AzTrials
AzTrials

Dental ImplantNCT05361226

The Accuracy of s-CAIS Compared With c-LIS

A study testing Accuracy measurement in people with Dental Implant, run by Mahidol University at 1 site in Thailand.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

To compare the static computer-aided implant surgery (s-CAIS) and conventional laboratory-guided implant surgery (c-LIS) in terms of accuracy for single tooth replacement in posterior areas. Read more about this study

Who is it for?
Ages 25 years and olderHealthy volunteers can take part
Conditions the study is for
Dental Implant
What is being tested?
Accuracy measurement
Could I receive a placebo?
No, everyone receives an active treatment
How many people
40 participants
Where
1 siteThailand
Study dates
9 Jul 2019to 30 Oct 2020
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 25 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Patients had a partially edentulous ridge in the premolar-molar region with existing two-sided interproximal as well as antagonistic contacts
  • Patients had healthy periodontal status and adequate keratinized gingiva at the edentulous space

Who cannot join

  • - Patients have any local and systemic diseases considered as contraindications for dental implant treatment.

Trial locations and contacts

1 site in 1 country.

Thailand1 site
  • Faculty of Dentistry, Mahidol University

    Ratchathewi, Bangkok, 10400

Other trials in Thailand

About this study

Official title: The Accuracy of Static Computer-aided Implant Surgery Compared With Conventional Laboratory-guided Implant Surgery for Single-tooth Replacement: A Randomized Controlled Trial

To compare the static computer-aided implant surgery (s-CAIS) and conventional laboratory-guided implant surgery (c-LIS) in terms of accuracy for single tooth replacement in posterior areas.

Read the detailed description

There was still a lack of evidence in randomized clinical studies about the accuracy measurement comparing digital and laboratory workflows with tooth-supported templates for single implant cases in the posterior regions. Therefore, this present study's primary investigation was to perform accuracy measurement comparing digital and laboratory workflows with tooth-supported templates for single implant cases in the posterior regions. The secondary investigation was to find the effect of several factors on the accuracy of implant placement in these areas.

Conditions
Dental Implant
Being tested
Accuracy measurement
Keywords
Clinical Research, static computer aided implant surgery, accuracy, Dental implant

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Accuracy measurementOther

    Three months following the implant placement, patients were called back to the implant clinic to record the actual implant position with the digital impression technique. Full mouth scans were done by using the intraoral scanner (Trios 3, 3Shape, Copenhagen, Denmark). The surface scans were then exported as an STL file and were imported to coDiagnostiX software. The "Treatment evaluation tool" function tool was used to measure the accuracy of the implant placement which measured the amount of deviation of the placed implant from the planned position. The outcomes were generated into three main parameters.

Study groups in NCT05361226
Study groupRoleWhat they receive
s-CAIS (static computer aided implant surgery)ExperimentalFor the s-CAIS group, Cone Beam Computed Tomography (CBCT) and full-arch optical scan were performed to provide digital information for implant planning software (coDiagnostix 9, Dental Wings GmbH, Chemnitz, Germany). The virtual implant was set on a three dimensional (3D) virtual jaws according to the prosthetically driven protocol by one postgraduate dentist and was confirmed by one experienced dentist. Static surgical template covering on occlusal part of 4 teeth anteroposteriorly was then fabricated via 3D printing machine (surgical guide resin, Form 2, Formlabs, Somerville, Massachusetts, USA). This surgical template would be used during surgery.
Receives: Other: Accuracy measurement
c-LIS (conventional laboratory-guided implant surgery)Active comparatorFor the c-LIS group, a radiographic template (ORTHO Plast, prominent®, Chonburi, Thailand) was fabricated covering on occlusal part of 4 teeth anteroposteriorly according to diagnostic wax-up on the study model. A radiographic marker (gutta percha) was then filled in the created hole of the template and for used while taking CBCT image to verify marker position. Next, a study model was scanned by laboratory surface scan (D900m, 3Shape, Copenhagen, Denmark). The STL file was imported to 3D printing devices and the resin model was fabricated (Dental LT clear resin, Form 2, Formlabs, Somerville, Massachusetts, USA). Next, the same template that had been used for CBCT was used to place implant replicas in a resin model. The position of the implant replicas in the models were assumed as pre-operative planned implant position.
Receives: Other: Accuracy measurement

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The accuracy of implant placement

    Patients were called back to record the actual implant position with the the intraoral scanner (Trios 3, 3Shape, Copenhagen, Denmark). The surface scans were then exported as an STL file and were imported to coDiagnostiX software. Those postoperative surface scans were merged with the preoperative surface scan in each group protocols. The "Treatment evaluation tool" function tool was used to measure the accuracy of the implant placement which measured the amount of deviation of the placed implant from the planned position. The outcomes were generated into three main parameters which were Angular deviation, Coronal global deviation and Apical global deviation.

    Angular deviation = the amount of angle(°), in which the actually placed implant deviated from the virtually planned implant in 3D.

    Coronal/ Apical global deviation = the amount of distance(mm), in which the actually placed implant deviated from the virtually planned implant at the coronal/ apical position in 3D.

