AzTrials
AzTrials

ShockNCT05428423

Reliability of PVI Changes During Tidal Volume Challenge in ICU Patients

An observational study of Shock and Septic Shock, run by Bicetre Hospital at 1 site in France.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The aim of this study is to assess whether changes in the plethysmography variability index, during a tidal volume challenge, can reliably detect simultaneous changes in arterial blood pressure pulsatility, in patients hospitalized in intensive care unit. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Shock, Septic Shock, Sepsis
How many people
44 participants
Where
1 siteFrance
Study dates
6 Jun 2022to Nov 2022
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Patients hospitalized in intensive care unit, mechanically ventilated with a tidal volume of 6 ml/kg on ideal body weight, with oxygen saturation monitoring with Masimo SET and cardiac output monitoring with PICCO2 system in place.

Who may be able to join

  • patients hospitalized in intensive care unit
  • physicians' decision to perform a tidal volume challenge
  • hemodynamic monitoring with a calibrated pulse contour analysis device (PICCO2) in place
  • monitoring of oxygen saturation with Masimo SET
  • mechanical ventilation with tidal volume of 6 ml/kg on ideal body weight

Who cannot join

  • thoracic drainage
  • patient under judicial protection

Trial locations and contacts

1 site in 1 country.

Xavier Monnet, MD-PhD contact

+33 06 60 86 26 69

xavier.monnet@aphp.fr

France1 site, 1 recruiting
  • Service de médecine intensive-réanimation, Hôpital de Bicêtre

    Le Kremlin-Bicêtre, 94270

    Xavier Monnet, MD-PhD, +33 06 60 86 26 69, xavier.monnet@aphp.fr

    Recruiting

Other trials in France

About this study

Official title: Assessment of the Reliability of Changes in Plethysmography Variability Index During Tidal Volume Challenge for Predicting Fluid Responsiveness in Intensive Care Unit Patients

The aim of this study is to assess whether changes in the plethysmography variability index, during a tidal volume challenge, can reliably detect simultaneous changes in arterial blood pressure pulsatility, in patients hospitalized in intensive care unit. If results will be positive, this will allow the test to be performed even in the absence of an invasive arterial catheter.

Read the detailed description

Among patients in a state of shock one of the first treatments is volume expansion, consisting in a fast intravenous injection of crystalloid or colloid solutions in order to increase cardiac preload and consequently cardiac output. However, this augmentation of the cardiac output happens only in half of the patients.To avoid ineffective fluid administration several tests have been developed.

One of these tests is called the "tidal volume challenge" (TVC). It consists of transiently increasing for 1 minute the volume of air inhaled with each breath, in mechanically ventilated patients, and then evaluating whether this change impacts the pulsatility of the arterial blood pressure, detected by an arterial catheter. This test seems reliable, but it requires an arterial catheter to be in place.

It has been suggested in previous studies that pulsatility of blood pressure can be estimated by the pulsatility of the plethysmography signal ("plethysmography variability index"), obtained from the oxygen saturation signal that's measured in all intensive care patients. The advantage is that this measurement only requires a sensor placed at the end of a finger, on the earlobe or on the forehead.

The aim of the study is to assess whether changes in the plethysmography variability index (PVI) during a TVC can reliably detect simultaneous changes in blood pressure pulsatility. This study will include patients hospitalized in intensive care unit, mechanically ventilated, in whom physicians have decided to perform a TVC as common practice. Changes, occurred during this test, in arterial blood pressure pulsatility and in plethysmography pulsatility index will be measured and compared. If results will show that changes in PVI during TVC are reliable for measuring blood pressure pulsatility changes during this test, this will allow the test to be used even in the absence of an arterial catheter.

Keywords
Tidal volume challenge, Pleth variability index
Medical subject headings
Shock, Shock, Septic, Sepsis

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Reliability of PVI changes in diagnosing preload responsiveness during TVC

    The primary objective is to assess the reliability of PVI changes induced by a tidal volume challenge test in diagnosing a preload responsiveness state in adult ICU patients.

    Measured: TVC is performed in 1 minute

Secondary outcomes (3)
  1. Reliability of PVI absolute values to diagnose preload responsiveness

    Secondary objective is to test the reliability of absolute values of PVI to diagnose a preload responsiveness state in adult intensive care patients.

    Measured: TVC is performed in 1 minute

  2. Evaluation of PVI changes during TVC according to sensor position

    Third objective is to compare the value of changes in PVI induced by a tidal volume challenge test to diagnose a preload responsiveness state according to the location of the plethysmographic measurement (finger, earlobe, forehead).

    Measured: TVC is performed in 1 minute

  3. Comparison of PPV and PVI changes during PLR test or volume expansion

    Forth objective is to compare the changes in pulse pressure variation (PPV) and PVI during a passive leg raising test (PLR) and a volume expansion, if applicable.

    Measured: PLR is performed in 1 minute

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted23 Jun 2022
  2. Study start6 Jun 2022
  3. Primary completionNov 2022 (estimated)
  4. Study completionNov 2022 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
44 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05428423
Sponsor's protocol ID
IDRCB:2022-A01253-40
Status last verified
Nov 2022
First submitted
17 Jun 2022
Last updated
23 Nov 2022
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Publications

  • Marik PE, Monnet X, Teboul JL. Hemodynamic parameters to guide fluid therapy. Ann Intensive Care. 2011 Mar 21;1(1):1. doi: 10.1186/2110-5820-1-1.

    PubMed 21906322
  • National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network; Wiedemann HP, Wheeler AP, Bernard GR, Thompson BT, Hayden D, deBoisblanc B, Connors AF Jr, Hite RD, Harabin AL. Comparison of two fluid-management strategies in acute lung injury. N Engl J Med. 2006 Jun 15;354(24):2564-75. doi: 10.1056/NEJMoa062200. Epub 2006 May 21.

