Safety and Effectiveness of the External Fastening System for Temporary Active Fixation Pacemakers (TEMPACE)

A study testing KronoSafe® System in people with Arrythmia and Bradycardia, run by ICU Medical Technologies S.L. at 2 sites in Spain.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Temporary cardiac pacing with active-fixation leads (TPAFL) using a reusable permanent pacemaker generator has been shown to be safer than lead systems without fixation. However, TPAFL requires the off-label (non-certificated) use of Pacemaker leads and generators. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Arrythmia, Bradycardia
What is being tested?
KronoSafe® System
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
2 sitesSpain
Study dates
5 Jan 2023to 31 Dec 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patient older than 18 years.
  • Need for temporary cardiac stimulation
  • Temporary active fixation pacemaker implantation through left or right jugular access.
  • Signature of informed consent
  • Correct functioning of the electrode after the implantation: sensing of the R wave above 5 millivolts. Ventricular pacing threshold below 1 volt. Electrode impedance between 400-1200 Ohm.
  • Pacemaker programming with stimulation output at 5 volts intensity and 1 millisecond pulse duration.
  • Placement of the KronoSafe® fastening system after electrode implantation.

Who cannot join

  • Complication during the procedure: pneumothorax, hematoma at the puncture site, cardiac perforation, accidental arterial puncture or other that, in the investigator's opinion, poses an added risk of pacemaker dysfunction.
  • Need to transfer the patient to another center with loss of follow-up.
  • Absence of surveillance through continuous electrocardiographic monitoring with detection of arrhythmic events.

Trial locations and contacts

2 sites in 1 country.

Spain2 sites
  • Hospital General Universitario de Alicante Dr.Balmis

    Alicante, 03010

  • Hospital Universitari Vall D'Hebron

    Barcelona, 08035

Other trials in Spain

About this study

Temporary cardiac pacing with active-fixation leads (TPAFL) using a reusable permanent pacemaker generator has been shown to be safer than lead systems without fixation. However, TPAFL requires the off-label (non-certificated) use of Pacemaker leads and generators. It is designed a fastening system to ensure the safety and efficacy of the procedure: the KronoSafe System®. The aim of this study is to demonstrate the safety and effectiveness of the KronoSafe System® for temporary pacing in a series of patients receiving TPAFL.

Being tested
KronoSafe® System
Keywords
Pacemaker, Cardiac pacing, Bradycardia, Arrhythmia, Treatment outcome
Medical subject headings
Arrhythmias, Cardiac, Bradycardia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • KronoSafe® SystemDevice

    All patients included in the study will have a temporary pacemaker with active fixation leads, held by the KronoSafe® fixation system.

Study groups in NCT05351658
Study groupRoleWhat they receive
Temporary Cardiac Pacing with Active-Fixation LeadsExperimentalNot described
Receives: Device: KronoSafe® System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Ventricular R wave detection

