Trial summary

The ability to assess intravascular volume is an essential part of perioperative care: insufficient intravascular volume can result in decreased oxygen delivery to tissues and organ dysfunction, while fluid overload can contribute to the development of oedema, organ dysfunction, respiratory failure and healing defect. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Surgical Procedure, Unspecified
What is being tested?
Transthoracic echocardiogram and Clear Sight system
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
53 participants
Where
1 siteBelgium
Study dates
25 Jun 2021to 9 Nov 2021
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • All patients of the CHU Brugmann hospital, who have given their consent, aged over 18 years, with a sinus rhythm, requiring a surgical procedure that allows obtaining high quality TTE imaging without pain and discomfort.
  • Examples of such surgeries are:
  • Orthopaedic surgery: interventions of upper limbs.
  • Stomatology: dental extractions
  • Gastroenterology: oesophagus gastroscopy
  • Maxillo-facial surgery: septoplasties, rhinoplasties, Le Fort surgeries
Show all 9Show fewer
  • ENT surgery: thyroidectomy, sleep endoscopies
  • Gynaecology: hysteroscopy, voluntary terminations of pregnancy
  • Ophthalmic surgery

Who cannot join

  • Refusal to participate to the study
  • suboptimal image acquisition
  • atrial fibrillation, patients with 6 or more extra systoles per minute
  • cardiac valvular pathologies
  • TTE imaging causing pain and/or discomfort to the patient
  • surgeries that don't allow obtaining high quality imaging, elevated intra-abdominal pressure.

Trial locations and contacts

1 site in 1 country.

Belgium1 site
  • CHU Brugmann

    Brussels, 1020

Other trials in Belgium

About this study

The ability to assess intravascular volume is an essential part of perioperative care: insufficient intravascular volume can result in decreased oxygen delivery to tissues and organ dysfunction, while fluid overload can contribute to the development of oedema, organ dysfunction, respiratory failure and healing defect.

At the present state, there are many different methods of interpreting intravascular circulating blood volume. Non-invasive techniques such as the Clear Sight System, and the transthoracic echocardiogram (TTE) have been proposed as non-invasive methods to assess patient' blood volume.

The aim of this study is to assess whether the measure of the inferior vena cava (IVC) in the trans-hepatic window is as reliable as in the subcostal window to determine fluid responsiveness in perioperative patients. In this study, preload increase will be obtained through passive leg raising. Sensibility and specificity of the two echocardiographic approaches to predict fluid responsiveness will be compared while using the subcostal window as the "gold standard". The effect of passive leg elevation on patient's cardiac output response will be assessed with two different non-invasive techniques: the Clear Sight system and the TTE.

Read the detailed description

The ability to assess intravascular volume is an essential part of perioperative care: insufficient intravascular volume can result in decreased oxygen delivery to tissues and organ dysfunction, while fluid overload can contribute to the development of oedema, organ dysfunction, respiratory failure and healing defect.

Assessment of the volume status in perioperative patients relies on two important concepts: euvolemia and fluid responsiveness.

Euvolemia describes a state of adequate circulating blood volume that allows suitable filling of the cardiac chambers making possible for the heart to produce a cardiac output that meets the peripheral oxygen demand.

Fluid responsiveness describes the ability of the heart to adapt blood flow in response to preload increase.

As euvolemia is the ultimate goal of fluid administration then evaluating fluid responsiveness reflects the process of working toward establishing euvolemia.

At the present state, there are many different methods of interpreting intravascular circulating blood volume: those related to pressures measurements: the central venous pressure (CVP), the pulmonary artery occluded pressure (PAOP), and those related to cardiac output measurements like thermodilution and pulse contour techniques. It is worth noting that all these are invasive methods that expose patients to a series of possible side effects such as: pneumothorax, infections, hematomas and vascular lesions. Non-invasive techniques such as the Clear Sight System, and the transthoracic echocardiogram (TTE) have been proposed as non-invasive methods to assess patient' blood volume.

TTE is a widely used and validated imaging technique which involves the study of the heart and great vessels through multiple examination windows.

In particular, the subcostal window represents the gold standard for evaluating the diameter of the inferior vena cava (IVC) and its compliance, allowing the physician to obtain valuable information on the volume status of patients: several studies have reported that these measurements could predict accurately the hemodynamic response of patient to a change in cardiac preload. However, acquiring images in the subcostal window can be, in some cases, difficult or impossible due to the presence of drainages or surgical wounds; in such cases an alternative could be represented by the trans-hepatic window which, at the best of the investigator's knowledge, it has never been validated in the literature.

The Clear Sight System is a non-invasive blood pressure (BP) monitoring system, where the CO is determined analysing the photo-plethysmography curve by a miniaturized pressure cuff and infrared LEDs.

Its main advantage is to assess CO continuously in a completely non-invasive way, following its variations and thereby contributing to the detection of hypovolaemia. Other visualized parameters are: the stroke volume (SV), the systemic vascular resistance (SVR) as well as the BP and the heart rate (HR).

