Cardiac Rhythm DisorderNCT05327101
Patient Preferences for Leadless Pacemakers
An observational study of Cardiac Rhythm Disorder and Bradycardia, run by Abbott Medical Devices at 11 sites in United States.
Trial summary
Prospective, non-randomized, multi-center study designed to quantify patient preferences pertaining to risks and features of conventional transvenous pacemakers and leadless pacemakers Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Cardiac Rhythm Disorder, Bradycardia, Cardiac Pacemaker Artificial
- What is being tested?
- Patient Preference Survey
- How many people
- 117 participants
- Where
- 11 sitesUnited States
- Study dates
- 28 Mar 2022to 13 Jun 2023
- How long will I take part?
- 1 Day
- Phase
- Observational
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Adult, Older adult
Study population: 300 patients
Who may be able to join
- Able to read and speak English to consent to participate in the survey
- Willing and able to use a tablet or computer to complete the survey
- Scheduled to undergo evaluation for a de novo cardiac pacemaker at the study site (patient may or may not have a known indication for a pacemaker at the time)
Who cannot join
- None
Trial locations and contacts
11 sites in 1 country.
11 sites in 1 country
United States11 sites
Rush University Medical Center
Chicago, Illinois, 60612
Charlton Memorial Hospital
Fall River, Massachusetts, 02720
Baptist Medical Center
Jacksonville, Florida, 32207
Arrhythmia Research Group
Jonesboro, Arkansas, 72401
Arkansas Heart Hospital
Little Rock, Arkansas, 72211
New York Presbyterian Hospital/Cornell University
New York, New York, 10021
Hightower Clinical
Oklahoma City, Oklahoma, 73102
University of Utah Hospital
Salt Lake City, Utah, 84132
Pacific Heart Institute
Santa Monica, California, 90404
Honor Health
Scottsdale, Arizona, 85258
Prairie Education & Research Cooperative
Springfield, Illinois, 62769
About this study
Official title: Quantifying Patient Preferences for Leadless Pacemaker Devices
Prospective, non-randomized, multi-center study designed to quantify patient preferences pertaining to risks and features of conventional transvenous pacemakers and leadless pacemakers
Read the detailed description
The purpose of this study is to quantify patient preferences pertaining to risks and features of conventional transvenous pacemakers and leadless pacemakers. The preference study is designed to elicit patient preferences for risks and features that vary between a dual chamber leadless pacemaker system and a dual chamber transvenous pacemaker system, to quantify their relative importance.
- Being tested
- Patient Preference Survey
- Medical subject headings
- Arrhythmias, Cardiac, Bradycardia
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Patient Preference SurveyOther
Patient preference survey on implantable cardiac pacemaker systems
What is being measured
The primary outcome is the main question the study is designed to answer.
Mean Rankings for Pacemaker Device Features
Ranking of six pacemaker device features from most concerning (1) to least concerning (6)
Measured: Baseline
Results From RPL Model of Discrete Choice Experiment Choice Questions - Preference Weights (Effect-coded Parameters)
The preference weights for the RPL model. Effect-coded parameters generate log-odds preference weights representing the relative strength of preference for each attribute level versus the mean effect across levels normalized at zero. A higher weight indicates a more preferred level while a lower weight indicates a less preferred level.
Measured: Baseline
Results From RPL Model of Discrete Choice Experiment Choice Questions- Standard Deviations
The standard deviations representing the degree of variation in preference weights, with larger estimates representing preference heterogeneity.
Measured: Baseline
Maximum-acceptable Risks of a Complication
Maximum-acceptable risk (MAR) of a complication was calculated for patients based off latent-class analysis with two groups-leadless class and transvenous class (see secondary outcome Constrained 2-class Latent-class model preference weights). The MAR represents risk level patients would be willing to accept to obtain their preferred pacemaker type, no discomfort, a device with longer battery life, and a device with more time since regulatory approval.
