AzTrials
AzTrials

OutcomesNCT05494632

Interaural Frequency and Loudness Mismatch in SSD CI Users

A study testing Treatment-modifications to CI speech processor program. Specifically reducing interaural frequency mismatch in experienced SSD-CI recipients., Treatment-modifications to CI speech processor program to reduced interaural frequency mismatch in newly implanted SSD-CI recipients. and Treatment-modifications to CI speech processor program to reduced interaural loudness mismatch in experienced SSD-CI recipients. in people with Outcomes, run by Washington University School of Medicine at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Interaural loudness and pitch mismatch in single-sided deaf cochlear implant (SSD-CI) recipients reduces binaural processing cues and contributes to performance outcomes, specifically speech understanding in noise and localization. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Outcomes
What is being tested?
Treatment-modifications to CI speech processor program. Specifically reducing interaural frequency mismatch in experienced SSD-CI recipients., Treatment-modifications to CI speech processor program to reduced interaural frequency mismatch in newly implanted SSD-CI recipients. and Treatment-modifications to CI speech processor program to reduced interaural loudness mismatch in experienced SSD-CI recipients.
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
45 participants
Where
1 siteUnited States
Study dates
12 Aug 2022to 1 Aug 2025
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Participants for the proposed study will be adults with single-sided deafness. Participants will have at least 6 months experience with their cochlear implant or will be newly implanted with the cochlear implant.
  • Inclusion criteria for the experienced CI user group and the newly implant group are as follows:
  • 18 years of age and older
  • Postlingual onset of SSD
  • Pure tone average (PTA) at 500, 1000, and 2000 Hz of less than or equal to 30 dB HL in the contralateral ear, known as the normal hearing ear
  • Implanted with or chosen to be implanted with a Nucleus cochlear implant
  • Full insertion of electrode array

Who cannot join

  • • Not meeting the inclusion criteria

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Washington University School of Medicine

    St Louis, Missouri, 63110

Other trials in United States

About this study

Official title: Effects of Interaural Frequency and Loudness Mismatch on SSD-CI Performance

Interaural loudness and pitch mismatch in single-sided deaf cochlear implant (SSD-CI) recipients reduces binaural processing cues and contributes to performance outcomes, specifically speech understanding in noise and localization. The study aims to improve binaural cues through speech processor program modifications that reduce interaural mismatches.

Read the detailed description

Effective binaural processing depends on similar loudness growth functions at each ear. The use of interaural level differences (ILDs), perceived as loudness differences, to locate sound is critical given the inability of cochlear implant (CI) recipients to use interaural time differences (ITDs) in binaural processing. In CI recipients with single-sided deafness (SSD), perceived interaural loudness differences may not be valid indicators of interaural level differences because the CI compresses amplitude. Studies suggest better preservation of ILDs may contribute to improved localization and understanding in noise. Since SSD-CI recipients use only one device, an approach to improve their use of ILDs is to match perceived loudness at each ear.

Binaural processing is also affected when signals of equal frequency are not matched in pitch at each ear. In bilateral CI recipients, the investigators found that the greater the pitch mismatch between ears, the poorer the speech understanding in noise. The investigators want to extend this work to SSD-CI recipients. Through CI program modifications, the study aims to decrease the pitch and loudness mismatch between the CI ear and the normal hearing ear to improve binaural listening abilities, specifically speech understanding in noise and sound localization.

Conditions
Outcomes
Being tested
Treatment-modifications to CI speech processor program. Specifically reducing interaural frequency mismatch in experienced SSD-CI recipients., Treatment-modifications to CI speech processor program to reduced interaural frequency mismatch in newly implanted SSD-CI recipients., Treatment-modifications to CI speech processor program to reduced interaural loudness mismatch in experienced SSD-CI recipients.

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Treatment-modifications to CI speech processor program. Specifically reducing interaural frequency mismatch in experienced SSD-CI recipients.Device

    We will modify the CI speech processor program to reduce interaural frequency mismatch between the CI ear and the contralateral ear in experienced CI recipients with SSD.

