Small Bowel DiseaseNCT04959994
Small Bowel Evaluation Using Novel Motorized Spiral Enteroscopy
An observational study of Small Bowel Disease, run by Asian Institute of Gastroenterology, India at 1 site in India.
Trial summary
Small bowel evaluation using Novel Motorized Spiral Enteroscopy - Prospective non-controlled clinical study from a single tertiary care centre. Data regarding the safety and efficacy of Novel Motorized Spiral Enteroscopy in the evaluation of the small bowel, most of them are retrospective. Read more about this study
- Who is it for?
- Ages 10 years and older
- Conditions the study is for
- Small Bowel Disease
- What is being tested?
- Novel Motorized Spiral Enteroscopy
- Type of treatment
- Medical device
- How many people
- 200 participants
- Where
- 1 siteIndia
- Study dates
- 15 Jun 2021to 16 Jun 2022
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 10 years and older
- All sexes
- No healthy volunteers
- Child, Adult, Older adult
Study population: All the patients with suspected small bowel disease satisfying the inclusion criteria and have indications for total enteroscopy will undergo small bowel evaluation using Novel Motorized Spiral Enteroscopy.
Who may be able to join
- Patients with small bowel disease with an indication for Motorized spiral enteroscopy and age more than 10 years
- Overt or obscure Gastrointestinal bleeding
- Iron deficiency anaemia
- Chronic diarrhoea
- Abdominal pain for evaluation with suspected small bowel involvement.
- IBD requiring small bowel evaluation
Show all 9Show fewer
- Polyposis syndrome requiring small bowel evaluation
- Small bowel subacute obstruction
- Refractory celiac disease
Who cannot join
- Weight less than 30 kg
- Large gastric or oesophageal varices
- Any medical contraindication to standard enteroscopy
- Any prior history of gastric , small bowel , large bowel surgery
- Acute obstruction of small bowel
- Suspected GI perforation
- Any contraindication for general anaesthesia
- Lack of informed consent.
Trial locations and contacts
1 site in 1 country.
India1 site, 1 recruiting
- Recruiting
Aniruddha Pratap Singh
Hyderabad, Telangana, 500089
Aniruddha P Singh, MBBS,MD,DM, 09004093248, draniruddhapratapsingh@gmail.com
About this study
Official title: Small Bowel Evaluation Using Novel Motorized Spiral Enteroscopy - Prospective Non-controlled Clinical Study From a Single Tertiary Care Centre.
Small bowel evaluation using Novel Motorized Spiral Enteroscopy - Prospective non-controlled clinical study from a single tertiary care centre.
Data regarding the safety and efficacy of Novel Motorized Spiral Enteroscopy in the evaluation of the small bowel, most of them are retrospective. This study is being planned to collect the data prospectively for all the patients undergoing this procedure at our center including the follow up at 1 month for any adverse events.This will enlighten us in understanding the role of Novel Motorized Spiral in the evaluation of the small bowel Enteroscopy in the small bowel evaluation.
Read the detailed description
- Introduction Few studies have been published till now regarding the safety and efficacy of Novel Motorized Spiral Enteroscopy in the evaluation of the small bowel, most of them are retrospective. This study is being planned to collect the data prospectively for all the patients undergoing this procedure at our centre including the follow up at 1 month for any adverse events. This will help us to develop our understanding the role of Novel Motorized Spiral Enteroscopy in the small bowel evaluation.
- Rationale Prospective study evaluating the efficacy of the Novel Motorized Spiral Enteroscopy is lacking. This study will help in understanding the efficacy and safety of the procedure in the evaluation of the small bowel diseases.
- Study Population All the patients who will undergo small bowel evaluation using Novel Motorized Spiral Enteroscopy at AIG Hospitals, Gachibowli, Hyderabad, Telangana, India
- Methodology Patients with suspected small bowel disease with an indication for total enteroscopy will undergo Novel Motorized Spiral Enteroscopy at AIG hospitals. Patient record including the Demographic details, Indications, Pre-Anaesthesia evaluation, History of any previous surgery or prior enteroscopy. Procedure technical success, Total enteroscopic small bowel evaluation rate or extent of examination. Therapeutic procedure underwent, Total Procedure time, Diagnosis, Recovery from anaesthesia time record will be maintained. All the patients will be followed up telephonically for any possible adverse event upto 30 days.
