OligohydramniosNCT05474326

Effect of Intermittent Pneumatic Compression Device of Lower Limbs in Oligohydramnios

A study testing intermittent pneumatic pressure device (Kendall SCD™ 700 Smart Compression™ System) in people with Oligohydramnios and Amniotic Fluid; Disorder, run by Western Galilee Hospital-Nahariya.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

the study will examine the effect of application of intermittent pneumatic pressure device on lower limbs on the amniotic fluid amount and fetal doppler indices in women with oligohydramnios Read more about this study

Who is it for?
Ages 18 years and older, women onlyHealthy volunteers can take part
Conditions the study is for
Oligohydramnios, Amniotic Fluid; Disorder
What is being tested?
intermittent pneumatic pressure device (Kendall SCD™ 700 Smart Compression™ System)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
No sites listed yet
Study dates
15 Aug 2022to 31 Dec 2023
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • Women only
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • pregnant women with a diagnosis of oligohydramnios

Who cannot join

  • fetal malformation
  • rupture of membranes
  • documented viral infection with rubella, cytomegalovirus, herpes simplex, toxoplsma in pregnancy

Trial locations and contacts

No sites are listed yet.

Inshirah Sgayer, MD contact

0508890662

inshirah.sg.sh@gmail.com

About this study

Official title: Amniotic Fluid Index and Fetal Doppler Indices Measurment After Application of Intermittent Pneumatic Compression Device on Lower Limbs in Pregnant Women With Oligohydramnios

the study will examine the effect of application of intermittent pneumatic pressure device on lower limbs on the amniotic fluid amount and fetal doppler indices in women with oligohydramnios

Read the detailed description

oligohydramnios is diagnosed based on ultrasonographic finding of amniotic fluid index less than 5 cm.

Etiologies of oligohydramnios includes infection with viruses such as rubella, cytomegalo virus or parasites such as toxoplasma. other etiologies includes rupture of membranes or fetal malformatios especially urinary tract anomalies. in addition, placental insuffiency may lead to oligohydramnios and can be diagnosed through abnormal doppler measures in the umbilical and middle cereberal arteries. when these etiologies are excluded oligohydramnios is considered to be idiopathic.

The Kendall SCD™ 700 Smart Compression™ Controller is an intermittent pneumatic compression (IPC) device which delivers compression to the legs and feet to aid in the prevention of Venous Thromboembolism in at-risk patient.

previous studies had shown that intermittent pneumatic compression device may increase cardiac output through preload increase.

the study hypothesis that after the application of IPC there will be an improvement in the preload and cardiac which will lead to an increase in placental perfusion and eventually will lead to increase in amniotic fluid amount and improvement in fetal doppler measurement.

the study will include women with a diagnosis of idiopathic oligohydramnios between 32-41 weeks and who will agree to participate in the study the diagnosis of idiopathic oligohydramnios is based on ultrasonographic diagnosis of amniotic fluid index of less than 5 cm after exclusion of other etiologies.

The amniotic fluid index (AFI) is measured by dividing the uterus into four imaginary quadrants. The linea nigra is used to divide the uterus into right and left halves.The umbilicus serves as the dividing point for the upper and lower halves.

The transducer is kept parallel to the patient's longitudinal axis and perpendicular to the floor. The deepest, unobstructed, vertical pocket of fluid is measured in each quadrant in centimeters. The four pocket measurements are then added to calculate the AFI. Normal AFI values range from 5 to 25 cm. women with AFI<5 cm will be diagnosed with oligohydramnios.

The amniotic fluid fluid index (AFI) will be measured in centemeters before the application of IPC the IPC device will be applied to the lower limbs for one hour after this a repeated measurement of AFI in centemeters will be performed.

additionally, doppler studies will be performed. Pulsed wave high-resolution color doppler uhrasonography will be used to identify and to obtain blood flow velocity waveforms from the following vessels: (1) umbilical artery, from a free loop of theumbilical cord; (2) middle cerebral artery, from the main vessel identified branching from the circle of Willis at the anterior wing of the sphenoid; (3) renal artery, from the vessel identified branching from the abdominal aorta into the hilum of the kidney, and (4) maternal uterine artery, from the vessel branching from the internal iliac artery on the placental side.

In all vessels the pulsatility index will be calculated with the mean of at least three consecutive waveforms used for analysis.

