AzTrials
AzTrials

Cataract ExtractionNCT04977102

A Randomized Study of Intraocular Caliper-assisted Capsulotomy for Age-related Cataract Patients With Corneal Limbus Opacity

A study testing Intraocular caliper-assisted capsulotomy and Verion navigation system-assisted capsulotomy in people with Cataract Extraction, run by Zhongshan Ophthalmic Center, Sun Yat-sen University at 1 site in China.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The purpose of this study is to compare the accuracy of capsulotomy assisted by intraocular caliper and Verion navigation system in phacoemulsification surgery and postoperative visual quality for age-related cataract patients with corneal limbus opacity. Read more about this study

Who is it for?
Ages 55 to 80 years
Conditions the study is for
Cataract Extraction
What is being tested?
Intraocular caliper-assisted capsulotomy and Verion navigation system-assisted capsulotomy
Could I receive a placebo?
No, everyone receives an active treatment
How many people
74 participants
Where
1 siteChina
Study dates
1 Aug 2021to 31 Oct 2022
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 55 to 80 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Adults aged 55 to 80 years with age-related cataract with pterygium, Corneal geriatric ring, and corneal limbus opacity;
  • Pupil diameter ≥ 6.5mm after pupil dilation;
  • Lens nuclear opacity grading score (LOCS III) lower than 4.0.

Who cannot join

  • Patients had previous intraocular surgery;
  • Patients with a diagnosed eye disease that may affect the functions of lens suspensory ligament such as previous ocular trauma, lens subluxation, pseudoexfoliation syndrome, retinal pigment degeneration;
  • Patients had other ocular diseases that impair visual function include optic neuropathy, uveitis, and tumor.
  • Refused to participate the study.

Trial locations and contacts

1 site in 1 country.

Xiaoyun Chen, PhD contact

+86 13632343642

chenxiaoyun@gzzoc.com

China1 site
  • Zhongshan Ophthalmic Center, Sun Yat-sen University

    Guangzhou, 510060

    Xiaoyun Chen, PhD, +86 13632343642, chenxiaoyun@gzzoc.com

Other trials in China

About this study

Official title: A Randomized Controlled Trial Comparing Intraocular Caliper-assisted Capsulotomy Versus Verion Navigation System-assisted Capsulotomy for Age-related Cataract With Corneal Limbus Opacity

The purpose of this study is to compare the accuracy of capsulotomy assisted by intraocular caliper and Verion navigation system in phacoemulsification surgery and postoperative visual quality for age-related cataract patients with corneal limbus opacity.

Read the detailed description

Continuous curvilinear capsulorhexis (CCC) is an important and technically challenging procedure in cataract surgery. Too large or too small capsulorhexis can increase the incidence of intraoperative and postoperative complications.

In recent years, the image projection device Verion navigation system has been reported that it can improve the repeatability and accuracy of capsulorhexis via projecting a pre-set size ring to guide capsulorhexis. However, we found that for the patients with corneal geriatric ring, pterygium or limbal lesions leading to unclear limbal boundary, the projected capsulorhexis will deviate from the center, resulting in capsulorhexis is off center in clinical practice. Our self-developed intraocular caliper, which is modified on the conventional intraocular irrigation needle, can accurately measure the size of capsulorhexis, and mark the position and boundary of capsulorhexis on the lens anterior capsule to guide capsulorhexis, thus significantly improves the accuracy and centricity of capsulorhexis.

The purpose of this study is to compare the centricity and accuracy of intraocular caliper-assisted capsulorhexis in phacoemulsification for age-related cataract patients with corneal limbus opacity with that of Verion projection navigation system.

Being tested
Intraocular caliper-assisted capsulotomy, Verion navigation system-assisted capsulotomy

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Intraocular caliper-assisted capsulotomyProcedure or surgery

    Intraocular caliper is a modified intraocular caliper with standard calibration on the rinse needle.

