This early-stage study is designed to determine the efficacy of the CE-approved, antibacterial, dual-light Lumoral method in periodontitis patients. Improved supragingival plaque control can help to also sustain the subgingival plaque management in the long term. Read more about this study
- Who is it for?
- Ages 18 to 85 years
- Conditions the study is for
- Periodontitis, Plaque, Dental, Plaque Induced Gingivitis
- What is being tested?
- Lumoral device
- Type of treatment
- Pill or oral medicine, Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 40 participants
- Where
- 1 siteFinland
- Study dates
- 11 Oct 2022to 16 Aug 2023
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 85 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- At least 18 years old
- Agreement to participate in the study and to sign a written consent form
Who cannot join
- Presence of any physical limitation or restriction that might restrict Lumoral use
- Pregnancy or lactation
Trial locations and contacts
1 site in 1 country.
Finland1 site
Wellbeing services County Pirkanmaa, Health Services, Orthodontics and specialized dental care
Tampere, Pirkanmaa, 33520
About this study
This early-stage study is designed to determine the efficacy of the CE-approved, antibacterial, dual-light Lumoral method in periodontitis patients. Improved supragingival plaque control can help to also sustain the subgingival plaque management in the long term. In addition, the device might have a photobiomodulation effect on periodontal tissues.
Read the detailed description
Dental plaque triggers changes in gingival health, which results in slight swelling and bleeding from the gingival margin and causes gingivitis. Supragingival dental biofilm control can be achieved by mechanical and chemical means. Toothbrushing is effective in reducing levels of dental plaque (van der Weijden \& Slot 2015). It removes plaque from flat, accessible surfaces but is less effective at the gingival margins and in approximal areas, where the accumulation of residual plaque encourages gingivitis and deterioration of periodontal health. Effective toothbrushing is also depending on a number of factors, e.g., age, knowledge, manual dexterity and motivation. Oral hygiene instructions and patient motivation in oral hygiene practices should be an integral part of the patient management during all stages of periodontal treatment (Tonetti et al., 2015). Oral health practice of individuals affects their gingival and periodontal health.
The Lumoral is a CE-marked medical device developed to provide a potent, targeted antibacterial action on dental plaque in a home environment. The device mechanism of action is antibacterial photodynamic therapy. The device is used by swishing a mouth rinse, which has a strong adherence to dental plaque. The plaque-adhered photoactive mouth rinse can be activated by a simple to use light applicator. Preliminary results have shown a promising anti-inflammatory response in addition to plaque reduction.
This early-stage study is designed to determine the efficacy of the Lumoral method in periodontitis patients. Improved supragingival plaque control can help to also sustain the subgingival plaque management in the long term. In addition, the device might have a photobiomodulation effect on periodontal tissues.
Forty (40) patients are randomized to the Lumoral treatment group or the control group. Both groups shall receive standard oral hygiene instructions for sonic toothbrush, interdental brush, and dental floss use. All the patients shall be assessed for the clinical periodontal status including visible plaque index (VPI), bleeding on probing (BOP) and probing pocket depth (PPD). In addition, aMMP-8 mouth rinse test and microbiological analysis of gingival pockets will be performed. Digital photographs after staining will be taken. These analyses shall be performed at baseline and at 4 weeks after the treatment.
- Conditions
- Periodontitis, Plaque, Dental, Plaque Induced Gingivitis
- Being tested
- Lumoral device
- Keywords
- Lumoral, Lumorinse, Plaque, Periodontitis, Plaque control
- Medical subject headings
- Periodontitis, Dental Plaque, Plaque, Amyloid
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Lumoral deviceDevice
Also called Lumorinse mouth rinse
The Lumoral treatment -device is a CE-marked antibacterial home-use device for the treatment and prevention of oral diseases caused by bacteria. It is used in combination with a CE-marked mouth rinse called Lumorinse.
| Study group | Role | What they receive |
|---|---|---|
| Study group | Experimental | Subjects in the study group will use the Lumoral device once a day according to the verbal and written instructions provided to them. In addition, they will brush their teeth twice daily in their customary manner while using the provided sonic toothbrush and regular toothpaste. Receives: Device: Lumoral device |
| Control group | Active comparator | Subjects in the control group will brush their teeth in their customary manner twice daily while using the provided sonic toothbrush and regular toothpaste. They will not receive any additional intervention. Receives: Device: Lumoral device |
What is being measured
The primary outcome is the main question the study is designed to answer.
