AzTrials
AzTrials

Aortic Valve StenosisBESTNCT05454150

Balloon-Expandable Versus Self-expanding Transcatheter Heart Valve for Treatment of Symptomatic Native Aortic Valve Stenosis (BEST)

A study testing balloon-expandable valve and self-expanding valve in people with Aortic Valve Stenosis, run by University Hospital, Lille at 21 sites in France.

Active, not recruiting

Under way, not looking for participants. Everyone needed has enrolled. The study is still running.

Official record
Search all trials

Trial summary

Over the last years, several randomized studies comparing transcatheter aortic valve implantation (TAVI) to surgical aortic valve replacement (SAVR) have established TAVI as a treatment option in symptomatic patients with aortic stenosis (AS) (1,2,3). Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Aortic Valve Stenosis
What is being tested?
balloon-expandable valve and self-expanding valve
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
1,960 participants
Where
21 sitesFrance
Study dates
19 Apr 2023to 29 Dec 2035
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Symptomatic severe aortic stenosis defined according to the current echocardiography criteria of the European Society of Cardiology guidelines2.
  • Heart team of the investigating center agrees that the patient is eligible to TAVI with BE-valve SAPIEN 3 (Edwards Lifesciences©) (or further iterations of the same family) OR TAVI with the SE-valve Evolut-R/pro (Medtronic©) (or futher iterations of the same family).
  • Heart team of the investigating center agrees that TAVI is feasible via percutaneous transfemoral approach.
  • Written informed consent to the BEST study
  • Written informed consent to the FRANCE-TAVI registy
  • All valve anatomy are authorized (bicuspid or tricuspid aortic valve)

Who cannot join

  • Age < 18 years old
  • Patient with legal protection
  • Non-affiliation to a social security scheme
  • Pregnancy
  • Subject participating in another research protocol on TAVI procedure
  • Patients presenting with an anatomy that is regarded unsuitable for the implantation of one of the two valve types
Show all 11Show fewer
  • TAVI through nontransfemoral approach or surgical cutdown
  • Valve-in-valve procedure (TAVI in TAVI or TAVI in surgical aortic bioprosthesis)
  • Implantation of Accurate Neo or Accurate Neo2 valve (Boston scientific)
  • Severe aortic regurgitation (>3+)
  • Refusal to participate to FRANCE-TAVI registry

Trial locations and contacts

21 sites in 1 country.

21 sites in 1 country

France21 sites
  • CH Annecy Genevois

    Annecy

  • CHU de Besançon

    Besançon

  • CHU de Caen

    Caen

  • Hôpital Privé Saint-Martin

    Caen

  • CHU de Clermont-Ferrand

    Clermont-Ferrand

  • AP-HP Hôpitaux Universitaires Henri Mondor

    Créteil

  • CHU de Grenoble

    Grenoble

  • Institut Cardiovasculaire Paris Sud

    Massy

  • CHU de Montpellier

    Montpellier

  • CHU de Nîmes

    Nîmes

  • AP-HP Hôpitaux Universitaires Pitié Salpêtrière

    Paris

  • Institut Mutualiste Montsouris

    Paris

  • CHU de Bordeaux Hôpital Pellegrin

    Pessac

  • CHU Reims - Hôpitam Robert Debré

    Reims

  • CHU de Saint-Etienne

    Saint-Etienne

  • CHU de Nantes - Hôpital Laennec

    Saint-Herblain

  • Centre Médico Chirurgical Arnault Tzanck

    Saint-Laurent-du-Var

  • CHU de Strasbourg

    Strasbourg

  • CHU de Toulouse

    Toulouse

  • CHU de Tours

    Tours

  • Médipôle Lyon Villeurbanne

    Villeurbanne

Other trials in France

About this study

Official title: Balloon-Expandable Versus Self-expanding Transcatheter Heart Valve for Treatment of Symptomatic Native Aortic Valve Stenosis

Over the last years, several randomized studies comparing transcatheter aortic valve implantation (TAVI) to surgical aortic valve replacement (SAVR) have established TAVI as a treatment option in symptomatic patients with aortic stenosis (AS) (1,2,3). Most transcatheter heart valves (THV) available are designed on either a balloon-expandable (BE) or a self-expanding (SE) concept.

Despite major differences, both designs are recommended to be used indifferently in most of the clinical situations and a significant number of centers only implant one of this two THV design. It remains unclear however, whether these 2 very different THV concepts are achieving similar or different clinical outcomes and could be considered a single "Class" of device. While there is an urgent clinical need to clarify this issue in an exponentially growing therapeutic field, to date no large randomized study powered to compare the 2 THV designs on individual endpoints has been conducted or initiated. Recently, two large-scale French registry-based propensity matched analyses, including more than 30,000 patients, have reported a higher 90 days and 1-year mortality with the use of SE as compared to BE-valve (4,5). However, as the propensity-score matching-approach cannot rule out residual confounders, and as some of the most recent THV iterations were not part of the investigation, there is an urgent need to conduct a randomized trial sufficiently powered to compare head-to-head the latest generation of SE and BE-valve on all-cause mortality. In addition, two small randomized studies have recently showed the inferiority of a new SE-valve compared to BE-valve and SE-THV (SCOPE1 trial, J Lanz. Lancet. 2019 Nov 2;394(10209):1619-1628. and SCOPE 2 trial, Circulation in press), thus further questioning wether THV should be considered as a single \&#34;Class\&#34; regardless the THV design.

Read more

The objective of the present randomized clinical investigation will be to evaluate the impact of THV design (SE vs BE) on the risk of all-cause mortality at 90 days and 1 year.