  • Verion navigation system-assisted capsulotomyProcedure or surgery

    Verion Image Guided System (Alcon Laboratories, Inc.) is a digital image guidance system consisting of a diagnostic reference unit and a surgery pilot for intraoperative surgical assistance. The device can be used to align toric intraocular lens during surgery as well as support manual creation of a capsulorhexis with a predefined target diameter.

Study groups in NCT04977102
Study groupRoleWhat they receive
Intraocular caliper-assisted capsulotomy groupExperimentalIn intraocular caliper-assisted capsulotomy group, a modified intraocular caliper with standard calibration on the rinse needle was used to measure and locate the position of capsulorhexis with 5.3 mm diameter and the principle of pupillary margin in concentric circles. The surgeon could gently use the blunt needle in the front of the intraocular caliper to further make corresponding markers on the lens anterior capsule, and then carry out capsulotomy according to the marks.
Receives: Procedure: Intraocular caliper-assisted capsulotomy
Verion navigation system-assisted capsulotomy groupActive comparatorIn the Verion-assisted capsulotomy group, Verion navigation system was applied to project a 5.3 mm capsulorhexis centered on the corneal vertex. According to the projected capsulorhexis, capsulotomy was performed.
Receives: Procedure: Verion navigation system-assisted capsulotomy

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Distance between pupil center and capsulorhexis center

    The primary outcome was the distance between pupil center and capsulorhexis center. Clear images of the edges of IOL and capsulorhexis were taken at the end of the operation, and Image J image analysis software is used to measure the distance between pupil center and capsulorhexis center with the diameter of IOL optical surface (6 mm) as the reference by two independently professional graders at the meantime.

    Measured: During the surgery

Secondary outcomes (9)
  1. Uncorrected and corrected visual acuity

    Evaluated with ETDRS visual acuity chart.

    Measured: One month after surgery

  2. Ideal ratio of capsulorhexis

    Ideal capsulorhexis is defined as a centered and round capsulorhexis , which can cover the edge of IOL optical surface continuously for 360 degrees with a diameter between 5.0 to 5.5 mm.

    Measured: During the surgery

  3. Grades of capsulorhexis-IOL overlap

    The capsulorhexis-IOL overlap of each patient was graded as 360-degree continuous overlap, 270~360-degree overlap, 180~270-degree overlap, 90~180-degree overlap, and < 90-degree overlap.

    Measured: During the surgery

  4. Deviation of horizontal and vertical diameter of capsulorhexis from the target diameter (5.3 mm)

    Measured by Image J image analysis software.

    Measured: During the surgery

  5. Horizontal and vertical diameter of capsulorhexis

    Measured by Image J image analysis software.

    Measured: During the surgery

  6. Intraocular lens tilt

    Measured by anterior segment OCT (CASIA2).

    Measured: One month after surgery

  7. Intraocular lens decentration

    Measured by anterior segment OCT (CASIA2).

    Measured: One month after surgery

  8. Intraocular aberrations

    Measured by OPD-SCAN III.

    Measured: One month after surgery

  9. Distance between pupil center and capsulorhexis center

    Measured: One month after surgery

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted26 Jul 2021
  2. Study start1 Aug 2021 (estimated)
  3. Primary completion31 Jul 2022 (estimated)
  4. Study completion31 Oct 2022 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
74 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04977102
Sponsor's protocol ID
2021KYPJ111
Status last verified
Jul 2021
First submitted
16 Jul 2021
Last updated
26 Jul 2021
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing Intraocular caliper-assisted capsulotomy and Verion navigation system-assisted capsulotomy in people with Cataract Extraction, run by Zhongshan Ophthalmic Center, Sun Yat-sen University at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 26 Jul 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Xiaoyun Chen, PhD (+86 13632343642, chenxiaoyun@gzzoc.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Distance between pupil center and capsulorhexis center (time frame: During the surgery). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 26 Jul 2021.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in