AzTrials
AzTrials

Respiratory FailureOxyGapNCT04772183

OxyGap : Comparison Between Different Pulse Oximeter and With the Arterial Blood Gase

An observational study of Respiratory Failure and Hypoxemia, run by Laval University at 2 sites in Canada.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The oximeter is used to monitor intensive care patients undergoing oxygen therapy. It indicates pulsed oxygen saturation (SpO2), a reflection of arterial oxygen saturation (SaO2) which enables detection of hypoxemia and hyperoxia, both deleterious state. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Respiratory Failure, Hypoxemia, Hyperoxemia
What is being tested?
SpO2 and SaO2 comparison
Type of treatment
Medical device
How many people
300 participants
Where
2 sitesCanada
Study dates
24 Mar 2021to 30 Jun 2025
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Adult, Older adult

Study population: All patient in ICU with arterial catheter already installed will be consider.

Who may be able to join

  • ≥ 18 years old
  • Patients admitted to the Intensive Care Unit
  • Artery catheter already installed

Who cannot join

  • No signal with the oximeter
  • Pigmented nails or nail polish
  • Methemoglobinemia
  • Patient in isolation (multi-resistant bacteria, C-Difficile, COVID-19…)
  • Prone position

Trial locations and contacts

2 sites in 1 country.

Canada2 sites, 2 recruiting
  • CHUM

    Montreal, Quebec, H2X0A9

    Emmanuel Charbonney

    Not yet recruiting
  • Institut Universitaire de Cardiologie et de Pneumologie de Québec

    Québec, G1V4G5

    Francois Lellouche, francois.lellouche@criucpq.ulaval.ca

    Recruiting

Other trials in Canada

About this study

Official title: OxyGap : Comparison Between Different Pulse Oximeter and With the Arterial Blood

The oximeter is used to monitor intensive care patients undergoing oxygen therapy. It indicates pulsed oxygen saturation (SpO2), a reflection of arterial oxygen saturation (SaO2) which enables detection of hypoxemia and hyperoxia, both deleterious state. Current SpO2 recommendations aim to reduce both risk of hypoxemia and hyperoxia. SpO2 is considered the 5th vital sign.

Current recommendations for SpO2 targets do not consider the variability of oximeters used in clinical practice. This variability and lack of specification represent an obstacle to an optimal practice of oxygen therapy.

Thus, this study aims to compare the SpO2 values of different oximeters (Nonin, Masimo, Philips, Nellcor) used in clinical practice with the SaO2 reference value obtained by an arterial gas in order to specify the precision and the systematic biases of the oximeters studied. This data will also make it possible to refine the recommendations concerning optimal oxygenation

Being tested
SpO2 and SaO2 comparison
Medical subject headings
Respiratory Insufficiency, Hypoxia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • SpO2 and SaO2 comparisonDevice

    Several pulse oximeter will be place on patient find few minutes before arterial blood gases.

    During an arterial blood sample, all SpO2 will be recorded

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Diffence between Nellcor SpO2 and the SaO2 value

    Diffence between Nellcor oximeter SpO2 and the SaO2 value

    Measured: During arterial blood gase sample

  2. Diffence between FreeO2 SpO2 and the SaO2 value

    Diffence between Nonin (FreeO2) oximeter SpO2 and the SaO2 value

    Measured: During arterial blood gase sample

  3. Diffence between Nonin ear clip and the SaO2 value

    Diffence between Nonin (ear sensor) oximeter SpO2 and the SaO2 value

    Measured: During arterial blood gase sample

  4. Diffence between Masimo SpO2 and the SaO2 value

    Diffence between Masimo oximeter SpO2 and the SaO2 value

    Measured: During arterial blood gase sample

  5. Diffence between Philips SpO2 and the SaO2 value

    Diffence between Philips oximeter SpO2 and the SaO2 value

    Measured: During arterial blood gase sample

  6. Diffence between Contec SpO2 and the SaO2 value

    Difffence between Contec oximeter SpO2 and the SaO2 value

    Measured: During arterial blood gase sample

  7. Diffence between Bejing choice SpO2 and the SaO2 value

    Diffence between Bejing choice oximeter SpO2 and the SaO2 value

    Measured: During arterial blood gase sample

Secondary outcomes (5)
  1. Overestimation and underestimation of SaO2

    % of pairs with overestimation and underestimation of SaO2 for each oximeter.

    Measured: During arterial blood gase sample

  2. Hypoxemia detection

    Ability to detect hypoxemia (SpO2 below 90% and PaO2 < 60 mmHg)

    Measured: During arterial blood gase sample

  3. Hyperoxemia detection

    Ability to detect hyperoxemia (SpO2 above 95% and PaO2 > 100 mmHg)

    Measured: During arterial blood gase sample

  4. Gaps between the different oximeters

    Average of the SpO2 value gaps between the different oximeters tested

    Measured: During arterial blood gase sample

  5. Finger and ear sensor comparison

    Comparison of the finger sensor and ear clip sensor for Nonin oximeter

    Measured: During arterial blood gase sample

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted26 Feb 2021
  2. Study start24 Mar 2021
  3. Primary completion31 Dec 2024 (estimated)
  4. Study completion30 Jun 2025 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
300 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04772183
Sponsor's protocol ID
2021-3624
Acronym
OxyGap
Status last verified
Jun 2024
First submitted
17 Feb 2021
Last updated
18 Jun 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

An observational study of Respiratory Failure and Hypoxemia, run by Laval University at 2 sites in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 18 Jun 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact François Lellouche (418-656-8711 ext. 3572, francois.lellouche@criucpq.ulaval.ca), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Diffence between Nellcor SpO2 and the SaO2 value (time frame: During arterial blood gase sample). The study lists 7 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Jun 2024.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in