BoP
Reduction in bleeding on probing (BoP).
Procedure for BoP:
- A full-mouth assessment at six sites per tooth
- Gingival bleeding is considered as positive if bleeding occurs within 15 seconds after gentle probing with a probe at the sulcus
- Dichotomous scoring to each site of the tooth as bleeding "1 present" and "0 absent"
- BOP reported as the percentage (%) of sites with positive findings
- Calculation formula: number of bleeding sites/ 6 times number of teeth
Measured: 4 weeks
Secondary outcomes (4)
Microbiological pathogens
Change in periodontal microbiological pathogens. The plaque sample will be taken from the teeth with ≥3 mm pockets with a sterile paper point. If the subject does not have any deep periodontal pockets, then a sample will be taken from shallow sites. Prior to sampling, the supragingival plaque will be removed with a curette. The paper point will be then taken to the gingival pocket with sterile tweezers. The paper pin will be allowed to stand for 10 to 20 seconds, after which it will be removed and sealed in an empty plastic sample transport tube.
A gene amplification method (polymerase chain reaction, PCR) will be used to look for six key bacteria in periodontitis: Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Treponema denticola, Tannerella forsythia, Prevotella intermedia and Parvimonas micra.
Measured: 4 weeks
aMMP-8
Reduction in periodontal inflammation marker aMMP-8. An aMMP-8 marker analysis will be performed using Periosafe test (Dentognostics GmbH) according to the manufacturer's instructions.
Measured: 4 weeks
VPI
Clinical improvement concerning visible plaque index (VPI).
Procedure for VPI:
- A full-mouth assessment, measured at 4 sites per tooth
- Dichotomous scoring to each site of the tooth as plaque "1 present" and "0 absent"
- VPI reported as the percentage (%) of sites with plaque
- Calculation formula: number of sites with plaque/ 4 times number of teeth
Measured: 4 weeks
PPD
Reduction in probing pocket depth (PPD).
Procedure for PPD:
- A full-mouth assessment, measured at six sites per tooth
- Assessed from the base of the pocket to the gingival margin (mm).
Measured: 4 weeks
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted4 May 2022
- Study start11 Oct 2022
- Primary completion16 Aug 2023
- Study completion16 Aug 2023
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for PeriodontitisStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Supportive care
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Model description
- 20 participants in the treatment (Lumoral) group and 20 participants in the control group.
- Masking
- Triple blind
- Who is masked
- Participant, Investigator, Outcomes assessor
- Enrolment
- 40 participants (actual)
Sponsor and investigators
- Lead sponsor
- Koite Health Oy
- Sponsor type
- Industry (pharma, biotech, devices)
- Collaborators
- Tampere University, University of Helsinki
- Responsible party
- Sponsor
- Investigators
- Tommi Pätilä, Docent, Study director, Head of Research
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05361590
- Sponsor's protocol ID
- DPS-01
- Status last verified
- Sep 2023
- First submitted
- 29 Apr 2022
- Last updated
- 21 Sep 2023
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No: The IPD will only be administered by the researchers that are listed in the CIP.
