Aortic Valve DiseaseNCT05093764
Quantification of Debris Captured Using TCEP During VIV TAVR With BVF
A study testing VIV TAVR with BVF using TCEP in people with Aortic Valve Disease, run by Saint Luke's Health System at 1 site in United States.
Trial summary
The objective of this study is to quantify the amount of debris captured by the SENTINEL transcatheter cerebral embolic protection (TCEP) device in patients undergoing valve in valve transcatheter aortic valve replacement (VIV TAVR) with bioprosthetic valvular fracture (BVF) Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Aortic Valve Disease
- What is being tested?
- VIV TAVR with BVF using TCEP
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 20 participants
- Where
- 1 siteUnited States
- Study dates
- 2 Mar 2022to 31 Dec 2025
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Men and Women ≥ 18 years of age
- The patient has severe bioprosthetic aortic valve degeneration (stenosis, insufficiency, or mixed valve disease) and a clinical indication for VIV TAVR
- The bioprosthetic valve can be fractured with high pressure balloon inflation.
- The patient is deemed at prohibitive or high mortality risk related to surgical aortic valve replacement as assessed by the Heart Team
- For procedural planning, all patients must have a CT angiogram of the chest, abdomen and pelvis to confirm:
- Adequate femoral access for the TAVR procedure B. Appropriate right subclavian, carotid and brachiocephalic as well as left carotid artery anatomy for the SENTINEL device deployment.
Show all 9Show fewer
- The patient or legal representative is able to understand and willing to provide written informed consent to participate in the trial
- The patient is able and willing to return for required follow-up visits and examinations
- The patient is evaluated by the multidisciplinary heart-valve team and found to be a suitable for the procedure.
Who cannot join
- Patients with low or moderate mortality risk from surgical aortic valve replacement
- Patients with bioprosthetic valves that cannot be fractured with standard non-compliant valvuloplasty balloons (Table 1)
- Patients with evidence of significant carotid artery stenosis (i.e., carotid stenosis ≥ 50%), noted on ultrasound duplex imaging or CT angiography.
- Patients with evidence of right subclavian/brachiocephalic artery stenosis
- Patients with right arm/forearm dialysis fistula or graft.
- Patients with harvested right radial artery for a previous coronary bypass surgery.
Show all 13Show fewer
- Patients with prohibitive aortic arch anomalies for SENTINEL device implantation.
- The patient with history of cerebrovascular event (CVA) within within 6 months.
- Patient with incidental left atrial appendage thrombus noted on TEE or CT imaging.
- The patient is actively enrolled in another trial of a cardiovascular device or an investigational drug (post-market study participation and registries are acceptable)
- The patient is pregnant, or pregnancy is planned during the course of the investigation if patient is of child-bearing potential
- Any clinically significant medical condition or presence of any laboratory abnormality performed prior to randomization that is considered by the investigator to be clinically important and could interfere with the conduct of the study or not meeting procedure guidelines for TAVR or SENTINEL
- The patient has a life expectancy of less than one year
Trial locations and contacts
1 site in 1 country.
United States1 site, 1 recruiting
- Recruiting
Saint Luke's Hospital of Kansas City
Kansas City, Missouri, 64111
Sheila Erwin, RN, 816-932-7996, serwin@saintlukeskc.org
Adnan Chhatriwalla, MD
About this study
Official title: Quantification of Debris Captured Using Transcatheter Cerebral Embolic Protection (TCEP) During Valve in Valve Transcatheter Aortic Valve Replacement (VIV TAVR) With Bioprosthetic Valvular Fracture (BVF)
The objective of this study is to quantify the amount of debris captured by the SENTINEL transcatheter cerebral embolic protection (TCEP) device in patients undergoing valve in valve transcatheter aortic valve replacement (VIV TAVR) with bioprosthetic valvular fracture (BVF)
Read the detailed description
SENTINEL VIV-TAVR is a prospective, single-center, single-arm, unblinded pilot trial. A total of 20 subjects with severe symptomatic bioprosthetic aortic valve degeneration, who are deemed to be at high or prohibitive mortality risk related to surgical aortic valve replacement, and are undergoing VIV-TAVR and BVF, will be enrolled at the Mid-America Heart Institute, St-Luke's Hospital of Kansas City. Subjects will initially have an aortic arch angiogram done to confirm appropriate anatomy, followed by the SENTINEL device implanted through right radial artery approach. After that, patients will undergo VIV TAVR, using a commercially available transcatheter heart valve, followed by bioprosthetic valve fracture (BVF) as indicated.
