One of the AUB symptoms, heavy menstrual bleeding (HMB), can lead to iron deficiency and iron deficiency anemia and in acute and severe cases, can necessitate emergency medical care. This study's focus is on the symptom of HMB which has a number of benign causes. Read more about this study

Who is it for?
Ages 40 to 50 years, women only
Conditions the study is for
Heavy Menstrual Bleeding
What is being tested?
IUB SEAD
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
9 sitesin 2 countries
Study dates
1 Sep 2021to Jul 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 40 to 50 years
  • Women only
  • No healthy volunteers
  • Adult

Who may be able to join

  • Female subject age 40 to 50 years, inclusive
  • Suffering from the symptom of heavy menstrual bleeding (HMB) from benign causes with no definable organic cause and are candidates for endometrial ablation or surgical treatment.
  • PBAC score of >150 - an average of 2 consecutive screening scores prior to study treatment
  • Are thought to be ovulatory with cyclic predictable onset of menses with a cycle length of 24-38 days.
  • Have either a normal appearing endometrial cavity as assessed by hysteroscopy performed within 90 days of study treatment, or one that is distorted by a FIGO Type 2 submucous leiomyoma ≤3 cm in mean diameter.
  • Have endometrial sampling with normal histology within 6 months of the study procedure.
Show all 17Show fewer
  • Premenopausal status confirmed by FSH level measurement at screening (FSH < 40 IU/L). FSH level measurement will be repeated in case of a borderline result
  • Screening hemoglobin levels >9.0 g/dL
  • Uterine sound measurement of 6.5-12 cm (external os to internal fundus)
  • Negative serum pregnancy test at the Screening visit and on the day of SEAD™ treatment
  • women whose sexual activity places them at risk for pregnancy must agree to use an effective, non-hormonal, non-intrauterine method of contraception throughout the course of the study. For this study, acceptable effective methods of contraception are considered to be those listed below:
  • Barrier method, i.e., (a) condom (male or female) with spermicide or (b) diaphragm with spermicide or
  • Vasectomy (partner), or
  • Abstinence, if in line with the preferred and usual lifestyle of the subject [where abstinence is defined as refraining from heterosexual intercourse]
  • Subject is able to understand and sign a written informed consent form
  • Subject is willing and able to comply with scheduled visits, treatment plan, laboratory tests, and other study procedures
  • The subject demonstrates an understanding of how to record menstrual blood loss using a menstrual pictogram

Who cannot join

  • Pregnant women or those who desire to conceive at any time in the future
  • An endometrial cavity with any of the following: congenital malformation of (eg septate uterus), endometrial polyp >8 mm in largest dimension, FIGO Type 0 or 1 leiomyomas of any diameter or Type 2 leiomyomas > 3 cm in mean diameter; intrauterine adhesions/ synechiae that distort the endometrial cavity sufficient to impair deployment of the SEAD device.
  • Underwent prior uterine surgery that interrupts the integrity of the uterine wall (e.g., transmural abdominal (laparoscopic or laparotomic) or hysteroscopic myomectomy and/or metroplasty during last 3 months prior to screening, classical Cesarean section, or endometrial ablation
  • Have an abnormal endometrial biopsy that suggests either anovulation or a risk for the development of endometrial cancer (i.e., benign hyperplasia, endometrial hyperplasia with atypia, endometrial intraepithelial neoplasia, endometrial cancer)
  • Have a documented clinical history of titanium allergy or hypersensitivity
  • Suffers from active endometritis, active pelvic inflammatory disease (PID) or active sexually transmitted disease (STD)
Show all 19Show fewer
  • Suffers from active infection of the genitals, vagina, cervix, or uterus
  • Presence of bacteremia, sepsis, or other active systemic infection
  • Known/suspected abdominal, pelvic, or gynecological malignancy within the past 5 years
  • Known clotting defects or bleeding disorders
  • Currently using anticoagulant treatment
  • Subjects with abnormal Papanicolaou (Pap) test or atypical squamous cells of undetermined significance (ASCUS) with positive high-risk human papilloma virus (HPV) test result within the appropriate screen timeframe, and prior to SEAD™ treatment. Alternatively, a colposcopy performed prior to SEAD™ treatment, that showed evidence of dysplasia requiring treatment. In case treatment was performed > 6 months prior to enrollment and follow-up was done with no evidence of disease by clinical evaluation, the subject is eligible.
  • Suffers from clinically significant adenomyosis indicated by subject complaints or imaging
  • Presence of an implantable contraceptive device, unless subject agrees to have the device removed immediately on screening, and prior to PBLAC assessment
  • Post-partum ≤ 6-months
  • Currently participating in or considering participation in a research study of an investigational drug or device that would begin during the course of this investigational study
  • Any general health or mental, or other situation or condition which, in the opinion of the Investigator, could present an increased risk for the subject or impact the subject's ability to comply with protocol requirements.
  • Has a polyp that was not removed before day of treatment
  • Has a BMI>35

Trial locations and contacts

9 sites in 2 countries.

Oshri Barel, Md contact

08-3004100

oshrib@assuta.co.il

Sergio Haimovich, Md contact

072-215-0105

sergio@oconmed.com

9 sites in 2 countries

Israel5 sites, 3 recruiting
  • Barzilai MC

    Ashkelon

    Active, not recruiting
  • Soroka MC

    Beersheba

    Reli Hershkovitz, Prof.

