Transfemoral tranScatheter Aortic valvE ImplantationULISSENCT05468762
Ultrasound arteriaL Stiffness evaluatIon and vaScular Complications in Patients Undergoing Transfemoral tranScatheter Aortic valvE Implantation: ULISSE Study.
An observational study of Transfemoral tranScatheter Aortic valvE Implantation, run by Dr. Giuseppe Musumeci at 1 site in Italy.
Trial summary
Transcatheter aortic valve implantation (TAVI) is an established treatment modality in patients ≥ 75 years old with severe symptomatic aortic stenosis after Heart Team evaluation (1). Read more about this study
- Who is it for?
- Ages 75 years and older
- Conditions the study is for
- Transfemoral tranScatheter Aortic valvE Implantation
- What is being tested?
- Transfemoral tranScatheter aortic valvE implantation
- Type of treatment
- Surgery or procedure
- How many people
- 120 participants
- Where
- 1 siteItaly
- Study dates
- 1 Aug 2022to 1 Aug 2023
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 75 years and older
- All sexes
- Older adult
Study population: patients ≥ 75 years old with severe symptomatic aortic stenosis after Heart Team evaluation
Who may be able to join
- Age ≥ 18 years
- Patients eligible for transfemoral TAVI.
Who cannot join
- Conditions determining inadequate windows for evaluation of pulse wave doppler both at aortic arch and femoral artery level.
- CT scan not performed.
- Planned surgical access.
Trial locations and contacts
1 site in 1 country.
Italy1 site
A.O. Ordine Mauriziano
Torino, 10131
Francesco Maiellaro, Medicine, francescomll91@gmail.com
Lucia Borsotti, Law, sperimentazioni@mauriziano.it
About this study
Transcatheter aortic valve implantation (TAVI) is an established treatment modality in patients ≥ 75 years old with severe symptomatic aortic stenosis after Heart Team evaluation (1). Patients with high/prohibitive surgical risk and life expectancy ≥ 1 years are candidates for TAVI according to the current guidelines (1). Nowadays is expected a progressive increase of TAVI procedures, in relationship to aging and increased life expectancy (2). Percutaneous, particularly trans-femoral, access represents the best choice in the vast majority of TAVI patients, because of its minimal invasiveness and reduced mortality, due to lower rates of periprocedural bleedings and strokes (3,4). Technical advancements, improving expertise and simplification of procedure, lead to reduction of vascular complications, still significant, and linked with worst patients' outcome (5). Some factors are considered to increase the risk of vascular complication: patient related and procedural related factors. Patient-related factors include female gender, severe vascular calcification and peripheral vascular disease. Procedural related risk factors consist of increased sheath to femoral artery ratio (SFAR) and TAVI centre experience/case load (5). Considering the last 10 years progress in techniques, devices technology and clinical outcome, a new Valve Academic Research Consortium (VARC) consensus manuscript was published to provide an update of these emerging clinical and research issues in aortic valve therapy (6).
Arterial stiffness is a physiologic phenomenon occurring with age and involving changes in extracellular matrix components of the arterial wall. Particularly, the elastin fibres undergo proteolytic degradation and chemical alteration, with consequent increased production of collagen, by vascular smooth muscle cells with progressive arterial wall stiffening (7). Arterial stiffness appears to be accelerated under pathological conditions, such as hypertension, smoking, diabetes mellitus (DM) and kidney disease (8), furthermore has been shown to have two-fold higher incidence in women compared to men (9).
Read more
TAVI patients have higher median age and comorbidities, directly correlated with arterial stiffness (7), and female gender is a considered high-risk feature for vascular complication independently from SFAR and atherosclerosis (5).
Arterial stiffness induces progressive reduction of tensile strength, elongation and burst pressure with consequent drop of vessels breakpoint (10), that could be associated with vascular complications. Particularly, femoral artery stiffness could predispose to microlesions formation at TAVI device access, inducing vascular closure devices failure and vascular complications. Furthermore, vessel rigidity can be associated with a higher resistance during TAVI device delivery and increased probability of vessels injury (especially in presence of tortuosity and small artery diameters). Nowadays, there are no studies evaluating the relationship between arterial stiffness and TAVI vascular complications.
The aim of this study is to evaluate the relationship between arterial stiffness and TAVI vascular complications, defining a new predictor of vascular complications in order to give more accurate information for procedures planning.
