AzTrials
AzTrials

Peripheral Arterial DiseaseNCT05447052

The Biomimetic Stent and Vascular Functions Study

A study testing Bio-MIMICS 3D Stent and Innova Stent in people with Peripheral Arterial Disease, run by University Hospital, Essen at 1 site in Germany.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The aim of this IIT is to determine the potential improvement and impact of the BioMimics 3D Stent System in the SFA on local vascular function. Read more about this study

Who is it for?
Ages 18 to 85 years
Conditions the study is for
Peripheral Arterial Disease
What is being tested?
Bio-MIMICS 3D Stent and Innova Stent
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
70 participants
Where
1 siteGermany
Study dates
26 Apr 2021to 26 Apr 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 85 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Peripheral artery disease
  • Target lesions in the proximal (3 cm distal to the CFA-bifurcation) middle and distal SFA
  • Clinical diagnosis of chronic, symptomatic lower limb ischemia as defined by Rutherford 2,3,4
  • Planed peripheral intervention TASC A-D
  • Subject must be between 18 and 85 years old
  • Female of childbearing potential must have a negative pregnancy test within 10 days prior to index procedure and utilize reliable birth control until completion of the 12 month angiographic evaluation
Show all 12Show fewer
  • Vessel diameter >/= 4.0 mm and </=7.0 mm
  • Target lesion length < 140 mm (segment to be stented)
  • Willing to comply with the specified follow-up evaluation
  • Written informed consent prior to any study procedures
  • Pretreatment with an adequately sized ballon (1:1 ration to nonstenotic vessel diameter)
  • usage of Biomimics stent as described in the IFU, especially regarding stent diameters and vessel size

Who cannot join

  • Bifurcational lesions of the CFA and lesions including the first 3 cm of the SFA, due to technical aspects of FMD measurement
  • Requiring stent implantation in the PA
  • Instent-Restenosis
  • Thrombolysis within 72 Hours prior to the index procedure
  • Aneurysm formations in the femoral artery or popliteal artery
  • Concomitant hepatic insufficiency, deep venous thrombus, coagulation disorder or receiving immunosuppressant therapy
Show all 13Show fewer
  • Unstable angina pectoris at the time of the enrollment
  • Recent myocardial infarction or stroke <30 days prior to the index procedure
  • Life expectancy less than 12 months
  • Septicaemia at the time of enrollment
  • Known or suspected active infection at the time of the index procedure, excluding an infection of a lower extremity wound of the target limb
  • Known or suspected allergies or contraindications to aspirin, clopidogrel or heparin
  • Presence of other hemodynamically significant outflow lesions in the target limb requiring a planned surgical intervention or endovascular procedure within 30 days after the index procedure

Trial locations and contacts

1 site in 1 country.

Christos Rammos, Professor contact

0201-723-84808

christos.rammos@uk-essen.de

Tienush Rassaf, Professor contact

0201-723-4801

tienush.rassaf@uk-essen.de

Germany1 site, 1 recruiting
  • University of Essen, Clinic of Cardiology and Angiology

    Essen, North Rhine-Westphalia, 45147

    Christos Rammos, Prof., +4920172384808, christos.rammos@uk-essen.de

    Tienush Rassaf, Univ.-Prof., +492017234801, tienush.rassaf@uk-essen.de

    Recruiting

Other trials in Germany

About this study

Official title: The Biomimetic Stent and Vascular Functions Study-The MIMICS FLOW STUDY

The aim of this IIT is to determine the potential improvement and impact of the BioMimics 3D Stent System in the SFA on local vascular function.

Read the detailed description

The MIMICS FLOW Study is a single-center, single-blind, investigator-initiated, randomized parallel group trial.

The impact of a novel biomimetical stent with a helical curvature provides superior hemodynamic and biomechanical performance and advantages. Additionally, it promotes swirling blood flow, elevating wall sheer strength, which is patency-protective and might impact on vascular functions due to completely different vascular properties through altered blood flow.

The influence of the novel devices and stent-platforms with improved hemodynamic capabilities with respect to vasomotor of the vessel wall, vascular function and vascular compliance can be measured by FMD, arterial stiffness indices and vascular strain analysis.

