AzTrials
AzTrials

InfectionNCT04794556

Respiratory Protection Effect of Ear-loop-type KF94 Mask

A study testing tight-fitting of KF94 mask with clip in people with Infection, run by Samsung Medical Center at 1 site in South Korea.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Ear-loop-type Korean Filter 94 masks (KF94 masks, equivalent to the N95 and FFP2) are broadly used in health care settings in Korea for the COVID-19 pandemic. However, no studies have assessed the adequacy of respiratory protection. Read more about this study

Who is it for?
Ages 18 to 65 yearsHealthy volunteers can take part
Conditions the study is for
Infection
What is being tested?
tight-fitting of KF94 mask with clip
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
1 siteSouth Korea
Study dates
1 Jan 2021to 10 Mar 2021
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 65 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • healthcare workers with experience in wearing filtering facepiece respirator working in the hospital

Who cannot join

  • Individuals with expected difficulties in wearing masks or undergoing OSHA fit tests because of factors such as a facial anomaly, lung disease, or lower back disorder

Trial locations and contacts

1 site in 1 country.

South Korea1 site
  • Samsung Medical Center

    Seoul, 06351

Other trials in South Korea

About this study

Official title: Respiratory Protection Effect of Ear-loop-type KF94 Filtering Facepiece Respirators According to the Wearing Method: A Randomized, Open-label Study

Ear-loop-type Korean Filter 94 masks (KF94 masks, equivalent to the N95 and FFP2) are broadly used in health care settings in Korea for the COVID-19 pandemic. However, no studies have assessed the adequacy of respiratory protection. In this prospective randomized open-label study, the investigators aimed to evaluate the fitting performance of ear-loop-type KF94 masks by the quantitative fit test according to the occupational safety and health administration (OSHA) protocol. In addition, by quantitatively comparing the "tight-fitting" method using a clip and the "general-fitting" method, the investigators tried to evaluate whether the tight-wearing method improves the fitting performance of KF94 masks.

Read the detailed description

Sample size: The sample size was calculated based on a pilot study of 10 participants, which examined the FF of general-fitting. The mean FF was 20.3, and the log-transformed FFs were assessed due to skewed data, which was 1.98 (standard deviation 1.34). We assumed that the FF for tight-fitting would increase by 50%, with an α value of .05, and a β error of .10 (power = 90%) for two-sided hypothesis testing. The estimated sample size calculation revealed a required sample of 24 participants. Therefore, 30 participants were enrolled to account for a 20% dropout rate.

Data analyses: Repeated-measures analysis of variance or generalized estimating equations were used to compare the FFs or passing rate of the QNFTs for the three mask types according to the wearing method. Paired t-tests or Wilcoxon signed-rank tests were used to compare the FFs according to the wearing method for each mask type. McNemar's test was used to compare the passing rate of the QNFT according to the wearing method. Bonferroni's correction was performed for all results of each subgroup analysis. SAS ver. 9.4 software (SAS Institute, Cary, NC) was used to perform all statistical analyses.

Conditions
Infection
Being tested
tight-fitting of KF94 mask with clip
Keywords
Respiratory protective devices, quantitative fit test, N95 filtering facepiece respirators, infection control, KF94 mask
Medical subject headings
Infections

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • tight-fitting of KF94 mask with clipDevice

    The general-fitting method involved wearing a mask with ear loops, and the tight-fitting method involved wearing a clip that connected ear loops on the occiput after wearing a mask according to the general method

Study groups in NCT04794556
Study groupRoleWhat they receive
Group AExperimentalParticipants were randomly assigned to groups A, B, and C to reduce learning effects according to the mask type
Receives: Device: tight-fitting of KF94 mask with clip
Group BExperimentalParticipants were randomly assigned to groups A, B, and C to reduce learning effects according to the mask type
Receives: Device: tight-fitting of KF94 mask with clip
Group CExperimentalParticipants were randomly assigned to groups A, B, and C to reduce learning effects according to the mask type
Receives: Device: tight-fitting of KF94 mask with clip

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. total fit factors(FFs) of the quantitative fit tests (QNFT) according to the wearing method of the three types of KF94 masks

    Measured: through study completion, an average of 1 year

Secondary outcomes (2)
  1. passing rate of the QNFT according to the wearing method

    Measured: through study completion, an average of 1 year

  2. total FFs after user-seal-check and real-time adjustment

    Measured: through study completion, an average of 1 year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted12 Mar 2021
  2. Study start1 Jan 2021
  3. Primary completion10 Mar 2021
  4. Study completion10 Mar 2021

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Prevention
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
30 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04794556
Sponsor's protocol ID
KF94 mask
Status last verified
Mar 2021
First submitted
8 Mar 2021
Last updated
15 Mar 2021
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Yang HJ, Yoon H, Kang SY, Lee G, Park JE, Kim T, Lee SU, Hwang SY, Cha WC, Shin TG, Jo IJ. Respiratory Protection Effect of Ear-loop-type KF94 Masks according to the Wearing Method in COVID-19 Pandemic: a Randomized, Open-label Study. J Korean Med Sci. 2021 Jul 19;36(28):e209. doi: 10.3346/jkms.2021.36.e209.

    PubMed 34282608

Questions about this trial

What is this clinical trial studying?

A study testing tight-fitting of KF94 mask with clip in people with Infection, run by Samsung Medical Center at 1 site in South Korea.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 15 Mar 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

total fit factors(FFs) of the quantitative fit tests (QNFT) according to the wearing method of the three types of KF94 masks (time frame: through study completion, an average of 1 year). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04794556, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Mar 2021.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in