-FFRmulti-parametric CMR assessment and CT coronary angiography with FFR assessment | Diagnostic test | – |
Primary outcome
1. Diagnostic performance of CMR and CT-FFR
Time frame: 6 weeks
Diagnostic accuracy of CMR perfusion imaging (quantitative and qualitative analysis) and CT-FFR to determine the presence/absence of significant coronary artery disease at the subject level when compared with invasive FFR.
10 secondary outcomes
1. Diagnostic performance of CMR and CT-FFR
Time frame: 6 weeks
2. Diagnostic performance of CMR and CT-FFR
Time frame: 6 weeks
3. Diagnostic performance of CMR T1 mapping
Time frame: 6 weeks
4. Diagnostic performance of hybrid imaging
Time frame: 6 weeks
Diagnostic performance of strain assessment
Time frame: 6 weeks
6. Cost analysis
Time frame: 2 years
7. Clinical endpoints
Time frame: 2 years
8. Subjective experience
Time frame: 1 day
9. Time duration of each scan/scan component.
Time frame: 1 day
10. Image quality
Time frame: 1 day
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 1 Jul 2025.
- Derived from this study: PubMed 40818667Shergill S, Elshibly M, Parke KS, England R, Wormleighton JV, Das I, Gulsin GS, Hothi SS, Heggie R, Wu O, Kellman P, McIntosh A, McConnachie A, Ladwiniec A, McCann GP, Arnold JR. Cardiovascular magnetic resonance versus coronary computed tomography angiography with fractional flow reserve for diagnosing obstructive coronary artery disease in higher risk patients: rationale and design of CONCORD-A prospective, single-center diagnostic accuracy study. J Cardiovasc Magn Reson. 2026 Summer;28(1):101939. doi: 10.1016/j.jocmr.2025.101939. Epub 2025 Aug 14.
- Individual participant dataSharing planned: No
Related trials for Coronary Artery Disease
Not yet recruiting
Effect of Stress Ball Use During Femoral Arterial Sheath Removal After Coronary Angiography
Femoral Arterial Sheath Removal, Stress Ball
Active, not recruiting
Shockwave™ vs Surgical Endarterectomy for Calcified Severe Common Femoral Artery Stenosis: Comparison of Efficacy, Safety and Long-Term Outcomes
Common Femoral Artery Stenosis, Calcification; Heart
Not yet recruitingPhase 4
Roxadustat and Myocardial Injury After Off-Pump Coronary Artery Bypass Surgery
Coronary Artery Disease, Coronary Artery Bypass Grafting
RecruitingObservational study
Preoperative Gastric Ultrasound and Left Ventricular Function in Coronary Artery Bypass Surgery
Coronary Artery Disease, Left Ventricular Systolic Dysfunction
Active, not recruiting
The OCTOBER Trial - European Trial on Optical Coherence Tomography Optimized Bifurcation Event Reduction (OCTOBER)
Ischaemic Heart Disease, Ischemic Heart Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Mo Elshibly contact
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Coronary Artery Disease, run by University of Leicester at 1 site in United Kingdom.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 11 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 1 Jul 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Jayanth Arnold (0300 303 1573, jra14@le.ac.uk), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
1. Diagnostic performance of CMR and CT-FFR (time frame: 6 weeks). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT04761991, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 1 Jul 2025.