Study at a glance
From the registry record, last updated by the sponsor on 21 Sep 2023. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Impact of Regular Home Use of Lumoral Dual-light Photodynamic Therapy on Plaque Control and Gingival Health
- ClinicalTrials.gov ID
- NCT05361590
- Acronym / sponsor ID
- DPS-01
- Conditions
- Periodontitis, Plaque, Dental, Plaque Induced Gingivitis
- Keywords
- Lumoral, Lumorinse, Plaque, Periodontitis, Plaque control
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 40 participants (actual)
- Lead sponsor
- Koite Health OyIndustry (pharma, biotech, devices)
- Collaborators
- Tampere University, University of Helsinki
- Study start
- 11 Oct 2022 (actual)
- Primary completion
- 16 Aug 2023 (actual)
- Study completion
- 16 Aug 2023 (actual)
- First posted
- 4 May 2022 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This early-stage study is designed to determine the efficacy of the CE-approved, antibacterial, dual-light Lumoral method in periodontitis patients. Improved supragingival plaque control can help to also sustain the subgingival plaque management in the long term. In addition, the device might have a photobiomodulation effect on periodontal tissues.
Detailed description
Dental plaque triggers changes in gingival health, which results in slight swelling and bleeding from the gingival margin and causes gingivitis. Supragingival dental biofilm control can be achieved by mechanical and chemical means. Toothbrushing is effective in reducing levels of dental plaque (van der Weijden \& Slot 2015). It removes plaque from flat, accessible surfaces but is less effective at the gingival margins and in approximal areas, where the accumulation of residual plaque encourages gingivitis and deterioration of periodontal health. Effective toothbrushing is also depending on a number of factors, e.g., age, knowledge, manual dexterity and motivation. Oral hygiene instructions and patient motivation in oral hygiene practices should be an integral part of the patient management during all stages of periodontal treatment (Tonetti et al., 2015). Oral health practice of individuals affects their gingival and periodontal health.
The Lumoral is a CE-marked medical device developed to provide a potent, targeted antibacterial action on dental plaque in a home environment. The device mechanism of action is antibacterial photodynamic therapy. The device is used by swishing a mouth rinse, which has a strong adherence to dental plaque. The plaque-adhered photoactive mouth rinse can be activated by a simple to use light applicator. Preliminary results have shown a promising anti-inflammatory response in addition to plaque reduction.
This early-stage study is designed to determine the efficacy of the Lumoral method in periodontitis patients. Improved supragingival plaque control can help to also sustain the subgingival plaque management in the long term. In addition, the device might have a photobiomodulation effect on periodontal tissues.
Forty (40) patients are randomized to the Lumoral treatment group or the control group. Both groups shall receive standard oral hygiene instructions for sonic toothbrush, interdental brush, and dental floss use. All the patients shall be assessed for the clinical periodontal status including visible plaque index (VPI), bleeding on probing (BOP) and probing pocket depth (PPD). In addition, aMMP-8 mouth rinse test and microbiological analysis of gingival pockets will be performed. Digital photographs after staining will be taken. These analyses shall be performed at baseline and at 4 weeks after the treatment.
Study design
- Primary purpose
- Supportive care
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Triple blind (participant, investigator, outcomes assessor)
- Number of arms
- 2
- Model description
- 20 participants in the treatment (Lumoral) group and 20 participants in the control group.