- Conditions
- Aortic Valve Disease
- Being tested
- VIV TAVR with BVF using TCEP
- Medical subject headings
- Aortic Valve Disease
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
VIV TAVR with BVF using TCEPDevice
The insertion and retrieval of the SENTINEL device is performed at the time of the patients TAVR procedure in the same setting while they are sedated under moderate sedation or general anesthesia depending on the case. The device is inserted at the initiation of the procedure through 6F right radial artery access and the filters are positioned in the left common carotid artery and brachiocephalic artery. After deployment, the usual TAVR procedure is performed. At the conclusion of the procedure, the SENTINEL device is extracted and hemostasis is achieved at the radial access site in the usual fashion with patent hemostasis.
| Study group | Role | What they receive |
|---|---|---|
| VIV TAVR with BVF using TCEP | Other | All subjects will receive the intervention. Receives: Device: VIV TAVR with BVF using TCEP |
What is being measured
The primary outcome is the main question the study is designed to answer.
Quantity of debris
Amount of debris captured by the SENTINEL TCEP device in VIV TAVR with BVF patients compared to historical data
Measured: During surgical procedure
Complication rate
In-hospital stroke, device embolization rate, procedure-related major bleeding
Measured: Through hospital discharge, an average of 2.5 days
Secondary outcomes (2)
Mortality
Deaths from all causes
Measured: Through hospital discharge, an average of 2.5 days
MACCE
Major adverse cardiac and cerebrovascular events
Measured: Through hospital discharge, an average of 2.5 days
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted26 Oct 2021
- Study start2 Mar 2022
- Primary completion31 Dec 2024 (estimated)
- Study completion31 Dec 2025 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (11)Papers the sponsor has linked to this study.
- Other trials for Aortic Valve DiseaseStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 20 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Saint Luke's Health System
- Sponsor type
- University, hospital or other
- Collaborators
- Boston Scientific Corporation
- Responsible party
- Sponsor
- Investigators
- Adnan Chhatriwalla, MD, Principal investigator, Saint Luke's Health System
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05093764
- Sponsor's protocol ID
- 21-109
- Status last verified
- Jun 2024
- First submitted
- 28 Sep 2021
- Last updated
- 14 Jun 2024
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Publications
Adams DH, Popma JJ, Reardon MJ, Yakubov SJ, Coselli JS, Deeb GM, Gleason TG, Buchbinder M, Hermiller J Jr, Kleiman NS, Chetcuti S, Heiser J, Merhi W, Zorn G, Tadros P, Robinson N, Petrossian G, Hughes GC, Harrison JK, Conte J, Maini B, Mumtaz M, Chenoweth S, Oh JK; U.S. CoreValve Clinical Investigators. Transcatheter aortic-valve replacement with a self-expanding prosthesis. N Engl J Med. 2014 May 8;370(19):1790-8. doi: 10.1056/NEJMoa1400590. Epub 2014 Mar 29.
PubMed 24678937Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, Brown DL, Block PC, Guyton RA, Pichard AD, Bavaria JE, Herrmann HC, Douglas PS, Petersen JL, Akin JJ, Anderson WN, Wang D, Pocock S; PARTNER Trial Investigators. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. 2010 Oct 21;363(17):1597-607. doi: 10.1056/NEJMoa1008232. Epub 2010 Sep 22.
