Colorectal CancerNCT05514301
Clinical Validation of Polydeep: an Artificial Intelligence-based Computer-aided Polyp Detection (CADe) and Characterization (CADx) System
A study testing Sensitivity of Polydeep vs high experienced endoscopists for colorectal polyp detection in people with Colorectal Cancer, run by Fundacin Biomedica Galicia Sur at 1 site in Spain.
Trial summary
This study is a clinical validation of Polydeep, a computer-aided polyp detection (CADe) and characterization (CADx) system. Polydeep Advance 1 is an unicentric prospective diagnostic tests trial with a paired study design. Read more about this study
- Who is it for?
- Ages 40 to 79 years
- Conditions the study is for
- Colorectal Cancer
- What is being tested?
- Sensitivity of Polydeep vs high experienced endoscopists for colorectal polyp detection
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 205 participants
- Where
- 1 siteSpain
- Study dates
- 30 Jan 2023to 11 Apr 2023
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 40 to 79 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- First diagnostic colonoscopy performed after a positive fecal immunochemical test performed within the CRC screening program.
- Surveillance after resection of colorectal adenomas.
- Acceptance after reading the information sheet and signing the informed consent
Who cannot join
- Colonoscopies with insufficient intestinal cleansing (Boston Bowel Preparation Scale <6 or <2 in any of the evaluated segments).
- Detected lesions without histologic diagnosis.
- Previous CRC
- Previous colonic resection
- Hereditary CRC syndromes
- Serrated polyposis syndrome
- Incomplete colonoscopy without cecal intubation.
Trial locations and contacts
1 site in 1 country.
Spain1 site
Complexo Hospitalario Universitario de Ourense
Ourense, Ourense, 32002
About this study
Official title: Polydeep Advance I: Prospective Diagnostic Tests Trial with a Paired Study Design
This study is a clinical validation of Polydeep, a computer-aided polyp detection (CADe) and characterization (CADx) system. Polydeep Advance 1 is an unicentric prospective diagnostic tests trial with a paired study design. The hypothesis of the study is that Polydeep, a CAD system, is more sensitive than a blinded endoscopists for the detection of colorectal polyps in a high definition colonoscopy.
Read the detailed description
Colorectal cancer (CRC) is the most frequently cancer in western world. A fundamental tool for detection and prevention is the colonoscopy. The detection and endoscopic resection of colorectal polyps, the precursor lesion of CRC can reduce CRC incidence and mortality. Adenoma detection rate is the most used endoscopic quality indicator. The improvement of this indicator is related to the reduction of postcolonoscopy CRC incidence and mortality.
Colorectal polyp diagnosis is based on endoscopic resection and histological analysis. An accurate optical diagnosis could avoid histological lesion of smaller lesions, reducing the costs associated with histological diagnosis. The NICE international classification has proposed the use of high definition endoscopes that have Narrow Band Imaging. However, NICE must be used by endoscopists who are sufficiently prepared and who have overcome the learning curve. Therefore, optical histology diagnosis with high accuracy independently of the center and the endoscopist is necessary.
Computer Aid Diagnosis (CAD) systems based on Artificial Intelligence are experiencing exponential development in the field of medical image analysis. The development of the CAD system is based on the creation of large databases of endoscopic images and/or videos, on the training, development and validation of diagnostic algorithms in such databases and, finally, on prospective clinical validation in patients undergoing colonoscopy. The goal of CAD systems in colonoscopy is double. First, it aims to increase the detection of polyps (CADe) in general, and of adenomas and serrated lesions in particular. The second objective is to characterize (CADx) the histology of detected lesion.
Polydeep CAD is a functional prototype. It is capable of detecting, locating and classifying colorectal polyps. In vivo validation data shows that Polydeep has high diagnostic accuracy for polyp identification and that this accuracy can be accommodated. The aim of Polydeep advance 1 is to perform the clinical validation within a diagnostic test trial with a paired study design. We will compare the sensitivity of Polydeep to endoscopists blinded to Polydeep in high definition colonoscopy.
