AzTrials
AzTrials

Lung DiseasesNCT05462275

Impact of Patient Position on the Success in Placing Triple-cuffed Double Lumen Endotracheal Tube

A study testing Intubation using 3-cuffed double lumen endotracheal tube in people with Lung Diseases, run by Hansu Bae at 1 site in South Korea.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Triple-cuffed double lumen endotracheal tube (TC-DLT, ANKOR tube. Insung corp., Korea) which was developed to isolate lung without endotracheal bronchoscope guidance has additional carinal cuff placed between bronchial tube cuff and tracheal tube cuff. Read more about this study

Who is it for?
Ages 19 to 85 years
Conditions the study is for
Lung Diseases
What is being tested?
Intubation using 3-cuffed double lumen endotracheal tube
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
167 participants
Where
1 siteSouth Korea
Study dates
29 Apr 2022to 29 Apr 2023
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 19 to 85 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Adults who is including in ASA class I or II
  • Patients scheduled for right lung surgery under right lung isolation
  • Patients who don't have any anatomical variations in pulmonary system
  • Patients who have never gotten a lung surgery

Who cannot join

  • Pregnancy
  • Patients who are predicted difficult intubation
  • Patients who is under upper airway infection
  • Patients who have coagulopathy
  • Emergency surgery
  • In addition, patients considered inappropriate to participate in this study

Trial locations and contacts

1 site in 1 country.

South Korea1 site, 1 recruiting
  • Dongguk University Il-san hospital

    Goyang-si, Geyonggi-do, 10323

    Hansu Bae, 082-010-6326-1641, hsbae81@gmail.com

    Dongkyu Lee, 082-010-6431-4217, entopic@naver.com

    Recruiting

Other trials in South Korea

About this study

Official title: Impact of Patient Position on the Success in Placing Triple-cuffed Double Lumen Endotracheal Tube : Multi-center Observational Study

Triple-cuffed double lumen endotracheal tube (TC-DLT, ANKOR tube. Insung corp., Korea) which was developed to isolate lung without endotracheal bronchoscope guidance has additional carinal cuff placed between bronchial tube cuff and tracheal tube cuff. This device has been successfully used to isolate lung more simply in specific settings when there is too much excretion to visualize endotracheal structure or for a health provider who is not good at use of traditional double-lumen tube. Although TC-DLT is designed to enable lung separation effectively in situations that confirmation of tube position using bronchoscopy is difficult or not available, but no studies have been conducted on whether effective lung isolation using TC-DLT is possible after change in the relative position of the bronchial tree by postural change. This plan was prepared for research on this.

Read the detailed description

After enter into operating room, induction of anesthesia is performed through standard general anesthesia procedure before endotracheal intubation. Endotracheal intubation is performed using TC-DLT and inflate carinal cuff with 5 ~ 15ml of air. Then, push it into trachea until resistance is felt. When carinal cuff is placed at carina, deflate carinal cuff and isolate independent lung followed by confirmation of bronchial cuff position using fiberoptic bronchoscopy.

Record the location of the bronchial balloon in one of the following conditions

  1. at proper position(proximal upper end of bronchial balloon is between 5mm from carinal opening) :
  2. proximal end of bronchial balloon is placed more of 5mm distally from carinal opening
  3. proximal end of bronchial balloon is placed more of 5mm proximally from carinal opening

Then, change patient position to left lateral decubitus (LLD) position and check the position of bronchial balloon using fiberoptic bronchoscopy as previously done.

  1. at proper position(proximal upper end of bronchial balloon is between 5mm from carinal opening) :
  2. proximal end of bronchial balloon is placed more of 5mm distally from carinal opening
  3. proximal end of bronchial balloon is placed more of 5mm proximally from carinal opening

After check whether there is something to considerate, end this case.

