AzTrials
AzTrials

AdenomaNCT05318495

A Dual Tandem Study - SC vs. CAD-EYE vs. CAD-EYE With G-EYE

A study testing Standard Colonoscopy, CAD-EYE and G-EYE in people with Adenoma and Colo-rectal Cancer, run by Dr. Horst Schmidt Klinik GmbH at 1 site in Germany.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Single-center, four-arm dual-tandem, randomized, open-label study involving the following devices: 1. The Standard Colonoscope is a high-definition colonoscope employing advanced optical filtering and enhancement techniques - blue light imaging (BLI) and linked color imaging (LCI). 2. Read more about this study

Who is it for?
Any ageHealthy volunteers can take part
Conditions the study is for
Adenoma, Colo-rectal Cancer
What is being tested?
Standard Colonoscopy, CAD-EYE and G-EYE
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
372 participants
Where
1 siteGermany
Study dates
1 Mar 2022to Dec 2022
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult, Older adult

Who may be able to join

  • Screening and surveillance population for Adenoma and CRC.
  • The patient must understand and sign a written informed consent for the procedure.

Who cannot join

  • Subjects with inflammatory bowel disease;
  • Subjects with a personal history of hereditary polyposis syndrome;
  • Subjects with suspected chronic stricture potentially precluding complete colonoscopy;
  • Subjects with diverticulitis or toxic megacolon;
  • Subjects with prior colonic surgery (exclusion appendectomy)
  • Subjects with a history of radiation therapy to abdomen or pelvis;
Show all 11Show fewer
  • Pregnant or lactating female subjects;
  • Subjects who are currently enrolled in another clinical investigation.
  • Subjects with current oral or parenteral use of anticoagulants, not considered eligible by the investigator.
  • Subjects with recent (within the last 3 mounts) coronary ischemia or CVA (stroke)
  • Any patient condition deemed too risky for the study by the investigator

Trial locations and contacts

1 site in 1 country.

Germany1 site, 1 recruiting
  • Helios Dr. Horst Schmidt Kliniken

    Wiesbaden, 65199

    Ralf Kiesslich, Prof., 49-611432421, ralf.kiesslich@helios-gesundheit.de

    Recruiting

Other trials in Germany

About this study

Official title: A Dual Tandem Study Comparing the Adenoma Detection and Miss-rate of SC to That of Artificial Intelligence (CAD-EYE) Aided Colonoscopy and to That of Artificial Intelligence (CAD-EYE) and G-EYE® Aided Colonoscopy.

Single-center, four-arm dual-tandem, randomized, open-label study involving the following devices:

  1. The Standard Colonoscope is a high-definition colonoscope employing advanced optical filtering and enhancement techniques - blue light imaging (BLI) and linked color imaging (LCI).
  2. CAD-EYE is an artificial intelligence software, used in real-time during the colonoscopy procedure for aiding the identification and characterization of polyps and adenomas.
  3. The G-EYE® balloon is a reusable (reprocessable) balloon permanently installed on the distal tip of a standard colonoscope, and is also intended to assist in flattening colonic folds and control the colonoscope's field of view and tip positioning.
Read the detailed description

Single-center, four-arm dual-tandem, randomized, open-label study involving the following devices:

  1. The Standard Colonoscope is a high-definition colonoscope employing advanced optical filtering and enhancement techniques - blue light imaging (BLI) and linked color imaging (LCI).
  2. CAD-EYE is an artificial intelligence software, used in real-time during the colonoscopy procedure for aiding the identification and characterization of polyps and adenomas.
  3. The G-EYE® balloon is a reusable (reprocessable) balloon permanently installed on the distal tip of a standard colonoscope, and is also intended to assist in flattening colonic folds and control the colonoscope's field of view and tip positioning.

Total of up to 372 patients will be randomized,186 to each of the two tandems

Being tested
Standard Colonoscopy, CAD-EYE, G-EYE
Medical subject headings
Adenoma, Colonic Neoplasms

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Standard ColonoscopyDevice

    The Standard Colonoscope is a high-definition colonoscope employing advanced optical filtering and enhancement techniques - blue light imaging (BLI) and linked color imaging (LCI).

