AzTrials
AzTrials

Bimaxillary ProtrusionNCT04878939

Evaluation of Incisors' Position Following Anterior Segment Retraction

A study testing Power chain used for anterior segment retraction and T-loop fabricated to perform anterior segment retraction in people with Bimaxillary Protrusion, run by Future University in Egypt at 1 site in Egypt.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

There's scarcity in literature concerning the issue of anterior segment retraction technique and its effect on anterior teeth position. Therefore, a randomized clinical trial has been chosen to investigate this issue, aiming to support clinicians with the best guidelines for anterior segment retraction. Read more about this study

Who is it for?
Ages 13 to 25 years, women onlyHealthy volunteers can take part
Conditions the study is for
Bimaxillary Protrusion
What is being tested?
Power chain used for anterior segment retraction and T-loop fabricated to perform anterior segment retraction
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
1 siteEgypt
Study dates
4 Feb 2019to 13 Dec 2020
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 13 to 25 years
  • Women only
  • Healthy volunteers accepted
  • Child, Adult

Who may be able to join

  • Female patients (Age 13- 25 y)
  • Class I molar relation (Angle's classification)
  • Bimaxillary protrusion requiring extraction of four first premolars and maximum anchorage.
  • full permanent dentition (except 3rd molars)
  • Good general and oral health

Who cannot join

  • Systemic disease or syndromes or on anti-inflammatory medication.
  • Extracted or missing permanent teeth (other than 3rd molars)
  • Badly decayed teeth (other than 1st premolars)
  • Parafunctional habits
  • History of previous orthodontics treatment

Trial locations and contacts

1 site in 1 country.

Egypt1 site
  • Future University in Egypt

    Cairo

Other trials in Egypt

About this study

Official title: Evaluation of Incisors' Position Following Anterior Segment Retraction Using Friction Versus Frictionless Mechanics: A Randomized Clinical Trial

There's scarcity in literature concerning the issue of anterior segment retraction technique and its effect on anterior teeth position. Therefore, a randomized clinical trial has been chosen to investigate this issue, aiming to support clinicians with the best guidelines for anterior segment retraction.

Read the detailed description

Thirty females with bimaxillary protrusion were randomly allocated into two groups. In one group, anterior segment retraction was commenced using an elastomeric chain rendering 160 g/side extending between mini-screw implant and a hook crimped on 0.017- by 0.025-inch stainless steel wire distal to the lateral incisor. In the other group, anterior segment retraction was done using closing T-loops fabricated from 0.017- by 0.025-inch titanium molybdenum alloy (TMA) wire rendering comparable retraction force. Three-dimensional analysis of incisors' buccolingual (BL)- torque, mesiodistal (MD)- tip, vertical position changes and root resorption were assessed using cone beam computed tomography scans.

Being tested
Power chain used for anterior segment retraction, T-loop fabricated to perform anterior segment retraction
Keywords
friction, frictionless, CBCT, anterior segment retraction, T loop

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Power chain used for anterior segment retractionOther

    Elastomeric chain rendering 160 g/side extending between mini-screw implant and a hook crimped on 0.017- by 0.025-inch stainless steel wire distal to the lateral incisor.

  • T-loop fabricated to perform anterior segment retractionOther

    In the frictionless group, anterior segment retraction was done using closing T-loops fabricated from 0.017- by 0.025-inch titanium molybdenum alloy (TMA) wire rendering comparable retraction force.

Study groups in NCT04878939
Study groupRoleWhat they receive
Anterior segment retraction using sliding mechanics (friction)ExperimentalPower chain
Receives: Other: Power chain used for anterior segment retraction
Anterior segment retraction using segmental mechanics (frictionless)ExperimentalT-loop
Receives: Other: T-loop fabricated to perform anterior segment retraction

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Torque of the incisors

    The change of the outer angle between long axis of each upper anterior tooth and palatal plane on CBCT pre and post retracation and the change in the outer angle between long axis of each lower anterior tooth and horizontal plane on CBCT pre and post retracation

    Measured: through study completion (Pre/post retraction), an average of 6 months

  2. Tip of the incisors

    The change of the angle between the long axis of the incisors and mid-sagittal plane on CBCT pre and post retracation

    Measured: through study completion (Pre/post retraction), an average of 6 months

  3. Vertical changes of the incisors

    The change of the linear distance between the centroid of each maxillary anterior tooth and palatal Plane on CBCT pre and post retracation and The change of the linear distance between centroid of each mandibular anterior tooth and horizontal Plane on CBCT pre and post retracation

    Measured: through study completion (Pre/post retraction) , an average of 6 months

Secondary outcomes (1)
  1. Root resorption of the anterior teeth

    measuring the amount of resorption using CBCT in mm pre and post retraction

    Measured: through study completion (Pre/post retraction), an average of 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted10 May 2021
  2. Study start4 Feb 2019
  3. Primary completion1 Sep 2020
  4. Study completion13 Dec 2020

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Outcomes assessor
Enrolment
30 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04878939
Sponsor's protocol ID
FUE.REC 11/10-2018
Status last verified
May 2021
First submitted
25 Apr 2021
Last updated
10 May 2021
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes: All collected IPD

Publications

  • Bakhit DMI, Tawfik MGY, Dehis HM, Mostafa YA, El Sharaby FA. Position and root resorption of the incisors following anterior segment retraction using friction versus frictionless mechanics: A randomised controlled trial. J Orthod. 2025 Mar;52(1):12-21. doi: 10.1177/14653125241261402. Epub 2024 Jul 25.

    PubMed 39049618

Questions about this trial

What is this clinical trial studying?

A study testing Power chain used for anterior segment retraction and T-loop fabricated to perform anterior segment retraction in people with Bimaxillary Protrusion, run by Future University in Egypt at 1 site in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 10 May 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Torque of the incisors (time frame: through study completion (Pre/post retraction), an average of 6 months). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04878939, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 May 2021.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in