Evaluation of Preterm NAVA Catheter PlacementPIPINCT05107713

Positioning of EDI Catheter In Premature Infants

An observational study of Evaluation of Preterm NAVA Catheter Placement, run by Unity Health Toronto at 1 site in Canada.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Nasogastric (NG) and orogastric (OG) feeding tubes have a high incidence of malpositioning, occurring in up to 59% of preterm infants (Lopes 2019). Ideally, the tip of the feeding tube (including the orifices) should be located within the body of the stomach. Read more about this study

Who is it for?
Ages 1 day to 1 year
How many people
65 participants
Where
1 siteCanada
Study dates
1 Nov 2021to 3 May 2023
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 1 day to 1 year
  • All sexes
  • Child

Study population: All babies, irrespective of GA, whose current weight is 400-2000g, who are: * about to be equipped OR already equipped with a 6F or 8F (49 or 50 cm) Edi feeding tube for clinical or research purposes. * Babies who are prescribed clinically or for research purposes, to have a chest/abdominal radiograph. Babies may be breathing on NAVA, NIV-NAVA or neural monitoring during a conventional mode or HFO, or nCPAP/HFNC. * Placement of a second feeding tube is permitted, as well as oral or nasal feeding tube insertion

Who may be able to join

None listed.

Who cannot join

  • Patient exclusion criteria:
  • Previous gastric surgery, anatomical abnormalities. Further reasons for exclusion will be left to the clinicians at each site.
  • -

Trial locations and contacts

1 site in 1 country.

Canada1 site
  • Unity Health

    Toronto, Ontario, M5B 1W8

Other trials in Canada

About this study

Nasogastric (NG) and orogastric (OG) feeding tubes have a high incidence of malpositioning, occurring in up to 59% of preterm infants (Lopes 2019). Ideally, the tip of the feeding tube (including the orifices) should be located within the body of the stomach.

Malpositioning of the feeding tube can be classified as (i) being "too far out" where the tip of the catheter is located in the esophagus above the gastro-esophageal junction, potentially resulting in reflux, aspiration, apnea or (ii) being inserted "too far in" where the tip is located in the pylorus or the duodenum, leading to malabsorption of nutrients, diarrhea, and poor weight gain. Feeding tubes can also be found "curled up" inside the stomach (Quandt 2009) as much as 35% of the time. As well, one cannot ignore the risk of perforation, where the incidence has been reported to be 1.1% in extremely low birth weight (ELBW) infants (<1000g) (n = 7/646) (Thanhaeuser M, 2019); of note: perforations occurred on the third day of life (range days 2-14) not during initial feeding tube placement.

Read more

In 2008, a modified feeding tube was introduced to the market (Maquet Critical Care AB), which contains sensors placed in its wall, 13 mm above the feeding orifices, used for measuring the electrical activity of the diaphragm (Edi) during spontaneous breathing. The Edi signal is then used to neurally control mechanical ventilation, or for neural monitoring of the breathing pattern (Sinderby 1999; Beck 2016). The so-called "Edi catheter" comes with the manufacturer's recommended insertion measurements and verification window. In the Servo-I, the insertion distance is provided by a formula on the catheter packaging. In the Servo-U and Servo-n, the calculation for predicted insertion is provided by a tool in the ventilator. There is no available, published data upon which the manufacturer's recommendations were based. It is possible that obtaining appropriate positioning of the Edi catheter - based on a pattern of electrical signals from the sensors - could reduce the incidence of malposition.

This proposed study is observational, and non-interventional. The purpose is to verify the position of a neurally guided, clinically-placed, Edi catheter using radiography (Ellett 2011). We will also record physical measurements and weights of the babies in order to validate previously described methods of predicting insertion length. The x-rays will be taken with "near-simultaneous" screenshots of the Edi catheter positioning window.

Read the detailed description

Nasogastric (NG) and orogastric (OG) feeding tubes have a high incidence of malpositioning, occurring in up to 59% of preterm infants (Lopes 2019). Ideally, the tip of the feeding tube (including the orifices) should be located within the body of the stomach.

Malpositioning of the feeding tube can be classified as (i) being "too far out" where the tip of the catheter is located in the esophagus above the gastro-esophageal junction, potentially resulting in reflux, aspiration, apnea or (ii) being inserted "too far in" where the tip is located in the pylorus or the duodenum, leading to malabsorption of nutrients, diarrhea, and poor weight gain. Feeding tubes can also be found "curled up" inside the stomach (Quandt 2009) as much as 35% of the time. As well, one cannot ignore the risk of perforation, where the incidence has been reported to be 1.1% in extremely low birth weight (ELBW) infants (<1000g) (n = 7/646) (Thanhaeuser M, 2019); of note: perforations occurred on the third day of life (range days 2-14) not during initial feeding tube placement.