Read the detailed description
Background Transcatheter aortic valve implantation (TAVI) is an established treatment modality in patients ≥ 75 years old with severe symptomatic aortic stenosis after Heart Team evaluation (1). Patients with high/prohibitive surgical risk and life expectancy ≥ 1 years are candidates for TAVI according to the current guidelines (1). Nowadays is expected a progressive increase of TAVI procedures, in relationship to aging and increased life expectancy (2). Percutaneous, particularly trans-femoral, access represents the best choice in the vast majority of TAVI patients, because of its minimal invasiveness and reduced mortality, due to lower rates of periprocedural bleedings and strokes (3,4). Technical advancements, improving expertise and simplification of procedure, lead to reduction of vascular complications, still significant, and linked with worst patients' outcome (5). Some factors are considered to increase the risk of vascular complication: patient related and procedural related factors. Patient-related factors include female gender, severe vascular calcification and peripheral vascular disease. Procedural related risk factors consist of increased sheath to femoral artery ratio (SFAR) and TAVI centre experience/case load (5). Considering the last 10 years progress in techniques, devices technology and clinical outcome, a new Valve Academic Research Consortium (VARC) consensus manuscript was published to provide an update of these emerging clinical and research issues in aortic valve therapy (6).
Arterial stiffness is a physiologic phenomenon occurring with age and involving changes in extracellular matrix components of the arterial wall. Particularly, the elastin fibres undergo proteolytic degradation and chemical alteration, with consequent increased production of collagen, by vascular smooth muscle cells with progressive arterial wall stiffening (7). Arterial stiffness appears to be accelerated under pathological conditions, such as hypertension, smoking, diabetes mellitus (DM) and kidney disease (8), furthermore has been shown to have two-fold higher incidence in women compared to men (9).
TAVI patients have higher median age and comorbidities, directly correlated with arterial stiffness (7), and female gender is a considered high-risk feature for vascular complication independently from SFAR and atherosclerosis (5).
Arterial stiffness induces progressive reduction of tensile strength, elongation and burst pressure with consequent drop of vessels breakpoint (10), that could be associated with vascular complications. Particularly, femoral artery stiffness could predispose to microlesions formation at TAVI device access, inducing vascular closure devices failure and vascular complications. Furthermore, vessel rigidity can be associated with a higher resistance during TAVI device delivery and increased probability of vessels injury (especially in presence of tortuosity and small artery diameters). Nowadays, there are no studies evaluating the relationship between arterial stiffness and TAVI vascular complications.
Aim The aim of this study is to evaluate the relationship between arterial stiffness and TAVI vascular complications, defining a new predictor of vascular complications in order to give more accurate information for procedures planning.
Endpoints The primary study endpoint is a composite of: any life-threatening, major or minor bleeding complication, or any major or minor vascular access complication according to VARC 3 criteria (6).
The secondary endpoints are: time to hemostasis, procedural length, in hospital/30 day any vascular complications, any bleedings, mortality, stroke/TIA, myocardial infarction and hospitalization, 1 year mortality, stroke/TIA, myocardial infarction, hospitalization and modified VCD failure, which was defined as failure of the VCD to achieve hemostasis within 5 min or requiring additional maneuvers (such as endovascular stenting, surgical techniques, balloon inflation or additional closure devices). 30-day PM implantation and FA insurgence/recurrence were also evaluated.
Methods
- MEASUREMENTS OF ARTERIAL STIFFNESS Systemic and local arterial stiffness can be evaluated by different non-invasive methods. Pulse wave velocity (PWV) is the most widely used, non-invasive and accurate method for aortic stiffness evaluation. PWV is a strong predictor of cardiovascular worse outcome, now considered to be the gold standard arterial stiffness measurement (11,12). However, despite these advantages, PWV does not reflect the degree of arteriosclerosis in the local arterial wall, because it is an indirect measure of regional arterial stiffness and needs a special device scarcely available in hospital centers. To overcome PWV limitations, alternative methods have been proposed, in particular ultrasound methods are a useful tool for this purpose, allowing the direct visualization of the arterial wall, the measurement of blood flow using the Doppler technique and are available in vast majority of hospital centers (13,14).
1a. Echocardiographic Assessment of Aortic Pulse-Wave Velocity
Measurement of echocardiographic pulse wave velocity (PWV) needs the registration of doppler waveforms at two artery sites for the evaluation of transit time. The first acquisition should be in the distal aortic arch (T1:at level of left subclavian artery origin), the second one in the left distal external iliac artery (T2) and then the distance between artery sites should be calculated (D):
T1: time interval between the peak R wave on electrocardiography and the onset of PW Doppler signal of the descending thoracic aorta; T2: time interval between the peak R wave on electrocardiography and the onset of PW Doppler signal of the external iliac artery (EIA).