Measured: Baseline
Maximum-acceptable Risks of an Infection
Maximum-acceptable risk (MAR) of an infection was calculated for patients based off latent-class analysis with two groups-leadless class and transvenous class (see secondary outcome Constrained 2-class Latent-class model preference weights). The MAR represent the risk that patients would be willing to accept to obtain their preferred pacemaker type, no discomfort, a device with longer battery life, and a device with more time since regulatory approval.
Measured: Baseline
Probability of Choosing Specified Pacemakers - All 3 Profiles
Preference weight estimates were used to calculate the predicted probabilities that patients would choose a hypothetical pacemaker profile out of three different pacemaker types- leadless pacemaker removable, leadless pacemaker non-removable, or pacemaker with leads. Attributes for each pacemaker profile were defined using historical or published values. Preference weights from the latent class model were used to compute the probability that respondents within each class preference would choose a pacemaker profile over another.
Measured: Baseline
Probability of Choosing Specified Pacemakers - Leadless Pacemaker Removable vs. Leadless Pacemaker Non-removable
Preference weight estimates were used to calculate the predicted probabilities that patients would choose a hypothetical pacemaker profile out of three different pacemaker types- leadless pacemaker removable or leadless pacemaker non-removable. Attributes for each pacemaker profile were defined using historical or published values. Preference weights from the latent class model were used to compute the probability that respondents within each class preference would choose a pacemaker profile over another.
Measured: Baseline
Probability of Choosing Specified Pacemakers - Leadless Pacemaker Removable vs. Pacemaker With Leads
Preference weight estimates were used to calculate the predicted probabilities that patients would choose a hypothetical pacemaker profile out of three different pacemaker types- leadless pacemaker removable or pacemaker with leads. Attributes for each pacemaker profile were defined using historical or published values. Preference weights from the latent class model were used to compute the probability that respondents within each class preference would choose a pacemaker profile over another.
Measured: Baseline
Probability of Choosing Specified Pacemakers - Leadless Pacemaker Non-removable vs. Pacemaker With Leads
Preference weight estimates were used to calculate the predicted probabilities that patients would choose a hypothetical pacemaker profile out of three different pacemaker types- leadless pacemaker non-removable or pacemaker with leads. Attributes for each pacemaker profile were defined using historical or published values. Preference weights from the latent class model were used to compute the probability that respondents within each class preference would choose a pacemaker profile over another.
Measured: Baseline
Secondary outcomes (3)
Constrained 2-class Latent-class Model Preference Weights
Latent-class (LC) analysis was used to identify systematically different preference patterns across respondents. LC analysis provides a unique set of estimates of preference weights for a prespecified number of preference classes. Respondents are probabilistically assigned to classes based on the similarity of their responses to the overall preference pattern identified in each class.
Measured: Baseline
Number of Discrete Choice Experiment Questions Answered
Number of Discrete choice experiment (DCE) questions answered by 117 respondents who answered at least the first 8 DCE questions. After respondents answered 8 DCE questions, they were asked if they would like to complete 4 additional questions.
Measured: Baseline
Association of Patient Characteristics With Membership in the Transvenous Class Versus the Leadless Class
Respondent characteristics can be associated with class membership probabilities to "profile" the classes. These results show if respondents with certain characteristics are more likely to be in one class versus the other. The odds ratios of being in the transvenous class versus the leadless class for patient characteristics. Odds ratios greater than 1 indicate a higher likelihood of being in the class preferring transvenous pacemakers and pacemakers with longer time since government approval.
Measured: Baseline
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted14 Apr 2022
- Study start28 Mar 2022
- Primary completion13 Jun 2023
- Study completion13 Jun 2023
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Cardiac Rhythm DisorderStudies of the same condition, open and under way.