In 2008, a modified feeding tube was introduced to the market (Maquet Critical Care AB), which contains sensors placed in its wall, 13 mm above the feeding orifices, used for measuring the electrical activity of the diaphragm (Edi) during spontaneous breathing. The Edi signal is then used to neurally control mechanical ventilation, or for neural monitoring of the breathing pattern (Sinderby 1999; Beck 2016). The so-called "Edi catheter" comes with the manufacturer's recommended insertion measurements and verification window. In the Servo-I, the insertion distance is provided by a formula on the catheter packaging. In the Servo-U and Servo-n, the calculation for predicted insertion is provided by a tool in the ventilator. There is no available, published data upon which the manufacturer's recommendations were based. It is possible that obtaining appropriate positioning of the Edi catheter - based on a pattern of electrical signals from the sensors - could reduce the incidence of malposition.

This proposed study is observational, and non-interventional. The purpose is to verify the position of a neurally guided, clinically-placed, Edi catheter using radiography (Ellett 2011). The investigators will also record physical measurements and weights of the babies in order to validate previously described methods of predicting insertion length. The x-rays will be taken with "near-simultaneous" screenshots of the Edi catheter positioning window.

The investigators plan on studying a convenience sample of 65 premature babies of varying weights, from 9 sites.

Objective of the study:

To determine if optimal positioning of the Edi catheter results in feeding holes in the stomach in neonates. The aim is to capture a screenshot of the Edi catheter positioning along with one radiograph.

Study design:

This is a multi-centre, observational study.

Procedures:

  1. Once the subject is enrolled, if not already inserted, the Edi catheter will be placed as guided by routine clinical practice and fixed in place.
  2. Data collection form will be completed.
  3. When the placement of the Edi catheter is deemed satisfactory (or may have already been in place), a screenshot or photograph of the catheter positioning window is taken. Clinicians should make an effort to capture a screenshot just prior to or immediately after the radiograph is done, taking effort to maintain the same patient positioning to prevent inadvertent migration of the Edi catheter.
  4. Radiograph taken.
  5. Send all info to J Beck: package would include de-identified data: Data collection form, screen shot, radiograph.
  6. De-identified data will be initially sent to a secure server at Neurovent Research Inc, for then transfer to St-Michael's Hospital (lead site).

Analysis:

Radiographs will be analyzed after-the-fact, by Dr. Kay North, without having information on the catheter positioning window. The location of the tip of the catheter will be classified into one of four categories: 1. Tube tip in esophagus. 2 Tube tip in the region of the GEJ. 3. Tube tip in the stomach. 4. Tube tip in the pylorus. Any other comments would be noted (e.g. curled up catheter, catheter tip impinging on the lateral gastric wall), (Quandt 2009).

Screenshot of positioning window. Two independent analysts from St-Michael's Hospital will determine diaphragm position on the array. With the 6 mm IED catheter we have a resolution of 12 mm.

The measurements on the data collection form about NEX, NEMU and ARHB will be correlated to catheter insertion distance.

Other data will be used for anthropometric information

Keywords
Neurally Adjusted Ventilatory Assist, NAVA catheter, Edi catheter, electrical activity of the diaphragm, feeding tube placement

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. position of NAVA catheter determined by xray

    Radiographs of clinically placed catheters will be evaluated by an independent radiologist

    Measured: 1 year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 Nov 2021
  2. Study start1 Nov 2021
  3. Primary completion3 May 2023
  4. Study completion3 May 2023

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Other
Time perspective
Prospective
Enrolment
65 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05107713
Sponsor's protocol ID
21-078
Acronym
PIPI
Status last verified
May 2023
First submitted
25 Oct 2021
Last updated
6 May 2023
Results posted
No
Data monitoring committee
No
Individual data sharing
Yes: Radiographs will be analyzed by an independent radiologist

Questions about this trial

What is this clinical trial studying?

An observational study of Evaluation of Preterm NAVA Catheter Placement, run by Unity Health Toronto at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 0 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 6 May 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

position of NAVA catheter determined by xray (time frame: 1 year). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 May 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in