PubMed 20961243Leon MB, Smith CR, Mack MJ, Makkar RR, Svensson LG, Kodali SK, Thourani VH, Tuzcu EM, Miller DC, Herrmann HC, Doshi D, Cohen DJ, Pichard AD, Kapadia S, Dewey T, Babaliaros V, Szeto WY, Williams MR, Kereiakes D, Zajarias A, Greason KL, Whisenant BK, Hodson RW, Moses JW, Trento A, Brown DL, Fearon WF, Pibarot P, Hahn RT, Jaber WA, Anderson WN, Alu MC, Webb JG; PARTNER 2 Investigators. Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients. N Engl J Med. 2016 Apr 28;374(17):1609-20. doi: 10.1056/NEJMoa1514616. Epub 2016 Apr 2.
PubMed 27040324Smith CR, Leon MB, Mack MJ, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, Williams M, Dewey T, Kapadia S, Babaliaros V, Thourani VH, Corso P, Pichard AD, Bavaria JE, Herrmann HC, Akin JJ, Anderson WN, Wang D, Pocock SJ; PARTNER Trial Investigators. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med. 2011 Jun 9;364(23):2187-98. doi: 10.1056/NEJMoa1103510. Epub 2011 Jun 5.
PubMed 21639811Fairbairn TA, Mather AN, Bijsterveld P, Worthy G, Currie S, Goddard AJ, Blackman DJ, Plein S, Greenwood JP. Diffusion-weighted MRI determined cerebral embolic infarction following transcatheter aortic valve implantation: assessment of predictive risk factors and the relationship to subsequent health status. Heart. 2012 Jan;98(1):18-23. doi: 10.1136/heartjnl-2011-300065. Epub 2011 Jul 7.
PubMed 21737581Ghanem A, Muller A, Nahle CP, Kocurek J, Werner N, Hammerstingl C, Schild HH, Schwab JO, Mellert F, Fimmers R, Nickenig G, Thomas D. Risk and fate of cerebral embolism after transfemoral aortic valve implantation: a prospective pilot study with diffusion-weighted magnetic resonance imaging. J Am Coll Cardiol. 2010 Apr 6;55(14):1427-32. doi: 10.1016/j.jacc.2009.12.026. Epub 2010 Feb 24.
PubMed 20188503Kahlert P, Knipp SC, Schlamann M, Thielmann M, Al-Rashid F, Weber M, Johansson U, Wendt D, Jakob HG, Forsting M, Sack S, Erbel R, Eggebrecht H. Silent and apparent cerebral ischemia after percutaneous transfemoral aortic valve implantation: a diffusion-weighted magnetic resonance imaging study. Circulation. 2010 Feb 23;121(7):870-8. doi: 10.1161/CIRCULATIONAHA.109.855866.
PubMed 20177005Spaziano M, Francese DP, Leon MB, Genereux P. Imaging and functional testing to assess clinical and subclinical neurological events after transcatheter or surgical aortic valve replacement: a comprehensive review. J Am Coll Cardiol. 2014 Nov 4;64(18):1950-63. doi: 10.1016/j.jacc.2014.07.986. Epub 2014 Oct 27.
PubMed 25444149Kapadia SR, Kodali S, Makkar R, Mehran R, Lazar RM, Zivadinov R, Dwyer MG, Jilaihawi H, Virmani R, Anwaruddin S, Thourani VH, Nazif T, Mangner N, Woitek F, Krishnaswamy A, Mick S, Chakravarty T, Nakamura M, McCabe JM, Satler L, Zajarias A, Szeto WY, Svensson L, Alu MC, White RM, Kraemer C, Parhizgar A, Leon MB, Linke A; SENTINEL Trial Investigators. Protection Against Cerebral Embolism During Transcatheter Aortic Valve Replacement. J Am Coll Cardiol. 2017 Jan 31;69(4):367-377. doi: 10.1016/j.jacc.2016.10.023. Epub 2016 Nov 1.
PubMed 27815101Allen KB, Chhatriwalla AK, Cohen DJ, Saxon JT, Aggarwal S, Hart A, Baron S, Davis JR, Pak AF, Dvir D, Borkon AM. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation. Ann Thorac Surg. 2017 Nov;104(5):1501-1508. doi: 10.1016/j.athoracsur.2017.04.007. Epub 2017 Jun 29.
