AzTrials
AzTrials

GlioblastomaNCT05140902

Accurate DCE-MRI Measurement of Glioblastoma Using Point-of-care Portable Perfusion Phantom

A study testing Point-of-care Portable Perfusion Phantom (P4) in people with Glioblastoma, run by University of Alabama at Birmingham at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The goal of this study is to test whether a new device developed at the University of Alabama at Birmingham (UAB) can decrease the error in calculating blood flow of a brain tumor, leading to better prognosis. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Glioblastoma
What is being tested?
Point-of-care Portable Perfusion Phantom (P4)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
12 participants
Where
1 siteUnited States
Study dates
28 Mar 2022to 25 Aug 2024
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Adult patients (age 18 years or older).
  • Patients treated with surgery, followed by chemoradiation therapy, and currently under chemotherapy.
  • Patients with a newly or enlarged enhancing lesion inside the radiation field at least three months after completion of radiation therapy.
  • Patients with signed informed consent.

Who cannot join

  • Participants with safety contraindications to MRI examination (determined by standard clinical screening).
  • Participants on hemodialysis or with acute renal failure.
  • Participants who are pregnant, lactating or are planning to become pregnant during the study.
  • Participants who are planning to farther a child during the study.

Trial locations and contacts

1 site in 1 country.

United States1 site
  • University of Alabama at Birmingham

    Birmingham, Alabama, 35294

Other trials in United States

About this study

The goal of this study is to test whether a new device developed at the University of Alabama at Birmingham (UAB) can decrease the error in calculating blood flow of a brain tumor, leading to better prognosis. UAB radiological research team has been studying a cutting-edge imaging technique named dynamic contrast enhanced (DCE) magnetic resonance imaging (MRI) , or DCE-MRI, over 10 years. This technique has been globally used to calculate blood flow of various tissues including tumors. Blood flow often serves as a critical indicator showing a disease status. For example, a brain tumor has typically high blood flow, so the magnitude of blood flow can be used as an indicator to identify the presence and aggressiveness of a brain tumor. In addition, an effective therapy can result in the alteration of the blood flow in a brain tumor. Therefore, the investigators may be able to determine whether the undergoing therapy is effective or not by measuring the blood flow in the brain tumor, and decide whether they need to continue the therapy or try a different one.

However, unfortunately, the measurement of blood flow using DCE-MRI is often inaccurate. MRI scanners may use different hardware and software thus the measurement may be different across scanners. The measurement may also be different over time due to hardware instability. Therefore, the investigators propose to use an artificial tissue, named "phantom", together with a patient. The phantom has a constant blood flow thus it can serve as a standard. Errors, if it occurs, will affect the images of both the patient and the phantom. Therefore, the investigators will be able to correct the errors in the patient image using the phantom image. UAB radiological research team invented a new device for this purpose named point-of-care portable perfusion phantom, or shortly P4. The team recently demonstrated the utility of the P4 phantom for accurate measurement of blood flow in pancreatic cancer and prostate cancer. In this study, they will test whether the P4 phantom will improve the measurement accuracy in brain cancer.