Patient details will be recorded in a proforma after taking proper informed consent.
4a. Inclusion Criteria
- Patients with small bowel disease with an indication for Motorized spiral enteroscopy
- Overt or obscure Gastrointestinal bleeding
- Iron deficiency anaemia
- Chronic diarrhoea
- Abdominal pain for evaluation with suspected small bowel involvement.
- IBD requiring small bowel evaluation
- Polyposis syndrome requiring small bowel evaluation
- Small bowel subacute obstruction
- Refractory celiac disease
4b. Exclusion criteria
- Weight less than 30 kg
- Large gastric or oesophageal varices
- Any medical contraindication to standard enteroscopy
- Any prior history of gastric , small bowel , large bowel surgery
- Acute obstruction of small bowel
- Suspected GI perforation
- Any contraindication for general anaesthesia
- Lack of informed consent.
4c. Subject recruitment All the patients who will undergo the procedure according to the inclusion and exclusion criteria will be taken. Prospectively their records will be maintained by proforma at AIG hospitals, Gachibowli.
4d. Randomization and blinding - NIL Single group assignment with no randomization
4e. Method of assessment This will be a non- controlled single group assignment study,All antegrade power spiral enteroscopy procedures will be performed under elective general anesthesia with nasotracheal intubation.Retrograde power spiral enteroscopy procedures will be performed under deep sedation using propofol.A prophylactic wire guided dilatation using Savary - Gilliard dilator up to 20 mm will be done in all the patients. After the maximal depth of insertion via the antegrade route hemoclip or Indiaink will be applied to mark the maximal depth of insertion and retrograde enteroscopy will be done to try to trace the hemoclip on the same or the next day to obtain total enteroscopy.
4f. Stopping or discontinuation criteria- None
- Sample size calculation All the patients who will undergo Novel Motorized Spiral Enteroscopy will be recorded in a proforma and their follow up at 30 days will be assessed telephonically for a duration of 1 year
- Statistical analysis The database will be created with Microsoft Excel (Microsoft, Seattle, Wash, USA). Data entry will be done by primary investigator using google forms and it will be stored with the primary investigator. Statistical analyses will be done using SPSS version 25 (IBM Corp., Armonk, NY, USA). Continuous measures will be expressed with sample size, mean (standard deviation), median (range), as and when required. Categorical measures will be presented as number of patients and percentage. The 95% confidence interval will be calculated using exact Clopper-Pearson for diagnostic yield and TER.
- Ethical justification of the study This is a prospective nonrandomized non-controlled trial with patients not assigned to any specific intervention.
- Conditions
- Small Bowel Disease
- Being tested
- Novel Motorized Spiral Enteroscopy
- Keywords
- Small bowel disease, Deep enteroscopy
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Novel Motorized Spiral EnteroscopyDevice
All the patients with suspected small bowel disease and an indication to undergo total enteroscopy and satisfying inclusion criteria will undergo novel motorized spiral enteroscopy
What is being measured
The primary outcome is the main question the study is designed to answer.
Total enteroscopy rate with motorized spiral enteroscopy both via antegrade and the retrograde route.
Rate of examining the total small bowel evaluation using novel motorized spiral enteroscopy
Measured: 2 days
Secondary outcomes (6)
Technical success of antegrade and the retrograde approach
Passage of the scope at least till the duodenojejunal flexure
Measured: 2 days
Total procedural time
Total procedural time beginning from the ligament of trietz to the maximal depth of the insertion via antegrade route and passage of the scope from the ileocecal valve to the maximal depth of the insertion via the retrograde route
Measured: 2 days
Depth of the maximal insertion
Maximal depth of the insertion beyond the ligament of Trietz via the antegrade route and beyond the Ileocecal valve via the retrograde route.
Measured: 2 days
Diagnostic yield
Diagnostic yield, defined as the percentage of procedures with a definitive endoscopic diagnosis (either confirmed a diagnosis from previous imaging or new diagnosis at the anatomic location identified in previous imaging studies).
