AzTrials
AzTrials

SurgeryCOMPARENCT04871620

Reliability of a New Pulse Contour Technique for Diagnosing an Increase in Stroke Volume During a Fluid Challenge for Hemodynamic Optimization in Patients Scheduled for High-risk Abdominal Surgery: Comparison With Transthoracic Echocardiography: COMPARE Study

An observational study of Surgery and Cardiac Output, Low, run by Centre Hospitalier Universitaire de Nīmes at 1 site in France.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The present study aims at assessing the ability of a new pulse contour device for diagnosing a >15% stroke volume (SV) increase during patient hemodynamic optimization by fluid challenge in high risk abdominal surgery. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Surgery, Cardiac Output, Low
What is being tested?
>15% SV increase during fluid challenge
How many people
100 participants
Where
1 siteFrance
Study dates
12 Apr 2016to 8 Jan 2024
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Patients scheduled for intermediate and high-risk abdominal surgery were eligible to participate

Who may be able to join

  • Adult patient ASA status 1-3 who were orally informed and did refuse to participate.
  • Patient in whom general anesthesia with tracheal intubation were planned.
  • Patient in whom an arterial catheter and a monitoring of cardiac output by esophageal Doppler were indicated for hemodynamic optimization
  • Patient with cardiac sinusal mode

Who cannot join

  • Patient < 18-year-old
  • Cardiac arrythmia
  • Patient with anomaly in oro-pharyngo-esophageal tractus
  • Patients with hemostasis anomaly (PT < 30%, platelets < 50 000 elements/mm3)
  • Patient in whom the cardiac output monitoring or measurement was not possible by Esophageal Doppler or echography
  • Patients in whom cardiac arrythmia occurred during the procedure of hemodynamic optimization.

Trial locations and contacts

1 site in 1 country.

France1 site
  • CHU de NIMES

    Nîmes, 30029

Other trials in France

About this study

The present study aims at assessing the ability of a new pulse contour device for diagnosing a >15% stroke volume (SV) increase during patient hemodynamic optimization by fluid challenge in high risk abdominal surgery.

Read the detailed description

In European countries, day-7 mortality rate could reach 1-5. %. Emergency conditions, American Society Assessment (ASA) and major surgery were associated with a higher risk of immediate mortality. Moreover, hemodynamic instability is well known to lead to postoperative complications and a higher risk of mortality.

Since, nearly 30 years, optimization of hemodynamic conditions, especially via an optimization of the fluid administration has been shown to improve immediate and long-term patient outcome. This strategy is currently widely accepted and recommended in medium and high-risk surgery. Therefore, optimizing cardiac output and one of its surrogate is proposed over intraoperative surgery. For assessing the cardiac output or the indexed stroke volume, esophageal Doppler and pulse contour technique have been proposed and have shown that they could improve patient outcome.

However, the reliability of esophageal Doppler, pulse contour and non-invasive techniques assessing cardiac output and its ability to detect a change in the initial value of CO have been challenged. Initially, the reliability of a technique for measuring CO has been described by using a correlation coefficient and by building Bland \& Altman diagram. However, searching a correlation between two different techniques measuring the same parameter will lead to a correlation. In the same, Bland \& Altman technique shows the mean difference between measurements of the same parameters; However, demonstrating a good reliability should be shown by a narrow limit of agreement with no definition of the narrowness. Indeed, a value of cardiac index (CI) = 3 l/min/m2 with a mean difference of 0 +/- 1.1 /min/m2 by Bland \& Altman technique mean that the CI value could be within 1 and 5 l/min/m2 that could lead to different treatment such as fluid challenge, vasopressor or inotrope infusion.

An interesting method for comparing two techniques measuring the same parameter could be to challenge one technique versus the other one in decision-making. Applying this method to techniques measuring CO, we could search for the interest of a new technique for diagnosing an increase in CO after a fluid challenge for optimizing cardiac preload and hemodynamic status. Esophageal Doppler is classically recommended for optimizing hemodynamic patient in high-risk surgery.

A new device using pulse contour technology has been available since a few years. Therefore, the present study aims at assessing the ability of this device for diagnosing an increase in CO > 15% during patient hemodynamic optimization by fluid challenge.

Being tested
>15% SV increase during fluid challenge
Keywords
High risk abdominal surgery, hemodynamic optimization, stroke volume, pulse contour
Medical subject headings
Cardiac Output, Low

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • >15% SV increase during fluid challengeDiagnostic test

    The stroke volume will be measured before and after 15 minutes fluid challenge with crystalloids

Study groups in NCT04871620
Study groupRoleWhat they receive
Hemodynamic optimizationPatients scheduled for intermediate and high-risk abdominal surgery were eligible to participate
Receives: Diagnostic Test: >15% SV increase during fluid challenge

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Ability of pulse contour for diagnosing a >15% increase in stroke volume

    Ability of pulse contour for diagnosing a >15% increase in stroke volume

    Measured: 15 minutes

Secondary outcomes (2)
  1. Comparison with the ability of other techniques

    Comparison with the ability of other techniques (Esophagial Doppler, other pulse contour techniques for diagnosing a >15% SV increase)

    Measured: 15 minutes

  2. Ability for predicting a >15% SV increase

    Ability of Esophagial Doppler and Pulse contour techniques for predicting a >15% SV increase after rapid infusion of 100ml cristalloid over one minute (mini-fluid challenge)

    Measured: 15 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 May 2021
  2. Study start12 Apr 2016
  3. Primary completion8 Jan 2024
  4. Study completion8 Jan 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
100 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04871620
Sponsor's protocol ID
IRB 15.11.02
Acronym
COMPARE
Status last verified
Jun 2026
First submitted
29 Apr 2021
Last updated
18 Jun 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

An observational study of Surgery and Cardiac Output, Low, run by Centre Hospitalier Universitaire de Nīmes at 1 site in France.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 18 Jun 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Ability of pulse contour for diagnosing a >15% increase in stroke volume (time frame: 15 minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Jun 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in