D: distance from the beginning site of the descending thoracic aorta (T1 evaluation point) to the EIA (T2 evaluation point) will be measured with Angio CT analysis.
Transit time (∆T): calculated as the difference between time from the QRS complex to the beginning of the EIA Doppler waveform (T2) and time from the QRS complex to the beginning of the distal aortic arch Doppler waveform (T1).
PWV: will be calculated as (T2-T1)/(D). Doppler sample volume will be set at 5.07 mm and the low-velocity filter will be reduced to get the beginning of the waveform adjacent to the baseline. 5 consecutive Doppler waveforms were recorded at a sweep speed of 100 mm/sec.
1b. Echocardiographic Assessment of Femoral stiffness
Femoral arterial stiffness indices were calculated according to the following formulas (13,15):
- Arterial diameter change (mm)=SD-DD
- Arterial strain=(SD-DD)/DD
- Elastic modulus E(p)=(SBP-DBP)/strain
- Arterial stiffness index ß=Ln (SBP/DBP)/strain (Ln: natural logarithm)
- Arterial distensibility coefficient =(2×strain)/(SBP-DBP)
SD is systolic arterial diameter, DD is diastolic arterial diameter and SBP and DBP are brachial systolic and diastolic blood pressure, respectively. The use of brachial instead of local blood pressure (BP) may underestimate the predictive value of local stiffness due to BP amplification (i.e., the increase in BP along the arterial tree). The magnitude of amplification, however, tend to reduce with aging (14). Consequently, in elderly populations (13,16), local stiffness indices calculated with brachial or local PP may yield similar results. Stiffness index β, suggested by Hayashi et al. (17) provides a measurement of arterial stiffness independent of blood pressure at the time of measurement within the physiological blood pressure range (63-200 mmHg).
Measurement of femoral artery diameters will be acquired with linear probe only in patients with acceptable common femoral artery acoustic window and undergoing transfemoral-TAVI. M-Mode configuration with beam perpendicular to femoral artery (1 to 3 centimetres proximal from bifurcation) will be used for both SD and DD measurement.
- PATIENTS ENROLLMENT
Consecutive patients will be enrolled before undergoing TAVI procedure:
Inclusion criteria
- Age ≥ 18 years
- Patients eligible for transfemoral TAVI. Exclusion criteria
- Conditions determining inadequate windows for evaluation of pulse wave doppler both at aortic arch and femoral artery level.
- CT scan not performed.
- Planned surgical access.
- DATA COLLECTION AND ANALYSIS Local database will be used for data collection and management. Ultrasound and CT scan acquisitions will be stored and evaluated offline using dedicated software (EchoPAC; GE Healthcare. Horos; Apple) by 2 expert investigators who will be blinded to clinical and laboratory data; in case of discordance, a consensus reading will be achieved with a third senior investigator.
- Being tested
- Transfemoral tranScatheter aortic valvE implantation
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Transfemoral tranScatheter aortic valvE implantationProcedure or surgery
Transcatheter aortic valve implantation (TAVI) is an established treatment modality in patients ≥ 75 years old with severe symptomatic aortic stenosis after Heart Team evaluation
What is being measured
The primary outcome is the main question the study is designed to answer.
The primary study endpoint is a composite of: any life-threatening, major or minor bleeding complication, or any major or minor vascular access complication according to VARC 3 criteria (6).
The primary study endpoint is a composite of: any life-threatening, major or minor bleeding complication, or any major or minor vascular access complication according to VARC 3 criteria (6).
Measured: 12 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted21 Jul 2022
- Study start1 Aug 2022 (estimated)
- Primary completion1 Aug 2023 (estimated)
- Study completion1 Aug 2023 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Transfemoral tranScatheter Aortic valvE ImplantationStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Other
- Time perspective
- Prospective
- Enrolment
- 120 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Dr. Giuseppe Musumeci
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor-investigator, Dr. Giuseppe Musumeci, Azienda Ospedaliera Ordine Mauriziano di Torino
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05468762
- Sponsor's protocol ID
- ULISSE
- Acronym
- ULISSE
- Status last verified
- Jul 2022
- First submitted
- 19 Jul 2022
- Last updated
- 21 Jul 2022
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided
Study at a glance
From the registry record, last updated by the sponsor on 21 Jul 2022. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Ultrasound arteriaL Stiffness evaluatIon and vaScular Complications in Patients Undergoing Transfemoral tranScatheter Aortic valvE Implantation: ULISSE Study.
