Lipid Tear Deficiency (Disorder)NCT05003128
Changes in Tear Lipid Layer Thickness After Short Exposure to Light Emitting Diode Displays
A study testing LED screen (InnoLux, Taiwan) in people with Lipid Tear Deficiency (Disorder) and Dry Eye Disease, run by National Cheng-Kung University Hospital at 1 site in Taiwan.
Trial summary
Video display terminals (VDTs) are ubiquitous, and engagement in digital screens has grown substantially across all age groups worldwide. Prolonged exposure to VDTs is associated with the development of various health problems. Read more about this study
- Who is it for?
- Ages 20 to 65 yearsHealthy volunteers can take part
- Conditions the study is for
- Lipid Tear Deficiency (Disorder), Dry Eye Disease
- What is being tested?
- LED screen (InnoLux, Taiwan)
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 60 participants
- Where
- 1 siteTaiwan
- Study dates
- 1 Jul 2020to 22 Aug 2020
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 20 to 65 years
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- generally healthy individuals aged between 20 and 65 years who were willing to participate in the study
Who cannot join
- ages below 20 or over 65 years
- a BCVA score of <0.1 on the Landolt C chart in either eye
- a BCVA difference of >0.2 between the eyes
- a history of ocular diseases or previous ocular surgery
Trial locations and contacts
1 site in 1 country.
About this study
Video display terminals (VDTs) are ubiquitous, and engagement in digital screens has grown substantially across all age groups worldwide. Prolonged exposure to VDTs is associated with the development of various health problems. By now, it is unclear whether transient exposure to VDTs leads to ocular surface changes, especially regarding lipid layer thickness (LLT). This study aim to determine if short-term exposure to light-emitting diodes (LEDs) leads to ocular parameter changes.
This is a prospective, cross-sectional study. Patients were recruited at the National Cheng-Kung University Hospital, a tertiary referral center in southern Taiwan, for examination, including best-corrected visual acuity (BCVA), intraocular pressure (IOP), lipid layer thickness (LLT), and blink rates and patterns before and after watching an LED display for 15 minutes. The estimated result is that the LLT and blink rates will decrease after VDT watching.
Read the detailed description
Video display terminals (VDTs) are ubiquitous, and engagement in digital screens has grown substantially across all age groups worldwide. During the coronavirus disease 2019 (COVID-19) pandemic, lockdowns and increasing demand for digital learning and working have led to more frequent and sustained VDT use. Prolonged exposure to VDTs is associated with the development of various health problems, including psychosocial issues, venous thromboembolism, fatigue, and visual complaints.
Computer vision syndrome (CVS) is one of the most frequently encountered problems among VDT users. CVS comprises several visual and musculoskeletal symptoms resulting from VDT use, such as eye strain, dryness and burning sensation of the eye, blurred vision, and neck and shoulder pain. A major alteration is the development of dry eye disease (DED), occurring in 60 % of those with CVS. Dry eye symptoms, corneal erosions, short tear-film breakup time (BUT), low tear meniscus height, and meibomian gland dysfunction (MGD) are all DED presentations encountered by VDT users. The continuous use of VDTs is an established risk factor for CVS and DED. However, it is unclear whether transient exposure to VDTs leads to ocular surface changes, especially regarding lipid layer thickness (LLT).
This study investigated if the short-term use of light-emitting diode (LED) displays (one type of VDT) changed the ocular parameters, including best-corrected visual acuity (BCVA), intraocular ocular pressure (IOP), the CVS-Questionnaire (CVS-Q) score, the blink rate, the partial blink ratio, and LLT. To our knowledge, this is the first study to focus on the immediate effects of LEDs on the eye.
This prospective clinical study was conducted in the Ophthalmology Department of the National Cheng Kung University Hospital (NCKUH), Tainan, Taiwan. The study was approved by the Institutional Review Board of NCKUH and followed the tenets of the Declaration of Helsinki. Written informed consent was obtained from all the participants.
The inclusion criteria were generally healthy individuals aged between 20 and 65 years who were willing to participate in the study. The exclusion criteria were ages below 20 or over 65 years, a BCVA score of <0.1 on the Landolt C chart in either eye, a BCVA difference of >0.2 between the eyes, and a history of ocular diseases or previous ocular surgery.
Participants were instructed to fill out a basic information form, including their name, sex, age, and contact information. They were also informed to avoid wearing contact lenses for two days before the test. The experiment was conducted on August 22, 2020. For the baseline test, the participants were asked to complete the CVS-Q to assess their CVS. Next was a series of ocular examinations, including BCVA, IOP, LLT, an optical coherence tomography (OCT) scan of the macula, and fundus autofluorescence (FAF) imaging. The LLT and blink rates were measured using the LipiView II Ocular Surface Interferometer following the standard protocol (TearScience, Morrisville, NC, USA). After the examination, the participants watched a short movie on an LED screen (InnoLux, Taiwan) for 15 minutes in a bright room. The viewing distance was approximately 1.5 meters. After the movie ended, the participants were instructed to complete the CVS-Q and undergo the BCVA, IOP, and LLT tests again. The baseline BCVA, IOP, OCT, and FAF images of each participant were reviewed by three NCKUH ophthalmologists to screen for clinically significant ocular pathology.