Being tested
intermittent pneumatic pressure device (Kendall SCD™ 700 Smart Compression™ System)
Medical subject headings
Oligohydramnios

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • intermittent pneumatic pressure device (Kendall SCD™ 700 Smart Compression™ System)Device

    application of intermittent pneumatic pressure device (Kendall SCD™ 700 Smart Compression™ System) on lower limbs and its effect on fetal and maternal doppler and amniotic fluid index in women with oligohydramnios. the compression system will be applicated on lower limbs for one hour in which it will produce intermittent compression on lower limbs. amniotic fluid amnout assessment will be done after this including doppler studies in order to detect any change in amniotic fluid amount or dopper.

Study groups in NCT05474326
Study groupRoleWhat they receive
pregnant women with idiopathic oligohydramniosExperimentalwomen with singleton pregnancy between 32-41 weeks oligohydramnios diagnosed by ultrasound by the amniotic fluid index (AFI) method oligohydramnios is diagnosed if AFI index is less than 5 cm
Receives: Device: intermittent pneumatic pressure device (Kendall SCD™ 700 Smart Compression™ System)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. pulsatility index in maternal uterine artery

    Pulsed wave high-resolution color Doppler uhrasonography will be used to identify and to obtain blood flow velocity waveforms. PI will be calculated from the difference in the systolic and diastolic flow velocity divided by the mean flow velocity baseline PI of the maternal uterine artery will be calculated before the application of IPC on lower maternal limbs PI of the maternal uterine artery will be re-calculated after the application of IPC on lower maternal limbs for one hour

    Measured: one hour

  2. pulsatility index in fetal umbilical artery

    Pulsed wave high-resolution color Doppler uhrasonography will be used to identify and to obtain blood flow velocity waveforms. PI will be calculated from the difference in the systolic and diastolic flow velocity divided by the mean flow velocity baseline PI of the fetal umbilical artery will be calculated before the application of IPC on lower maternal limbs PI of the fetal umbilical artery will be re-calculated after the application of IPC on lower maternal limbs for one hour

    Measured: one hour

  3. pulsatility index in fetal middle cerebral artery

    Pulsed wave high-resolution color Doppler uhrasonography will be used to identify and to obtain blood flow velocity waveforms. PI will be calculated from the difference in the systolic and diastolic flow velocity divided by the mean flow velocity baseline PI of the fetal middle cerebral artery will be calculated before the application of IPC on lower maternal limbs PI of the fetal middle cerebral artery will be re-calculated after the application of IPC on lower maternal limbs for one hour

    Measured: one hour

  4. pulsatility index in fetal renal artery

    Pulsed wave high-resolution color Doppler uhrasonography will be used to identify and to obtain blood flow velocity waveforms. PI will be calculated from the difference in the systolic and diastolic flow velocity divided by the mean flow velocity baseline PI of the fetal renal artery will be calculated before the application of IPC on lower maternal limbs PI of the fetal renal artery will be re-calculated after the application of IPC on lower maternal limbs for one hour

    Measured: one hour

  5. amniotic fluid index

    basline amniotic fluid index (AFI in centemeters) will be calculated before the application of IPC on lower maternal limbs amniotic fluid index (AFI in centemeters) will be re-calculated after the application of IPC on lower maternal limbs for one hour

    Measured: one hour

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted26 Jul 2022
  2. Study start15 Aug 2022 (estimated)
  3. Primary completion1 Dec 2023 (estimated)
  4. Study completion31 Dec 2023 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Model description
The Kendall SCD™ 700 Smart Compression™ Controller is an intermittent pneumatic compression (IPC) device application of this intermittent pneumatic pressure device on lower limbs in women with oligohydramnios and its effect on maternal uterine artery doppler, fetal umbilical artery doppler, middle cerebral artery doppler
Masking
None (open label)
Enrolment
30 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05474326
Sponsor's protocol ID
9999
Status last verified
Jul 2022
First submitted
7 Dec 2021
Last updated
26 Jul 2022
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes

Questions about this trial

What is this clinical trial studying?

A study testing intermittent pneumatic pressure device (Kendall SCD™ 700 Smart Compression™ System) in people with Oligohydramnios and Amniotic Fluid; Disorder, run by Western Galilee Hospital-Nahariya.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 26 Jul 2022. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Inshirah Sgayer, MD (0508890662, inshirah.sg.sh@gmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

pulsatility index in maternal uterine artery (time frame: one hour). The study lists 5 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 26 Jul 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in