- More trials run by Abbott Medical DevicesThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 117 participants (actual)
- Target duration
- 1 Day
Sponsor and investigators
- Lead sponsor
- Abbott Medical Devices
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Shelby Reed, PhD, Principal investigator, Duke Clinical Research Institute
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05327101
- Sponsor's protocol ID
- ABT-CIP-10435
- Status last verified
- Jan 2025
- First submitted
- 4 Apr 2022
- Last updated
- 20 Feb 2025
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided
Publications
Reed SD, Yang JC, Wallace MJ, Sutphin J, Johnson FR, Ozdemir S, Delgado SM, Goates S, Harbert N, Lo M, Rajagopalan B, Ip JE, Al-Khatib SM. Patient Preferences for Features Associated With Leadless Versus Conventional Transvenous Cardiac Pacemakers. Circ Cardiovasc Qual Outcomes. 2024 Dec;17(12):e011168. doi: 10.1161/CIRCOUTCOMES.124.011168. Epub 2024 Nov 21.
PubMed 39569505
Study at a glance
From the registry record, last updated by the sponsor on 20 Feb 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Quantifying Patient Preferences for Leadless Pacemaker Devices
- ClinicalTrials.gov ID
- NCT05327101
- Acronym / sponsor ID
- ABT-CIP-10435
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 117 participants (actual)
- Lead sponsor
- Abbott Medical DevicesIndustry (pharma, biotech, devices)
- Study start
- 28 Mar 2022 (actual)
- Primary completion
- 13 Jun 2023 (actual)
- Study completion
- 13 Jun 2023 (actual)
- First posted
- 14 Apr 2022 (actual)
- Results
- Posted 20 Feb 2025
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Prospective, non-randomized, multi-center study designed to quantify patient preferences pertaining to risks and features of conventional transvenous pacemakers and leadless pacemakers
Detailed description
The purpose of this study is to quantify patient preferences pertaining to risks and features of conventional transvenous pacemakers and leadless pacemakers. The preference study is designed to elicit patient preferences for risks and features that vary between a dual chamber leadless pacemaker system and a dual chamber transvenous pacemaker system, to quantify their relative importance.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Target follow-up
- 1 Day
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Age groups
- Adult, Older adult
- Study population
- 300 patients
Key inclusion criteria (3 listed)
- Able to read and speak English to consent to participate in the survey
- Willing and able to use a tablet or computer to complete the survey
- Scheduled to undergo evaluation for a de novo cardiac pacemaker at the study site (patient may or may not have a known indication for a pacemaker at the time)
Key exclusion criteria (1 listed)
- None
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Patient Preference SurveyPatient preference survey on implantable cardiac pacemaker systems | Other | – |
Primary outcome
Mean Rankings for Pacemaker Device Features
Time frame: Baseline
Ranking of six pacemaker device features from most concerning (1) to least concerning (6)
Results From RPL Model of Discrete Choice Experiment Choice Questions - Preference Weights (Effect-coded Parameters)
Time frame: Baseline
The preference weights for the RPL model. Effect-coded parameters generate log-odds preference weights representing the relative strength of preference for each attribute level versus the mean effect across levels normalized at zero. A higher weight indicates a more preferred level while a lower weight indicates a less preferred level.
Results From RPL Model of Discrete Choice Experiment Choice Questions- Standard Deviations
Time frame: Baseline
The standard deviations representing the degree of variation in preference weights, with larger estimates representing preference heterogeneity.
Maximum-acceptable Risks of a Complication
Time frame: Baseline
Maximum-acceptable risk (MAR) of a complication was calculated for patients based off latent-class analysis with two groups-leadless class and transvenous class (see secondary outcome Constrained 2-class Latent-class model preference weights). The MAR represents risk level patients would be willing to accept to obtain their preferred pacemaker type, no discomfort, a device with longer battery life, and a device with more time since regulatory approval.
Maximum-acceptable Risks of an Infection
Time frame: Baseline
Maximum-acceptable risk (MAR) of an infection was calculated for patients based off latent-class analysis with two groups-leadless class and transvenous class (see secondary outcome Constrained 2-class Latent-class model preference weights). The MAR represent the risk that patients would be willing to accept to obtain their preferred pacemaker type, no discomfort, a device with longer battery life, and a device with more time since regulatory approval.
