Severe, Symptomatic Aortic StenosisNCT04982588
Evolut PRO China Clinical Study
A study testing Medtronic CoreValve™ Evolut™ PRO System in people with Severe, Symptomatic Aortic Stenosis, run by Medtronic Cardiovascular at 4 sites in China.
Trial summary
Interventional study to evaluate the safety and efficacy of the Medtronic CoreValve™ Evolut™ PRO System when used by China implanting centers in Chinese patients with severe symptomatic aortic stenosis (AS) who are at high risk for Surgical Aortic Valve Replacement (SAVR). Read more about this study
- Who is it for?
- Ages 65 years and older
- Conditions the study is for
- Severe, Symptomatic Aortic Stenosis
- What is being tested?
- Medtronic CoreValve™ Evolut™ PRO System
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 52 participants
- Where
- 4 sitesChina
- Study dates
- 17 Jul 2021to 15 May 2028
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 65 years and older
- All sexes
- No healthy volunteers
- Older adult
Who may be able to join
- Aortic valve area (AVA) < 1.0 cm2 (or indexed AVA <0.6 cm2/m2) OR mean gradient > 40 mmHg, OR max aortic velocity > 4.0 m/sec
- High risk for SAVR defined as STS-PROM score ≥ 8% AND ≤ 15%, OR documented Heart Team agreement of high risk for AVR due to frailty or comorbidities
- Symptoms of aortic stenosis and NYHA ≥ II
Who cannot join
- Age is less than 65 years old
- Non-calcified aortic valve
- Bicuspid aortic valve with no raphe or 2 raphes (Sievers classification type 0 or type 2)
- Ascending aortic diameter > 4.5 cm
Trial locations and contacts
4 sites in 1 country.
China4 sites
Beijing Anzhen Hospital, Capital Medical University
Beijing, Beijing Municipality, 100000
Chinese PLA General Hospital, Chinese PLA Medical School
Beijing, Beijing Municipality, 100000
West China Hospital of Sichuan University
Chengdu, Sichuan, 610000
The Second Affiliated Hospital Zhejiang University School of Medicine
Hangzhou, Zhejiang, 310009
About this study
Official title: Medtronic CoreValve™ Evolut™ PRO System China Clinical Study
Interventional study to evaluate the safety and efficacy of the Medtronic CoreValve™ Evolut™ PRO System when used by China implanting centers in Chinese patients with severe symptomatic aortic stenosis (AS) who are at high risk for Surgical Aortic Valve Replacement (SAVR).
Read the detailed description
The study is targeting 6 centers with a maximum of 8 centers in China and estimating 65 subjects with a maximum of up to 70 subjects with attempted implants including 50 subjects with an attempted implant in primary study population and the first two attempted subjects at each site for roll-in population. The subjects will follow the assessment with pre and post-procedure, discharge, 30 days(primary endpoint), 6 months, 1 year, and annually through 5 years.
- Conditions
- Severe, Symptomatic Aortic Stenosis
- Being tested
- Medtronic CoreValve™ Evolut™ PRO System
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Medtronic CoreValve™ Evolut™ PRO SystemDevice
The system comprised of the following three components:
- CoreValve™ Evolut™ PRO Transcatheter Aortic Valve (TAV)
- EnVeo™ PRO Delivery Catheter System (DCS)
- EnVeo™ PRO Loading System (LS)
| Study group | Role | What they receive |
|---|---|---|
| Medtronic CoreValve™ Evolut™ PRO System | Experimental | The system comprised of the following three components:
1. CoreValve™ Evolut™ PRO Transcatheter Aortic Valve (TAV)
2. EnVeo™ PRO Delivery Catheter System (DCS)
3. EnVeo™ PRO Loading System (LS) Receives: Device: Medtronic CoreValve™ Evolut™ PRO System |
What is being measured
The primary outcome is the main question the study is designed to answer.