- ClinicalTrials.gov ID
- NCT05468762
- Acronym / sponsor ID
- ULISSE / ULISSE
- Study type
- Observational
- Recruitment status
- Unknown status
- Enrolment
- 120 participants (estimated)
- Lead sponsor
- Dr. Giuseppe MusumeciUniversity, hospital or other
- Study start
- 1 Aug 2022 (estimated)
- Primary completion
- 1 Aug 2023 (estimated)
- Study completion
- 1 Aug 2023 (estimated)
- First posted
- 21 Jul 2022 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Transcatheter aortic valve implantation (TAVI) is an established treatment modality in patients ≥ 75 years old with severe symptomatic aortic stenosis after Heart Team evaluation (1). Patients with high/prohibitive surgical risk and life expectancy ≥ 1 years are candidates for TAVI according to the current guidelines (1). Nowadays is expected a progressive increase of TAVI procedures, in relationship to aging and increased life expectancy (2). Percutaneous, particularly trans-femoral, access represents the best choice in the vast majority of TAVI patients, because of its minimal invasiveness and reduced mortality, due to lower rates of periprocedural bleedings and strokes (3,4). Technical advancements, improving expertise and simplification of procedure, lead to reduction of vascular complications, still significant, and linked with worst patients' outcome (5). Some factors are considered to increase the risk of vascular complication: patient related and procedural related factors. Patient-related factors include female gender, severe vascular calcification and peripheral vascular disease. Procedural related risk factors consist of increased sheath to femoral artery ratio (SFAR) and TAVI centre experience/case load (5). Considering the last 10 years progress in techniques, devices technology and clinical outcome, a new Valve Academic Research Consortium (VARC) consensus manuscript was published to provide an update of these emerging clinical and research issues in aortic valve therapy (6).
Arterial stiffness is a physiologic phenomenon occurring with age and involving changes in extracellular matrix components of the arterial wall. Particularly, the elastin fibres undergo proteolytic degradation and chemical alteration, with consequent increased production of collagen, by vascular smooth muscle cells with progressive arterial wall stiffening (7). Arterial stiffness appears to be accelerated under pathological conditions, such as hypertension, smoking, diabetes mellitus (DM) and kidney disease (8), furthermore has been shown to have two-fold higher incidence in women compared to men (9).
TAVI patients have higher median age and comorbidities, directly correlated with arterial stiffness (7), and female gender is a considered high-risk feature for vascular complication independently from SFAR and atherosclerosis (5).
Arterial stiffness induces progressive reduction of tensile strength, elongation and burst pressure with consequent drop of vessels breakpoint (10), that could be associated with vascular complications. Particularly, femoral artery stiffness could predispose to microlesions formation at TAVI device access, inducing vascular closure devices failure and vascular complications. Furthermore, vessel rigidity can be associated with a higher resistance during TAVI device delivery and increased probability of vessels injury (especially in presence of tortuosity and small artery diameters). Nowadays, there are no studies evaluating the relationship between arterial stiffness and TAVI vascular complications.
The aim of this study is to evaluate the relationship between arterial stiffness and TAVI vascular complications, defining a new predictor of vascular complications in order to give more accurate information for procedures planning.
Detailed description
Background Transcatheter aortic valve implantation (TAVI) is an established treatment modality in patients ≥ 75 years old with severe symptomatic aortic stenosis after Heart Team evaluation (1). Patients with high/prohibitive surgical risk and life expectancy ≥ 1 years are candidates for TAVI according to the current guidelines (1). Nowadays is expected a progressive increase of TAVI procedures, in relationship to aging and increased life expectancy (2). Percutaneous, particularly trans-femoral, access represents the best choice in the vast majority of TAVI patients, because of its minimal invasiveness and reduced mortality, due to lower rates of periprocedural bleedings and strokes (3,4). Technical advancements, improving expertise and simplification of procedure, lead to reduction of vascular complications, still significant, and linked with worst patients' outcome (5). Some factors are considered to increase the risk of vascular complication: patient related and procedural related factors. Patient-related factors include female gender, severe vascular calcification and peripheral vascular disease. Procedural related risk factors consist of increased sheath to femoral artery ratio (SFAR) and TAVI centre experience/case load (5). Considering the last 10 years progress in techniques, devices technology and clinical outcome, a new Valve Academic Research Consortium (VARC) consensus manuscript was published to provide an update of these emerging clinical and research issues in aortic valve therapy (6).