- Conditions
- Colorectal Cancer
- Being tested
- Sensitivity of Polydeep vs high experienced endoscopists for colorectal polyp detection
- Keywords
- Colorectal adenomas, Colorectal polyps, Serrated lesions, Computer-Aided detection System (CAD)
- Medical subject headings
- Colorectal Neoplasms
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Sensitivity of Polydeep vs high experienced endoscopists for colorectal polyp detectionDiagnostic test
Both diagnostic interventions will be performed in all patients
- High definition colonoscopy performed by high experienced endoscopists blinded to Polydeep.
- Polydeep: a CADe and CADx system. The gold standard will be the histological diagnosis of the lesion.
| Study group | Role | What they receive |
|---|---|---|
| Sensitivity of Polydeep vs high experienced endoscopists for colorectal polyp detection | Experimental | Both diagnostic interventions will be performed in all patients: High definition colonoscopy and Polydeep system. Receives: Diagnostic Test: Sensitivity of Polydeep vs high experienced endoscopists for colorectal polyp detection |
What is being measured
The primary outcome is the main question the study is designed to answer.
Sensitivity of polydeep vs high experienced endoscopist blinded to polydeep
To compare the sensitivity of Polydeep to a high experienced endoscopist for colorectal polyp detection (adenoma or serrated lesion histologically confirmed)
Measured: 1 year
Secondary outcomes (5)
Sensitivity for serrated lesions detection.
To compare the sensitivity of Polydeep to a high experienced endoscopist for serrated lesions detection
Measured: 1 year
Sensitivity for adenoma detection.
To compare the sensitivity of Polydeep to a high experienced endoscopist for adenoma detection
Measured: 1 year
Sensitivity for advanced colonic lesions
To compare the sensitivity of Polydeep to a high experienced endoscopist for advanced colonic lesions (serrated lesions ≥10mm and/or dysplasia, adenoma ≥10mm and/or villous histology and/or high grade dysplasia) detection
Measured: 1 year
Sensitivity for diminute lesions (≤5mm)
To compare the sensitivity of Polydeep to a high experienced endoscopist for diminute lesions (≤5mm) detection
Measured: 1 year
To compare the diagnostic yield of the optical diagnosis
To compare diagnostic yield of optic diagnostic of polydeep to high experienced endoscopists.
Measured: 1 year
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted24 Aug 2022
- Study start30 Jan 2023
- Primary completion15 Mar 2023
- Study completion11 Apr 2023
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (11)Papers the sponsor has linked to this study.
- Other trials for Colorectal CancerStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- A high definition colonoscopy will be performed by a high experienced endoscopists. The endoscopists will be blinded to a second monitor with the Polydeep evaluation. A second observer will annotate the lesions detected during colonoscopy withdrawal and will inform the endoscopists if Polydeep detects a lesion that is not detected by the endoscopists.
- Masking
- None (open label)
- Enrolment
- 205 participants (actual)
Sponsor and investigators
- Lead sponsor
- Fundacin Biomedica Galicia Sur
- Sponsor type
- University, hospital or other
- Collaborators
- Ministerio de Ciencia e Innovación, Spain, Ministry of Work and Welfare - Xunta de Galicia, Asociación Española de Gastroenterología, European Regional Development Fund
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05514301
- Sponsor's protocol ID
- PolyDeep Advance 1.0
- Status last verified
- May 2022
- First submitted
- 22 Aug 2022
- Last updated
- 24 Feb 2025
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Cubiella J, Marzo-Castillejo M, Mascort-Roca JJ, Amador-Romero FJ, Bellas-Beceiro B, Clofent-Vilaplana J, Carballal S, Ferrandiz-Santos J, Gimeno-Garcia AZ, Jover R, Mangas-Sanjuan C, Moreira L, Pellise M, Quintero E, Rodriguez-Camacho E, Vega-Villaamil P; Sociedad Espanola de Medicina de Familia y Comunitaria y Asociacion Espanola de Gastroenterologia. Clinical practice guideline. Diagnosis and prevention of colorectal cancer. 2018 Update. Gastroenterol Hepatol. 2018 Nov;41(9):585-596. doi: 10.1016/j.gastrohep.2018.07.012. Epub 2018 Sep 20. English, Spanish.
