AzTrials
AzTrials

Labor PainNCT04946032

Optimum Length of Catheter in the Epidural Space for Labor Analgesia in Non-obese Women: a Randomised Controlled Trial of 4 cm Versus 5 cm

A study testing Epidural catheter in people with Labor Pain, run by Samuel Lunenfeld Research Institute, Mount Sinai Hospital at 1 site in Canada.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Epidural analgesia was introduced to the world of obstetrics in 1909 by Walter Stoeckel. Over the following 100 years it has developed to become the gold-standard for delivery of intra-partum analgesia, with between 60 and 75% of North American parturients receiving an epidural during their labor. Read more about this study

Who is it for?
Ages 18 to 50 years, women onlyHealthy volunteers can take part
Conditions the study is for
Labor Pain
What is being tested?
Epidural catheter
Could I receive a placebo?
No, everyone receives an active treatment
How many people
200 participants
Where
1 siteCanada
Study dates
23 Nov 2021to 27 Jul 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 50 years
  • Women only
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • All women aged 18 years and above.
  • In established second stage of labor.
  • 3-7 cm dilation at time of insertion.
  • Women with BMI < 40 kg/m2

Who cannot join

  • Known contraindication to epidural insertion.
  • Inability or unwillingness to provide written consent.
  • Previous difficult epidural insertion.
  • Previous failed epidural.
  • Imminent instrumental or operative delivery.
  • Dural puncture.
  • Combined spinal epidural analgesia.
  • High BMI > 40 kg/m2

Trial locations and contacts

1 site in 1 country.

Canada1 site
  • Mount Sinai Hospital

    Toronto, Ontario, M5G1X5

Other trials in Canada

About this study

Epidural analgesia was introduced to the world of obstetrics in 1909 by Walter Stoeckel. Over the following 100 years it has developed to become the gold-standard for delivery of intra-partum analgesia, with between 60 and 75% of North American parturients receiving an epidural during their labor. Effective labor analgesia has been shown to improve maternal and fetal outcomes. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space. Dislodgement or displacement of epidural catheter remains a significant cause for failure with analgesia. Novel methods of fixation may further reduce the risk of catheter migration. Another factor is the direction of travel within the epidural space, only 13% of lumbar catheters remain uncoiled after insertion of more than 4 cm into the epidural space.

Hypothesis: The investigators hypothesize that catheters inserted to 4 cm will have a lower rate of failure when compared to those inserted to 5 cm.

Read more

Objective: This study aims to evaluate the difference in quality of labor analgesia delivered by epidural catheters inserted to either 4 or 5 cm into the epidural space.

This study will be conducted as an interventional double-blinded randomised control trial to establish best practice.

Read the detailed description

Effective labor analgesia has been shown to improve maternal and fetal outcomes. It is of paramount importance to the obstetric anesthesiologist to optimize the quality of labor analgesia and identify any factors leading to ineffective epidural analgesia. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space.

Previous studies have advocated, for varying reasons, different lengths of catheter to be left in the space; these range from 2cm to 8cm. Longer epidural lengths in the space can be associated with foraminal escape, leading to unilateral block, and intravascular insertion, prompting additional manipulation. Shorter lengths have previously been associated with more frequent dislodgement. The directionality of the epidural catheter once in the space has been demonstrated to correlate with misdirection.

The aim of the study would be to standardize practice in how much epidural catheter is threaded into the epidural space.

Conditions
Labor Pain
Being tested
Epidural catheter
Keywords
epidural catheter, epidural analgesia, labor epidural
Medical subject headings
Labor Pain

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Epidural catheterOther

    Also called epidural

    The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.

Study groups in NCT04946032
Study groupRoleWhat they receive
4 cm epidural catheterActive comparatorThe epidural catheter will be thread into the epidural space at a length of 4 cm.
Receives: Other: Epidural catheter
5 cm epidural catheterActive comparatorThe epidural catheter will be thread into the epidural space at a length of 5 cm.
Receives: Other: Epidural catheter

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Sensory block level < T10

    Sensory block level to ice will be measured 1 hour after the loading dose is administered.

    Yes: inadequate block No: adequate block

    Measured: 1 hour

  2. Block height discrepancy

    Unilateral block or block height discrepancy of >3 dermatomal levels at any time prior to delivery.

    Yes: inadequate block No: adequate block

    Measured: 24 hours

  3. Re-siting of the epidural

    Re-siting of the epidural at any time during labour will indicate an inadequate block, for any of the following reasons:

    • Inadequate analgesia
    • Persistent unilateral block
    • Persistent intravascular placement
    • Extensive motor block
    • Hypotension
    • High block

    Measured: 24 hours

  4. Adjustment of catheter length

    Adjustment of catheter length at any time during labour would also indicate an inadequate block.

    Measured: 24 hours

  5. Abandonment of epidural or substitute for alternative method of analgesia after initial failure: questionnaire

    The epidural analgesia will also be considered inadequate if the procedure is abandoned or another method of analgesia is used. This will be recorded by the anesthesiologist.

    Measured: 24 hours

Secondary outcomes (10)
  1. Pain score >3 at any time during labour: questionnaire

    A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever.

    Measured: 24 hours

  2. Number of epidural top-ups administered by the nursing team

    The number of times the labour and delivery nurse has to administer a top-up of the epidural.

    Measured: 24 hours

  3. Number of epidural top-ups administered by the anesthesiologist

    The number of times the anesthesiologist has to administer a top-up of the epidural.

    Measured: 24 hours

  4. Pain scores recorded throughout labour: questionnaire

    A verbal numerical rating score (VNRS), where 0=no pain and 10=worst pain ever. A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever.

    Measured: 24 hours

  5. Hourly sensory block height assessment

    Hourly sensory block height assessment, using sensation to ice. This is recorded hourly as standard practice.

    Measured: 24 hours

  6. Incidence of intravascular epidural placement

    Any incidence of intravascular epidural placement during labour will be recorded.

    Measured: 24 hours

  7. Incidence of catheter dislodgement

    Any incidence of catheter dislodgement during labour will be recorded.

    Measured: 24 hours

  8. Motor block using Bromage scale

    Bromage scale will be recorded hourly as standard practice.

    • 3: Unable to move feet or knees
    • 2: Able to move feet only
    • 1: Able to just move knees
    • 0: Full flexion of knees and feet

    Measured: 24 hours

  9. Presence of paresthesia on insertion.

    Any presence of paresthesia on insertion will be recorded.

    Measured: 1 hour

  10. Adequacy of conversion to surgical block if required for cesarean delivery: questionnaire

    Adequacy of conversion to surgical block in cases requiring cesarean deliveries for failed labor or fetal issues. This will be recorded by the anesthesiologist.

    Measured: 24 hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted30 Jun 2021
  2. Study start23 Nov 2021
  3. Primary completion26 Jul 2024
  4. Study completion27 Jul 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Triple blind
Who is masked
Participant, Investigator, Outcomes assessor
Enrolment
200 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04946032
Sponsor's protocol ID
21-06
Status last verified
Mar 2025
First submitted
25 Jun 2021
Last updated
6 Apr 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing Epidural catheter in people with Labor Pain, run by Samuel Lunenfeld Research Institute, Mount Sinai Hospital at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 6 Apr 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Sensory block level < T10 (time frame: 1 hour). The study lists 5 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Apr 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in