Measured: 2 days
Therapeutic yield
Therapeutic yield, defined as the percentage of any therapeutic procedures done excluding biopsy and hemoclip application to mark the maximal depth of insertion.
Measured: 2 days
Adverse events
Any adverse events including minor or major which may require surgical intervention or ICU admission
Measured: 30 days
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 Jul 2021
- Study start15 Jun 2021
- Primary completion16 Jun 2022 (estimated)
- Study completion16 Jun 2022 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (3)Papers the sponsor has linked to this study.
- Other trials for Small Bowel DiseaseStudies of the same condition, open and under way.
- More trials run by Asian Institute of Gastroenterology, IndiaThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 200 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Asian Institute of Gastroenterology, India
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Aniruddha P Singh, MBBS,MD,DM, Principal investigator, AIG hospitals,IndiaMohan Ramchandani, MBBS,MD,DM, Study director, AIG Hospitals,IndiaDuvur Nageshwar Reddy, Study chair, AIG Hospitals,India
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04959994
- Sponsor's protocol ID
- AIG/IEC-BH&R 15/06.2021-01
- Status last verified
- Apr 2022
- First submitted
- 2 Jul 2021
- Last updated
- 5 May 2022
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Beyna T, Arvanitakis M, Schneider M, Gerges C, Hoellerich J, Deviere J, Neuhaus H. Total motorized spiral enteroscopy: first prospective clinical feasibility trial. Gastrointest Endosc. 2021 Jun;93(6):1362-1370. doi: 10.1016/j.gie.2020.10.028. Epub 2020 Nov 2.
PubMed 33144239Beyna T, Arvanitakis M, Schneider M, Gerges C, Boing D, Deviere J, Neuhaus H. Motorised spiral enteroscopy: first prospective clinical feasibility study. Gut. 2021 Feb;70(2):261-267. doi: 10.1136/gutjnl-2019-319908. Epub 2020 Apr 24.
PubMed 32332141Ramchandani M, Rughwani H, Inavolu P, Singh AP, Tevethia HV, Jagtap N, Sekaran A, Kanakagiri H, Darishetty S, Reddy DN. Diagnostic yield and therapeutic impact of novel motorized spiral enteroscopy in small-bowel disorders: a single-center, real-world experience from a tertiary care hospital (with video). Gastrointest Endosc. 2021 Mar;93(3):616-626. doi: 10.1016/j.gie.2020.07.001. Epub 2020 Jul 12.
PubMed 32663489
Study at a glance
From the registry record, last updated by the sponsor on 5 May 2022. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Small Bowel Evaluation Using Novel Motorized Spiral Enteroscopy - Prospective Non-controlled Clinical Study From a Single Tertiary Care Centre.
- ClinicalTrials.gov ID
- NCT04959994
- Acronym / sponsor ID
- AIG/IEC-BH&R 15/06.2021-01
- Conditions
- Small Bowel Disease
- Keywords
- Small bowel disease, Deep enteroscopy
- Study type
- Observational
- Recruitment status
- Unknown status
- Enrolment
- 200 participants (estimated)
- Lead sponsor
- Asian Institute of Gastroenterology, IndiaUniversity, hospital or other
- Study start
- 15 Jun 2021 (actual)
- Primary completion
- 16 Jun 2022 (estimated)
- Study completion
- 16 Jun 2022 (estimated)
- First posted
- 13 Jul 2021 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Small bowel evaluation using Novel Motorized Spiral Enteroscopy - Prospective non-controlled clinical study from a single tertiary care centre.
Data regarding the safety and efficacy of Novel Motorized Spiral Enteroscopy in the evaluation of the small bowel, most of them are retrospective. This study is being planned to collect the data prospectively for all the patients undergoing this procedure at our center including the follow up at 1 month for any adverse events.This will enlighten us in understanding the role of Novel Motorized Spiral in the evaluation of the small bowel Enteroscopy in the small bowel evaluation.
Detailed description
- Introduction Few studies have been published till now regarding the safety and efficacy of Novel Motorized Spiral Enteroscopy in the evaluation of the small bowel, most of them are retrospective. This study is being planned to collect the data prospectively for all the patients undergoing this procedure at our centre including the follow up at 1 month for any adverse events. This will help us to develop our understanding the role of Novel Motorized Spiral Enteroscopy in the small bowel evaluation.
