AzTrials
AzTrials

Voiding DisordersNCT05295823

Patient Self Measurement of Post-Void Residual Bladder Volume (PVR) Using Ultrasound

A study testing Butterfly portable ultrasound device with bladder ultrasound images and Butterfly portable ultrasound device with abstract bladder images in people with Voiding Disorders and Voiding Dysfunction, run by Yale University at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study would be the first to demonstrate feasibility, accuracy, reliability, clinical care impact, and patient satisfaction with remote monitoring of post-void residual bladder volume (PVR) using the Butterfly portable ultrasound device in patients with obstructive voiding dysfunction. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Voiding Disorders, Voiding Dysfunction
What is being tested?
Butterfly portable ultrasound device with bladder ultrasound images and Butterfly portable ultrasound device with abstract bladder images
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
50 participants
Where
1 siteUnited States
Study dates
27 Apr 2022to 3 Jun 2022
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patient with capacity to consent to the study and completion of informed consent document
  • Ability to speak and read English

Who cannot join

  • Patient without capacity to consent to the study or incompletion of informed consent document
  • Inability to speak and read English

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Yale New Haven Hospital

    New Haven, Connecticut, 06520

Other trials in United States

About this study

This study would be the first to demonstrate feasibility, accuracy, reliability, clinical care impact, and patient satisfaction with remote monitoring of post-void residual bladder volume (PVR) using the Butterfly portable ultrasound device in patients with obstructive voiding dysfunction.

Read the detailed description

This study would be the first to demonstrate feasibility, accuracy, reliability, and patient satisfaction with self measurement of PVR using the Butterfly portable ultrasound device.

In the current study protocol, participants will undergo routine clinical care with no additional clinical encounters for the purposes of this study. As part of routine clinical care, the patient will undergo 3 sequential measurements of patient PVR by the Urologic healthcare provider using the existing ultrasound technology, and a possible bladder catheterization for actual bladder volume measurement and to drain the bladder. Note that 3 sequential measurements are taken from which a mean and standard deviation are derived due to operator and technology-related variability in bladder volume measurement using ultrasound. Participants in the study will also undergo 3 sequential measurements of patient PVR by the Urologic healthcare provider using the Butterfly portable ultrasound device with ultrasound images of the bladder, and 3 sequential measurements of patient PVR by the Urologic healthcare provider using the Butterfly portable ultrasound device with abstract images of the bladder; and the participant will take 3 sequential self-measurements of PVR using the Butterfly portable ultrasound device with ultrasound images of the bladder and 3 sequential self-measurements of PVR using the Butterfly portable ultrasound device with abstract images of the bladder during the same clinic encounter. The Urologic healthcare provider might also perform a bladder catheterization of the patient to determine the actual PVR and to drain the bladder of the residual urine.

Ultimately, successful remote measurement of patient PVR may lead to a paradigm shift in how patients with voiding dysfunction are clinically monitored; and would be a critical tool in triaging patients with possible urinary retention at any time but most especially during a pandemic necessitating social distancing and judicious allocation of healthcare resources. Remote PVR measurement in patients with obstructive voiding dysfunction may lead to more accurate monitoring for urinary retention; early detection of and intervention for urinary retention and potential prevention of sequelae such as urinary tract infection/urosepsis, renal failure, and bladder failure; potential reduction in medical costs and travel burden by reducing unnecessary clinic and emergency room visits as well as the costs of treating potential sequelae of urinary retention; and better quality of life for patients with obstructive voiding dysfunction.

Ultrasound technology is non-invasive, uses sound waves (non-ionizing radiation) to produce a volume measurement, and is an exceptionally safe method of imaging with a very limited risk profile.

Being tested
Butterfly portable ultrasound device with bladder ultrasound images, Butterfly portable ultrasound device with abstract bladder images
Keywords
post void residual bladder volume, portable usltrasound

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Butterfly portable ultrasound device with bladder ultrasound imagesDevice

    Point-of-care PVR measurement using existing ultrasound technology (3 consecutive measurements during the same encounter) the Butterfly portable ultrasound device with bladder ultrasound images

  • Butterfly portable ultrasound device with abstract bladder imagesDevice

    Point-of-care PVR measurement using the Butterfly portable ultrasound device with abstract bladder images

