Arrhythmias, CardiacSAFE-DX-HomeNCT04869527
Full Early Atrial Diagnostics in Single Chamber ICD Patients Using the DX Lead and Home Monitoring in Brazil.
An observational study of Arrhythmias, Cardiac, run by Biotronik SE & Co. KG at 2 sites in Brazil.
Trial summary
To demonstrate the value and benefits of BIOTRONIK's exclusive DX technology in assessing the incidence of supraventricular arrhythmias, mainly atrial fibrillation (AF), in patients with an indication for single chamber ICDs. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Arrhythmias, Cardiac
- What is being tested?
- BIOTRONIK ICDs with DX Technology
- Type of treatment
- Medical device
- How many people
- 56 participants
- Where
- 2 sitesBrazil
- Study dates
- 24 Nov 2021to 31 Jul 2025
- How long will I take part?
- 12 Months
- Phase
- Observational
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Patients requiring an ICD implant
Who may be able to join
- Indication for implanting of a single chamber ICD (primary or secondary prevention) according to current guidelines;
- Sustained sinus rhythm as the current prevalent atrial rhythm;
- Planned de novo implantation with a BIOTRONIK single chamber DX ICD system;
- Patient is able to understand the nature of study and to provide written informed consent;
- Patient is willing and able to perform all follow up visits at the study site;
- Patient is willing and able to use the CardioMessenger and accepts the BIOTRONIK Home Monitoring concept.
Who cannot join
- Age < 18 years
- Any limitation to contractual capability;
- Female patients who are pregnant or breast feeding or planning pregnancy during the course of the study;
- Known active malignant disease or recovered from malignant disease within 2 years prior to enrollment;
- Life expectancy < 2 years;
- Patient is participating in any other interventional clinical investigation.
Trial locations and contacts
2 sites in 1 country.
Brazil2 sites
Santa Casa de Misericórdia de Porto Alegre - Brugada Institute
Porto Alegre, Rio Grande do Sul, 90020-090
BIOTRONIK Coml Médica LTDA
São Paulo, 01533-000
About this study
Official title: Simplifying Access to Full Early Atrial Diagnostics in Single Chamber ICD Patients Using the DX Lead and Continuous Home Monitoring in Brazil
To demonstrate the value and benefits of BIOTRONIK's exclusive DX technology in assessing the incidence of supraventricular arrhythmias, mainly atrial fibrillation (AF), in patients with an indication for single chamber ICDs.
Effects of the DX technology on related events, such as delivery of therapies and medical management, including eventual complications.
Extended benefits offered by DX devices when associated with daily remote monitoring, by means of BIOTRONIK's Home Monitoring Service Center (HMSC).
Read the detailed description
To demonstrate the value and benefits of BIOTRONIK's exclusive DX technology in assessing the incidence of supraventricular arrhythmias, mainly atrial fibrillation (AF), in patients with an indication for single chamber ICDs.
Effects of the DX technology on related events, such as delivery of therapies and medical management, including eventual complications.
Extended benefits offered by DX devices when associated with daily remote monitoring, by means of BIOTRONIK's Home Monitoring Service Center (HMSC).
Primary Endpoint:
- First confirmed episode of AF or atrial flutter (AFL) or supraventricular tachycardia (SVT), detected and transmitted to the HMSC.
Other events of interest:
- Rate of successful transmissions received and stored on the HMSC platform;
- Hospital admissions related to cardiologic outcomes, at any time throughout the FU period;
- A composite outcome of any of the following device-related complications: Need for any lead repositioning or replacement, pneumothorax, new pericardial effusion, tamponade, procedure-related death or wound infection, within 60 days after the ICD insertion.
- Conditions
- Arrhythmias, Cardiac
- Being tested
- BIOTRONIK ICDs with DX Technology
- Medical subject headings
- Arrhythmias, Cardiac
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
BIOTRONIK ICDs with DX TechnologyDevice
The BIOTRONIK DX system offers a single chamber ICD that enables sensing of atrial signals through floating atrial dipoles, using a single ventricular lead. This technology enables enhanced arrhythmia diagnosis based on atrial and ventricular electrograms and, in addition, early diagnosis and automatic transmission of AF and heart failure (HF) diagnostic data. The DX technology provides several features in a single chamber device that are usually only found in dual chamber devices, including atrial diagnostics and SVT discrimination - early detection of SAF, increased diagnostics accuracy, dual-chamber discrimination. Nevertheless, the benefits of a single chamber device are preserved: reduced lead complications, reduced procedure complexity, elimination of costs for atrial lead. The DX system also integrates with BIOTRONIK Home Monitoring, allowing physicians to remotely follow their patients' clinical and device statuses with daily updates.