- Rationale Prospective study evaluating the efficacy of the Novel Motorized Spiral Enteroscopy is lacking. This study will help in understanding the efficacy and safety of the procedure in the evaluation of the small bowel diseases.
- Study Population All the patients who will undergo small bowel evaluation using Novel Motorized Spiral Enteroscopy at AIG Hospitals, Gachibowli, Hyderabad, Telangana, India
- Methodology Patients with suspected small bowel disease with an indication for total enteroscopy will undergo Novel Motorized Spiral Enteroscopy at AIG hospitals. Patient record including the Demographic details, Indications, Pre-Anaesthesia evaluation, History of any previous surgery or prior enteroscopy. Procedure technical success, Total enteroscopic small bowel evaluation rate or extent of examination. Therapeutic procedure underwent, Total Procedure time, Diagnosis, Recovery from anaesthesia time record will be maintained. All the patients will be followed up telephonically for any possible adverse event upto 30 days.
Patient details will be recorded in a proforma after taking proper informed consent.
4a. Inclusion Criteria
- Patients with small bowel disease with an indication for Motorized spiral enteroscopy
- Overt or obscure Gastrointestinal bleeding
- Iron deficiency anaemia
- Chronic diarrhoea
- Abdominal pain for evaluation with suspected small bowel involvement.
- IBD requiring small bowel evaluation
- Polyposis syndrome requiring small bowel evaluation
- Small bowel subacute obstruction
- Refractory celiac disease
4b. Exclusion criteria
- Weight less than 30 kg
- Large gastric or oesophageal varices
- Any medical contraindication to standard enteroscopy
- Any prior history of gastric , small bowel , large bowel surgery
- Acute obstruction of small bowel
- Suspected GI perforation
- Any contraindication for general anaesthesia
- Lack of informed consent.
4c. Subject recruitment All the patients who will undergo the procedure according to the inclusion and exclusion criteria will be taken. Prospectively their records will be maintained by proforma at AIG hospitals, Gachibowli.
4d. Randomization and blinding - NIL Single group assignment with no randomization
4e. Method of assessment This will be a non- controlled single group assignment study,All antegrade power spiral enteroscopy procedures will be performed under elective general anesthesia with nasotracheal intubation.Retrograde power spiral enteroscopy procedures will be performed under deep sedation using propofol.A prophylactic wire guided dilatation using Savary - Gilliard dilator up to 20 mm will be done in all the patients. After the maximal depth of insertion via the antegrade route hemoclip or Indiaink will be applied to mark the maximal depth of insertion and retrograde enteroscopy will be done to try to trace the hemoclip on the same or the next day to obtain total enteroscopy.
4f. Stopping or discontinuation criteria- None
- Sample size calculation All the patients who will undergo Novel Motorized Spiral Enteroscopy will be recorded in a proforma and their follow up at 30 days will be assessed telephonically for a duration of 1 year
- Statistical analysis The database will be created with Microsoft Excel (Microsoft, Seattle, Wash, USA). Data entry will be done by primary investigator using google forms and it will be stored with the primary investigator. Statistical analyses will be done using SPSS version 25 (IBM Corp., Armonk, NY, USA). Continuous measures will be expressed with sample size, mean (standard deviation), median (range), as and when required. Categorical measures will be presented as number of patients and percentage. The 95% confidence interval will be calculated using exact Clopper-Pearson for diagnostic yield and TER.
- Ethical justification of the study This is a prospective nonrandomized non-controlled trial with patients not assigned to any specific intervention.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
Who may qualify
- Ages
- 10 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child, Adult, Older adult
- Study population
- All the patients with suspected small bowel disease satisfying the inclusion criteria and have indications for total enteroscopy will undergo small bowel evaluation using Novel Motorized Spiral Enteroscopy.
Key inclusion criteria (9 listed)
- Patients with small bowel disease with an indication for Motorized spiral enteroscopy and age more than 10 years
- Overt or obscure Gastrointestinal bleeding
- Iron deficiency anaemia
- Chronic diarrhoea
- Abdominal pain for evaluation with suspected small bowel involvement.