The present clinical investigation will the first randomized clinical investigation to compare head to head the benefit of BE-valve over SE-valve on total mortality and /or disabling stroke at 90 days and 1-year using a superiority design. Previous head-to-head studies included only a small number of patients, non-inferiority designs and combined endpoints. This clinical investigation will be the first to generate sufficient evidences to change clinical practice and international guidelines to clarify whether one THV design is superior (or not) to the other one (BE vs SE-valve). The result of the clinical investigation is key for clinicians indicating the treatment and for the patients receiving the treatment

Being tested
balloon-expandable valve, self-expanding valve
Keywords
Aortic valve stenosis, TAVI, Balloon-expandable transcatheter heart valve, Self-expanding transcatheter heart valve,, heart valve disease
Medical subject headings
Aortic Valve Stenosis, Heart Valve Diseases

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • balloon-expandable valveDevice

    Sapien 3/Ultra, Edwards Lifesciences©

  • self-expanding valveDevice

    Evolut R/Pro, Medtronic©

Study groups in NCT05454150
Study groupRoleWhat they receive
TAVI with balloon-expandable valve (Sapien 3/Ultra, Edwards Lifesciences©)ExperimentalNot described
Receives: Device: balloon-expandable valve
TAVI with self-expanding valve (Evolut R/Pro, Medtronic©)Active comparatorNot described
Receives: Device: self-expanding valve

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. composite of: device technical failure at exit from procedure room and/or all-cause mortality and/or disabling stroke

    An independent clinical event committee (CEC) will adjudicate clinical events according to the VARC-3 definitions.

    Measured: at 90-day after TAVI

Secondary outcomes (11)
  1. Composite of device failure, and/or all-cause mortality and/or disabling stroke

    An independent clinical event committee (CEC) will adjudicate clinical events according to the VARC-3 definitions.

    Measured: at 1 year after TAVI

  2. 2Composite of device technical failure, all-cause mortality and/or disabling stroke

    An independent clinical event committee (CEC) will adjudicate clinical events according to the VARC-3 definitions.

    Measured: At 90 days after TAVI

  3. Device technical failure

    Freedom from mortality, Successful access, delivery of the device and retrieval of the delivery system, Correct positioning of a single prosthetic heart valve into the proper anatomical location, Freedom from surgery or intervention related to the device or to a major vascular or access-related, or cardiac structural complication

    Measured: at exit from procedure room

  4. Safety

    • Technical success at exit from procedure room (VARC 3)*
    • Freedom from all-cause mortality
    • Freedom from all stroke
    • Freedom from VARC type 2-4 bleeding
    • Freedom from major vascular access-related complication
    • Freedom from cardiac structural complication
    • Freedom from acute kidney injury stage 3 or 4
    • Freedom from moderate or severe aortic regurgitation
    • Freedom from new permanent pacemaker due to procedure-related conduction abnormalities
    • Freedom from surgery or intervention related to the device

    Measured: at 90 days after TAVI

  5. Device Success

    • Technical success at exit from procedure room
    • Freedom from mortality
    • Freedom form surgery or intervention related to the device or to a major vascular or access-related or major cardiac structural complication
    • Intended performance of the valve (mean gradient < 20mmHg, peak velocity <3m/s, Doppler Velocity index ≥ 0.25, and less than moderate aortic regurgitation

    Measured: at 90 days after TAVI

  6. Clinical efficacy Clinical efficacy

    Ao Technical success at exit from procedure room (VARC 3)*

    • Freedom from all-cause mortality
    • Freedom from all stroke
    • Freedom from hospitalization for procedure- or valve-related causes
    • Freedom from KCCQ Overall Summary Score <45 or decline from baseline of >10 point (i.e. Unfavourable Outcome)

    Measured: at 1 year after TAVI

  7. Valve-related clinical efficacy

    • Technical success of the TAVI procedure*
    • Intended performance of the valve
    • Freedom from severe PPM at discharge (or 90 days)†
    • Freedom from endocarditis†
    • Freedom from bioprosthesis Valve Failure (BVF)
    • Freedom from stroke or peripheral embolism (presumably valve-related, after ruling out other non-valve aetiologies)
    • Freedom from VARC Type 2-4 bleeding secondary to or exacerbated by antiplatelet or anticoagulant agents, used specifically for valve-related concerns

    Measured: at 1 year after TAVI

  8. composite outcome from a patient perspective

    The rate of favourable outcome risk of death

    Measured: AT 90 days and 1 year afet TAVU

  9. Valve Durability defined as all-cause BVF tricuspid aortic valve

    An independant corelaboratory will review all images. An independent clinical event committee (CEC) will adjudicate clinical events according to the VARC-3 definitions.

    Measured: At 90days and 1 year after TAVI

  10. 11) Stage 2 or 3 hemodynamic valve deterioration

    according to VARC-3 n independent clinical event committee (CEC) adjudicate clinical events

    Measured: At 1 year after TAVI

  11. device technical failure at exit from procedure room and/or all-cause mortality and/or disabling strok

    according to VARC-3 n independent clinical event committee (CEC) adjudicate clinical events

    Measured: at 3, 5, 7 and 10 years after TAVI

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted12 Jul 2022
  2. Study start19 Apr 2023
  3. Primary completion29 Oct 2025
  4. Study completion29 Dec 2035 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
1,960 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05454150
Sponsor's protocol ID
2021_0513
Other IDs
2021-A02554-37
Acronym
BEST
Status last verified
Nov 2025
First submitted
7 Jul 2022
Last updated
4 Dec 2025
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing balloon-expandable valve and self-expanding valve in people with Aortic Valve Stenosis, run by University Hospital, Lille at 21 sites in France.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 11 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: under way, not looking for participants, as of the sponsor's last update on 4 Dec 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 21 sites in France. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

composite of: device technical failure at exit from procedure room and/or all-cause mortality and/or disabling stroke (time frame: at 90-day after TAVI). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Dec 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in