What is being measured
The primary outcome is the main question the study is designed to answer.
New Onset of Atrial Fibrillation, Atrial Flutter or Supraventricular Tachycardia Recorded Episodes
All patients enrolled presented with sinus rhythm, confirmed also during the implant. Outcome was considered positive with the occurence of first confirmed episode of Atrial Fibrillation (AF) or atrial flutter (AFL) or supraventricular tachycardia (SVT), detected and transmitted to BIOTRONIK's Home Monitoring Service Center (HMSC), lasting at least 30 seconds to be considered relevant. The adjudication was carried out by the independent investigator in charge of the remote monitoring.
Measured: 12 months
Secondary outcomes (3)
Successful Remote Monitoring Data Transmission to BIOTRONIK's HMSC Platform
All patients enrolled received a remote monitoring unit (BIOTRONIK's CARDIOMESSENGER SMART) providing automatic telemetry (read only) for data gathering and encrypted transmission to BIOTRONIK's Home Monitoring Service Center (HMSC). This outcome represents the percentage of days with successful Home Monitoring transmissions after the first recorded transmission. The Home Monitoring system automatically sends encrypted data through the mobile network to the BIOTRONIK Home Monitoring Service Center (HMSC), using cellular telephone network for data transmission.
Measured: 12 months
Cardiologic Hospitalization
Number of patients with at least one hospitalization related to cardiologic outcomes during the follow-up period.
Measured: 12 months
Device Related Complication
A composite outcome of any of the following device-related complications: Number of patients who need for any lead repositioning or replacement, pneumothorax, new pericardial effusion, tamponade, procedure-related death, or wound infection, within 60 days after the ICD insertion.
Measured: 60 days
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted3 May 2021
- Study start24 Nov 2021
- Primary completion31 Jul 2024
- Study completion31 Jul 2025
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Publications (24)Papers the sponsor has linked to this study.
- Other trials for Arrhythmias, CardiacStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case-control
- Time perspective
- Prospective
- Enrolment
- 56 participants (actual)
- Target duration
- 12 Months
Sponsor and investigators
- Lead sponsor
- Biotronik SE & Co. KG
- Sponsor type
- Industry (pharma, biotech, devices)
- Collaborators
- Irmandade Santa Casa de Misericórdia de Porto Alegre
- Responsible party
- Sponsor
- Investigators
- Carlos CK Kalil, M.D., Ph.D., Principal investigator, Santa Casa de Misericórdia de Porto Alegre - Brugada Institute
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04869527
- Sponsor's protocol ID
- TA118
- Acronym
- SAFE-DX-Home
- Status last verified
- Oct 2024
- First submitted
- 28 Apr 2021
- Last updated
- 9 Jul 2026
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Healey JS, Connolly SJ, Gold MR, Israel CW, Van Gelder IC, Capucci A, Lau CP, Fain E, Yang S, Bailleul C, Morillo CA, Carlson M, Themeles E, Kaufman ES, Hohnloser SH; ASSERT Investigators. Subclinical atrial fibrillation and the risk of stroke. N Engl J Med. 2012 Jan 12;366(2):120-9. doi: 10.1056/NEJMoa1105575.
PubMed 22236222Glotzer TV, Hellkamp AS, Zimmerman J, Sweeney MO, Yee R, Marinchak R, Cook J, Paraschos A, Love J, Radoslovich G, Lee KL, Lamas GA; MOST Investigators. Atrial high rate episodes detected by pacemaker diagnostics predict death and stroke: report of the Atrial Diagnostics Ancillary Study of the MOde Selection Trial (MOST). Circulation. 2003 Apr 1;107(12):1614-9. doi: 10.1161/01.CIR.0000057981.70380.45. Epub 2003 Mar 24.