Passive leg raising (PLR) is a test developed to predict patient's hemodynamic response to increase preload without any fluid administration. Raising the patient from a semi-recumbent position to a position with the head at 0° and the legs raised to a 45° angle is associated with about 300 ml of blood volume mobilization from the lower limbs and splanchnic territory to the central compartment resulting in increased venous return to the heart. This manoeuvre provokes a preload increase to which patients could respond with (responder) or without (non-responders) an augmentation of their cardiac output.

The aim of this study is to assess whether the measure of the IVC in the trans-hepatic window is as reliable as in the subcostal window to determine fluid responsiveness in perioperative patients. In this study, preload increase will be obtained through passive leg raising. Sensibility and specificity of the two echocardiographic approaches to predict fluid responsiveness will be compared while using the subcostal window as the "gold standard". The effect of passive leg elevation on patient's cardiac output response will be assessed with two different non-invasive techniques: the Clear Sight system and the TTE.

Being tested
Transthoracic echocardiogram, Clear Sight system

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Transthoracic echocardiogramDevice

    Transthoracic echocardiogram (TTE) is a widely used and validated imaging technique which involves the study of the heart and great vessels through multiple examination windows. In particular, the subcostal window represents the gold standard for evaluating the diameter of the inferior vena cava (IVC) and its compliance, allowing the physician to obtain valuable information on the volume status of patients. Acquiring images in the subcostal window with a transthoracic echocardiogram (TTE) can be, in some cases, difficult or impossible due to the presence of drainages or surgical wounds: in such cases an alternative could be represented by the trans-hepatic window. This has not been validated in the scientific litterature.

  • Clear Sight systemDevice

    The Clear Sight System is a non-invasive blood pressure (BP) monitoring system, where the CO is determined analysing the photo-plethysmography curve by a miniaturized pressure cuff and infrared LEDs.

    Its main advantage is to assess CO continuously in a completely non-invasive way, following its variations and thereby contributing to the detection of hypovolaemia. Other visualized parameters are: the stroke volume (SV), the systemic vascular resistance (SVR) as well as the BP and the heart rate (HR).

Study groups in NCT04866095
Study groupRoleWhat they receive
SurgeryExperimentalAll patients, who have given their consent, aged over 18 years, with a sinus rhythm, requiring a surgical procedure that allows obtaining high quality transthoracic echocardiogram imaging without pain and discomfort.
Receives: Device: Transthoracic echocardiogram; Device: Clear Sight system

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Difference of sensitivity between the trans-hepatic window versus the subcostal window with TTE

    Comparison of the sensitivity of both the trans-hepatic window and the subcostal window to predict the cardiac output response by transthoracic echocardiogram (TTE) to passive leg raising.

    Measured: 20 minutes

  2. Difference of specificity between the trans-hepatic window versus the subcostal window with TTE

    Comparison of the specificity of both the trans-hepatic window and the subcostal window to predict the cardiac output response by transthoracic echocardiogram (TTE) to passive leg raising.

    Measured: 20 minutes

Secondary outcomes (5)
  1. Difference of sensitivity between the trans-hepatic window versus the subcostal window with the Clear Sight system

    Comparison of the sensitivity and specificity of both the trans-hepatic window and the subcostal window to predict the cardiac output response (with the Clear Sight system) to passive leg raising.

    Measured: 20 minutes

  2. Difference of specificity between the trans-hepatic window versus the subcostal window with the Clear Sight system

    Comparison of the sensitivity and specificity of both the trans-hepatic window and the subcostal window to predict the cardiac output response (with the Clear Sight system) to passive leg raising.

    Measured: 20 minutes

  3. Right atrial pressure (RA)- trans-hepatic window

    Evaluation of the estimation of RA pressure obtained with the trans-hepatic and sub-costal approaches

    Measured: 20 minutes

  4. Right atrial pressure (RA) - subcostal window

    Evaluation of the estimation of RA pressure obtained with the trans-hepatic and sub-costal approaches

    Measured: 20 minutes

  5. Cardiac output

    Cardiac output calculated by: CO= sub-Aortic Velocity Time Integral (sAoVTI) × heart rate in beats per minute (bpm) × left ventricular outflow track (LVOT)

    Measured: 20 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Apr 2021
  2. Study start25 Jun 2021
  3. Primary completion30 Oct 2021
  4. Study completion9 Nov 2021

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
53 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04866095
Sponsor's protocol ID
CHUB-WICAVE
Status last verified
Nov 2021
First submitted
26 Apr 2021
Last updated
10 Nov 2021
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Transthoracic echocardiogram and Clear Sight system in people with Surgical Procedure, Unspecified, run by Brugmann University Hospital at 1 site in Belgium.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 9 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 10 Nov 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Belgium. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Difference of sensitivity between the trans-hepatic window versus the subcostal window with TTE (time frame: 20 minutes). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Nov 2021.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in