PubMed 30245076Corley DA, Jensen CD, Marks AR, Zhao WK, Lee JK, Doubeni CA, Zauber AG, de Boer J, Fireman BH, Schottinger JE, Quinn VP, Ghai NR, Levin TR, Quesenberry CP. Adenoma detection rate and risk of colorectal cancer and death. N Engl J Med. 2014 Apr 3;370(14):1298-306. doi: 10.1056/NEJMoa1309086.
PubMed 24693890Zhao S, Wang S, Pan P, Xia T, Chang X, Yang X, Guo L, Meng Q, Yang F, Qian W, Xu Z, Wang Y, Wang Z, Gu L, Wang R, Jia F, Yao J, Li Z, Bai Y. Magnitude, Risk Factors, and Factors Associated With Adenoma Miss Rate of Tandem Colonoscopy: A Systematic Review and Meta-analysis. Gastroenterology. 2019 May;156(6):1661-1674.e11. doi: 10.1053/j.gastro.2019.01.260. Epub 2019 Feb 6.
PubMed 30738046ASGE Technology Committee; Abu Dayyeh BK, Thosani N, Konda V, Wallace MB, Rex DK, Chauhan SS, Hwang JH, Komanduri S, Manfredi M, Maple JT, Murad FM, Siddiqui UD, Banerjee S. ASGE Technology Committee systematic review and meta-analysis assessing the ASGE PIVI thresholds for adopting real-time endoscopic assessment of the histology of diminutive colorectal polyps. Gastrointest Endosc. 2015 Mar;81(3):502.e1-502.e16. doi: 10.1016/j.gie.2014.12.022. Epub 2015 Jan 16.
PubMed 25597420Puig I, Lopez-Ceron M, Arnau A, Rosinol O, Cuatrecasas M, Herreros-de-Tejada A, Ferrandez A, Serra-Burriel M, Nogales O, Vida F, de Castro L, Lopez-Vicente J, Vega P, Alvarez-Gonzalez MA, Gonzalez-Santiago J, Hernandez-Conde M, Diez-Redondo P, Rivero-Sanchez L, Gimeno-Garcia AZ, Burgos A, Garcia-Alonso FJ, Bustamante-Balen M, Martinez-Bauer E, Penas B, Pellise M; EndoCAR group, Spanish Gastroenterological Association and the Spanish Digestive Endoscopy Society. Accuracy of the Narrow-Band Imaging International Colorectal Endoscopic Classification System in Identification of Deep Invasion in Colorectal Polyps. Gastroenterology. 2019 Jan;156(1):75-87. doi: 10.1053/j.gastro.2018.10.004. Epub 2018 Oct 6.
PubMed 30296432Jin EH, Lee D, Bae JH, Kang HY, Kwak MS, Seo JY, Yang JI, Yang SY, Lim SH, Yim JY, Lim JH, Chung GE, Chung SJ, Choi JM, Han YM, Kang SJ, Lee J, Chan Kim H, Kim JS. Improved Accuracy in Optical Diagnosis of Colorectal Polyps Using Convolutional Neural Networks with Visual Explanations. Gastroenterology. 2020 Jun;158(8):2169-2179.e8. doi: 10.1053/j.gastro.2020.02.036. Epub 2020 Feb 29.
PubMed 32119927Hassan C, Spadaccini M, Iannone A, Maselli R, Jovani M, Chandrasekar VT, Antonelli G, Yu H, Areia M, Dinis-Ribeiro M, Bhandari P, Sharma P, Rex DK, Rosch T, Wallace M, Repici A. Performance of artificial intelligence in colonoscopy for adenoma and polyp detection: a systematic review and meta-analysis. Gastrointest Endosc. 2021 Jan;93(1):77-85.e6. doi: 10.1016/j.gie.2020.06.059. Epub 2020 Jun 26.