Probability of Choosing Specified Pacemakers - All 3 Profiles
Time frame: Baseline
Preference weight estimates were used to calculate the predicted probabilities that patients would choose a hypothetical pacemaker profile out of three different pacemaker types- leadless pacemaker removable, leadless pacemaker non-removable, or pacemaker with leads. Attributes for each pacemaker profile were defined using historical or published values. Preference weights from the latent class model were used to compute the probability that respondents within each class preference would choose a pacemaker profile over another.
Probability of Choosing Specified Pacemakers - Leadless Pacemaker Removable vs. Leadless Pacemaker Non-removable
Time frame: Baseline
Preference weight estimates were used to calculate the predicted probabilities that patients would choose a hypothetical pacemaker profile out of three different pacemaker types- leadless pacemaker removable or leadless pacemaker non-removable. Attributes for each pacemaker profile were defined using historical or published values. Preference weights from the latent class model were used to compute the probability that respondents within each class preference would choose a pacemaker profile over another.
Probability of Choosing Specified Pacemakers - Leadless Pacemaker Removable vs. Pacemaker With Leads
Time frame: Baseline
Preference weight estimates were used to calculate the predicted probabilities that patients would choose a hypothetical pacemaker profile out of three different pacemaker types- leadless pacemaker removable or pacemaker with leads. Attributes for each pacemaker profile were defined using historical or published values. Preference weights from the latent class model were used to compute the probability that respondents within each class preference would choose a pacemaker profile over another.
Probability of Choosing Specified Pacemakers - Leadless Pacemaker Non-removable vs. Pacemaker With Leads
Time frame: Baseline
Preference weight estimates were used to calculate the predicted probabilities that patients would choose a hypothetical pacemaker profile out of three different pacemaker types- leadless pacemaker non-removable or pacemaker with leads. Attributes for each pacemaker profile were defined using historical or published values. Preference weights from the latent class model were used to compute the probability that respondents within each class preference would choose a pacemaker profile over another.
3 secondary outcomes
Constrained 2-class Latent-class Model Preference Weights
Time frame: Baseline
Number of Discrete Choice Experiment Questions Answered
Time frame: Baseline
Association of Patient Characteristics With Membership in the Transvenous Class Versus the Leadless Class
Time frame: Baseline
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 20 Feb 2025.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Derived from this study: PubMed 39569505Reed SD, Yang JC, Wallace MJ, Sutphin J, Johnson FR, Ozdemir S, Delgado SM, Goates S, Harbert N, Lo M, Rajagopalan B, Ip JE, Al-Khatib SM. Patient Preferences for Features Associated With Leadless Versus Conventional Transvenous Cardiac Pacemakers. Circ Cardiovasc Qual Outcomes. 2024 Dec;17(12):e011168. doi: 10.1161/CIRCOUTCOMES.124.011168. Epub 2024 Nov 21.
- Individual participant dataSharing planned: Undecided
Related trials for Cardiac Rhythm Disorder
RecruitingObservational study
BOdygUardian MOnitoriNg for ReCurrencE of AF
Atrial Fibrillation (AF)
Active, not recruiting
Safety and Efficacy of Conscious Sedation Versus General Anesthesia in Pulsed-Field Ablation for Paroxysmal Atrial Fibrillation
Atrial Fibrillation (Paroxysmal)
Active, not recruitingObservational study
Resumption of Anticoagulation After Major Gastrointestinal Bleeding in Patients With Atrial Fibrillation
Atrial Fibrillation (AF), Gastrointestinal Bleeding
Recruiting
A Comparison of Pulsed Field Ablation (PFA) vs Cryoablation for Atrial Fibrillation Under Deep Sedation
Atrial Fibrillation (AF)
Not yet recruiting
CATCH AF - Atrial Fibrillation Detection in Cryptogenic Stroke
Atrial Fibrillation (AF)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Shelby Reed, PhD principal investigator
Duke Clinical Research Institute
11 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Cardiac Rhythm Disorder and Bradycardia, run by Abbott Medical Devices at 11 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 20 Feb 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 11 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 20 Feb 2025). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Mean Rankings for Pacemaker Device Features (time frame: Baseline). The study lists 9 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT05327101, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Feb 2025.