All-cause Mortality
All-cause mortality at 30 days
Measured: 30 days
Percentage (%) of Subjects With Evaluable Echocardiograms With Moderate or Severe Aortic Regurgitation by Transthoracic Echocardiography (TTE)
Percentage (%) of Subjects with evaluable echocardiograms with moderate or severe aortic regurgitation by transthoracic echocardiography (TTE)
Measured: 30 days
Secondary outcomes (7)
Incidence of an VARC II Combined Composite
Incidence of an VARC II combined composite includes the following components:
- All-cause mortality
- All stroke (disabling and non-disabling)
- Life-threatening bleeding
- Acute kidney injury: stage 2 or 3 (including renal replacement therapy)
- Coronary artery obstruction requiring intervention
- Major vascular complication
- Valve-related dysfunction requiring repeat procedure (BAV, TAVI, or SAVR)
Measured: 30 days
Event Rates of the Individual Components of the VARC II Composite
Event rate of the individual components listed in the outcome
Measured: 30 days
New Permanent Pacemaker Rate
New permanent pacemaker rate
Measured: 30 days
Device Success Rate
Device success rate:
- Percentage of participants with absence of procedural mortality, AND
- Percentage of participants with correct positioning of a single prosthetic heart valve into the proper anatomical location, AND
- Percentage of participants with intended performance of the prosthetic heart valve, defined as the absence of patient-prosthesis-mismatch and mean aortic valve gradient less than 20 mmHg (or peak velocity <3m/sec), AND absence of moderate or severe prosthetic valve regurgitation
Measured: Between 24 hours and 7 days post procedure
Valve Performance Parameter - Mean Aortic Gradient
Mean aortic gradient
Measured: 30 days
Valve Performance Parameter - Effective Orifice Area
Effective orifice area
Measured: 30 days
Valve Performance Parameter -Degree of Aortic Regurgitation (Transvalvular, Paravalvular, Total)
Degree of aortic regurgitation (transvalvular, paravalvular, total)
Measured: 30 days
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted29 Jul 2021
- Study start17 Jul 2021
- Primary completion17 Mar 2023
- Study completion15 May 2028 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for Severe, Symptomatic Aortic StenosisStudies of the same condition, open and under way.
- More trials run by Medtronic CardiovascularThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 52 participants (actual)
Sponsor and investigators
- Lead sponsor
- Medtronic Cardiovascular
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Jianan Wang, MD, Principal investigator, Second Affiliated Hospital, Zhejiang University, School of Medicine
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04982588
- Sponsor's protocol ID
- MDT18065EVR009
- Status last verified
- Nov 2025
- First submitted
- 8 Jul 2021
- Last updated
- 3 Dec 2025
- Results posted
- Yes, on ClinicalTrials.gov
- FDA-regulated drug
- No
- FDA-regulated device
- No
Study at a glance
From the registry record, last updated by the sponsor on 3 Dec 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Medtronic CoreValve™ Evolut™ PRO System China Clinical Study
- ClinicalTrials.gov ID
- NCT04982588
- Acronym / sponsor ID
- MDT18065EVR009
- Conditions
- Severe, Symptomatic Aortic Stenosis
- Study type
- Interventional
- Recruitment status
- Active, not recruiting
- Enrolment
- 52 participants (actual)
- Lead sponsor
- Medtronic CardiovascularIndustry (pharma, biotech, devices)
- Study start
- 17 Jul 2021 (actual)
- Primary completion
- 17 Mar 2023 (actual)
- Study completion
- 15 May 2028 (estimated)
- First posted
- 29 Jul 2021 (actual)
- Results
- Posted 29 Nov 2024
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Interventional study to evaluate the safety and efficacy of the Medtronic CoreValve™ Evolut™ PRO System when used by China implanting centers in Chinese patients with severe symptomatic aortic stenosis (AS) who are at high risk for Surgical Aortic Valve Replacement (SAVR).