Key exclusion criteria (8 listed)
- Weight less than 30 kg
- Large gastric or oesophageal varices
- Any medical contraindication to standard enteroscopy
- Any prior history of gastric , small bowel , large bowel surgery
- Acute obstruction of small bowel
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Novel Motorized Spiral EnteroscopyAll the patients with suspected small bowel disease and an indication to undergo total enteroscopy and satisfying inclusion criteria will undergo novel motorized spiral enteroscopy | Device | – |
Primary outcome
Total enteroscopy rate with motorized spiral enteroscopy both via antegrade and the retrograde route.
Time frame: 2 days
Rate of examining the total small bowel evaluation using novel motorized spiral enteroscopy
6 secondary outcomes
Technical success of antegrade and the retrograde approach
Time frame: 2 days
Total procedural time
Time frame: 2 days
Depth of the maximal insertion
Time frame: 2 days
Diagnostic yield
Time frame: 2 days
Therapeutic yield
Time frame: 2 days
Adverse events
Time frame: 30 days
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 5 May 2022.
- Results publication: PubMed 33144239Beyna T, Arvanitakis M, Schneider M, Gerges C, Hoellerich J, Deviere J, Neuhaus H. Total motorized spiral enteroscopy: first prospective clinical feasibility trial. Gastrointest Endosc. 2021 Jun;93(6):1362-1370. doi: 10.1016/j.gie.2020.10.028. Epub 2020 Nov 2.
- Results publication: PubMed 32332141Beyna T, Arvanitakis M, Schneider M, Gerges C, Boing D, Deviere J, Neuhaus H. Motorised spiral enteroscopy: first prospective clinical feasibility study. Gut. 2021 Feb;70(2):261-267. doi: 10.1136/gutjnl-2019-319908. Epub 2020 Apr 24.
- Results publication: PubMed 32663489Ramchandani M, Rughwani H, Inavolu P, Singh AP, Tevethia HV, Jagtap N, Sekaran A, Kanakagiri H, Darishetty S, Reddy DN. Diagnostic yield and therapeutic impact of novel motorized spiral enteroscopy in small-bowel disorders: a single-center, real-world experience from a tertiary care hospital (with video). Gastrointest Endosc. 2021 Mar;93(3):616-626. doi: 10.1016/j.gie.2020.07.001. Epub 2020 Jul 12.
- Individual participant dataSharing planned: No
Related trials for Small Bowel Disease
Enrolling by invitationPhase 2
Herbal Supplement (Biocidin REMOVE) for Bacterial Overgrowth in Irritable Bowel Syndrome
Irritable Bowel Syndrome (IBS), Small Intestinal Bacterial Overgrowth Syndrome (SIBO)
RecruitingPhase 1/2
A Phase 1 and 2 Study of VMD-102 in Hepatocellular Carcinoma and Other Solid Tumors
Hepatocellular Carcinoma (HCC), Metastatic Uveal Melanoma
RecruitingPhase 1/2
Phase 1/2, Open-label Study of ETX-929, a KRAS Inhibitor in Participants With Advanced Solid Tumors
Metastatic Colorectal Cancer (CRC), Pancreatic Ductal Adenocarcinoma (PDAC)
RecruitingPhase 1
A Phase 1 Study of IM-1617 in Participants With Advanced Cancer
Colorectal Cancer, Non-Small Cell Lung Cancer
Active, not recruitingPhase 1
Safety and Tolerability of IPH4502 in Patients With Advanced Solid Tumors
Advanced or Metastatic Solid Tumors
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Aniruddha P Singh, MBBS,MD,DM principal investigator
AIG hospitals,India
Mohan Ramchandani, MBBS,MD,DM study director
AIG Hospitals,India
Duvur Nageshwar Reddy study chair
AIG Hospitals,India
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Small Bowel Disease, run by Asian Institute of Gastroenterology, India at 1 site in India.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 9 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 5 May 2022. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in India. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Aniruddha P Singh, MBBS,MD,DM (09004093248, draniruddhapratapsingh@gmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Total enteroscopy rate with motorized spiral enteroscopy both via antegrade and the retrograde route. (time frame: 2 days). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT04959994, which also lists 3 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 5 May 2022.