Statistical analyses were performed using R software version 4.1.0 (R Core Team, Vienna, Austria) and SAS Enterprise Guide (version 9.4; SAS Institute Inc., Cary, NC, USA). Paired t-tests were used to compare the BCVA, IOP, CVS-Q score, LLT, blink rate, and the partial blink ratio before and after watching the LED display. Statistical significance was set at P <0.05.
- Conditions
- Lipid Tear Deficiency (Disorder), Dry Eye Disease
- Being tested
- LED screen (InnoLux, Taiwan)
- Keywords
- Computer vision syndrome, Dry eye disease, Light emitting diode, Lipid layer thickness, Video display terminals
- Medical subject headings
- Dry Eye Syndromes
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
LED screen (InnoLux, Taiwan)Device
Participants watch a short movie on an LED screen (InnoLux, Taiwan) for 15 minutes in a bright room. The viewing distance was approximately 1.5 meters.
| Study group | Role | What they receive |
|---|---|---|
| LED screen | Experimental | Not described Receives: Device: LED screen (InnoLux, Taiwan) |
What is being measured
The primary outcome is the main question the study is designed to answer.
Lipid Layer Thickness
Measured: Change from baseline lipid layer thickness at 15 minutes
Secondary outcomes (4)
Visual Acuity
Measured: Change from baseline visual acuity at 15 minutes
Intraocular Pressure
Measured: Change from baseline intraocular pressure at 15 minutes
Blink rates
Measured: Change from baseline blink rates at 15 minutes
Computer Vision Syndrome Questionnaire Score
The Computer Vision Syndrome Questionnaire is a validated questionnaire to assess the severity of the computer vision syndrome.
Measured: Change from Baseline Computer Vision Syndrome Questionnaire Score at 15 minutes
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted12 Aug 2021
- Study start1 Jul 2020
- Primary completion22 Aug 2020
- Study completion22 Aug 2020
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Lipid Tear Deficiency (Disorder)Studies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 60 participants (actual)
Sponsor and investigators
- Lead sponsor
- National Cheng-Kung University Hospital
- Sponsor type
- University, hospital or other
- Collaborators
- Ministry of Science and Technology, Taiwan
- Responsible party
- Sponsor
- Investigators
- Yi-Hsun Huang, PhD, Study chair, National Cheng-Kung University Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05003128
- Sponsor's protocol ID
- A-ER-108-489
- Status last verified
- Jul 2021
- First submitted
- 29 Jul 2021
- Last updated
- 12 Aug 2021
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No: The informed consent of this study specified that the participants' data would only be used in this study
Study at a glance
From the registry record, last updated by the sponsor on 12 Aug 2021. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Changes in Tear Lipid Layer Thickness After Short Exposure to Light Emitting Diode Displays
- ClinicalTrials.gov ID
- NCT05003128
- Acronym / sponsor ID
- A-ER-108-489
- Conditions
- Lipid Tear Deficiency (Disorder), Dry Eye Disease
- Keywords
- Computer vision syndrome, Dry eye disease, Light emitting diode, Lipid layer thickness, Video display terminals
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 60 participants (actual)
- Lead sponsor
- National Cheng-Kung University HospitalUniversity, hospital or other
- Collaborators
- Ministry of Science and Technology, Taiwan
- Study start
- 1 Jul 2020 (actual)
- Primary completion
- 22 Aug 2020 (actual)
- Study completion
- 22 Aug 2020 (actual)
- First posted
- 12 Aug 2021 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Video display terminals (VDTs) are ubiquitous, and engagement in digital screens has grown substantially across all age groups worldwide. Prolonged exposure to VDTs is associated with the development of various health problems. By now, it is unclear whether transient exposure to VDTs leads to ocular surface changes, especially regarding lipid layer thickness (LLT). This study aim to determine if short-term exposure to light-emitting diodes (LEDs) leads to ocular parameter changes.
This is a prospective, cross-sectional study. Patients were recruited at the National Cheng-Kung University Hospital, a tertiary referral center in southern Taiwan, for examination, including best-corrected visual acuity (BCVA), intraocular pressure (IOP), lipid layer thickness (LLT), and blink rates and patterns before and after watching an LED display for 15 minutes. The estimated result is that the LLT and blink rates will decrease after VDT watching.
Detailed description
Video display terminals (VDTs) are ubiquitous, and engagement in digital screens has grown substantially across all age groups worldwide. During the coronavirus disease 2019 (COVID-19) pandemic, lockdowns and increasing demand for digital learning and working have led to more frequent and sustained VDT use. Prolonged exposure to VDTs is associated with the development of various health problems, including psychosocial issues, venous thromboembolism, fatigue, and visual complaints.