PubMed 12668495Peterson PN, Varosy PD, Heidenreich PA, Wang Y, Dewland TA, Curtis JP, Go AS, Greenlee RT, Magid DJ, Normand SL, Masoudi FA. Association of single- vs dual-chamber ICDs with mortality, readmissions, and complications among patients receiving an ICD for primary prevention. JAMA. 2013 May 15;309(19):2025-34. doi: 10.1001/jama.2013.4982.
PubMed 23677314Matlock DD, Peterson PN, Wang Y, Curtis JP, Reynolds MR, Varosy PD, Masoudi FA. Variation in use of dual-chamber implantable cardioverter-defibrillators: results from the national cardiovascular data registry. Arch Intern Med. 2012 Apr 23;172(8):634-41; discussion 641. doi: 10.1001/archinternmed.2012.394.
PubMed 22529229Dewland TA, Pellegrini CN, Wang Y, Marcus GM, Keung E, Varosy PD. Dual-chamber implantable cardioverter-defibrillator selection is associated with increased complication rates and mortality among patients enrolled in the NCDR implantable cardioverter-defibrillator registry. J Am Coll Cardiol. 2011 Aug 30;58(10):1007-13. doi: 10.1016/j.jacc.2011.04.039.
PubMed 21867834Dries DL, Exner DV, Gersh BJ, Domanski MJ, Waclawiw MA, Stevenson LW. Atrial fibrillation is associated with an increased risk for mortality and heart failure progression in patients with asymptomatic and symptomatic left ventricular systolic dysfunction: a retrospective analysis of the SOLVD trials. Studies of Left Ventricular Dysfunction. J Am Coll Cardiol. 1998 Sep;32(3):695-703. doi: 10.1016/s0735-1097(98)00297-6.
PubMed 9741514Lee DS, Krahn AD, Healey JS, Birnie D, Crystal E, Dorian P, Simpson CS, Khaykin Y, Cameron D, Janmohamed A, Yee R, Austin PC, Chen Z, Hardy J, Tu JV; Investigators of the Ontario ICD Database. Evaluation of early complications related to De Novo cardioverter defibrillator implantation insights from the Ontario ICD database. J Am Coll Cardiol. 2010 Feb 23;55(8):774-82. doi: 10.1016/j.jacc.2009.11.029.
PubMed 20170816Healey JS, Toff WD, Lamas GA, Andersen HR, Thorpe KE, Ellenbogen KA, Lee KL, Skene AM, Schron EB, Skehan JD, Goldman L, Roberts RS, Camm AJ, Yusuf S, Connolly SJ. Cardiovascular outcomes with atrial-based pacing compared with ventricular pacing: meta-analysis of randomized trials, using individual patient data. Circulation. 2006 Jul 4;114(1):11-7. doi: 10.1161/CIRCULATIONAHA.105.610303. Epub 2006 Jun 26.
PubMed 16801463Castellanos A, Berkovits BV, Castillo CA, Befeler B. Sextapolar catheter electrode for temporary sequential atrioventricular pacing. Cardiovasc Res. 1974 Sep;8(5):712-4. doi: 10.1093/cvr/8.5.712. No abstract available.
PubMed 4434373Curry PV, Raper DA. Single lead for permanent physiological cardiac pacing. Lancet. 1978 Oct 7;2(8093):757-9. doi: 10.1016/s0140-6736(78)92647-8.
PubMed 80685Ovsyshcher IE, Crystal E. VDD pacing: under evaluated, undervalued, and underused. Pacing Clin Electrophysiol. 2004 Oct;27(10):1335-8. doi: 10.1111/j.1540-8159.2004.00635.x. No abstract available.
PubMed 15511240Shurrab M, Elitzur Y, Healey JS, Gula L, Kaoutskaia A, Israel C, Lau C, Crystal E. VDD vs DDD pacemakers: a meta-analysis. Can J Cardiol. 2014 Nov;30(11):1385-91. doi: 10.1016/j.cjca.2014.04.035. Epub 2014 May 28.