| Arm | Type | Receives |
|---|---|---|
| Study group | Experimental | Device: Lumoral deviceSubjects in the study group will use the Lumoral device once a day according to the verbal and written instructions provided to them. In addition, they will brush their teeth twice daily in their customary manner while using the provided sonic toothbrush and regular toothpaste. |
| Control group | Active comparator | Device: Lumoral deviceSubjects in the control group will brush their teeth in their customary manner twice daily while using the provided sonic toothbrush and regular toothpaste. They will not receive any additional intervention. |
Who may qualify
- Ages
- 18 to 85 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (2 listed)
- At least 18 years old
- Agreement to participate in the study and to sign a written consent form
Key exclusion criteria (2 listed)
- Presence of any physical limitation or restriction that might restrict Lumoral use
- Pregnancy or lactation
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Lumoral deviceAlso: Lumorinse mouth rinseThe Lumoral treatment -device is a CE-marked antibacterial home-use device for the treatment and prevention of oral diseases caused by bacteria. It is used in combination with a CE-marked mouth rinse called Lumorinse. | Device | Control group, Study group |
Primary outcome
BoP
Time frame: 4 weeks
Reduction in bleeding on probing (BoP). Procedure for BoP: * A full-mouth assessment at six sites per tooth * Gingival bleeding is considered as positive if bleeding occurs within 15 seconds after gentle probing with a probe at the sulcus * Dichotomous scoring to each site of the tooth as bleeding "1 present" and "0 absent" * BOP reported as the percentage (%) of sites with positive findings * Calculation formula: number of bleeding sites/ 6 times number of teeth
4 secondary outcomes
Microbiological pathogens
Time frame: 4 weeks
aMMP-8
Time frame: 4 weeks
VPI
Time frame: 4 weeks
PPD
Time frame: 4 weeks
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 21 Sep 2023.
- Alaijah, F., Morsi, A., Nasher, R. et al. Photobiomodulation therapy in the treatment of periodontal disease: a literature review. Laser Dent Sci 3, 147-153 (2019Link provided by the sponsor.
- Levine JI. Medications that increase photosensititivity. FDA document Dec 1990.Link provided by the sponsor.
- Nikinmaa S, Alapulli H, Auvinen P, et al. (2020) Dual-light photodynamic therapy administered daily provides a sustained antibacterial effect on biofilm and prevents Streptococcus mutans adaptation. PLoS ONE 15(5): e0232775.Link provided by the sponsor.
- Lähteenmäki H, Pätilä T, Räisänen IT, et al. (2022). Repeated Home-Applied Dual-Light Antibacterial Photodynamic Therapy Can Reduce Plaque Burden, Inflammation, and aMMP-8 in Peri-Implant Disease - A Pilot StudyLink provided by the sponsor.
- Pereira PAB, Aho VTE, Paulin L, et al., (2017) Oral and nasal microbiota in Parkinson's disease. Parkinsonism and Related Disorders 38: 61-67.Link provided by the sponsor.
- Sanz M, Herrera D, Kebschull M, et al.; On behalf of the EFP Workshop Participants and Methodological Consultants. (2020) Treatment of stage I-III periodontitis-The EFP S3 level clinical practice guideline. J Clin Periodontol., 47: 4- 60.Link provided by the sponsor.
- Individual participant dataSharing planned: No. The IPD will only be administered by the researchers that are listed in the CIP.
Related trials for Periodontitis
Recruiting
Effect of Cryotherapeutic and Nanotherapeutic Sodium Hypochlorite on Post-Operative Endodontic Pain.
Symptomatic Irreversible Pulpitis, Symptomatic Apical Periodontitis
Active, not recruitingObservational study
A Retrospective Comparative Evaluation of Omega-3 and Resveratrol Supplementation in Patients With Periodontitis
Periodontitis
Recruiting
Probiotics Versus Antibiotics as an Adjuvant to Non-surgical Periodontal Treatment Among Smokers With Stage II, Grade B Periodontitis
Probiotics, Antibiotics
Recruiting
Effects of Different Activation Techniques on Antimicrobial Photodynamic Therapy in Apical Periodontitis
Apical Periodontitis, Endodontic Retreatment
Recruiting
Ozone Gel Versus Chlorohexidine Gel as an Adjunct to Non-Surgical Treatment of Stage II Periodontitis Grade B Among Smokers Patients
Ozone Gel, Chlorohexidine Gel
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Tommi Pätilä, Docent study director
Head of Research
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Lumoral device in people with Periodontitis and Plaque, Dental, run by Koite Health Oy at 1 site in Finland.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 21 Sep 2023. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Finland. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
BoP (time frame: 4 weeks). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 21 Sep 2023.