Error, RefractiveNCT04816266

Comparative Study in Measuring Anterior Chamber Depth

An observational study of Error, Refractive, run by Assiut University.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Measuring parameters of anterior segment of the eye accurately is important for diagnosing variety of diseases and for cataract surgeries, glaucoma, refractive surgeries and post-operative follow-up. One of the anterior segment parameters is the anterior chamber depth. Read more about this study

Who is it for?
Ages 18 to 40 years
Conditions the study is for
Error, Refractive
What is being tested?
Iol master and Pentacam
Type of treatment
Medical device
How many people
50 participants
Where
No sites listed yet
Study dates
1 Apr 2021to 1 Apr 2023
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 40 years
  • All sexes
  • Adult

Study population: People between eighteen and forty years seeking for refractive surgery

Who may be able to join

  • presenting for glasses
  • asking for refractive surgery

Who cannot join

  • severe corneal scarring or opacity
  • patients with corneal dystrophy
  • patients with keratoconus
  • patients with previous ocular surgery
  • patients with ocular trauma
  • patients with uveitis

About this study

Official title: Comparative Study Between Pentacam and IOL Master in Measuring Anterior Chamber Depth

Measuring parameters of anterior segment of the eye accurately is important for diagnosing variety of diseases and for cataract surgeries, glaucoma, refractive surgeries and post-operative follow-up. One of the anterior segment parameters is the anterior chamber depth.

The anterior chamber depth (ACD) measurement provides valuable information in different fields in ophthalmology. Firstly, it is important for the new theoretical biometric formulas used to calculate the power of intraocular lenses (IOLs) .Secondly, phakic IOL implantation requires precise ACD measurement for both surgical planning and IOL power calculation. Thirdly, the ACD is also implicated as a screening risk factor for glaucoma. Additionally, precise ACD measurement is thought to be important to the accurate determination of the optic zone ablation diameter for keratorefractive surgery, as well as for the analysis of postoperative ACD changes.

Different technologies are used in measurement of the anterior chamber depth Such as pentacam and iol maste

Read the detailed description

IOL master :

Optical biometry by the IOL Master was introduced in the United Kingdom in 1999.Its technology is based on laser interfer-ometry with partial coherent light, termed as Partial Coherence Interferometry (PCI).The device uses the principle of PCI to measure the axial length of the eye.While uses a slit-beam photo-graphic technique for ACD measurements For keratometry measurement, six light spots are projected hexagonally on the cornea .The device records the reflection of these images measuring the separation of the opposite pairs of light spots and calculating the corneal radii and toroidal surface curvature. The mean of the taken measurements is considered the corneal power . The displayed K1 and K2 represent the average keratometry values at two major perpendicular meridians .For ACD measurement, the IOL Master directs a slit beam of light 0.7mm wide through the anterior segment at an angle of 38º to the visual axis.The internal software measures the distance between anterior pole of the cornea and the anterior surface of the lens to calculate the ACD . The device takes five ACD measurements in rapid succession; the mean of these readings are taken as the ACD value . For WTW measurement, a digital grey-scale photograph of the anterior surface of the eye is taken after focusing on the iris. The limbus is then detected automatically and the WTW distance is measured

Pentacam :

The Pentacam obtains images of the anterior segment by a rotating Scheimpflug blue Light Emitting Diode (LED) with a wavelength of 475nm. It acquires 50 images in a duration of approximately two seconds. It extracts about 2,760 true elevation points from the obtained images which in turn generates 1 38,000 true elevation points for the both front and back corneal surfacesand from limbus to limbus, including the central part of the cornea . There for, it calculates k-readings of the cornea. The Pentacam HR calculates ACD from the corneal endothelial layer along a line from the apex of the cornea to the anterior surface of the lens . Horizontal WTW was measured by manual placement of callipers on the Scheimpflug image of the horizontal plane of the examined eye; callipers are placed on the corneo-scleral junction then a line is automat-ically drawn between the two points . The length of this line represents the WTW value

Being tested
Iol master, Pentacam
Medical subject headings
Refractive Errors

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Iol masterDevice

    Iol master measures the distance between anterior pole of the cornea and the anterior surface of the lens to calculate the anterior chamber depth

  • PentacamDevice

    The Pentacam HR calculates Anterior chamber depth from the corneal endothelial layer along a line from the apex of the cornea to the anterior surface of the lens

Study groups in NCT04816266
Study groupRoleWhat they receive
Myopic patientsNot described
Receives: Device: Iol master; Device: Pentacam
Hypermetropic patientsNot described
Receives: Device: Iol master; Device: Pentacam
Emmetropic peopleNot described
Receives: Device: Iol master; Device: Pentacam

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Comparison between values of anterior chamber depth obtained by different devices

    Measuring Anterior chamber depth by Pentacam and iol master in eyes with different refractive errors

    Measured: One year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted25 Mar 2021
  2. Study start1 Apr 2021 (estimated)
  3. Primary completion1 Apr 2022 (estimated)
  4. Study completion1 Apr 2023 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Cross-sectional
Enrolment
50 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04816266
Sponsor's protocol ID
Anterior chamber depth
Status last verified
Mar 2021
First submitted
23 Mar 2021
Last updated
25 Mar 2021
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

An observational study of Error, Refractive, run by Assiut University.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 25 Mar 2021. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Comparison between values of anterior chamber depth obtained by different devices (time frame: One year). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 25 Mar 2021.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in