Mechanical Insufflator/Exsufflator Technique in Children With Neuromuscular Disease

A study testing Mechanical insufflation/exsufflation conventional and Mechanical insufflation/exsufflation modified in people with Neuromuscular Diseases in Children, run by Insel Gruppe AG, University Hospital Bern at 1 site in Switzerland.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

In a randomized cross-over design, two different modes of a mechanical insufflator/exsufflator applied to pediatric subjects with neuromuscular disease will be compared with respect to their short term effect on lung function, i.e. lung volume. Read more about this study

Who is it for?
Ages 5 to 16 years
Conditions the study is for
Neuromuscular Diseases in Children
What is being tested?
Mechanical insufflation/exsufflation conventional and Mechanical insufflation/exsufflation modified
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
7 participants
Where
1 siteSwitzerland
Study dates
1 Feb 2023to 20 Dec 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 5 to 16 years
  • All sexes
  • No healthy volunteers
  • Child

Who may be able to join

  • Confirmed diagnosis of a NMD
  • Functional status: non-ambulatory
  • Age >5 years and < 16 years
  • Able to cooperate
  • Daily home-use of cough assist as reported by the caregivers
  • Written informed consent by the subject/caregiver

Who cannot join

  • Acute respiratory infection at two consecutive outpatient clinic visits (marked increase in cough, change in sputum amount or colour, fever or malaise)
  • Oxygen dependency (defined as need for oxygen to achieve a transcutaneous oxygen saturation of ≥92%)
  • Skin lesions at the chest (preventing EIT measurements)
  • Chest deformation preventing EIT measurements

Trial locations and contacts

1 site in 1 country.

Switzerland1 site
  • Inselspital

    Bern, Canton of Bern, 3010

Other trials in Switzerland

About this study

Official title: Mechanical INsufflator/EXsufflator Technique in Paediatric Subjects With Neuromuscular Disease: a Randomised Crossover Comparison of 2 Modes of Application

In a randomized cross-over design, two different modes of a mechanical insufflator/exsufflator applied to pediatric subjects with neuromuscular disease will be compared with respect to their short term effect on lung function, i.e. lung volume.

Read the detailed description

At two consecutive regular outpatient clinic visits, each participant will perform a session of the insufflation/exsufflation technique.

Participants will be randomised by a computer-generated code to one of the two sequences (CON-MOD or MOD-CON) using sealed envelopes. The randomisation list will be generated by a study nurse of the Department of Paediatrics who is not a member of the study group.

The randomisation envelope will be opened by the treating physiotherapist immediately before the first treatment session.

Standardised intervention

At randomisation, the measurement belt of the EIT system will be fitted around the chest of the participant. Once correct fit is confirmed, the baseline measurement (T0) will be taken. After the baseline assessment, the participants will perform the conventional (CON) or modified (MOD) insufflator/exsufflator therapy session under supervision of a physiotherapist. In teh investigator's institution a therapy session consists of 5 series of 5 insufflation/exsufflation manoeuvres each (Cough assist E70, Philips Respironics, Hamburg, Germany). Positive and negative pressures will be set at the individual level of each subject.

Measurements Changes in lung volume and ventilation distribution will be assessed by electrical impedance tomography (EIT). These parameters will be obtained five minutes before (T0) and five, ten, twenty, forty and sixty minutes after the treatment session (T1 - T5). Measurements of 3 minutes will be recorded at each time point. Additionally EIT measurements will be performed continuously during the treatment session.

Electrical Impedance Tomography (EIT) is a non-invasive, radiation-free technique for the assessment of spatial and temporal ventilation distribution based on the changes in electrical properties of the tissue during the respiratory cycle. EIT measurements will be performed using a commercially available setup (PulmoVista 500, Draeger, Germany). Image reconstruction will be performed with the GREIT-algorithm using the torso mesh function. [Adler, 2009] Relative change in end-expiratory lung impedance (EELI) and the global inhomogeneity (GI) index, a measure of ventilation inhomogeneity, will be calculated using customized software (Matlab® R2021b, The MathWorks Inc., Nattick, MA, USA).

