A study testing Group video fiberscope of experienced practitioner, Group video laryngoscope of experienced practitioner and Group video fiberscope of less experienced practitioner in people with Intubation; Difficult or Failed and Airway Responsiveness, run by Ondokuz Mayıs University at 1 site in Turkey (Türkiye).

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Endotracheal intubation plays an important role in general anesthesia. Complications can be prevented by using alternative airway devices in predetermined difficult intubation cases. Read more about this study

Who is it for?
Ages 18 to 65 yearsHealthy volunteers can take part
What is being tested?
Group video fiberscope of experienced practitioner, Group video laryngoscope of experienced practitioner and Group video fiberscope of less experienced practitioner
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
60 participants
Where
1 siteTurkey (Türkiye)
Study dates
1 Nov 2018to 1 Mar 2019
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 65 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Operated in the operating room of our hospital,
  • Aged 18-65,
  • EGRI score>4,
  • ASA (American Society of Anesthesiologists) score<4

Who cannot join

  • Cerebrovascular disease (cerebral ischemia, hemorrhage or stroke), presence of carotid stenosis or history of coronary artery disease,
  • Neurological disorders (history of chronic headache, epilepsy or head trauma), alcohol or psychoactive drug addiction,
  • Serious heart and/or lung diseases, liver and/or kidney failure,
  • Uncontrolled diabetes and/or hypertension,
  • Dental abscess,
  • Mouth opening <1.5 cm,
Show all 11Show fewer
  • Known bleeding disorder,
  • Pregnancy,
  • Mental retardation,
  • Contraindications to drugs, allergy to drugs used,
  • Patient rejection

Trial locations and contacts

1 site in 1 country.

Turkey (Türkiye)1 site
  • Ondokuz Mayis University Faculty of Medicine

    Samsun, Atakum, 55200

Other trials in Turkey (Türkiye)

About this study

Official title: The Comparison Of Video Fiberscope And Video Laryngoscope,With Egri Score> 4

Endotracheal intubation plays an important role in general anesthesia. Complications can be prevented by using alternative airway devices in predetermined difficult intubation cases. In this study, the investigators aimed to compare the results of endotracheal intubation with video fiberscope and DCI video laryngoscope devices of two different experienced physicians (E and H).

Read the detailed description

In this randomized and prospective study, 60 patients with EGRI score> 4 and ASA score <4, operated between 1 October 2018 and 1 March 2019 in Ondokuz Mayıs University Medical Faculty Hospital were included. Endotracheal intubation was performed by two practitioners using two different devices. Intubation times, number of attempts, failed attempts, postoperative complications and hemodynamic responses were recorded.

Being tested
Group video fiberscope of experienced practitioner, Group video laryngoscope of experienced practitioner, Group video fiberscope of less experienced practitioner, Group video laryngoscope of less experienced practitioner

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Group video fiberscope of experienced practitionerDevice

    One of the classical alternatives to laryngoscopy in difficult endotracheal intubation is video laryngoscopyvideo fiberscope( Karl Storz GmbH \&Co. KG, Tuttlingen, Germany). Reaching the image from the patient with pre- and from the cervical point of view, or from the cervical point of view, to be completed with a good view from a large screen to be completed with an image before and within intubation. It also facilitates learning in education.

  • Group video laryngoscope of experienced practitionerDevice

    Intubation Pending Difficult as well as challenging . Fiberoptic (fiberscope) intubation is the gold standard in difficult airway. Lacking this supplement, it will be widely used for practice, as it is suitable for video laryngeal.

  • Group video fiberscope of less experienced practitionerDevice

    One of the classical alternatives to laryngoscopy in difficult endotracheal intubation is video laryngoscopy video fiberscope( Karl Storz GmbH \&Co. KG, Tuttlingen, Germany). Reaching the image from the patient with pre- and from the cervical point of view, or from the cervical point of view, to be completed with a good view from a large screen to be completed with an image before and within intubation. It also facilitates learning in education.

  • Group video laryngoscope of less experienced practitionerDevice

    Entubation pending difficult as well as challenging . Fiberoptic (fiberscope) intubation is the gold standard in difficult airway. Lacking this supplement, it will be widely used for practice, as it is suitable for video laryngeal.Storz DCI Video Laryngoscope (Karl Storz GmbH \&Co. KG, Tuttlingen, Germany)