    PubMed 16714767
  • Myatra SN, Prabu NR, Divatia JV, Monnet X, Kulkarni AP, Teboul JL. The Changes in Pulse Pressure Variation or Stroke Volume Variation After a "Tidal Volume Challenge" Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation. Crit Care Med. 2017 Mar;45(3):415-421. doi: 10.1097/CCM.0000000000002183.

    PubMed 27922879
  • Alvarado Sanchez JI, Caicedo Ruiz JD, Diaztagle Fernandez JJ, Amaya Zuniga WF, Ospina-Tascon GA, Cruz Martinez LE. Predictors of fluid responsiveness in critically ill patients mechanically ventilated at low tidal volumes: systematic review and meta-analysis. Ann Intensive Care. 2021 Feb 8;11(1):28. doi: 10.1186/s13613-021-00817-5.

    PubMed 33555488
  • Feissel M, Teboul JL, Merlani P, Badie J, Faller JP, Bendjelid K. Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients. Intensive Care Med. 2007 Jun;33(6):993-9. doi: 10.1007/s00134-007-0602-6. Epub 2007 Mar 29.

    PubMed 17393139
  • Vincent JL, Sakr Y, Sprung CL, Ranieri VM, Reinhart K, Gerlach H, Moreno R, Carlet J, Le Gall JR, Payen D; Sepsis Occurrence in Acutely Ill Patients Investigators. Sepsis in European intensive care units: results of the SOAP study. Crit Care Med. 2006 Feb;34(2):344-53. doi: 10.1097/01.ccm.0000194725.48928.3a.

    PubMed 16424713
  • Natalini G, Rosano A, Taranto M, Faggian B, Vittorielli E, Bernardini A. Arterial versus plethysmographic dynamic indices to test responsiveness for testing fluid administration in hypotensive patients: a clinical trial. Anesth Analg. 2006 Dec;103(6):1478-84. doi: 10.1213/01.ane.0000246811.88524.75.

    PubMed 17122227
  • Cannesson M, Attof Y, Rosamel P, Desebbe O, Joseph P, Metton O, Bastien O, Lehot JJ. Respiratory variations in pulse oximetry plethysmographic waveform amplitude to predict fluid responsiveness in the operating room. Anesthesiology. 2007 Jun;106(6):1105-11. doi: 10.1097/01.anes.0000267593.72744.20.

    PubMed 17525584
  • Cannesson M, Desebbe O, Hachemi M, Jacques D, Bastien O, Lehot JJ. Respiratory variations in pulse oximeter waveform amplitude are influenced by venous return in mechanically ventilated patients under general anaesthesia. Eur J Anaesthesiol. 2007 Mar;24(3):245-51. doi: 10.1017/S026502150600161X. Epub 2006 Oct 23.

    PubMed 17054816
  • Cannesson M, Desebbe O, Rosamel P, Delannoy B, Robin J, Bastien O, Lehot JJ. Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre. Br J Anaesth. 2008 Aug;101(2):200-6. doi: 10.1093/bja/aen133. Epub 2008 Jun 2.

    PubMed 18522935
  • Landsverk SA, Hoiseth LO, Kvandal P, Hisdal J, Skare O, Kirkeboen KA. Poor agreement between respiratory variations in pulse oximetry photoplethysmographic waveform amplitude and pulse pressure in intensive care unit patients. Anesthesiology. 2008 Nov;109(5):849-55. doi: 10.1097/ALN.0b013e3181895f9f.

    PubMed 18946297
  • Liu T, Xu C, Wang M, Niu Z, Qi D. Reliability of pleth variability index in predicting preload responsiveness of mechanically ventilated patients under various conditions: a systematic review and meta-analysis. BMC Anesthesiol. 2019 May 8;19(1):67. doi: 10.1186/s12871-019-0744-4.

    PubMed 31068139
  • Monnet X, Guerin L, Jozwiak M, Bataille A, Julien F, Richard C, Teboul JL. Pleth variability index is a weak predictor of fluid responsiveness in patients receiving norepinephrine. Br J Anaesth. 2013 Feb;110(2):207-13. doi: 10.1093/bja/aes373. Epub 2012 Oct 26.

    PubMed 23103777
  • Coeckelenbergh S, Delaporte A, Ghoundiwal D, Bidgoli J, Fils JF, Schmartz D, Van der Linden P. Pleth variability index versus pulse pressure variation for intraoperative goal-directed fluid therapy in patients undergoing low-to-moderate risk abdominal surgery: a randomized controlled trial. BMC Anesthesiol. 2019 Mar 9;19(1):34. doi: 10.1186/s12871-019-0707-9.

    PubMed 30851740
  • Taccheri T, Gavelli F, Teboul JL, Shi R, Monnet X. Do changes in pulse pressure variation and inferior vena cava distensibility during passive leg raising and tidal volume challenge detect preload responsiveness in case of low tidal volume ventilation? Crit Care. 2021 Mar 18;25(1):110. doi: 10.1186/s13054-021-03515-7.

    PubMed 33736672

Questions about this trial

What is this clinical trial studying?

An observational study of Shock and Septic Shock, run by Bicetre Hospital at 1 site in France.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 23 Nov 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Xavier Monnet, MD-PhD (+33 06 60 86 26 69, xavier.monnet@aphp.fr), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Reliability of PVI changes in diagnosing preload responsiveness during TVC (time frame: TVC is performed in 1 minute). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05428423, which also lists 15 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 23 Nov 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in