PubMed 32598963Parmar R, Martel M, Rostom A, Barkun AN. Validated Scales for Colon Cleansing: A Systematic Review. Am J Gastroenterol. 2016 Feb;111(2):197-204; quiz 205. doi: 10.1038/ajg.2015.417. Epub 2016 Jan 19.
PubMed 26782820Parsa N, Rex DK, Byrne MF. Colorectal polyp characterization with standard endoscopy: Will Artificial Intelligence succeed where human eyes failed? Best Pract Res Clin Gastroenterol. 2021 Jun-Aug;52-53:101736. doi: 10.1016/j.bpg.2021.101736. Epub 2021 Feb 22.
PubMed 34172255Wani S, Rastogi A. Narrow-band imaging in the prediction of submucosal invasive colon cancer: how "NICE" is it? Gastrointest Endosc. 2013 Oct;78(4):633-6. doi: 10.1016/j.gie.2013.06.015. No abstract available.
PubMed 24054741Mangas-Sanjuan C, Santana E, Cubiella J, Rodriguez-Camacho E, Seoane A, Alvarez-Gonzalez MA, Suarez A, Alvarez-Garcia V, Gonzalez N, Lue A, Cid-Gomez L, Ponce M, Bujanda L, Portillo I, Pellise M, Diez-Redondo P, Herraiz M, Ono A, Pizarro A, Zapater P, Jover R; QUALISCOPIA Study Investigators. Variation in Colonoscopy Performance Measures According to Procedure Indication. Clin Gastroenterol Hepatol. 2020 May;18(5):1216-1223.e2. doi: 10.1016/j.cgh.2019.08.035. Epub 2019 Aug 22.
PubMed 31446179
Study at a glance
From the registry record, last updated by the sponsor on 24 Feb 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Polydeep Advance I: Prospective Diagnostic Tests Trial with a Paired Study Design
- ClinicalTrials.gov ID
- NCT05514301
- Acronym / sponsor ID
- PolyDeep Advance 1.0
- Conditions
- Colorectal Cancer
- Keywords
- Colorectal adenomas, Colorectal polyps, Serrated lesions, Computer-Aided detection System (CAD)
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 205 participants (actual)
- Lead sponsor
- Fundacin Biomedica Galicia SurUniversity, hospital or other
- Collaborators
- Ministerio de Ciencia e Innovación, Spain, Ministry of Work and Welfare - Xunta de Galicia, Asociación Española de Gastroenterología, European Regional Development Fund
- Study start
- 30 Jan 2023 (actual)
- Primary completion
- 15 Mar 2023 (actual)
- Study completion
- 11 Apr 2023 (actual)
- First posted
- 24 Aug 2022 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study is a clinical validation of Polydeep, a computer-aided polyp detection (CADe) and characterization (CADx) system. Polydeep Advance 1 is an unicentric prospective diagnostic tests trial with a paired study design. The hypothesis of the study is that Polydeep, a CAD system, is more sensitive than a blinded endoscopists for the detection of colorectal polyps in a high definition colonoscopy.
Detailed description
Colorectal cancer (CRC) is the most frequently cancer in western world. A fundamental tool for detection and prevention is the colonoscopy. The detection and endoscopic resection of colorectal polyps, the precursor lesion of CRC can reduce CRC incidence and mortality. Adenoma detection rate is the most used endoscopic quality indicator. The improvement of this indicator is related to the reduction of postcolonoscopy CRC incidence and mortality.
Colorectal polyp diagnosis is based on endoscopic resection and histological analysis. An accurate optical diagnosis could avoid histological lesion of smaller lesions, reducing the costs associated with histological diagnosis. The NICE international classification has proposed the use of high definition endoscopes that have Narrow Band Imaging. However, NICE must be used by endoscopists who are sufficiently prepared and who have overcome the learning curve. Therefore, optical histology diagnosis with high accuracy independently of the center and the endoscopist is necessary.