Arterial stiffness is a physiologic phenomenon occurring with age and involving changes in extracellular matrix components of the arterial wall. Particularly, the elastin fibres undergo proteolytic degradation and chemical alteration, with consequent increased production of collagen, by vascular smooth muscle cells with progressive arterial wall stiffening (7). Arterial stiffness appears to be accelerated under pathological conditions, such as hypertension, smoking, diabetes mellitus (DM) and kidney disease (8), furthermore has been shown to have two-fold higher incidence in women compared to men (9).
TAVI patients have higher median age and comorbidities, directly correlated with arterial stiffness (7), and female gender is a considered high-risk feature for vascular complication independently from SFAR and atherosclerosis (5).
Arterial stiffness induces progressive reduction of tensile strength, elongation and burst pressure with consequent drop of vessels breakpoint (10), that could be associated with vascular complications. Particularly, femoral artery stiffness could predispose to microlesions formation at TAVI device access, inducing vascular closure devices failure and vascular complications. Furthermore, vessel rigidity can be associated with a higher resistance during TAVI device delivery and increased probability of vessels injury (especially in presence of tortuosity and small artery diameters). Nowadays, there are no studies evaluating the relationship between arterial stiffness and TAVI vascular complications.
Aim The aim of this study is to evaluate the relationship between arterial stiffness and TAVI vascular complications, defining a new predictor of vascular complications in order to give more accurate information for procedures planning.
Endpoints The primary study endpoint is a composite of: any life-threatening, major or minor bleeding complication, or any major or minor vascular access complication according to VARC 3 criteria (6).
The secondary endpoints are: time to hemostasis, procedural length, in hospital/30 day any vascular complications, any bleedings, mortality, stroke/TIA, myocardial infarction and hospitalization, 1 year mortality, stroke/TIA, myocardial infarction, hospitalization and modified VCD failure, which was defined as failure of the VCD to achieve hemostasis within 5 min or requiring additional maneuvers (such as endovascular stenting, surgical techniques, balloon inflation or additional closure devices). 30-day PM implantation and FA insurgence/recurrence were also evaluated.
Methods
- MEASUREMENTS OF ARTERIAL STIFFNESS Systemic and local arterial stiffness can be evaluated by different non-invasive methods. Pulse wave velocity (PWV) is the most widely used, non-invasive and accurate method for aortic stiffness evaluation. PWV is a strong predictor of cardiovascular worse outcome, now considered to be the gold standard arterial stiffness measurement (11,12). However, despite these advantages, PWV does not reflect the degree of arteriosclerosis in the local arterial wall, because it is an indirect measure of regional arterial stiffness and needs a special device scarcely available in hospital centers. To overcome PWV limitations, alternative methods have been proposed, in particular ultrasound methods are a useful tool for this purpose, allowing the direct visualization of the arterial wall, the measurement of blood flow using the Doppler technique and are available in vast majority of hospital centers (13,14).
1a. Echocardiographic Assessment of Aortic Pulse-Wave Velocity
Measurement of echocardiographic pulse wave velocity (PWV) needs the registration of doppler waveforms at two artery sites for the evaluation of transit time. The first acquisition should be in the distal aortic arch (T1:at level of left subclavian artery origin), the second one in the left distal external iliac artery (T2) and then the distance between artery sites should be calculated (D):
T1: time interval between the peak R wave on electrocardiography and the onset of PW Doppler signal of the descending thoracic aorta; T2: time interval between the peak R wave on electrocardiography and the onset of PW Doppler signal of the external iliac artery (EIA).
D: distance from the beginning site of the descending thoracic aorta (T1 evaluation point) to the EIA (T2 evaluation point) will be measured with Angio CT analysis.
Transit time (∆T): calculated as the difference between time from the QRS complex to the beginning of the EIA Doppler waveform (T2) and time from the QRS complex to the beginning of the distal aortic arch Doppler waveform (T1).
PWV: will be calculated as (T2-T1)/(D). Doppler sample volume will be set at 5.07 mm and the low-velocity filter will be reduced to get the beginning of the waveform adjacent to the baseline. 5 consecutive Doppler waveforms were recorded at a sweep speed of 100 mm/sec.