Detailed description
The study is targeting 6 centers with a maximum of 8 centers in China and estimating 65 subjects with a maximum of up to 70 subjects with attempted implants including 50 subjects with an attempted implant in primary study population and the first two attempted subjects at each site for roll-in population. The subjects will follow the assessment with pre and post-procedure, discharge, 30 days(primary endpoint), 6 months, 1 year, and annually through 5 years.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Medtronic CoreValve™ Evolut™ PRO System | Experimental | Device: Medtronic CoreValve™ Evolut™ PRO SystemThe system comprised of the following three components: 1. CoreValve™ Evolut™ PRO Transcatheter Aortic Valve (TAV) 2. EnVeo™ PRO Delivery Catheter System (DCS) 3. EnVeo™ PRO Loading System (LS) |
Who may qualify
- Ages
- 65 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Older adult
Key inclusion criteria (3 listed)
- Aortic valve area (AVA) < 1.0 cm2 (or indexed AVA <0.6 cm2/m2) OR mean gradient > 40 mmHg, OR max aortic velocity > 4.0 m/sec
- High risk for SAVR defined as STS-PROM score ≥ 8% AND ≤ 15%, OR documented Heart Team agreement of high risk for AVR due to frailty or comorbidities
- Symptoms of aortic stenosis and NYHA ≥ II
Key exclusion criteria (4 listed)
- Age is less than 65 years old
- Non-calcified aortic valve
- Bicuspid aortic valve with no raphe or 2 raphes (Sievers classification type 0 or type 2)
- Ascending aortic diameter > 4.5 cm
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Medtronic CoreValve™ Evolut™ PRO SystemThe system comprised of the following three components: 1. CoreValve™ Evolut™ PRO Transcatheter Aortic Valve (TAV) 2. EnVeo™ PRO Delivery Catheter System (DCS) 3. EnVeo™ PRO Loading System (LS) | Device | Medtronic CoreValve™ Evolut™ PRO System |
Primary outcome
All-cause Mortality
Time frame: 30 days
All-cause mortality at 30 days
Percentage (%) of Subjects With Evaluable Echocardiograms With Moderate or Severe Aortic Regurgitation by Transthoracic Echocardiography (TTE)
Time frame: 30 days
Percentage (%) of Subjects with evaluable echocardiograms with moderate or severe aortic regurgitation by transthoracic echocardiography (TTE)
7 secondary outcomes
Incidence of an VARC II Combined Composite
Time frame: 30 days
Event Rates of the Individual Components of the VARC II Composite
Time frame: 30 days
New Permanent Pacemaker Rate
Time frame: 30 days
Device Success Rate
Time frame: Between 24 hours and 7 days post procedure
Valve Performance Parameter - Mean Aortic Gradient
Time frame: 30 days
Valve Performance Parameter - Effective Orifice Area
Time frame: 30 days
Valve Performance Parameter -Degree of Aortic Regurgitation (Transvalvular, Paravalvular, Total)
Time frame: 30 days
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 3 Dec 2025.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
Related trials for Severe, Symptomatic Aortic Stenosis
RecruitingObservational study
PERFECT - Portuguese Evolut Registry Studying the Outcomes of Medtronic Evolut™ FX+ TAVI System by Evaluating an Optimal Care Pathway for TAVI
Severe Symptomatic Aortic Stenosis (Defined as New York Heart Association (NYHA) Class ≥ II)
Active, not recruiting
DurAVR™ THV EU-EFS
Symptomatic Aortic Stenosis, Severe Aortic Valve Stenosis
Enrolling by invitation
ENVISION IDE Trial: Safety and Effectiveness of NAVITOR in Transcatheter Aortic Valve Implantation
Aortic Valve Stenosis, Heart Valve Diseases
Not yet recruiting
Safety and Clinical Performance of the Next-Generation SAFESYNC Transcatheter Heart Valve in Patients With Severe Aortic Stenosis
Aortic Stenosis Senile, Aortic Stenosis Symptomatic
Recruiting
Isolated Surgical Aortic Valve Replacement in Low Risk AS Patients
Aortic Stenosis
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Jianan Wang, MD principal investigator
Second Affiliated Hospital, Zhejiang University, School of Medicine
4 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Medtronic CoreValve™ Evolut™ PRO System in people with Severe, Symptomatic Aortic Stenosis, run by Medtronic Cardiovascular at 4 sites in China.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: under way, not looking for participants, as of the sponsor's last update on 3 Dec 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 4 sites in China. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 29 Nov 2024). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
All-cause Mortality (time frame: 30 days). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.