    Ventricular R wave, measured in millivolts with pacemaker generator programmer

    Measured: Immediately after the procedure of lead implantation

  2. Lead impedance detection

    Lead impedance, measured in ohms with pacemaker generator programmer

    Measured: Immediately after the procedure of lead implantation

  3. Right ventricle threshold detection

    Right ventricle threshold, measured in volts with pacemaker generator programmer

    Measured: Immediately after the procedure of lead implantation

  4. Ventricular R wave detection

    Ventricular R wave, measured in millivolts with pacemaker generator programmer

    Measured: 24 hours after the procedure of lead implantation

  5. Ventricular R wave detection

    Ventricular R wave, measured in millivolts with pacemaker generator programmer

    Measured: day 3 after the procedure of lead implantation

  6. Ventricular R wave detection

    Ventricular R wave, measured in millivolts with pacemaker generator programmer

    Measured: day 5 after the procedure of lead implantation

  7. Ventricular R wave detection

    Ventricular R wave, measured in millivolts with pacemaker generator programmer

    Measured: day 7 after the procedure of lead implantation

  8. Ventricular R wave detection

    Ventricular R wave, measured in millivolts with pacemaker generator programmer

    Measured: day 9 after the procedure of lead implantation

  9. Ventricular R wave detection

    Ventricular R wave, measured in millivolts with pacemaker generator programmer

    Measured: day 11 after the procedure of lead implantation

  10. Ventricular R wave detection

    Ventricular R wave, measured in millivolts with pacemaker generator programmer

    Measured: day 13 after the procedure of lead implantation

  11. Ventricular R wave detection

    Ventricular R wave, measured in millivolts with pacemaker generator programmer

    Measured: day 15 after the procedure of lead implantation

  12. Ventricular R wave detection

    Ventricular R wave, measured in millivolts with pacemaker generator programmer

    Measured: day 17 after the procedure of lead implantation

  13. Ventricular R wave detection

    Ventricular R wave, measured in millivolts with pacemaker generator programmer

    Measured: day 19 after the procedure of lead implantation

  14. Ventricular R wave detection

    Ventricular R wave, measured in millivolts with pacemaker generator programmer

    Measured: day 21 after the procedure of lead implantation

  15. Ventricular R wave detection

    Ventricular R wave, measured in millivolts with pacemaker generator programmer

    Measured: day 23 after the procedure of lead implantation

  16. Ventricular R wave detection

    Ventricular R wave, measured in millivolts with pacemaker generator programmer

    Measured: day 25 after the procedure of lead implantation

  17. Ventricular R wave detection

    Ventricular R wave, measured in millivolts with pacemaker generator programmer

    Measured: day 27 after the procedure of lead implantation

  18. Ventricular R wave detection

    Ventricular R wave, measured in millivolts with pacemaker generator programmer

    Measured: day 29 after the procedure of lead implantation

  19. Ventricular R wave detection

    Ventricular R wave, measured in millivolts with pacemaker generator programmer

    Measured: Immediately before the procedure of lead removal

  20. Lead impedance detection

    Lead impedance, measured in ohms with pacemaker generator programmer

    Measured: 24 hours after the procedure of lead implantation

  21. Lead impedance detection

    Lead impedance, measured in ohms with pacemaker generator programmer

    Measured: day 3 after the procedure of lead implantation

  22. Lead impedance detection

    Lead impedance, measured in ohms with pacemaker generator programmer

    Measured: day 5 after the procedure of lead implantation

  23. Lead impedance detection

    Lead impedance, measured in ohms with pacemaker generator programmer

    Measured: day 7 after the procedure of lead implantation

  24. Lead impedance detection

    Lead impedance, measured in ohms with pacemaker generator programmer

    Measured: day 9 after the procedure of lead implantation

  25. Lead impedance detection

    Lead impedance, measured in ohms with pacemaker generator programmer

    Measured: day 11 after the procedure of lead implantation

  26. Lead impedance detection

    Lead impedance, measured in ohms with pacemaker generator programmer

    Measured: day 13 after the procedure of lead implantation

  27. Lead impedance detection

    Lead impedance, measured in ohms with pacemaker generator programmer

    Measured: day 15 after the procedure of lead implantation

  28. Lead impedance detection

    Lead impedance, measured in ohms with pacemaker generator programmer

    Measured: day 17 after the procedure of lead implantation

  29. Lead impedance detection

    Lead impedance, measured in ohms with pacemaker generator programmer