PubMed 28669505Chhatriwalla AK, Allen KB, Saxon JT, Cohen DJ, Aggarwal S, Hart AJ, Baron SJ, Dvir D, Borkon AM. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement. Circ Cardiovasc Interv. 2017 Jul;10(7):e005216. doi: 10.1161/CIRCINTERVENTIONS.117.005216.
PubMed 28698291
Study at a glance
From the registry record, last updated by the sponsor on 14 Jun 2024. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Quantification of Debris Captured Using Transcatheter Cerebral Embolic Protection (TCEP) During Valve in Valve Transcatheter Aortic Valve Replacement (VIV TAVR) With Bioprosthetic Valvular Fracture (BVF)
- ClinicalTrials.gov ID
- NCT05093764
- Acronym / sponsor ID
- 21-109
- Conditions
- Aortic Valve Disease
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 20 participants (estimated)
- Lead sponsor
- Saint Luke's Health SystemUniversity, hospital or other
- Collaborators
- Boston Scientific Corporation
- Study start
- 2 Mar 2022 (actual)
- Primary completion
- 31 Dec 2024 (estimated)
- Study completion
- 31 Dec 2025 (estimated)
- First posted
- 26 Oct 2021 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The objective of this study is to quantify the amount of debris captured by the SENTINEL transcatheter cerebral embolic protection (TCEP) device in patients undergoing valve in valve transcatheter aortic valve replacement (VIV TAVR) with bioprosthetic valvular fracture (BVF)
Detailed description
SENTINEL VIV-TAVR is a prospective, single-center, single-arm, unblinded pilot trial. A total of 20 subjects with severe symptomatic bioprosthetic aortic valve degeneration, who are deemed to be at high or prohibitive mortality risk related to surgical aortic valve replacement, and are undergoing VIV-TAVR and BVF, will be enrolled at the Mid-America Heart Institute, St-Luke's Hospital of Kansas City. Subjects will initially have an aortic arch angiogram done to confirm appropriate anatomy, followed by the SENTINEL device implanted through right radial artery approach. After that, patients will undergo VIV TAVR, using a commercially available transcatheter heart valve, followed by bioprosthetic valve fracture (BVF) as indicated.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| VIV TAVR with BVF using TCEP | Other | Device: VIV TAVR with BVF using TCEPAll subjects will receive the intervention. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (9 listed)
- Men and Women ≥ 18 years of age
- The patient has severe bioprosthetic aortic valve degeneration (stenosis, insufficiency, or mixed valve disease) and a clinical indication for VIV TAVR
- The bioprosthetic valve can be fractured with high pressure balloon inflation.
- The patient is deemed at prohibitive or high mortality risk related to surgical aortic valve replacement as assessed by the Heart Team
- For procedural planning, all patients must have a CT angiogram of the chest, abdomen and pelvis to confirm:
Key exclusion criteria (13 listed)
- Patients with low or moderate mortality risk from surgical aortic valve replacement
- Patients with bioprosthetic valves that cannot be fractured with standard non-compliant valvuloplasty balloons (Table 1)
- Patients with evidence of significant carotid artery stenosis (i.e., carotid stenosis ≥ 50%), noted on ultrasound duplex imaging or CT angiography.
- Patients with evidence of right subclavian/brachiocephalic artery stenosis
- Patients with right arm/forearm dialysis fistula or graft.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| VIV TAVR with BVF using TCEPThe insertion and retrieval of the SENTINEL device is performed at the time of the patients TAVR procedure in the same setting while they are sedated under moderate sedation or general anesthesia depending on the case. The device is inserted at the initiation of the procedure through 6F right radial artery access and the filters are positioned in the left common carotid artery and brachiocephalic artery. After deployment, the usual TAVR procedure is performed. At the conclusion of the procedure, the SENTINEL device is extracted and hemostasis is achieved at the radial access site in the usual fashion with patent hemostasis. | Device | VIV TAVR with BVF using TCEP |
Primary outcome
Quantity of debris
Time frame: During surgical procedure
Amount of debris captured by the SENTINEL TCEP device in VIV TAVR with BVF patients compared to historical data
Complication rate
Time frame: Through hospital discharge, an average of 2.5 days
In-hospital stroke, device embolization rate, procedure-related major bleeding
2 secondary outcomes
Mortality
Time frame: Through hospital discharge, an average of 2.5 days
MACCE
Time frame: Through hospital discharge, an average of 2.5 days
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 14 Jun 2024.
