AzTrials
AzTrials

Coronary Artery DiseasePhase 4NCT04802681

Pressure Guidewire Comparison

A Phase 4 study testing FFR-measurement with different pressure guidewires in people with Coronary Artery Disease and Myocardial Ischemia, run by Lokien van Nunen at 1 site in Netherlands.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Fractional flow reserve (FFR) is the current gold standard for correct decision making with respect to revascularization in the catheterization laboratory. FFR is measured by using a pressure guidewire equipped with a pressure sensor, positioned distal to the stenosis under investigation. Read more about this study

Who is it for?
Ages 18 to 80 years
Conditions the study is for
Coronary Artery Disease, Myocardial Ischemia
What is being tested?
FFR-measurement with different pressure guidewires
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
50 participants
Where
1 siteNetherlands
Study dates
1 Dec 2021to 19 Jan 2023
Phase
Phase 4
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age 18-80 years
  • Scheduled to undergo invasive FFR measurement
  • Coronary artery lesions located in the proximal or mid part of the coronary artery
  • Reference diameter of at least 2.0mm

Who cannot join

  • Severe aortic valve stenosis
  • known conduction disturbances (second- or third-degree AV block)
  • acute myocardial infarction (CK >1,000 U/L less than 5 days ago)
  • bradycardia (less than 45 beats/min)
  • severe hypotension
  • extremely tortuous or calcified coronary arteries precluding FFR measurement
Show all 9Show fewer
  • history of severe asthma
  • pregnancy
  • inability to provide informed consent.

Trial locations and contacts

1 site in 1 country.

Netherlands1 site
  • Catharina Hospital

    Eindhoven, North Brabant, 5623EJ

Other trials in Netherlands

About this study

Official title: Piezo-electric Versus Open Wire Pressure Guidewires for FFR Measurements: Comparison of Two Commercially Available Pressure Wires

Fractional flow reserve (FFR) is the current gold standard for correct decision making with respect to revascularization in the catheterization laboratory. FFR is measured by using a pressure guidewire equipped with a pressure sensor, positioned distal to the stenosis under investigation. A newly developed pressure wire using open wire technology has recently become commercially available. The purpose of this study is to evaluate whether the Wirecath pressure guidewire can be used as standard pressure guidewire.

The effectiveness of the device will be investigated by comparing Wirecath FFR measurements with the measurements of another regular sensor-tipped pressure guidewires during simultaneous FFR measurements in the same vessel.

Read the detailed description

FFR is a lesion-specific pressure-derived index of functional severity, defined as the maximum myocardial blood flow in the presence of an epicardial stenosis compared with the maximum flow in the hypothetical absence of the stenosis. FFR is measured by advancing a pressure guidewire into the coronary artery distal to the lesion under investigation and maintained in that position. Distal coronary pressure (Pd) and aortic pressure (Pa) are measured simultaneously while inducing steady state maximum hyperemia. FFR is defined as the lowest value of Pd/Pa achieved during maximum hyperemia. An FFR value = or < 0.80 indicates the presence of myocardial ischemia and indicates PCI is warranted.

Existing 0.014" wires with pressure measurement capabilities have been available for more than 20 years. Improvements have been done over time, but they are still regarded as inferior to ordinary guidewires when it comes to maneuverability and general guidewire properties. This is attributed to the microelectronics that are needed to facilitate the pressure measurements in these wires. These existing wires also have issues with signal stability which is often referred to as 'drift'. Drift is an electronical phenomenon that leads to a slow progressive change in the pressure value over time. a not entirely reliable signal quality.

A relatively new pressure guidewire, Wirecath, is an equivalent device to the currently commercially available pressure guidewires. In comparative bench tests it has shown very good maneuverability. Moreover due to the 'open wire' technology (and thus lack of microelectronics throughout the wire), the Wirecath has very stable signal properties and is, according to physical law and bench testing, immune against a hydrostatic error and less affected by drifting of the signal, which are limitations with current pressure guidewires.

This study is designed to examine and compare the pressure measurements of two commercially available pressure guidewires (Abbott and Cavis Technologies) by simultaneously measuring FFR in the same coronary artery with two different pressure guidewires.

Being tested
FFR-measurement with different pressure guidewires
Keywords
Fractional Flow Reserve, Pressure wire, Drift
Medical subject headings
Coronary Artery Disease, Myocardial Ischemia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • FFR-measurement with different pressure guidewiresDevice

    Measuring FFR with different pressure guidewires

Study groups in NCT04802681
Study groupRoleWhat they receive
Wirecath - PressureWire XOtherPatients will undergo simultaneous FFR measurements with the Wirecath and PressureWire X simultaneously.
Receives: Device: FFR-measurement with different pressure guidewires

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. FFR

    To compare the pressure signals measured by the different available pressure guidewires, specifically the FFR value

    Measured: During catheterization

  2. Hydrostatic error

    To assess the occurrence of hydrostatic errors when using sensor-tipped wires

    Measured: During catheterization

  3. Drift

    To assess the occurrence of drift between the different pressure guidewires

    Measured: During catheterization

Secondary outcomes (2)
  1. Signal quality

    To assess signal quality and stability between the different pressure guidewires

    Measured: During catheterization

  2. Maneuverability

    To assess maneuverability and handling of the different pressure guidewires

    Measured: During catheterization

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted17 Mar 2021
  2. Study start1 Dec 2021
  3. Primary completion19 Jan 2023
  4. Study completion19 Jan 2023

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 4
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Model description
This study is a prospective single center randomized controlled trial of FFR measurements comparing two commercially available pressure guidewires in consecutive patients undergoing routine FFR measurements in the catheterization laboratory.
Masking
None (open label)
Enrolment
50 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04802681
Sponsor's protocol ID
PW-COMPARE
Status last verified
Jul 2023
First submitted
15 Mar 2021
Last updated
17 Jul 2023
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: There is no plan to make individual (non-anonymized) participant data available to others.

Publications

  • Eerdekens R, Tonino PAL, Zimmermann FM, Teeuwen K, Vlaar PJ, de Waard GA, van Royen N, van Nunen LX. Fluid-filled versus sensor-tipped pressure guidewires for FFR and Pd/Pa measurement; PW-COMPARE study. Int J Cardiol. 2024 Jul 1;406:131998. doi: 10.1016/j.ijcard.2024.131998. Epub 2024 Mar 28.

    PubMed 38555057
  • Ramunddal T, Dworeck C, Torild P, Andreen S, Gan LM, Hirlekar G, Ioanes D, Myredal A, Odenstedt J, Petursson P, Pylova T, Topel F, Volz S, Hilmersson M, Redfors B, Angeras O. Safety and Feasibility Using a Fluid-Filled Wire to Avoid Hydrostatic Errors in Physiological Intracoronary Measurements. Cardiol Res Pract. 2024 Jan 2;2024:6664482. doi: 10.1155/2024/6664482. eCollection 2024.

    PubMed 38204600

Questions about this trial

What is this clinical trial studying?

A Phase 4 study testing FFR-measurement with different pressure guidewires in people with Coronary Artery Disease and Myocardial Ischemia, run by Lokien van Nunen at 1 site in Netherlands.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 17 Jul 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

FFR (time frame: During catheterization). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04802681, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Jul 2023.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in
Pressure Guidewire Comparison (NCT04802681) | AzTrials