    Measured: day 19 after the procedure of lead implantation

  30. Lead impedance detection

    Lead impedance, measured in ohms with pacemaker generator programmer

    Measured: day 21 after the procedure of lead implantation

  31. Lead impedance detection

    Lead impedance, measured in ohms with pacemaker generator programmer

    Measured: day 23 after the procedure of lead implantation

  32. Lead impedance detection

    Lead impedance, measured in ohms with pacemaker generator programmer

    Measured: day 25 after the procedure of lead implantation

  33. Lead impedance detection

    Lead impedance, measured in ohms with pacemaker generator programmer

    Measured: day 27 after the procedure of lead implantation

  34. Lead impedance detection

    Lead impedance, measured in ohms with pacemaker generator programmer

    Measured: day 29 after the procedure of lead implantation

  35. Lead impedance detection

    Lead impedance, measured in ohms with pacemaker generator programmer

    Measured: Immediately before the procedure of lead removal

  36. Right ventricle threshold detection

    Right ventricle threshold, measured in volts with pacemaker generator programmer

    Measured: 24 hours after the procedure of lead implantation

  37. Right ventricle threshold detection

    Right ventricle threshold, measured in volts with pacemaker generator programmer

    Measured: day 3 after the procedure of lead implantation

  38. Right ventricle threshold detection

    Right ventricle threshold, measured in volts with pacemaker generator programmer

    Measured: day 5 after the procedure of lead implantation

  39. Right ventricle threshold detection

    Right ventricle threshold, measured in volts with pacemaker generator programmer

    Measured: day 7 after the procedure of lead implantation

  40. Right ventricle threshold detection

    Right ventricle threshold, measured in volts with pacemaker generator programmer

    Measured: day 9 after the procedure of lead implantation

  41. Right ventricle threshold detection

    Right ventricle threshold, measured in volts with pacemaker generator programmer

    Measured: day 11 after the procedure of lead implantation

  42. Right ventricle threshold detection

    Right ventricle threshold, measured in volts with pacemaker generator programmer

    Measured: day 13 after the procedure of lead implantation

  43. Right ventricle threshold detection

    Right ventricle threshold, measured in volts with pacemaker generator programmer

    Measured: day 15 after the procedure of lead implantation

  44. Right ventricle threshold detection

    Right ventricle threshold, measured in volts with pacemaker generator programmer

    Measured: day 17 after the procedure of lead implantation

  45. Right ventricle threshold detection

    Right ventricle threshold, measured in volts with pacemaker generator programmer

    Measured: day 19 after the procedure of lead implantation

  46. Right ventricle threshold detection

    Right ventricle threshold, measured in volts with pacemaker generator programmer

    Measured: day 21 after the procedure of lead implantation

  47. Right ventricle threshold detection

    Right ventricle threshold, measured in volts with pacemaker generator programmer

    Measured: day 23 after the procedure of lead implantation

  48. Right ventricle threshold detection

    Right ventricle threshold, measured in volts with pacemaker generator programmer

    Measured: day 25 after the procedure of lead implantation

  49. Right ventricle threshold detection

    Right ventricle threshold, measured in volts with pacemaker generator programmer

    Measured: day 27 after the procedure of lead implantation

  50. Right ventricle threshold detection

    Right ventricle threshold, measured in volts with pacemaker generator programmer

    Measured: day 29 after the procedure of lead implantation

  51. Right ventricle threshold detection

    Right ventricle threshold, measured in volts with pacemaker generator programmer

    Measured: Immediately before the procedure of lead removal

  52. Lead displacement detection

    Visual observation of 2 cm electrode displacement through vein acces by clinical examination

    Measured: Immediately before the procedure of lead removal

  53. Capture failure detection

    Right ventricle threshold above 5 volts during 1 millisecond, measured with pacemaker generator programmer.

    Measured: Immediately before the procedure of lead removal

  54. Sensing failure detection

    Ventricular R wave below 1 volt, measured with pacemaker generator programmer

    Measured: Immediately before the procedure of lead removal

  55. Lead insulation breakdown detection

    Visual observation of lead insulation breakdown by clinical examination

    Measured: Immediately before the procedure of lead removal

  56. Generator detachment detection

    Visual observation of generator detachment by clinical examination. removal of the generator from the casing.