  • CAD-EYEDevice

    CAD-EYE is an artificial intelligence software, used in real-time during the colonoscopy procedure for aiding the identification and characterization of polyps and adenomas.

  • G-EYEDevice

    The G-EYE® balloon is a reusable (reprocessable) balloon permanently installed on the distal tip of a standard colonoscope, and is also intended to assist in flattening colonic folds and control the colonoscope's field of view and tip positioning.

Study groups in NCT05318495
Study groupRoleWhat they receive
Standard Colonoscopy+CAD-EYE followed by Standard ColonoscopyExperimentalCAD-EYE is an artificial intelligence software, used in real-time during the colonoscopy procedure for aiding the identification and characterization of polyps and adenomas. The Standard Colonoscope is a high-definition colonoscope employing advanced optical filtering and enhancement techniques - blue light imaging (BLI) and linked color imaging (LCI).
Receives: Device: Standard Colonoscopy; Device: CAD-EYE
Standard Colonoscopy followed by Standard Colonoscopy+CAD-EYEActive comparatorCAD-EYE is an artificial intelligence software, used in real-time during the colonoscopy procedure for aiding the identification and characterization of polyps and adenomas. The Standard Colonoscope is a high-definition colonoscope employing advanced optical filtering and enhancement techniques - blue light imaging (BLI) and linked color imaging (LCI).
Receives: Device: Standard Colonoscopy; Device: CAD-EYE
Standard Colonoscopy+CAD-EYE+G-EYE followed by Standard ColonoscopyExperimentalCAD-EYE is an artificial intelligence software, used in real-time during the colonoscopy procedure for aiding the identification and characterization of polyps and adenomas. The Standard Colonoscope is a high-definition colonoscope employing advanced optical filtering and enhancement techniques - blue light imaging (BLI) and linked color imaging (LCI). The G-EYE® balloon is a reusable (reprocessable) balloon permanently installed on the distal tip of a standard colonoscope, and is also intended to assist in flattening colonic folds and control the colonoscope's field of view and tip positioning.
Receives: Device: Standard Colonoscopy; Device: CAD-EYE; Device: G-EYE
Standard Colonoscopy followed by Standard Colonoscopy+CAD-EYE+G-EYEActive comparatorCAD-EYE is an artificial intelligence software, used in real-time during the colonoscopy procedure for aiding the identification and characterization of polyps and adenomas. The Standard Colonoscope is a high-definition colonoscope employing advanced optical filtering and enhancement techniques - blue light imaging (BLI) and linked color imaging (LCI). The G-EYE® balloon is a reusable (reprocessable) balloon permanently installed on the distal tip of a standard colonoscope, and is also intended to assist in flattening colonic folds and control the colonoscope's field of view and tip positioning.
Receives: Device: Standard Colonoscopy; Device: CAD-EYE; Device: G-EYE

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Additional adenoma detection yield

    additional adenoma detection yield (represented by the miss rate) of CAD-EYE and G-EYE® colonoscopy over standard coloscopy compared to the additional adenoma detection yield of CAD-EYE aided colonoscopy over standard colonoscopy

    Measured: 6 weeks

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted8 Apr 2022
  2. Study start1 Mar 2022
  3. Primary completionDec 2022 (estimated)
  4. Study completionDec 2022 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Screening
Allocation
Randomised
Intervention model
Crossover
Masking
None (open label)
Enrolment
372 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05318495
Sponsor's protocol ID
Dual Tandem
Status last verified
Apr 2022
First submitted
29 Mar 2022
Last updated
8 Apr 2022
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing Standard Colonoscopy, CAD-EYE and G-EYE in people with Adenoma and Colo-rectal Cancer, run by Dr. Horst Schmidt Klinik GmbH at 1 site in Germany.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 11 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 8 Apr 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Ralf Kiesslich, Prof. (49-611432421, Ralf.Kiesslich@helios-gesundheit.de), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Additional adenoma detection yield (time frame: 6 weeks). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Apr 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in