Study groups in NCT05295823
Study groupRoleWhat they receive
Healthcare provider performed standard PVR measurement using existing ultrasound technologyNo interventionThe Urologic healthcare provider will perform standard point-of-care PVR measurement on the participant (3 consecutive measurements during the same encounter) using existing ultrasound technology
Healthcare provider performed PVR measurement using Butterfly and bladder ultrasound imagesExperimentalThe Urologic healthcare provider will perform PVR measurement on the participant (3 consecutive measurements during the same encounter) using the Butterfly and bladder ultrasound images
Receives: Device: Butterfly portable ultrasound device with bladder ultrasound images
Healthcare provider performed PVR measurement using Butterfly and abstract bladder imagesExperimentalThe Urologic healthcare provider will perform PVR measurement on the participant (3 consecutive measurements during the same encounter) using the Butterfly and abstract bladder images
Receives: Device: Butterfly portable ultrasound device with abstract bladder images
Self PVR measurement using Butterfly and bladder ultrasound imagesExperimentalThe participant will perform self PVR measurement (3 consecutive measurements during the same encounter) using the Butterfly and bladder ultrasound images (prior to catheterization, if needed)
Receives: Device: Butterfly portable ultrasound device with bladder ultrasound images
Self PVR measurement using Butterfly and abstract bladder imagesExperimentalThe participant will perform self PVR measurement (3 consecutive measurements during the same encounter) using the Butterfly and abstract bladder images (prior to catheterization, if needed)
Receives: Device: Butterfly portable ultrasound device with abstract bladder images

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Accuracy of self-measurement of PVR using the Butterfly with bladder ultrasound images compared to the Butterfly with abstract bladder images measured by Bland-Altman analysis.

    Accuracy of the patient self-measurement of PVR using the Butterfly portable ultrasound device with bladder ultrasound images compared to the Butterfly portable ultrasound device with abstract bladder images during the same encounter. It is measured by Bland-Altman analysis which describes agreement between two quantitative measurements. More agreement means less difference between measurements.

    Measured: up to 6 months

  2. Accuracy of self-measurement of PVR using the Butterfly with bladder ultrasound images compared to the healthcare provider's measurements of patient PVR using the Butterfly with bladder ultrasound images measured by Bland-Altman analysis.

    Accuracy of the patient self-measurement of PVR using the Butterfly portable ultrasound device with bladder ultrasound images compared to the healthcare provider's measurements of patient PVR using the Butterfly portable ultrasound device with bladder ultrasound images during the same encounter. It is measured by Bland-Altman analysis which describes agreement between two quantitative measurements. More agreement means less difference between measurements.

    Measured: up to 6 months

  3. Accuracy of self-measurement of PVR using the Butterfly with bladder ultrasound images compared to the healthcare provider's measurements of patient PVR using the Butterfly with abstract bladder images measured by Bland-Altman analysis.

    Accuracy of the patient self-measurement of PVR using the Butterfly portable ultrasound device with bladder ultrasound images compared to the healthcare provider's measurements of patient PVR using the Butterfly portable ultrasound device with abstract bladder images during the same encounter. It is measured by Bland-Altman analysis which describes agreement between two quantitative measurements. More agreement means less difference between measurements.

    Measured: up to 6 months

  4. Accuracy of patient self-measurement of PVR using the Butterfly with bladder ultrasound images compared to the healthcare provider's measurements of patient PVR using the existing ultrasound technology measured by Bland-Altman analysis.

    Accuracy of the patient self-measurement of PVR using the Butterfly portable ultrasound device with bladder ultrasound images compared to the healthcare provider's measurements of patient PVR using the existing ultrasound technology during the same encounter. It is measured by Bland-Altman analysis which describes agreement between two quantitative measurements. More agreement means less difference between measurements.

    Measured: up to 6 months

  5. Accuracy of patient self-measurement of PVR using the Butterfly with bladder ultrasound images compared to the healthcare provider's bladder catheterization of the patient measured by Bland-Altman analysis.

    Accuracy of the patient self-measurement of PVR using the Butterfly portable ultrasound device with bladder ultrasound images compared to the healthcare provider's measurements from bladder catheterization of the patient during the same encounter. It is measured by Bland-Altman analysis which describes agreement between two quantitative measurements. More agreement means less difference between measurements.

    Measured: up to 6 months

Secondary outcomes (1)
  1. Patient Reported Outcomes Questionnaire to asses ease of use, satisfaction, and preference of Butterfly Device

    Patient Reported Outcomes Questionnaire to assess patient-reported ease of use, satisfaction, and preference between using bladder ultrasound images or abstract bladder images for self measurement of PVR with the Butterfly device using a patient questionnaire at the conclusion of patient self measurements. A mix of open-ended and multiple-choice questions using a 5-point Likert scale of responses.

    Measured: up to 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted25 Mar 2022
  2. Study start27 Apr 2022
  3. Primary completion3 Jun 2022
  4. Study completion3 Jun 2022

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Device feasibility
Allocation
Randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Participant, Care provider
Enrolment
50 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05295823
Sponsor's protocol ID
2000031258
Status last verified
Mar 2023
First submitted
15 Mar 2022
Last updated
15 Mar 2023
Results posted
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Butterfly portable ultrasound device with bladder ultrasound images and Butterfly portable ultrasound device with abstract bladder images in people with Voiding Disorders and Voiding Dysfunction, run by Yale University at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 15 Mar 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Accuracy of self-measurement of PVR using the Butterfly with bladder ultrasound images compared to the Butterfly with abstract bladder images measured by Bland-Altman analysis. (time frame: up to 6 months). The study lists 5 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Mar 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in