    Recruiting
  • Shamir medical center

    Rishon LeZiyyon

    Noam Smorjick, MD

    Not yet recruiting
  • Ziv medical center

    Safed

    Inbar Ben Shachar, MD

    Recruiting
  • Tzafon MC (Poriya Baruch Padeh)

    Tiberias

    Active, not recruiting

Other trials in Israel

Georgia4 sites
  • Imedi Clinic

    Tbilisi

    Active, not recruiting
  • In Vitro Clinic - Leadermed

    Tbilisi

    Active, not recruiting
  • Medinvest

    Tbilisi

    Active, not recruiting
  • Zurab Sabakhtarashvili Reproductive Clinic

    Tbilisi

    Active, not recruiting

Other trials in Georgia

About this study

Official title: PHASE IIB PRE-PIVOTAL STUDY TO ASSESS THE SAFETY AND EFFICACY OF THE IUB SEAD DEVICE IN WOMEN SUFFERING FROM HEAVY MENSTRUAL BLEEDING (HMB)

One of the AUB symptoms, heavy menstrual bleeding (HMB), can lead to iron deficiency and iron deficiency anemia and in acute and severe cases, can necessitate emergency medical care. This study's focus is on the symptom of HMB which has a number of benign causes.

The investigative device, the IUB SEAD™, is a novel spherical endometrial ablation device developed to allow for simple, office-based chemical EA to treat benign causes of the symptom of HMB. The suggested procedure is expected to be simpler than the currently available EA methods and yet should still reduce the need for hysterectomy.

Read the detailed description

Chronic abnormal uterine bleeding (AUB), involving menstrual bleeding of abnormal quantity, duration, frequency, or regularity is experienced by 10-50% of women of reproductive age, adversely impacts quality of life and can have substantial adverse economic impacts on patients and healthcare systems. One of the AUB symptoms, heavy menstrual bleeding (HMB), can lead to iron deficiency and iron deficiency anemia and in acute and severe cases, can necessitate emergency medical care. This study's focus is on the symptom of HMB which has a number of benign causes.

While pharmacologic treatment options exist, they are not always effective, and they are frequently associated with both side effects and ongoing cost of care. Consequently, some women desire more definitive options. Endometrial ablation (EA) is a minimally invasive approach designed to manage a number of the causes of HMB and can be performed under direct intrauterine vision with resectoscopic instruments or with a non-resectoscopic approach (non resectoscopic endometrial ablation or NREA). For NREA, one of a number of specially designed device is inserted into the endometrial cavity to deliver thermal, cryogenic or radiofrequency electrical energy in an attempt to destroy the uterine lining or endometrium. In some jurisdictions, NREA has become an accepted office-based procedure, but is still usually performed in an institutional setting, is associated with risks associated with the procedure, anesthesia, and subsequent infertility, and has a failure rate that is averages about 26%. These devices are typically expensive and require training for both the surgeon and the ancillary support staff.

The investigative device, the IUB SEAD™, is a novel spherical endometrial ablation device developed to allow for simple, office-based chemical EA to treat benign causes of the symptom of HMB. The suggested procedure is expected to be simpler than the currently available EA methods and yet should still reduce the need for hysterectomy.

Being tested
IUB SEAD
Medical subject headings
Menorrhagia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • IUB SEADDevice

    The investigative device, the IUB SEAD™, is a novel spherical endometrial ablation device developed to allow for simple, office-based chemical EA to treat benign causes of the symptom of HMB

Study groups in NCT04959396
Study groupRoleWhat they receive
TreatmentExperimentalIUB SEAD procedure
Receives: Device: IUB SEAD

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Safety: Incidence and characteristics of device and/or procedure related adverse events

    Incidence and characteristics of device and/or procedure related adverse events (AEs) occurring during the 6-months following SEAD™ device treatment

    Measured: 6 months

  2. Efficacy: Reduction in bleeding volume as measured by Pictorial Blood Loss Assessment Chart (PBAC) at 6 months post-treatment compared to baseline

    Change in bleeding volume as measured by Pictorial Blood Loss Assessment Chart (PBAC) at 6 months post-treatment compared to baseline

    Measured: 6 months

Secondary outcomes (2)
  1. 1. Change from baseline quality of life (QoL) scores, as assessed using the MIQ questionnaire at 6, 12, 24 and 36 months post-treatment.

    Change from baseline quality of life (QoL) scores

    Measured: 36 months

  2. Bleeding volume

    Reduction in bleeding volume

    Measured: 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted13 Jul 2021
  2. Study start1 Sep 2021
  3. Primary completionJan 2025 (estimated)
  4. Study completionJul 2025 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Model description
Endometrium ablation with the IUB SEAD device
Masking
None (open label)
Enrolment
30 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04959396
Sponsor's protocol ID
55P140
Acronym
HMB
Status last verified
Nov 2023
First submitted
26 May 2021
Last updated
9 Nov 2023
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing IUB SEAD in people with Heavy Menstrual Bleeding, run by Ocon Medical Ltd. at 9 sites in 2 countries.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 17 inclusion and 19 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 9 Nov 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 9 sites in Israel, Georgia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Oshri Barel, Md (08-3004100, oshrib@assuta.co.il), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Safety: Incidence and characteristics of device and/or procedure related adverse events (time frame: 6 months). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Nov 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in