PubMed 25228132Gradaus R, Gonska BD, Stellbrink C, Cron T, Tebbenjohanns J, Blomstrom-Lundqvist C, Himmrich E, Salerno JA, Osswald S, Gommer ED, Van Veen BK, Bocker D. European clinical experience with a dual chamber single pass sensing and pacing defibrillation lead. Pacing Clin Electrophysiol. 2002 Jul;25(7):1079-86. doi: 10.1046/j.1460-9592.2002.01079.x.
PubMed 12164450Gradaus R, Block M, Dorszewski A, Schriever C, Hammel D, Scheld HH, Borggrefe M, Breithardt G, Bocker D. Implantation of a dual chamber pacing and sensing single pass defibrillation lead. Pacing Clin Electrophysiol. 2001 Apr;24(4 Pt 1):416-23. doi: 10.1046/j.1460-9592.2001.00416.x.
PubMed 11341077Niehaus M, de Sousa M, Klein G, Korte T, Pfeiffer D, Walles T, Raymondos K, Tebbenjohanns J. Chronic experiences with a single lead dual chamber implantable cardioverter defibrillator system. Pacing Clin Electrophysiol. 2003 Oct;26(10):1937-43. doi: 10.1046/j.1460-9592.2003.00299.x.
PubMed 14516332
Study at a glance
From the registry record, last updated by the sponsor on 9 Jul 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Simplifying Access to Full Early Atrial Diagnostics in Single Chamber ICD Patients Using the DX Lead and Continuous Home Monitoring in Brazil
- ClinicalTrials.gov ID
- NCT04869527
- Acronym / sponsor ID
- SAFE-DX-Home / TA118
- Conditions
- Arrhythmias, Cardiac
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 56 participants (actual)
- Lead sponsor
- Biotronik SE & Co. KGIndustry (pharma, biotech, devices)
- Collaborators
- Irmandade Santa Casa de Misericórdia de Porto Alegre
- Study start
- 24 Nov 2021 (actual)
- Primary completion
- 31 Jul 2024 (actual)
- Study completion
- 31 Jul 2025 (actual)
- First posted
- 3 May 2021 (actual)
- Results
- Posted 9 Jul 2026
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
To demonstrate the value and benefits of BIOTRONIK's exclusive DX technology in assessing the incidence of supraventricular arrhythmias, mainly atrial fibrillation (AF), in patients with an indication for single chamber ICDs.
Effects of the DX technology on related events, such as delivery of therapies and medical management, including eventual complications.
Extended benefits offered by DX devices when associated with daily remote monitoring, by means of BIOTRONIK's Home Monitoring Service Center (HMSC).
Detailed description
To demonstrate the value and benefits of BIOTRONIK's exclusive DX technology in assessing the incidence of supraventricular arrhythmias, mainly atrial fibrillation (AF), in patients with an indication for single chamber ICDs.
Effects of the DX technology on related events, such as delivery of therapies and medical management, including eventual complications.
Extended benefits offered by DX devices when associated with daily remote monitoring, by means of BIOTRONIK's Home Monitoring Service Center (HMSC).
Primary Endpoint:
- First confirmed episode of AF or atrial flutter (AFL) or supraventricular tachycardia (SVT), detected and transmitted to the HMSC.
Other events of interest:
- Rate of successful transmissions received and stored on the HMSC platform;
- Hospital admissions related to cardiologic outcomes, at any time throughout the FU period;
- A composite outcome of any of the following device-related complications: Need for any lead repositioning or replacement, pneumothorax, new pericardial effusion, tamponade, procedure-related death or wound infection, within 60 days after the ICD insertion.