Being tested
Bio-MIMICS 3D Stent, Innova Stent
Medical subject headings
Peripheral Arterial Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Bio-MIMICS 3D StentDevice

    Bio-MIMICS Stent implantation

  • Innova StentDevice

    Innova Stent implantation

Study groups in NCT05447052
Study groupRoleWhat they receive
Bio-MIMICS StentExperimentalHelical shaped BioMimics 3D Stent
Receives: Device: Bio-MIMICS 3D Stent
Innova StentActive comparatorConventional: Nitinol Stent
Receives: Device: Innova Stent

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Change of flow-mediated vasodilation (FMD) of the nonstenotic segment of the proximal SFA after procedure

    FMD represents the percent diameter gain as calculated based on preischemia and postischemia diameter measurements of the femoral artery.

    Measured: 1 month

  2. Change of flow-mediated vasodilation (FMD) of the nonstenotic segment of the proximal SFA after procedure

    FMD represents the percent diameter gain as calculated based on preischemia and postischemia diameter measurements of the femoral artery.

    Measured: 12 months

Secondary outcomes (12)
  1. Changes in pulse wave velocity

    Changes in cardiovascular function measured by pulse wave velocity in m/s

    Measured: Baseline, followed at 1 and 12 months

  2. Changes in augmentation index

    Changes in cardiovascular function measured by augmentation index in %

    Measured: Baseline, followed at 1 and 12 months

  3. Changes in vascular strain

    Changes in cardiovascular function measured by vascular strain in %

    Measured: Baseline, followed at 1 and 12 months

  4. Changes in peripheral perfusion determined by ABI (ankle brachial index)

    ABI measurements are conducted using a Doppler probe on tibial and anterior artery locations. The highest value will be used for calculation and divided by the highest systolic brachial Doppler pressure

    Measured: Baseline, followed at 1 and 12 months

  5. Primary patency (PP) of target lesion

    Primary patency determined by PVR measurement with ultrasound

    Measured: Baseline, followed at 1 and 12 months

  6. Changes in clinical symptoms

    Clinical symptoms of patients determined by Walking impairment questionaire (WIQ)

    Measured: Baseline, followed at 1 and 12 months

  7. Changes in six-minute walk test

    Six-minute walk test determined by pain-free walking distance in m

    Measured: Baseline, followed at 1 and 12 months

  8. Freedom from Target Lesion Revascularization

    Freedom from Target Lesion Revascularization (FTLR)

    Measured: Baseline, followed at 1 and 12 months

  9. Number of participants with treatment-related adverse events

    Number of participants with treatment-related adverse events as assessed by SDWS

    Measured: Baseline, followed at 1 and 12 months

  10. Changes of inflammatory profile measured by hs-CRP in mg/dl

    Blood samples are collected at the below mentioned time points

    Measured: Baseline, followed at 1 and 12 months

  11. Changes of inflammatory profile measured by oxLDL in µg/l

    Blood samples are collected at the below mentioned time points

    Measured: Baseline, followed at 1 and 12 months

  12. Changes of inflammatory profile measured by Interleukin-6 in pg/ml

    Blood samples are collected at the below mentioned time points

    Measured: Baseline, followed at 1 and 12 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted7 Jul 2022
  2. Study start26 Apr 2021
  3. Primary completion26 Apr 2024 (estimated)
  4. Study completion26 Apr 2025 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Participant
Enrolment
70 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05447052
Sponsor's protocol ID
The MIMICS FLOW STUDY
Status last verified
Dec 2023
First submitted
2 Jun 2022
Last updated
5 Dec 2023
Results posted
No
FDA-regulated drug
No
FDA-regulated device
Yes

Questions about this trial

What is this clinical trial studying?

A study testing Bio-MIMICS 3D Stent and Innova Stent in people with Peripheral Arterial Disease, run by University Hospital, Essen at 1 site in Germany.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 12 inclusion and 13 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 5 Dec 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Christos Rammos, Professor (0201-723-84808, christos.rammos@uk-essen.de), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Change of flow-mediated vasodilation (FMD) of the nonstenotic segment of the proximal SFA after procedure (time frame: 1 month). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 5 Dec 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in