AzTrials
AzTrials

Cardiopulmonary DiseaseNCT05445492

Respiration Validation for CPM Device

A study testing CPM Device in people with Cardiopulmonary Disease, run by Analog Device, Inc. at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study is designed to be a clinical validation study to ready the CPM System for FDA 510(k) submission. This study will be conducted as a prospective non-randomized. The study is non-significant risk since the CPM Device is noninterventional and noninvasive. Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
Conditions the study is for
Cardiopulmonary Disease
What is being tested?
CPM Device
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
41 participants
Where
1 siteUnited States
Study dates
22 Jun 2022to 11 Aug 2022
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Adults over the age of 18 and who are willing and able to give informed consent
  • Willing and able to participate in all activities related to this study, including trimming chest hair and wearing a reference device and the CPM wearable device
  • Volunteers of any race, any gender
  • Range of physiques
  • Healthy

Who cannot join

  • Injury or skin disturbance in the area of the test device
  • Allergies or sensitivities to silicone/acrylic-based adhesive
  • Pregnant
  • Currently smokes cigarettes
  • Has known respiratory conditions that might prevent them from following the study procedure such as:
  • Flu
Show all 12Show fewer
  • Pneumonia/bronchitis
  • Shortness of breath/respiratory distress
  • Respiratory or lung surgery
  • Emphysema, COPD, lung disease
  • Has self-reported heart or cardiovascular conditions such as chest pain, AFib, CHF, cardiomyopathy, or other conditions that could interfere with cardiopulmonary function
  • Has other self-reported health conditions that could interfere with the breathing patterns and exercises detailed in the protocol (including wearing a capnography mask)

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Clayton Sleep Institute

    St Louis, Missouri, 63123

Other trials in United States

About this study

Official title: Clinical Validation Study for Noninvasive Cardiopulmonary Management Device

This study is designed to be a clinical validation study to ready the CPM System for FDA 510(k) submission. This study will be conducted as a prospective non-randomized. The study is non-significant risk since the CPM Device is noninterventional and noninvasive. The study is primarily designed to validate the accuracy of the respiration rate and the changes in relative tidal volume. All participants will be fitted with both the CPM Device as well as reference devices (capnography and ECG). Participants will be randomized between 4 procedures (A-D) which will determine the order of 10 exercises. Each exercise has about 2 minutes of device recording and two minutes of rest. Each exercise contains two positions: sitting up for one minute and lying down for one minute. For some exercises, the participant will be instructed to breathe at a certain rate (assisted by a metronome). For other exercises, the participants will breathe at a normal rate but change how deep the are breathing. For the last, all capnography reference devices will be removed, and an ECG reference device will be placed. After exercise 18, the participant will have all devices removed and the study visit will terminate. The participant will receive a safety follow-up call about 1 week after their visit.

Being tested
CPM Device
Medical subject headings
Pulmonary Heart Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • CPM DeviceDevice

    The CPM device and reference device are used simultaneous to validate the CPM device.

Study groups in NCT05445492
Study groupRoleWhat they receive
Healthy CohortExperimentalThe target population for this cohort is healthy adult volunteers who do not have preexisting heart or lung conditions or illness. The goal is to recruit a participant population with a range of body types and BMIs and an approximately even split of genders and compare the reference device measurements to the test device.
Receives: Device: CPM Device

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Accuracy of CPM System Calculated RR Versus Reference Device Via Percent of Error Accuracy of Respiration Rate

    Percentage of respiration rate error within ± 2bpm. Acceptance criteria for clinical utility is >= 85%. The percentage of respiration rate within ± 2brpm was calculated by data points, regardless of its rate and breathing condition, which the CPM System did not screen, therefore reporting the numeric values. Each data point will produce binary result (True or False) if the error is within ± 2 brpm. Assuming this binary result follows a binominal distribution, its confidence interval is also calculated.

    Measured: 90 minutes

  2. Root Mean Squared Error (RMSE) of Respiration Rates From the CPM System vs Reference Device for Metronome Guided Breathing and Non-metronome Guided Breathing.

    First, the subject-specific linear fitting is performed after taking the natural log of both CPM's rTV and reference TV. Then, the residual errors in rTV after the fitting were calculated. Finally, all subject's residual errors are pooled together to calculate the root mean squared (RMS) residual relative errors. The confidence interval was calculated assuming the square of this error follows Chi-square distribution. This error characterized in a log-log domain is converted back to characterize a relative accuracy by taking an exponential of natural constant followed by subtraction of one. The RMS of residual error in % is characterized in this way because the linear fitting in the log-log domain and its residual errors represents faithful relative residual error regardless of an absolute value of TV.

    Measured: 90 minutes

Secondary outcomes (2)
  1. Performance of CPM System's ECG by % of CPM ECG Strip Equivalent to Lead II Strip

    Performance of CPM System's ECG is measurement by comparing CPM System ECG metrics to the reference device Lead II ECG strip. Clinicians reviewed the criteria below and decided if the CPM strip had equivalence to the Lead II strip.

    Measured: device measurement (3 minutes)

  2. ECG Accuracy Confirmation Comparing CPM Systems Generated ECG Metrics and Reference Lead II Generated ECG Metrics

    Determine the accuracy of CPM System's ECG metrics to the reference device. Results are displayed as mean error with standard deviation of error.

    Measured: device measurement (3 minutes)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted6 Jul 2022
  2. Study start22 Jun 2022
  3. Primary completion4 Aug 2022
  4. Study completion11 Aug 2022

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Model description
Non-randomized control trial
Masking
None (open label)
Enrolment
41 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05445492
Sponsor's protocol ID
Resp CPM Validation Clayton
Status last verified
May 2024
First submitted
30 Jun 2022
Last updated
12 Jun 2024
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing CPM Device in people with Cardiopulmonary Disease, run by Analog Device, Inc. at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 12 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 12 Jun 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 12 Jun 2024). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Accuracy of CPM System Calculated RR Versus Reference Device Via Percent of Error Accuracy of Respiration Rate (time frame: 90 minutes). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 Jun 2024.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in