Conditions
Lung Diseases
Being tested
Intubation using 3-cuffed double lumen endotracheal tube
Keywords
3-cuffed double lumen tube, one lung ventilation, lung isolation
Medical subject headings
Lung Diseases

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Intubation using 3-cuffed double lumen endotracheal tubeDevice

    After patient's position, 3-cuffed double lumen endotracheal tube is intubated without fiberoptic bronchoscopy guidance

Study groups in NCT05462275
Study groupRoleWhat they receive
Test groupExperimentalThere is only one group to evaluate this observational study.
Receives: Device: Intubation using 3-cuffed double lumen endotracheal tube

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Success rate of 3-cuffed double lumen tube inserted in lateral position

    Authors insert 3-cuffed double lumen tube after position change to left lateral decubitus with blind fashion. At this time, probability that the tube will be inserted to an appropriate depth is primary endpoint.

    Measured: During procedure(Immediately after secondary intubation)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted18 Jul 2022
  2. Study start29 Apr 2022
  3. Primary completion29 Apr 2023 (estimated)
  4. Study completion29 Apr 2023 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Health services research
Allocation
Not applicable
Intervention model
Single group
Model description
Interventional observational study. The investigators conduct this study to analyze the impact of patient position on the success in placing triple-cuffed double lumen endotracheal tube.
Masking
None (open label)
Enrolment
167 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05462275
Sponsor's protocol ID
Ankor-1
Status last verified
Jul 2022
First submitted
6 Jul 2022
Last updated
18 Jul 2022
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: This study is multi center observational study and we will not share any patients data with other center

Publications

  • Boisen ML, Schisler T, Kolarczyk L, Melnyk V, Rolleri N, Bottiger B, Klinger R, Teeter E, Rao VK, Gelzinis TA. The Year in Thoracic Anesthesia: Selected Highlights from 2019. J Cardiothorac Vasc Anesth. 2020 Jul;34(7):1733-1744. doi: 10.1053/j.jvca.2020.03.016. Epub 2020 Apr 18.

    PubMed 32430201
  • Boisen ML, Fernando RJ, Kolarczyk L, Teeter E, Schisler T, La Colla L, Melnyk V, Robles C, Rao VK, Gelzinis TA. The Year in Thoracic Anesthesia: Selected Highlights From 2020. J Cardiothorac Vasc Anesth. 2021 Oct;35(10):2855-2868. doi: 10.1053/j.jvca.2021.04.012. Epub 2021 Apr 17.

    PubMed 34053812
  • Seo Y, Kim N, Paik HC, Park D, Oh YJ. Successful blind lung isolation with the use of a novel double-lumen endobronchial tube in a patient undergoing lung transplantation with massive pulmonary secretion: A case report. Medicine (Baltimore). 2019 Aug;98(33):e16869. doi: 10.1097/MD.0000000000016869.

    PubMed 31415423
  • Kim N, Byon HJ, Kim GE, Park C, Joe YE, Suh SM, Oh YJ. A Randomized Controlled Trial Comparing Novel Triple-Cuffed Double-Lumen Endobronchial Tubes with Conventional Double-Lumen Endobronchial Tubes for Lung Isolation. J Clin Med. 2020 Apr 1;9(4):977. doi: 10.3390/jcm9040977.

    PubMed 32244659
  • Ball WS, Wicks JD, Mettler FA Jr. Prone-supine change in organ position: CT demonstration. AJR Am J Roentgenol. 1980 Oct;135(4):815-20. doi: 10.2214/ajr.135.4.815.

    PubMed 6778119

Questions about this trial

What is this clinical trial studying?

A study testing Intubation using 3-cuffed double lumen endotracheal tube in people with Lung Diseases, run by Hansu Bae at 1 site in South Korea.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 18 Jul 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Hansu Bae (082-010-6326-1641, hsbae81@gmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Success rate of 3-cuffed double lumen tube inserted in lateral position (time frame: During procedure(Immediately after secondary intubation)). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05462275, which also lists 5 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Jul 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in