    Measured: Immediately before the procedure of lead removal

  57. Cardiac peroration detection

    New pericardial effusion detected by Echocardiography with signs of cardiac tamponade: respiratory variation of transmitral filling flow greater than 25%

    Measured: Immediately before the procedure of lead removal

Secondary outcomes (2)
  1. Detection of Bacteremia

    Isolation of the same bacteria in the pacemaker lead and 2 blood cultures from the patient

    Measured: Immediately after the procedure of lead removal

  2. Detection of Agitation

    Record of antipsychotic and anxiolytic treatment of the patient

    Measured: Immediately after the procedure of lead removal

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted28 Apr 2022
  2. Study start5 Jan 2023
  3. Primary completion18 Nov 2024
  4. Study completion31 Dec 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Supportive care
Allocation
Not applicable
Intervention model
Single group
Model description
The study will be carried out in an Arrhythmia Unit or Intensive Care Unit. Patients who need urgent temporary cardiac pacing due to bradycardia, or elective pacing to prevent heart rhythm disturbances during high-risk arrhythmia interventions, such as transcatheter aortic valve implantation (TAVR), alcoholic septal ablations, etc., will be included. After the temporary pacemaker implantation with active fixation electrode in a correct way, the KronoSafe® external pacemaker fixation system will be placed. The correct functioning of the system (R wave detection, lead impedance and right ventricle threshold) will be checked at 24 hours and every other day until the end of cardiac stimulation. During temporary pacing, associated complications are going to be recorded: lead displacement, capture or sensing failure, generator or lead detachment, and cardiac perforation.
Masking
None (open label)
Enrolment
30 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05351658
Sponsor's protocol ID
TEMPACE
Acronym
TEMPACE
Status last verified
Apr 2025
First submitted
28 Mar 2022
Last updated
20 Apr 2025
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Vicente-Miralles R, Martin-Langerwerf DA, Nunez-Martinez JM, Marco-Juan A, Sangio-Ferreyros AD, Davila-Arias A, Montes-Jacobo L, Barrios V, Palazon-Bru A, Gil-Guillen VF, Bertomeu-Gonzalez V. A new fastening system for temporary pacing with active-fixation leads: effectiveness and safety. Eur Heart J Acute Cardiovasc Care. 2022 Mar 16;11(3):224-229. doi: 10.1093/ehjacc/zuab119.

    PubMed 34918044
  • Zei PC, Eckart RE, Epstein LM. Modified temporary cardiac pacing using transvenous active fixation leads and external re-sterilized pulse generators. J Am Coll Cardiol. 2006 Apr 4;47(7):1487-9. doi: 10.1016/j.jacc.2006.01.006. Epub 2006 Mar 15. No abstract available.

    PubMed 16580542
  • Kawata H, Pretorius V, Phan H, Mulpuru S, Gadiyaram V, Patel J, Steltzner D, Krummen D, Feld G, Birgersdotter-Green U. Utility and safety of temporary pacing using active fixation leads and externalized re-usable permanent pacemakers after lead extraction. Europace. 2013 Sep;15(9):1287-91. doi: 10.1093/europace/eut045. Epub 2013 Mar 12.

    PubMed 23482613
  • Betts TR. Regional survey of temporary transvenous pacing procedures and complications. Postgrad Med J. 2003 Aug;79(934):463-5. doi: 10.1136/pmj.79.934.463.

    PubMed 12954959
  • Vicente-Miralles R, Rivas-Gandara N, Jordan Marchite P, Adelino R, Carmona MA, Diaz Barranco M, Ibanez Criado AA, Ruiz Nodar JM, Ajo Ferrer M, Garcia-Fernandez A, Bertomeu-Gonzalez V, Martinez Martinez JG. A novel device for temporary cardiac stimulation using permanent pacemaker generators and active-fixation leads: the TEMPACE multicentre prospective study. Eur Heart J Acute Cardiovasc Care. 2026 Jan 23;14(12):732-738. doi: 10.1093/ehjacc/zuaf111.

    PubMed 40875828

Questions about this trial

What is this clinical trial studying?

A study testing KronoSafe® System in people with Arrythmia and Bradycardia, run by ICU Medical Technologies S.L. at 2 sites in Spain.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 7 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 20 Apr 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in Spain. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Ventricular R wave detection (time frame: Immediately after the procedure of lead implantation). The study lists 57 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05351658, which also lists 5 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Apr 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in