AzTrials
AzTrials

Coronary Stent OcclusionNCT05131191

CT-FFR for Coronary In-stent Stenosis Based on ISR-Net Algorithm

An observational study of Coronary Stent Occlusion, run by Beijing Hospital at 1 site in China.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

CT-FFR(CT-derived flow reserve fraction) usually could not been measured accurately for in-stent lesions due to the serious interference with the metal structs. ISR-Net is a new algorithm in assessing the flow of coronary in-stent stenosis. Read more about this study

Who is it for?
Ages 18 to 90 years
Conditions the study is for
Coronary Stent Occlusion
What is being tested?
CT-FFR measurement and invasive FFR
How many people
150 participants
Where
1 siteChina
Study dates
1 Jan 2022to 1 Jun 2024
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 90 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Patients were implanted metal stents previously and had indications for coronary CTA test. The CT-FFR for in-stent lesions were evaluated based on Coronary CTA. Patients had the indication for invasive coronary angiography would be admitted in Cath lab and perform FFR measurement with pressure wire .

Who may be able to join

  • General Inclusion Criteria:
  • Over 18 years old;
  • Be able to understand the purpose of the test and sign the informed consent form;
  • Previous intracoronary stent implantation;
  • According to the comprehensive clinical evaluation, coronary angiography and FFR were proposed;
  • CTA image Inclusion Criteria:
  • The coronary CT angiography images showed that the reference vessel diameter of the stenosis segment in the stent was ≥ 2mm;
  • The stenosis degree of coronary stent diameter ≥ 30% and ≤ 90% by visual inspection.

Who cannot join

  • General exclusion criteria:
  • Previous coronary artery bypass grafting (CABG), artificial heart valve implantation, pacemaker or implantable defibrillator implantation;
  • There are persistent or active symptoms of clinical instability, including acute chest pain (sudden onset), cardiogenic shock, unstable blood pressure state (systolic blood pressure less than 90 mmHg), severe congestive heart failure (NYHA cardiac function grade III or IV) or acute pulmonary edema;
  • Acute myocardial infarction occurred within 7 days before enrollment;
  • Patients with other severe diseases are not suitable for clinical trials, such as complex congenital heart history, sick sinus syndrome, long QT syndrome, severe arrhythmia or tachycardia, severe asthma, severe or very severe chronic obstructive pulmonary disease, chronic renal function impairment (serum creatinine value > 1.5 mg / dL or creatinine clearance rate < 45ml / kg · 1.73m2);
  • There are contraindications to the use of disodium adenosine triphosphate;
Show all 13Show fewer
  • Allergic to iodized contrast media;
  • Pregnancy or unknown pregnancy status;
  • The expected life is less than 2 months;
  • There are any other factors that the researchers believe are not suitable for inclusion or completion of this study.
  • CTA image exclusion criteria:
  • The coronary artery image was obviously misplaced;
  • Coronary artery occlusion.

Trial locations and contacts

1 site in 1 country.

China1 site
  • Beijing Hospital

    Beijing

Other trials in China

About this study

Official title: Application of New Algorithm ISR-Net in Measuring CT-FFR of Coronary In-stent Stenosis.

CT-FFR(CT-derived flow reserve fraction) usually could not been measured accurately for in-stent lesions due to the serious interference with the metal structs. ISR-Net is a new algorithm in assessing the flow of coronary in-stent stenosis. We compare the CT-FFR value of in-stent lesions with the invasive FFR measured by pressure wire to evaluate the accuracy of ISR-Net algorithm. The research results are of great significance to solve the bottleneck problem of CT-FFR and expand its application scope.

Read the detailed description

CT-FFR is an important noninvasive examination to evaluate the function of coronary artery disease. It can help clinicians make clinical decisions and reduce patients' invasive coronary angiography (ICA). The image quality of coronary CT angiography (CCTA) is the basis of CT-FFR measurement. Because metal stents seriously interfere with the imaging of CCTA, it is very difficult to measure the CT-FFR value of lesions in stents. However, a large number of patients need imaging follow-up evaluation after stenting. In the previous research, the investigators creatively invented a new algorithm ISR-Net and conducted a retrospective analysis. It is preliminarily proved that the algorithm can more accurately display the stenosis lesions in the stent than the previous imaging software, making it possible to calculate the CT-FFR of the lesions in the stent. At present, the algorithm has applied for a national invention patent. In order to transform to clinical application, further clinical verification is needed. This study will evaluate the accuracy of ISR-Net algorithm in assessing the function of coronary stent stenosis by carrying out prospective clinical trials and taking the blood flow reserve fraction (FFR) measured by pressure wire as the gold standard. At the same time, the standard process of CT-FFR measurement of in stent lesions was established. The research results are of great significance to solve the bottleneck problem of CT-FFR and expand its application scope.

Being tested
CT-FFR measurement, invasive FFR
Keywords
in-stent stenosis, CT derived fractional flow reserve, artificial intelligence, deep learning, image processing

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • CT-FFR measurementDiagnostic test

    Also called FFRCT

    Patients were scanned with ≥ 64 row CT according to standard operating specifications. The software obtains the coronary CT angiography image file through the data communication interface. Based on the image processing algorithm, the centerline and contour of the target vessel can be extracted, and then the target vessel can be reconstructed to obtain the three-dimensional size information of the vessel; Based on hydrodynamics calculation and analysis, the fractional flow reserve (FFR) of each position of the target vessel is measured.