1b. Echocardiographic Assessment of Femoral stiffness
Femoral arterial stiffness indices were calculated according to the following formulas (13,15):
- Arterial diameter change (mm)=SD-DD
- Arterial strain=(SD-DD)/DD
- Elastic modulus E(p)=(SBP-DBP)/strain
- Arterial stiffness index ß=Ln (SBP/DBP)/strain (Ln: natural logarithm)
- Arterial distensibility coefficient =(2×strain)/(SBP-DBP)
SD is systolic arterial diameter, DD is diastolic arterial diameter and SBP and DBP are brachial systolic and diastolic blood pressure, respectively. The use of brachial instead of local blood pressure (BP) may underestimate the predictive value of local stiffness due to BP amplification (i.e., the increase in BP along the arterial tree). The magnitude of amplification, however, tend to reduce with aging (14). Consequently, in elderly populations (13,16), local stiffness indices calculated with brachial or local PP may yield similar results. Stiffness index β, suggested by Hayashi et al. (17) provides a measurement of arterial stiffness independent of blood pressure at the time of measurement within the physiological blood pressure range (63-200 mmHg).
Measurement of femoral artery diameters will be acquired with linear probe only in patients with acceptable common femoral artery acoustic window and undergoing transfemoral-TAVI. M-Mode configuration with beam perpendicular to femoral artery (1 to 3 centimetres proximal from bifurcation) will be used for both SD and DD measurement.
- PATIENTS ENROLLMENT
Consecutive patients will be enrolled before undergoing TAVI procedure:
Inclusion criteria
- Age ≥ 18 years
- Patients eligible for transfemoral TAVI. Exclusion criteria
- Conditions determining inadequate windows for evaluation of pulse wave doppler both at aortic arch and femoral artery level.
- CT scan not performed.
- Planned surgical access.
- DATA COLLECTION AND ANALYSIS Local database will be used for data collection and management. Ultrasound and CT scan acquisitions will be stored and evaluated offline using dedicated software (EchoPAC; GE Healthcare. Horos; Apple) by 2 expert investigators who will be blinded to clinical and laboratory data; in case of discordance, a consensus reading will be achieved with a third senior investigator.
Study design
- Observational model
- Other
- Time perspective
- Prospective
Who may qualify
- Ages
- 75 years and older
- Sex
- All
- Age groups
- Older adult
- Study population
- patients ≥ 75 years old with severe symptomatic aortic stenosis after Heart Team evaluation
Key inclusion criteria (2 listed)
- Age ≥ 18 years
- Patients eligible for transfemoral TAVI.
Key exclusion criteria (3 listed)
- Conditions determining inadequate windows for evaluation of pulse wave doppler both at aortic arch and femoral artery level.
- CT scan not performed.
- Planned surgical access.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Transfemoral tranScatheter aortic valvE implantationTranscatheter aortic valve implantation (TAVI) is an established treatment modality in patients ≥ 75 years old with severe symptomatic aortic stenosis after Heart Team evaluation | Procedure or surgery | – |
Primary outcome
The primary study endpoint is a composite of: any life-threatening, major or minor bleeding complication, or any major or minor vascular access complication according to VARC 3 criteria (6).
Time frame: 12 months
The primary study endpoint is a composite of: any life-threatening, major or minor bleeding complication, or any major or minor vascular access complication according to VARC 3 criteria (6).
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 21 Jul 2022.
- Individual participant dataSharing planned: Undecided
Related trials for Transfemoral tranScatheter Aortic valvE Implantation
Recruiting
Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR
Aortic Stenosis Treated With TAVI, Aortic Diseases
Active, not recruiting
JOURNEY LVAD: JOURNEY Left Ventricular Assist Device
Aortic Valve Regurgitation, Aortic Valve Disease Mixed
Active, not recruiting
J-Valve Transfemoral Pivotal Study
Aortic Valve Regurgitation, Aortic Valve Disease Mixed
Recruiting
Low-dose Colchicine for Thromboprophylaxis After Transcatheter Aortic Valve Replacement
Transcatheter Aortic Valve Replacement, Transcatheter Heart Valve Thrombosis
Recruiting
Staged Complete Revascularization for Coronary Artery Disease vs Medical Management Alone in Patients With AS Undergoing Transcatheter Aortic Valve Replacement
Aortic Stenosis, Coronary Artery Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Transfemoral tranScatheter Aortic valvE Implantation, run by Dr. Giuseppe Musumeci at 1 site in Italy.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 21 Jul 2022. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Each site lists its own contact: choose the nearest one under Trial locations. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
The primary study endpoint is a composite of: any life-threatening, major or minor bleeding complication, or any major or minor vascular access complication according to VARC 3 criteria (6). (time frame: 12 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 21 Jul 2022.