- Results publication: PubMed 24678937Adams DH, Popma JJ, Reardon MJ, Yakubov SJ, Coselli JS, Deeb GM, Gleason TG, Buchbinder M, Hermiller J Jr, Kleiman NS, Chetcuti S, Heiser J, Merhi W, Zorn G, Tadros P, Robinson N, Petrossian G, Hughes GC, Harrison JK, Conte J, Maini B, Mumtaz M, Chenoweth S, Oh JK; U.S. CoreValve Clinical Investigators. Transcatheter aortic-valve replacement with a self-expanding prosthesis. N Engl J Med. 2014 May 8;370(19):1790-8. doi: 10.1056/NEJMoa1400590. Epub 2014 Mar 29.
- Results publication: PubMed 20961243Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, Brown DL, Block PC, Guyton RA, Pichard AD, Bavaria JE, Herrmann HC, Douglas PS, Petersen JL, Akin JJ, Anderson WN, Wang D, Pocock S; PARTNER Trial Investigators. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. 2010 Oct 21;363(17):1597-607. doi: 10.1056/NEJMoa1008232. Epub 2010 Sep 22.
- Results publication: PubMed 27040324Leon MB, Smith CR, Mack MJ, Makkar RR, Svensson LG, Kodali SK, Thourani VH, Tuzcu EM, Miller DC, Herrmann HC, Doshi D, Cohen DJ, Pichard AD, Kapadia S, Dewey T, Babaliaros V, Szeto WY, Williams MR, Kereiakes D, Zajarias A, Greason KL, Whisenant BK, Hodson RW, Moses JW, Trento A, Brown DL, Fearon WF, Pibarot P, Hahn RT, Jaber WA, Anderson WN, Alu MC, Webb JG; PARTNER 2 Investigators. Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients. N Engl J Med. 2016 Apr 28;374(17):1609-20. doi: 10.1056/NEJMoa1514616. Epub 2016 Apr 2.
- Results publication: PubMed 21639811Smith CR, Leon MB, Mack MJ, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, Williams M, Dewey T, Kapadia S, Babaliaros V, Thourani VH, Corso P, Pichard AD, Bavaria JE, Herrmann HC, Akin JJ, Anderson WN, Wang D, Pocock SJ; PARTNER Trial Investigators. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med. 2011 Jun 9;364(23):2187-98. doi: 10.1056/NEJMoa1103510. Epub 2011 Jun 5.
- Results publication: PubMed 21737581Fairbairn TA, Mather AN, Bijsterveld P, Worthy G, Currie S, Goddard AJ, Blackman DJ, Plein S, Greenwood JP. Diffusion-weighted MRI determined cerebral embolic infarction following transcatheter aortic valve implantation: assessment of predictive risk factors and the relationship to subsequent health status. Heart. 2012 Jan;98(1):18-23. doi: 10.1136/heartjnl-2011-300065. Epub 2011 Jul 7.
- Results publication: PubMed 20188503Ghanem A, Muller A, Nahle CP, Kocurek J, Werner N, Hammerstingl C, Schild HH, Schwab JO, Mellert F, Fimmers R, Nickenig G, Thomas D. Risk and fate of cerebral embolism after transfemoral aortic valve implantation: a prospective pilot study with diffusion-weighted magnetic resonance imaging. J Am Coll Cardiol. 2010 Apr 6;55(14):1427-32. doi: 10.1016/j.jacc.2009.12.026. Epub 2010 Feb 24.