Computer vision syndrome (CVS) is one of the most frequently encountered problems among VDT users. CVS comprises several visual and musculoskeletal symptoms resulting from VDT use, such as eye strain, dryness and burning sensation of the eye, blurred vision, and neck and shoulder pain. A major alteration is the development of dry eye disease (DED), occurring in 60 % of those with CVS. Dry eye symptoms, corneal erosions, short tear-film breakup time (BUT), low tear meniscus height, and meibomian gland dysfunction (MGD) are all DED presentations encountered by VDT users. The continuous use of VDTs is an established risk factor for CVS and DED. However, it is unclear whether transient exposure to VDTs leads to ocular surface changes, especially regarding lipid layer thickness (LLT).
This study investigated if the short-term use of light-emitting diode (LED) displays (one type of VDT) changed the ocular parameters, including best-corrected visual acuity (BCVA), intraocular ocular pressure (IOP), the CVS-Questionnaire (CVS-Q) score, the blink rate, the partial blink ratio, and LLT. To our knowledge, this is the first study to focus on the immediate effects of LEDs on the eye.
This prospective clinical study was conducted in the Ophthalmology Department of the National Cheng Kung University Hospital (NCKUH), Tainan, Taiwan. The study was approved by the Institutional Review Board of NCKUH and followed the tenets of the Declaration of Helsinki. Written informed consent was obtained from all the participants.
The inclusion criteria were generally healthy individuals aged between 20 and 65 years who were willing to participate in the study. The exclusion criteria were ages below 20 or over 65 years, a BCVA score of <0.1 on the Landolt C chart in either eye, a BCVA difference of >0.2 between the eyes, and a history of ocular diseases or previous ocular surgery.
Participants were instructed to fill out a basic information form, including their name, sex, age, and contact information. They were also informed to avoid wearing contact lenses for two days before the test. The experiment was conducted on August 22, 2020. For the baseline test, the participants were asked to complete the CVS-Q to assess their CVS. Next was a series of ocular examinations, including BCVA, IOP, LLT, an optical coherence tomography (OCT) scan of the macula, and fundus autofluorescence (FAF) imaging. The LLT and blink rates were measured using the LipiView II Ocular Surface Interferometer following the standard protocol (TearScience, Morrisville, NC, USA). After the examination, the participants watched a short movie on an LED screen (InnoLux, Taiwan) for 15 minutes in a bright room. The viewing distance was approximately 1.5 meters. After the movie ended, the participants were instructed to complete the CVS-Q and undergo the BCVA, IOP, and LLT tests again. The baseline BCVA, IOP, OCT, and FAF images of each participant were reviewed by three NCKUH ophthalmologists to screen for clinically significant ocular pathology.
Statistical analyses were performed using R software version 4.1.0 (R Core Team, Vienna, Austria) and SAS Enterprise Guide (version 9.4; SAS Institute Inc., Cary, NC, USA). Paired t-tests were used to compare the BCVA, IOP, CVS-Q score, LLT, blink rate, and the partial blink ratio before and after watching the LED display. Statistical significance was set at P <0.05.
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| LED screen | Experimental | Device: LED screen (InnoLux, Taiwan) |
Who may qualify
- Ages
- 20 to 65 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (1 listed)
- generally healthy individuals aged between 20 and 65 years who were willing to participate in the study
Key exclusion criteria (4 listed)
- ages below 20 or over 65 years
- a BCVA score of <0.1 on the Landolt C chart in either eye
- a BCVA difference of >0.2 between the eyes
- a history of ocular diseases or previous ocular surgery
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| LED screen (InnoLux, Taiwan)Participants watch a short movie on an LED screen (InnoLux, Taiwan) for 15 minutes in a bright room. The viewing distance was approximately 1.5 meters. | Device | LED screen |
Primary outcome
Lipid Layer Thickness
Time frame: Change from baseline lipid layer thickness at 15 minutes
4 secondary outcomes
Visual Acuity
Time frame: Change from baseline visual acuity at 15 minutes
Intraocular Pressure
Time frame: Change from baseline intraocular pressure at 15 minutes
Blink rates
Time frame: Change from baseline blink rates at 15 minutes
Computer Vision Syndrome Questionnaire Score
Time frame: Change from Baseline Computer Vision Syndrome Questionnaire Score at 15 minutes
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 12 Aug 2021.
- Individual participant dataSharing planned: No. The informed consent of this study specified that the participants' data would only be used in this study
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Yi-Hsun Huang, PhD study chair
National Cheng-Kung University Hospital
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing LED screen (InnoLux, Taiwan) in people with Lipid Tear Deficiency (Disorder) and Dry Eye Disease, run by National Cheng-Kung University Hospital at 1 site in Taiwan.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 12 Aug 2021. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Taiwan. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Lipid Layer Thickness (time frame: Change from baseline lipid layer thickness at 15 minutes). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 Aug 2021.