  • invasive FFRProcedure or surgery

    Also called pressure wire

    Insert the pressure guide wire into the finger guide tube and push the pressure guide wire until the pressure sensor just comes out of the orifice of guiding catheter; Equalize PD and PA values;Push the pressure guide wire to the distal end of the lesion, and record the measured blood vessel and position;Record the resting Pd / PA of the pressure guide wire;Nitroglycerin and adenosine triphosphate were administered intravenously according to standard catheter laboratory specifications to achieve maximum hyperemia;Record the FFR value of the in-stent lesions.

Study groups in NCT05131191
Study groupRoleWhat they receive
patients with coronary metal stents implantationNot described
Receives: Diagnostic Test: CT-FFR measurement; Procedure: invasive FFR

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. To predict the sensitivity, specificity and accuracy of CT-FFR in the functional sense of in stent lesions based on ISR-Net algorithm.

    Measured: one month

Secondary outcomes (1)
  1. To predict the functional accuracy of in stent lesions, PPV, NPV and area under ROC curve (AUC)

    Measured: one month

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted23 Nov 2021
  2. Study start1 Jan 2022
  3. Primary completion1 Jan 2024 (estimated)
  4. Study completion1 Jun 2024 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case-control
Time perspective
Prospective
Enrolment
150 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05131191
Sponsor's protocol ID
CT-FFR for in-stent lesion
Status last verified
Feb 2023
First submitted
11 Nov 2021
Last updated
8 Feb 2023
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Li Z, Zhang J, Xu L, Yang W, Li G, Ding D, Chang Y, Yu M, Kitslaar P, Zhang S, Reiber JHC, Arbab-Zadeh A, Yan F, Tu S. Diagnostic Accuracy of a Fast Computational Approach to Derive Fractional Flow Reserve From Coronary CT Angiography. JACC Cardiovasc Imaging. 2020 Jan;13(1 Pt 1):172-175. doi: 10.1016/j.jcmg.2019.08.003. Epub 2019 Sep 18. No abstract available.

    PubMed 31542542
  • Tang CX, Liu CY, Lu MJ, Schoepf UJ, Tesche C, Bayer RR 2nd, Hudson HT Jr, Zhang XL, Li JH, Wang YN, Zhou CS, Zhang JY, Yu MM, Hou Y, Zheng MW, Zhang B, Zhang DM, Yi Y, Ren Y, Li CW, Zhao X, Lu GM, Hu XH, Xu L, Zhang LJ. CT FFR for Ischemia-Specific CAD With a New Computational Fluid Dynamics Algorithm: A Chinese Multicenter Study. JACC Cardiovasc Imaging. 2020 Apr;13(4):980-990. doi: 10.1016/j.jcmg.2019.06.018. Epub 2019 Aug 14.

    PubMed 31422138
  • Coenen A, Kim YH, Kruk M, Tesche C, De Geer J, Kurata A, Lubbers ML, Daemen J, Itu L, Rapaka S, Sharma P, Schwemmer C, Persson A, Schoepf UJ, Kepka C, Hyun Yang D, Nieman K. Diagnostic Accuracy of a Machine-Learning Approach to Coronary Computed Tomographic Angiography-Based Fractional Flow Reserve: Result From the MACHINE Consortium. Circ Cardiovasc Imaging. 2018 Jun;11(6):e007217. doi: 10.1161/CIRCIMAGING.117.007217.

    PubMed 29914866
  • Ko BS, Cameron JD, Munnur RK, Wong DTL, Fujisawa Y, Sakaguchi T, Hirohata K, Hislop-Jambrich J, Fujimoto S, Takamura K, Crossett M, Leung M, Kuganesan A, Malaiapan Y, Nasis A, Troupis J, Meredith IT, Seneviratne SK. Noninvasive CT-Derived FFR Based on Structural and Fluid Analysis: A Comparison With Invasive FFR for Detection of Functionally Significant Stenosis. JACC Cardiovasc Imaging. 2017 Jun;10(6):663-673. doi: 10.1016/j.jcmg.2016.07.005. Epub 2016 Oct 19.

    PubMed 27771399
  • Coenen A, Lubbers MM, Kurata A, Kono A, Dedic A, Chelu RG, Dijkshoorn ML, van Geuns RJ, Schoebinger M, Itu L, Sharma P, Nieman K. Coronary CT angiography derived fractional flow reserve: Methodology and evaluation of a point of care algorithm. J Cardiovasc Comput Tomogr. 2016 Mar-Apr;10(2):105-13. doi: 10.1016/j.jcct.2015.12.006. Epub 2015 Dec 18.

    PubMed 26747231
  • Fuchs A, Kuhl JT, Chen MY, Helqvist S, Razeto M, Arakita K, Steveson C, Arai AE, Kofoed KF. Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography. J Cardiovasc Comput Tomogr. 2015 Sep-Oct;9(5):393-8. doi: 10.1016/j.jcct.2015.03.016. Epub 2015 Apr 16.

    PubMed 26091841

Questions about this trial

What is this clinical trial studying?

An observational study of Coronary Stent Occlusion, run by Beijing Hospital at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 8 inclusion and 13 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 8 Feb 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

To predict the sensitivity, specificity and accuracy of CT-FFR in the functional sense of in stent lesions based on ISR-Net algorithm. (time frame: one month). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05131191, which also lists 6 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Feb 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in