AzTrials
AzTrials

Segmentation; BoneNCT05055986

Accuracy of Open-source Software in Semi-automatic 3-Dimensional Reconstruction of the Mandible

An observational study of Segmentation; Bone, run by Cairo University at 1 site in Egypt.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Concomitant to the evolution of CBCT devices, several post-processing software packages were developed for producing 3D-printed models of anatomical structures. In the last few years, several open-source software used as an alternative to commercial software for 3D reconstruction of anatomical structures such as the… Read more about this study

Who is it for?
Any ageHealthy volunteers can take part
Conditions the study is for
Segmentation; Bone
What is being tested?
Semiautomatic segmentation of open-source software
Type of treatment
Medical device
How many people
12 participants
Where
1 siteEgypt
Study dates
11 Nov 2021to Jan 2023
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult, Older adult

Study population: Patients who come to the Oral and Maxillofacial Department, Faculty of Dentistry, Cairo University for CBCT imaging for orthodontic treatment. Patients will be with intact mandible and free of any injury or disease that can affect the volume of the mandible.

Who may be able to join

  • Good quality CBCT scans.
  • Field of view (FOV) including the whole mandibular bone.
  • Absence of artifacts, dental implants, craniofacial deformities, and temporomandibular disorders.

Who cannot join

  • Low-quality CBCT scans.
  • FOV not including the whole mandibular bone.
  • Presence of artifacts, dental implants, craniofacial deformities, and temporomandibular disorders.

Trial locations and contacts

1 site in 1 country.

Maha S Mohamed, Master contact

01285478360

maha_sayed@dentistry.cu.edu.eg

Egypt1 site, 1 recruiting
  • Faculty of dentistry cairo university

    Cairo, 11555

    Maha Sa Mohamed, Master, 01285478360, maha_sayed@dentistry.cu.edu.eg

    Recruiting

Other trials in Egypt

About this study

Official title: Accuracy of Open-source Software in Semi-automatic 3-Dimensional Reconstruction of the Mandible: A Validity and Reliability Study

Concomitant to the evolution of CBCT devices, several post-processing software packages were developed for producing 3D-printed models of anatomical structures. In the last few years, several open-source software used as an alternative to commercial software for 3D reconstruction of anatomical structures such as the mandible. However, no sufficient evidence validating the accuracy of this open-source software.

Read the detailed description

3D rendering of craniomaxillofacial structures is based on the segmentation process. Semi-automatic segmentation has been pointed out as the technique of choice since it combines the high efficiency and repeatability of the automatic methods with the experience of an operator. Although the creation of 3D models is very important, it is still not a common procedure, since commercial software often requires higher electronic computer power and is licensed by its manufacturer, increasing the financial costs. In the last few years, several open-source software can be obtained for free such as ITK-Snap and 3D Slicer, which could provide more economical options for clinicians or researchers in patient management. However, no sufficient evidence validating the accuracy of this open-source software in detecting the volumetric and morphological characteristics of craniomaxillofacial structures.

Being tested
Semiautomatic segmentation of open-source software
Keywords
Open source software, Segmentation, Mandible

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Semiautomatic segmentation of open-source softwareDevice

    Also called ITK-Snap software, 3D Slicer software

    Semiautomatic segmentation of open-source software is accurate as of the manual segmentation of commercial software.

Study groups in NCT05055986
Study groupRoleWhat they receive
CBCT Dicom files of patientsCBCT Dicom files of patients will be used for measurements of mandibular bone volume by open-source software.
Receives: Device: Semiautomatic segmentation of open-source software

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Validity and reliability of CBCT open-source software (ITK-Snap and 3D Slicer) semiautomatic segmentation in Volumetric measurement of mandibular bone.

    The volume calculation function tool of the dedicated CBCT open-source software (ITK-Snap and 3D Slicer) will be used to measure the mandibular bone volume.

    Measured: 1 year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted24 Sep 2021
  2. Study start11 Nov 2021
  3. Primary completionNov 2022 (estimated)
  4. Study completionJan 2023 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Other
Time perspective
Prospective
Enrolment
12 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05055986
Sponsor's protocol ID
Open-source Software
Status last verified
Mar 2022
First submitted
11 Sep 2021
Last updated
9 Mar 2022
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes

Publications

  • Gomes AF, Brasil DM, Silva AIV, Freitas DQ, Haiter-Neto F, Groppo FC. Accuracy of ITK-SNAP software for 3D analysis of a non-regular topography structure. Oral Radiol. 2020 Apr;36(2):183-189. doi: 10.1007/s11282-019-00397-y. Epub 2019 Jul 2.

    PubMed 31267257
  • Matsiushevich K, Belvedere C, Leardini A, Durante S. Quantitative comparison of freeware software for bone mesh from DICOM files. J Biomech. 2019 Feb 14;84:247-251. doi: 10.1016/j.jbiomech.2018.12.031. Epub 2018 Dec 21.

    PubMed 30591203
  • Lo Giudice A, Ronsivalle V, Grippaudo C, Lucchese A, Muraglie S, Lagravere MO, Isola G. One Step before 3D Printing-Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandible: A Comparative Study Using a Surface-to-Surface Matching Technique. Materials (Basel). 2020 Jun 21;13(12):2798. doi: 10.3390/ma13122798.

    PubMed 32575875
  • Vallaeys K, Kacem A, Legoux H, Le Tenier M, Hamitouche C, Arbab-Chirani R. 3D dento-maxillary osteolytic lesion and active contour segmentation pilot study in CBCT: semi-automatic vs manual methods. Dentomaxillofac Radiol. 2015;44(8):20150079. doi: 10.1259/dmfr.20150079. Epub 2015 May 21.

    PubMed 25996572

Questions about this trial

What is this clinical trial studying?

An observational study of Segmentation; Bone, run by Cairo University at 1 site in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 9 Mar 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Maha S Mohamed, Master (01285478360, maha_sayed@dentistry.cu.edu.eg), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Validity and reliability of CBCT open-source software (ITK-Snap and 3D Slicer) semiautomatic segmentation in Volumetric measurement of mandibular bone. (time frame: 1 year). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05055986, which also lists 4 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Mar 2022.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in