- Results publication: PubMed 20177005Kahlert P, Knipp SC, Schlamann M, Thielmann M, Al-Rashid F, Weber M, Johansson U, Wendt D, Jakob HG, Forsting M, Sack S, Erbel R, Eggebrecht H. Silent and apparent cerebral ischemia after percutaneous transfemoral aortic valve implantation: a diffusion-weighted magnetic resonance imaging study. Circulation. 2010 Feb 23;121(7):870-8. doi: 10.1161/CIRCULATIONAHA.109.855866.
- Results publication: PubMed 25444149Spaziano M, Francese DP, Leon MB, Genereux P. Imaging and functional testing to assess clinical and subclinical neurological events after transcatheter or surgical aortic valve replacement: a comprehensive review. J Am Coll Cardiol. 2014 Nov 4;64(18):1950-63. doi: 10.1016/j.jacc.2014.07.986. Epub 2014 Oct 27.
- Results publication: PubMed 27815101Kapadia SR, Kodali S, Makkar R, Mehran R, Lazar RM, Zivadinov R, Dwyer MG, Jilaihawi H, Virmani R, Anwaruddin S, Thourani VH, Nazif T, Mangner N, Woitek F, Krishnaswamy A, Mick S, Chakravarty T, Nakamura M, McCabe JM, Satler L, Zajarias A, Szeto WY, Svensson L, Alu MC, White RM, Kraemer C, Parhizgar A, Leon MB, Linke A; SENTINEL Trial Investigators. Protection Against Cerebral Embolism During Transcatheter Aortic Valve Replacement. J Am Coll Cardiol. 2017 Jan 31;69(4):367-377. doi: 10.1016/j.jacc.2016.10.023. Epub 2016 Nov 1.
- Results publication: PubMed 28669505Allen KB, Chhatriwalla AK, Cohen DJ, Saxon JT, Aggarwal S, Hart A, Baron S, Davis JR, Pak AF, Dvir D, Borkon AM. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation. Ann Thorac Surg. 2017 Nov;104(5):1501-1508. doi: 10.1016/j.athoracsur.2017.04.007. Epub 2017 Jun 29.
- Results publication: PubMed 28698291Chhatriwalla AK, Allen KB, Saxon JT, Cohen DJ, Aggarwal S, Hart AJ, Baron SJ, Dvir D, Borkon AM. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement. Circ Cardiovasc Interv. 2017 Jul;10(7):e005216. doi: 10.1161/CIRCINTERVENTIONS.117.005216.
- Individual participant dataSharing planned: No
Related trials for Aortic Valve Disease
Recruiting
Systematic Ambulatory ECG Monitoring Following TAVI
Aortic Stenosis, Conduction Disturbances
RecruitingObservational study
Multicenter Study for the Validation of Willem AI: Aortic StenoSis Early Diagnosis With AI-electrocardiogram Study
Aortic Stenosis
Recruiting
Ambulatory Electrocardiographic Monitoring for the Detection of High-Degree Atrio-Ventricular Block in Patients With New-onset PeRsistent LEft Bundle Branch Block After Transcatheter Aortic Valve Implantation. The "MARE" Study
Aortic Valve Disease, Conduction Disturbances
RecruitingObservational study
Heart Failure and Aortic Stenosis Transcriptome
Heart Failure, Aortic Stenosis
Recruiting
Positron Emission Tomography to Assess the Effect of Camzyos on Ischaemia in HOCM: PEACH Trial
Hypertrophic Obstructive Cardiomyopathy \(HOCM\), Left Ventricular Outflow Tract Obstruction
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Adnan Chhatriwalla, MD principal investigator
Saint Luke's Health System
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing VIV TAVR with BVF using TCEP in people with Aortic Valve Disease, run by Saint Luke's Health System at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 9 inclusion and 13 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 14 Jun 2024. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Sheila Erwin, RN (816-932-7996, serwin@saintlukeskc.org), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Quantity of debris (time frame: During surgical procedure). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT05093764, which also lists 11 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Jun 2024.