    Measured: Three months after implant placement

Secondary outcomes (1)
  1. Factors influencing the accuracy of implant placement

    Various factors influencing the accuracy of implant placement were also analyzed including the type of arch (Maxilla vs. Mandible), side of the arch (Left vs. Right), implant location (Premolar vs. Molar), implant diameter (WN vs. RN), implant length (8 vs. 10 mm), ridge morphology (Broad (≥8mm) vs. Narrow (˂8mm), cortical bone thickness and cortical interference. The thickness of the cortical bone was evaluated at the center of the implant after the planned implant position was completely set in the coDiagnostiX program. If any parts of the planned implant involving against any cortical bone walls, it would count as having a cortical interference.

    Measured: Three months after implant placement

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 May 2022
  2. Study start9 Jul 2019
  3. Primary completion30 Jul 2020
  4. Study completion30 Oct 2020

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Forty participants were allocated to two study groups via the coin-tossing technique.
Masking
Double blind
Who is masked
Investigator, Outcomes assessor
Enrolment
40 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05361226
Sponsor's protocol ID
2019/DT071-1
Status last verified
Apr 2022
First submitted
10 Apr 2022
Last updated
4 May 2022
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Jung RE, Schneider D, Ganeles J, Wismeijer D, Zwahlen M, Hammerle CH, Tahmaseb A. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants. 2009;24 Suppl:92-109.

    PubMed 19885437
  • D'haese J, Ackhurst J, Wismeijer D, De Bruyn H, Tahmaseb A. Current state of the art of computer-guided implant surgery. Periodontol 2000. 2017 Feb;73(1):121-133. doi: 10.1111/prd.12175.

    PubMed 28000275
  • Hultin M, Svensson KG, Trulsson M. Clinical advantages of computer-guided implant placement: a systematic review. Clin Oral Implants Res. 2012 Oct;23 Suppl 6:124-35. doi: 10.1111/j.1600-0501.2012.02545.x.

    PubMed 23062137
  • Younes F, Eghbali A, De Bruyckere T, Cleymaet R, Cosyn J. A randomized controlled trial on the efficiency of free-handed, pilot-drill guided and fully guided implant surgery in partially edentulous patients. Clin Oral Implants Res. 2019 Feb;30(2):131-138. doi: 10.1111/clr.13399. Epub 2019 Jan 7.

    PubMed 30578650
  • Behneke A, Burwinkel M, Behneke N. Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement. Clin Oral Implants Res. 2012 Apr;23(4):416-23. doi: 10.1111/j.1600-0501.2011.02337.x. Epub 2011 Oct 24.

    PubMed 22092586
  • Cassetta M, Stefanelli LV, Giansanti M, Calasso S. Accuracy of implant placement with a stereolithographic surgical template. Int J Oral Maxillofac Implants. 2012 May-Jun;27(3):655-63.

    PubMed 22616060
  • Zhao XZ, Xu WH, Tang ZH, Wu MJ, Zhu J, Chen S. Accuracy of computer-guided implant surgery by a CAD/CAM and laser scanning technique. Chin J Dent Res. 2014;17(1):31-6.

    PubMed 25028687
  • Tahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C. The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis. Clin Oral Implants Res. 2018 Oct;29 Suppl 16:416-435. doi: 10.1111/clr.13346.

    PubMed 30328191
  • Gallardo YNR, da Silva-Olivio IR, Gonzaga L, Sesma N, Martin W. A Systematic Review of Clinical Outcomes on Patients Rehabilitated with Complete-Arch Fixed Implant-Supported Prostheses According to the Time of Loading. J Prosthodont. 2019 Dec;28(9):958-968. doi: 10.1111/jopr.13104. Epub 2019 Oct 18.

    PubMed 31433096
  • Geng W, Liu C, Su Y, Li J, Zhou Y. Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement. Int J Clin Exp Med. 2015 Jun 15;8(6):8442-9. eCollection 2015.

    PubMed 26309497
  • Pozzi A, Polizzi G, Moy PK. Guided surgery with tooth-supported templates for single missing teeth: A critical review. Eur J Oral Implantol. 2016;9 Suppl 1:S135-53.

    PubMed 27314119
  • Tahmaseb A, Wismeijer D, Coucke W, Derksen W. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants. 2014;29 Suppl:25-42. doi: 10.11607/jomi.2014suppl.g1.2.

    PubMed 24660188
  • Di Giacomo GA, Cury PR, de Araujo NS, Sendyk WR, Sendyk CL. Clinical application of stereolithographic surgical guides for implant placement: preliminary results. J Periodontol. 2005 Apr;76(4):503-7. doi: 10.1902/jop.2005.76.4.503.

    PubMed 15857088
  • Ersoy AE, Turkyilmaz I, Ozan O, McGlumphy EA. Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants. J Periodontol. 2008 Aug;79(8):1339-45. doi: 10.1902/jop.2008.080059.

    PubMed 18672982
  • Choi W, Nguyen BC, Doan A, Girod S, Gaudilliere B, Gaudilliere D. Freehand Versus Guided Surgery: Factors Influencing Accuracy of Dental Implant Placement. Implant Dent. 2017 Aug;26(4):500-509. doi: 10.1097/ID.0000000000000620.

    PubMed 28731896

Questions about this trial

What is this clinical trial studying?

A study testing Accuracy measurement in people with Dental Implant, run by Mahidol University at 1 site in Thailand.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 4 May 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Thailand. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The accuracy of implant placement (time frame: Three months after implant placement). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05361226, which also lists 38 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 May 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in