  • Treatment-modifications to CI speech processor program to reduced interaural frequency mismatch in newly implanted SSD-CI recipients.Device

    We will modify the CI speech processor program to reduce interaural frequency mismatch between the CI ear and the contralateral ear in newly implanted CI recipients with SSD.

  • Treatment-modifications to CI speech processor program to reduced interaural loudness mismatch in experienced SSD-CI recipients.Device

    We will modify the CI speech processor program to reduce interaural loudness mismatch between the CI ear and the contralateral ear in experienced CI recipients with SSD.

Study groups in NCT05494632
Study groupRoleWhat they receive
Period 1: Study 1ExperimentalCI speech processor programming in experienced cochlear implant (CI) recipients with single sided deafness. Program changes were made to decrease the interaural frequency mismatch between the CI ear and the contralateral ear.
Receives: Device: Treatment-modifications to CI speech processor program. Specifically reducing interaural frequency mismatch in experienced SSD-CI recipients.
Period 2: Study 2ExperimentalCI speech processor programming in newly implanted cochlear implant (CI) recipients with single sided deafness. Program changes were made to decrease the interaural frequency mismatch between the CI ear and the contralateral ear.
Receives: Device: Treatment-modifications to CI speech processor program to reduced interaural frequency mismatch in newly implanted SSD-CI recipients.
Period 3: study 3ExperimentalCI speech processor programming in experienced cochlear implant (CI) recipients with single sided deafness. Program changes were made to decrease the interaural loudness mismatch between the CI ear and the contralateral ear.
Receives: Device: Treatment-modifications to CI speech processor program to reduced interaural loudness mismatch in experienced SSD-CI recipients.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Speech Understanding in Noise, Measured With the R-Space Test Environment. The R-Space Test Environment Simulates Speech Understanding in a Noisy Restaurant.

    Participants speech understanding was evaluated in the R-Space test environment with two speech processor programs, an everyday or default program and a modified program. The modified program was created to reduce interaural frequency or loudness mismatch between participants' CI ear and normal hearing ear. The R-Space simulates listening in a noisy restaurant, a real-world listening situation. The score is a signal-to-noise ratio that reflects 50% speech understanding in noise. Participants are surrounded by 8 loudspeakers with restaurant noise from all 8. A sentence is presented from the front loudspeaker. Participants repeat back what they hear. The noise is adjusted adaptively. For a correct response, the noise is increased; it is decreased for an incorrect response. This provides signal-to-noise ratio (SNR) for 50% speech understanding. The average score for participants with normal hearing is -5 dB SNR. A lower number represents better performance than a higher number.

    Measured: Participants were tested in the R-Space twice with each speech processor program, e.g., everyday or default program and modified program. The testing was carried out within a 2-3 month time period, and after using each program for at least 6 weeks.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted10 Aug 2022
  2. Study start12 Aug 2022
  3. Primary completion30 Jul 2024
  4. Study completion1 Aug 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Non-randomised
Intervention model
Single group
Masking
None (open label)
Enrolment
45 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05494632
Sponsor's protocol ID
202206085
Status last verified
Mar 2026
First submitted
8 Aug 2022
Last updated
23 Mar 2026
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes

Questions about this trial

What is this clinical trial studying?

A study testing Treatment-modifications to CI speech processor program. Specifically reducing interaural frequency mismatch in experienced SSD-CI recipients., Treatment-modifications to CI speech processor program to reduced interaural frequency mismatch in newly implanted SSD-CI recipients. and Treatment-modifications to CI speech processor program to reduced interaural loudness mismatch in experienced SSD-CI recipients. in people with Outcomes, run by Washington University School of Medicine at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 7 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 23 Mar 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 1 Jul 2025). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Speech Understanding in Noise, Measured With the R-Space Test Environment. The R-Space Test Environment Simulates Speech Understanding in a Noisy Restaurant. (time frame: Participants were tested in the R-Space twice with each speech processor program, e.g., everyday or default program and modified program. The testing was carried out within a 2-3 month time period, and after using each program for at least 6 weeks.). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 23 Mar 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in