Study design
- Observational model
- Case-control
- Time perspective
- Prospective
- Target follow-up
- 12 Months
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Patients requiring an ICD implant
Key inclusion criteria (6 listed)
- Indication for implanting of a single chamber ICD (primary or secondary prevention) according to current guidelines;
- Sustained sinus rhythm as the current prevalent atrial rhythm;
- Planned de novo implantation with a BIOTRONIK single chamber DX ICD system;
- Patient is able to understand the nature of study and to provide written informed consent;
- Patient is willing and able to perform all follow up visits at the study site;
Key exclusion criteria (6 listed)
- Age < 18 years
- Any limitation to contractual capability;
- Female patients who are pregnant or breast feeding or planning pregnancy during the course of the study;
- Known active malignant disease or recovered from malignant disease within 2 years prior to enrollment;
- Life expectancy < 2 years;
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| BIOTRONIK ICDs with DX TechnologyThe BIOTRONIK DX system offers a single chamber ICD that enables sensing of atrial signals through floating atrial dipoles, using a single ventricular lead. This technology enables enhanced arrhythmia diagnosis based on atrial and ventricular electrograms and, in addition, early diagnosis and automatic transmission of AF and heart failure (HF) diagnostic data. The DX technology provides several features in a single chamber device that are usually only found in dual chamber devices, including atrial diagnostics and SVT discrimination - early detection of SAF, increased diagnostics accuracy, dual-chamber discrimination. Nevertheless, the benefits of a single chamber device are preserved: reduced lead complications, reduced procedure complexity, elimination of costs for atrial lead. The DX system also integrates with BIOTRONIK Home Monitoring, allowing physicians to remotely follow their patients' clinical and device statuses with daily updates. | Device | – |
Primary outcome
New Onset of Atrial Fibrillation, Atrial Flutter or Supraventricular Tachycardia Recorded Episodes
Time frame: 12 months
All patients enrolled presented with sinus rhythm, confirmed also during the implant. Outcome was considered positive with the occurence of first confirmed episode of Atrial Fibrillation (AF) or atrial flutter (AFL) or supraventricular tachycardia (SVT), detected and transmitted to BIOTRONIK's Home Monitoring Service Center (HMSC), lasting at least 30 seconds to be considered relevant. The adjudication was carried out by the independent investigator in charge of the remote monitoring.
3 secondary outcomes
Successful Remote Monitoring Data Transmission to BIOTRONIK's HMSC Platform
Time frame: 12 months
Cardiologic Hospitalization
Time frame: 12 months
Device Related Complication
Time frame: 60 days
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 9 Jul 2026.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Background: PubMed 22236222Healey JS, Connolly SJ, Gold MR, Israel CW, Van Gelder IC, Capucci A, Lau CP, Fain E, Yang S, Bailleul C, Morillo CA, Carlson M, Themeles E, Kaufman ES, Hohnloser SH; ASSERT Investigators. Subclinical atrial fibrillation and the risk of stroke. N Engl J Med. 2012 Jan 12;366(2):120-9. doi: 10.1056/NEJMoa1105575.
- Background: PubMed 12668495Glotzer TV, Hellkamp AS, Zimmerman J, Sweeney MO, Yee R, Marinchak R, Cook J, Paraschos A, Love J, Radoslovich G, Lee KL, Lamas GA; MOST Investigators. Atrial high rate episodes detected by pacemaker diagnostics predict death and stroke: report of the Atrial Diagnostics Ancillary Study of the MOde Selection Trial (MOST). Circulation. 2003 Apr 1;107(12):1614-9. doi: 10.1161/01.CIR.0000057981.70380.45. Epub 2003 Mar 24.
- Background: PubMed 23677314Peterson PN, Varosy PD, Heidenreich PA, Wang Y, Dewland TA, Curtis JP, Go AS, Greenlee RT, Magid DJ, Normand SL, Masoudi FA. Association of single- vs dual-chamber ICDs with mortality, readmissions, and complications among patients receiving an ICD for primary prevention. JAMA. 2013 May 15;309(19):2025-34. doi: 10.1001/jama.2013.4982.
- Background: PubMed 22529229Matlock DD, Peterson PN, Wang Y, Curtis JP, Reynolds MR, Varosy PD, Masoudi FA. Variation in use of dual-chamber implantable cardioverter-defibrillators: results from the national cardiovascular data registry. Arch Intern Med. 2012 Apr 23;172(8):634-41; discussion 641. doi: 10.1001/archinternmed.2012.394.
- Background: PubMed 21867834Dewland TA, Pellegrini CN, Wang Y, Marcus GM, Keung E, Varosy PD. Dual-chamber implantable cardioverter-defibrillator selection is associated with increased complication rates and mortality among patients enrolled in the NCDR implantable cardioverter-defibrillator registry. J Am Coll Cardiol. 2011 Aug 30;58(10):1007-13. doi: 10.1016/j.jacc.2011.04.039.