Study groups in NCT05243758
Study groupRoleWhat they receive
Group video fiberscope of experienced practitionerActive comparatorMore experienced physician: endotracheal intubation with video fiberscope Assoc. Dr. The group in which Ersin Köksal performed endotracheal intubation using a video fiberscope( Karl Storz GmbH \&Co. KG, Tuttlingen, Germany) consisted of 15 patients.Endotracheal intubation was performed by two practitioners using two different devices. Intubation times, number of attempts, failed attempts, postoperative complications and hemodynamic responses were recorded.
Receives: Device: Group video fiberscope of experienced practitioner; Device: Group video fiberscope of less experienced practitioner
Group video laryngoscope of experienced practitionerActive comparatorMore experienced physician: Endotracheal intubation with DCI video laryngoscopeThe group in which Assoc. Dr. Ersin Köksal performed endotracheal intubation using a DCI video laryngoscope(Storz DCI Video Laryngoscope (Karl Storz GmbH \&Co. KG, Tuttlingen, Germany) consisted of 15 patients.Endotracheal intubation was performed by two practitioners using two different devices. Intubation times, number of attempts, failed attempts, postoperative complications and hemodynamic responses were recorded.
Receives: Device: Group video laryngoscope of experienced practitioner; Device: Group video laryngoscope of less experienced practitioner
Group video fiberscope of less experienced practitionerActive comparatorEndotracheal intubation with video fiberscope: The group in which DrHalil Cebeci applied endotracheal intubation using a video fiberscope( Karl Storz GmbH \&Co. KG, Tuttlingen, Germany) consisted of 15 patients. Endotracheal intubation was performed by two practitioners using two different devices. Intubation times, number of attempts, failed attempts, postoperative complications and hemodynamic responses were recorded.
Receives: Device: Group video fiberscope of experienced practitioner; Device: Group video fiberscope of less experienced practitioner
Group video laryngoscope of less experienced practitionerActive comparatorEndotracheal intubation with DCI video laryngoscope:The group in which Dr.Halil Cebeci applied endotracheal intubation using a DCI video laryngoscope(Karl Storz GmbH \&Co. KG, Tuttlingen, Germany) consisted of 15 patients.Endotracheal intubation was performed by two practitioners using two different devices. Intubation times, number of attempts, failed attempts, postoperative complications and hemodynamic responses were recorded.
Receives: Device: Group video laryngoscope of experienced practitioner; Device: Group video laryngoscope of less experienced practitioner

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Intubation times,

    The moment when the endotracheal intubation tube was passed between the vocal cords following the vocal cord image obtained with the device was recorded in seconds. In endotracheal intubation performed with a video fiberscope, the end of the fiberscope with a camera passing through the vocal cords, and in endotracheal intubation performed with a DCI video laryngoscope, the intubation tube passing between the vocal cords was counted as successful intubation time.

    Measured: during intubation

  2. Number of attempts

    The procedure will be considered unsuccessful if intubation is unsuccessful in three attempts, if the intubation process exceeds three minutes, or if the peripheral oxygen saturation (SpO2) is <90% during this period. If this situation was encountered, it was planned to ventilate the patient with an anesthesia mask until the oxygen saturation approached 100% and to use alternative airway devices.

    Measured: during intubation for patients,

  3. Time to find the glottis:

    The time from the moment the device entered between the patient's anterior incisors until the vocal cords were seen was recorded in seconds.

    Measured: during intubation for patients

  4. Blood pressure

    Hemodynamic parameters; heart rate (/min), systolic blood pressure (mmHg), diastolic blood pressure (mmHg), mean arterial pressure (mmHg), and SpO2 were recorded before induction (baseline), during intubation, at 1st, 2nd and 5th minutes after intubation

    Measured: During intubation, at 1st, 2nd and 5th minutes after intubation

  5. Pulse oximeter

    Oximetry is a convenient and painless alternative to needlesticks, is simple to use, and provides immediate data. These advantages make oximetry an invaluable tool for determination the client's need for oxygen therapy and assessing effectiveness of therapy. The oximeter registers arterial oxygen saturation (SaO2). An SaO2 greater than 95% is considered normal, whereas values lower than 93% usually indicate the need for oxygen therapy and further assessment.

    Measured: Before induction (baseline), during intubation, at 1st, 2nd and 5th minutes after intubation

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted17 Feb 2022
  2. Study start1 Nov 2018
  3. Primary completion1 Mar 2019
  4. Study completion1 Mar 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Screening
Allocation
Randomised
Intervention model
Crossover
Model description
60 patients aged between 18-65 years, who were operated in the operating room of our hospital, with an EGRI score of \>4 and an ASA (American Society of Anesthesiologists) score of \<4 were included.
Masking
Single blind
Who is masked
Participant
Enrolment
60 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05243758
Sponsor's protocol ID
B.30.2.ODM.0.20.08/1822
Status last verified
Nov 2018
First submitted
5 Dec 2021
Last updated
17 Feb 2022
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Group video fiberscope of experienced practitioner, Group video laryngoscope of experienced practitioner and Group video fiberscope of less experienced practitioner in people with Intubation; Difficult or Failed and Airway Responsiveness, run by Ondokuz Mayıs University at 1 site in Turkey (Türkiye).

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 11 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 17 Feb 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Intubation times, (time frame: during intubation). The study lists 5 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Feb 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in