Read the detailed description

Glioblastoma is the most common primary malignant type of brain tumor in adults. Surgical tumor resection followed by chemoradiation therapy is the standard of care for patients with glioblastoma, but its prognosis is still fairly dismal (median survival time = 15 months). One major concern that prevents effective treatment management is the difficulty of differentiating between pseudo-progression and true-progression. Pseudo-progression occurs in about 20-30% of glioblastoma patients typically within 3 months after chemoradiation therapy has been completed. Pseudo-progression is a local inflammatory reaction caused by irradiation and enhanced by concurrent chemotherapy, which leads to a transient increase of blood brain barrier (BBB) permeability. The BBB, however, is also disrupted by new cancer occurrence. Therefore, both pseudo- and true-progressions appear with an increased contrast enhancement in MRI, and there are currently no established techniques to differentiate between them. Pseudo-progression is typically known to be associated with better clinical outcomes, so pseudo-progression mistaken for true-progression results in the discontinuation of an effective therapy, while true-progression mistaken for pseudo-progression leads to the continuation of an ineffective therapy that may induce adverse side effects. DCE-MRI has potential to differentiate between pseudo- and true-progressions of glioblastoma. The enhancing lesions of pseudo-progression are due to inflammation, whereas those of true-progression are caused by cancer growing. Thus, true-progression typically presents higher perfusion than pseudo-progression does. DCE-MRI can quantitatively assess the tissue perfusion by monitoring the dynamic change of MRI contrast agent concentration. Several investigators have demonstrated the potential of quantitative DCE-MRI to differentiate between pseudo- and true-progressions. However, the variability in quantitative DCE-MRI measurement across different MRI scanners remains a major concern, as it hinders data comparison among institutes to retrieve a reliable threshold for accurate prognosis and subsequent treatment optimization. A point-of-care perfusion phantom may allow high reproducibility and accurate comparison of quantitative DCE-MRI data across MRI platforms. The UAB radiological research team recently developed the P4 phantom, which is small enough to be imaged concurrently with a patient for real-time quality assurance, but large enough not to suffer from the partial volume effect. The P4 phantom creates constant contrast enhancement curves with very robust repeatability, and thus the contrast agent concentration time-course in a tumor, which is a major source of error in quantitating DCE-MRI parameters, can be accurately calculated in reference to the values observed in the phantom. In our previous study, the variability in quantitating the volume transfer constant of various human tissues across two different MRI scanners was reduced fivefold after P4-based error correction. The investigators hypothesize that the variability in quantitative DCE-MRI measurement of glioblastoma across different scanners will be significantly reduced when the P4 is used for error correction, leading to better differentiation between pseudo- and true-progressions. The goal of this study is to test this hypothesis.

Conditions
Glioblastoma
Being tested
Point-of-care Portable Perfusion Phantom (P4)
Medical subject headings
Glioblastoma

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Point-of-care Portable Perfusion Phantom (P4)Device

    P4 is a perfusion phantom developed by Dr. Harrison Kim that can significantly reduce variation in quantitating perfusion of human abdominal tissues across MRI scanners.

Study groups in NCT05140902
Study groupRoleWhat they receive
Glioblastoma patientsExperimentalglioblastoma patients with newly or enlarged enhancing lesion within 3 months after completing 6 weeks of adjuvant chemoradiation therapy
Receives: Device: Point-of-care Portable Perfusion Phantom (P4)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. To Measure the Reproducibility of qDCE-MRI Measurement of Glioblastoma.

    The goal is to measure the reproducibility of blood perfusion measurement in the glioblastoma using the two consecutive DCE-MRI scans with and without P4-based error correction.

    The pharmacokinetic (PK) parameter within the region of interest (ROI) will be averaged at each scan after P4-based error correction, and the mean values of two scans will be compared to calculate the coefficient of variation (%COV).

    Measured: At the end of Cycle 2 of chemoradiation therapy (each cycle is 28 days)

  2. The Differentiation Between the Pseudo- and True-progressions of Glioblastoma Can be Improved Using qDCE-MRI After P4-based Error Correction.

    The PK parameter (e.g., Ktrans) in the tumor with pseudoprogression will be statistically compared with that with true-progression before and after P4-based error correction to determine whether the differentiation between the pseudo- and true-progressions of glioblastoma can be improved using qDCE-MRI after P4-based error correction. Each tumor will be classified into pseudo- or true-progression based on RANO criteria.

    Measured: At the end of Cycle 2 of chemoradiation therapy (each cycle is 28 days)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted2 Dec 2021
  2. Study start28 Mar 2022
  3. Primary completion25 Aug 2024
  4. Study completion25 Aug 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
12 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05140902
Sponsor's protocol ID
300006446
Other IDs
UL1TR003096
Status last verified
Feb 2025
First submitted
3 Sep 2021
Last updated
14 Feb 2025
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: To be determined

Questions about this trial

What is this clinical trial studying?

A study testing Point-of-care Portable Perfusion Phantom (P4) in people with Glioblastoma, run by University of Alabama at Birmingham at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 14 Feb 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 14 Feb 2025). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

To Measure the Reproducibility of qDCE-MRI Measurement of Glioblastoma. (time frame: At the end of Cycle 2 of chemoradiation therapy (each cycle is 28 days)). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Feb 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in