- Background: PubMed 9741514Dries DL, Exner DV, Gersh BJ, Domanski MJ, Waclawiw MA, Stevenson LW. Atrial fibrillation is associated with an increased risk for mortality and heart failure progression in patients with asymptomatic and symptomatic left ventricular systolic dysfunction: a retrospective analysis of the SOLVD trials. Studies of Left Ventricular Dysfunction. J Am Coll Cardiol. 1998 Sep;32(3):695-703. doi: 10.1016/s0735-1097(98)00297-6.
- Background: PubMed 20170816Lee DS, Krahn AD, Healey JS, Birnie D, Crystal E, Dorian P, Simpson CS, Khaykin Y, Cameron D, Janmohamed A, Yee R, Austin PC, Chen Z, Hardy J, Tu JV; Investigators of the Ontario ICD Database. Evaluation of early complications related to De Novo cardioverter defibrillator implantation insights from the Ontario ICD database. J Am Coll Cardiol. 2010 Feb 23;55(8):774-82. doi: 10.1016/j.jacc.2009.11.029.
- Background: PubMed 16801463Healey JS, Toff WD, Lamas GA, Andersen HR, Thorpe KE, Ellenbogen KA, Lee KL, Skene AM, Schron EB, Skehan JD, Goldman L, Roberts RS, Camm AJ, Yusuf S, Connolly SJ. Cardiovascular outcomes with atrial-based pacing compared with ventricular pacing: meta-analysis of randomized trials, using individual patient data. Circulation. 2006 Jul 4;114(1):11-7. doi: 10.1161/CIRCULATIONAHA.105.610303. Epub 2006 Jun 26.
- Background: PubMed 4434373Castellanos A, Berkovits BV, Castillo CA, Befeler B. Sextapolar catheter electrode for temporary sequential atrioventricular pacing. Cardiovasc Res. 1974 Sep;8(5):712-4. doi: 10.1093/cvr/8.5.712. No abstract available.
- Background: PubMed 80685Curry PV, Raper DA. Single lead for permanent physiological cardiac pacing. Lancet. 1978 Oct 7;2(8093):757-9. doi: 10.1016/s0140-6736(78)92647-8.
- Background: PubMed 15511240Ovsyshcher IE, Crystal E. VDD pacing: under evaluated, undervalued, and underused. Pacing Clin Electrophysiol. 2004 Oct;27(10):1335-8. doi: 10.1111/j.1540-8159.2004.00635.x. No abstract available.
- Background: PubMed 25228132Shurrab M, Elitzur Y, Healey JS, Gula L, Kaoutskaia A, Israel C, Lau C, Crystal E. VDD vs DDD pacemakers: a meta-analysis. Can J Cardiol. 2014 Nov;30(11):1385-91. doi: 10.1016/j.cjca.2014.04.035. Epub 2014 May 28.
- Individual participant dataSharing planned: No
Related trials for Arrhythmias, Cardiac
Active, not recruiting
VOLT CE Mark Study
Atrial Arrhythmia, Atrial Fibrillation
RecruitingObservational study
Southeast Asian Brugada Syndrome Cohort
Brugada Syndrome
Recruiting
Cardiac RADIoablation Versus Repeat Catheter Ablation: a Pivotal Randomized Clinical Trial Evaluating Safety and Efficacy for Patients With High-risk Refractory Ventricular Tachycardia (RADIATE-VT)
Tachycardia, Ventricular
RecruitingObservational study
AI-Based Differential Diagnosis and Localization of Tachycardia Using ECG: Multicenter Registry (EP-AI ASSIST)
Tachycardia, Paroxysmal Supraventricular Tachycardia
RecruitingObservational study
AI-Based Cardiac Analysis Using 12-Lead and 1-Lead ECG
Heart Failure, Atrial Fibrillation (AF)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Carlos CK Kalil, M.D., Ph.D. principal investigator
Santa Casa de Misericórdia de Porto Alegre - Brugada Institute
2 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Arrhythmias, Cardiac, run by Biotronik SE & Co. KG at 2 sites in Brazil.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 6 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 9 Jul 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 2 sites in Brazil. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 9 Jul 2026). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
New Onset of Atrial Fibrillation, Atrial Flutter or Supraventricular Tachycardia Recorded Episodes (time frame: 12 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT04869527, which also lists 24 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Jul 2026.