Being tested
Mechanical insufflation/exsufflation conventional, Mechanical insufflation/exsufflation modified
Keywords
Lung function

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Mechanical insufflation/exsufflation conventionalDevice

    Conventional settings in a commercially available chest physiotherapy device

  • Mechanical insufflation/exsufflation modifiedDevice

    Modified settings in a commercially available chest physiotherapy device

Study groups in NCT05454215
Study groupRoleWhat they receive
Conventional settings first, modified settings secondActive comparatorThe control intervention (CON) is the conventional mode of a commercially available mechanical insufflator/exsufflator. The manoeuvre consists of 5 sets of 5 mechanical insufflations/exsufflations with individual pressure settings. For the study, the same pressure settings will be used as during daily routine. The study intervention (MOD) is a modified mode of a commercially available mechanical insufflator/exsufflator in which the active exsufflation of the last breath of each set will be omitted. The manoeuvre consists of 5 sets of 5 mechanical insufflations/exsufflations with individual pressure settings. For the study, the same pressure settings will be used as during daily routine. This modified mode is already used in daily routine by a minority of subjects with NMD.
Receives: Device: Mechanical insufflation/exsufflation conventional; Device: Mechanical insufflation/exsufflation modified
Modified settings first, conventional settings secondExperimentalThe study intervention (MOD) is a modified mode of a commercially available mechanical insufflator/exsufflator in which the active exsufflation of the last breath of each set will be omitted. The manoeuvre consists of 5 sets of 5 mechanical insufflations/exsufflations with individual pressure settings. For the study, the same pressure settings will be used as during daily routine. This modified mode is already used in daily routine by a minority of subjects with NMD. The control intervention (CON) is the conventional mode of a commercially available mechanical insufflator/exsufflator. The manoeuvre consists of 5 sets of 5 mechanical insufflations/exsufflations with individual pressure settings. For the study, the same pressure settings will be used as during daily routine.
Receives: Device: Mechanical insufflation/exsufflation conventional; Device: Mechanical insufflation/exsufflation modified

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Change in end-expiratory lung impedance from baseline

    Change of end-expiratory lung volume estimated by electrical impedance tomography from baseline to immediately after a session of mechanical insufflation/exsufflation.

    Measured: 3-5 Minutes

Secondary outcomes (2)
  1. Change in ventilation distribution from baseline

    Differences in ventilation distribution assessed with electrical impedance tomography from baseline to immediately after a session of mechanical insufflation/exsufflation.

    Measured: 3-5 Minutes

  2. Duration of effect

    Duration of the postulated effect on lung volume assessed by electrical impedance tomography.

    Measured: 15-20 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted12 Jul 2022
  2. Study start1 Feb 2023
  3. Primary completion7 Dec 2024
  4. Study completion20 Dec 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Prevention
Allocation
Randomised
Intervention model
Crossover
Model description
Single center non-blinded randomized crossover trial
Masking
None (open label)
Enrolment
7 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05454215
Sponsor's protocol ID
MINEX-2
Acronym
MINEX-2
Status last verified
Jan 2025
First submitted
6 Jul 2022
Last updated
8 Jan 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes: IPD sharing upon request

Publications

  • Casaulta C, Messerli F, Rodriguez R, Klein A, Riedel T. Changes in ventilation distribution in children with neuromuscular disease using the insufflator/exsufflator technique: an observational study. Sci Rep. 2022 Apr 29;12(1):7009. doi: 10.1038/s41598-022-11190-z.

    PubMed 35488044

Questions about this trial

What is this clinical trial studying?

A study testing Mechanical insufflation/exsufflation conventional and Mechanical insufflation/exsufflation modified in people with Neuromuscular Diseases in Children, run by Insel Gruppe AG, University Hospital Bern at 1 site in Switzerland.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 8 Jan 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Switzerland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Change in end-expiratory lung impedance from baseline (time frame: 3-5 Minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05454215, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Jan 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in