Computer Aid Diagnosis (CAD) systems based on Artificial Intelligence are experiencing exponential development in the field of medical image analysis. The development of the CAD system is based on the creation of large databases of endoscopic images and/or videos, on the training, development and validation of diagnostic algorithms in such databases and, finally, on prospective clinical validation in patients undergoing colonoscopy. The goal of CAD systems in colonoscopy is double. First, it aims to increase the detection of polyps (CADe) in general, and of adenomas and serrated lesions in particular. The second objective is to characterize (CADx) the histology of detected lesion.
Polydeep CAD is a functional prototype. It is capable of detecting, locating and classifying colorectal polyps. In vivo validation data shows that Polydeep has high diagnostic accuracy for polyp identification and that this accuracy can be accommodated. The aim of Polydeep advance 1 is to perform the clinical validation within a diagnostic test trial with a paired study design. We will compare the sensitivity of Polydeep to endoscopists blinded to Polydeep in high definition colonoscopy.
Study design
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- A high definition colonoscopy will be performed by a high experienced endoscopists. The endoscopists will be blinded to a second monitor with the Polydeep evaluation. A second observer will annotate the lesions detected during colonoscopy withdrawal and will inform the endoscopists if Polydeep detects a lesion that is not detected by the endoscopists.
| Arm | Type | Receives |
|---|---|---|
| Sensitivity of Polydeep vs high experienced endoscopists for colorectal polyp detection | Experimental | Diagnostic Test: Sensitivity of Polydeep vs high experienced endoscopists for colorectal polyp detectionBoth diagnostic interventions will be performed in all patients: High definition colonoscopy and Polydeep system. |
Who may qualify
- Ages
- 40 to 79 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- First diagnostic colonoscopy performed after a positive fecal immunochemical test performed within the CRC screening program.
- Surveillance after resection of colorectal adenomas.
- Acceptance after reading the information sheet and signing the informed consent
Key exclusion criteria (7 listed)
- Colonoscopies with insufficient intestinal cleansing (Boston Bowel Preparation Scale <6 or <2 in any of the evaluated segments).
- Detected lesions without histologic diagnosis.
- Previous CRC
- Previous colonic resection
- Hereditary CRC syndromes
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Sensitivity of Polydeep vs high experienced endoscopists for colorectal polyp detectionBoth diagnostic interventions will be performed in all patients 1. High definition colonoscopy performed by high experienced endoscopists blinded to Polydeep. 2. Polydeep: a CADe and CADx system. The gold standard will be the histological diagnosis of the lesion. | Diagnostic test | Sensitivity of Polydeep vs high experienced endoscopists for colorectal polyp detection |
Primary outcome
Sensitivity of polydeep vs high experienced endoscopist blinded to polydeep
Time frame: 1 year
To compare the sensitivity of Polydeep to a high experienced endoscopist for colorectal polyp detection (adenoma or serrated lesion histologically confirmed)
5 secondary outcomes
Sensitivity for serrated lesions detection.
Time frame: 1 year
Sensitivity for adenoma detection.
Time frame: 1 year
Sensitivity for advanced colonic lesions
Time frame: 1 year
Sensitivity for diminute lesions (≤5mm)
Time frame: 1 year
To compare the diagnostic yield of the optical diagnosis
Time frame: 1 year
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 24 Feb 2025.
- Background: PubMed 30245076Cubiella J, Marzo-Castillejo M, Mascort-Roca JJ, Amador-Romero FJ, Bellas-Beceiro B, Clofent-Vilaplana J, Carballal S, Ferrandiz-Santos J, Gimeno-Garcia AZ, Jover R, Mangas-Sanjuan C, Moreira L, Pellise M, Quintero E, Rodriguez-Camacho E, Vega-Villaamil P; Sociedad Espanola de Medicina de Familia y Comunitaria y Asociacion Espanola de Gastroenterologia. Clinical practice guideline. Diagnosis and prevention of colorectal cancer. 2018 Update. Gastroenterol Hepatol. 2018 Nov;41(9):585-596. doi: 10.1016/j.gastrohep.2018.07.012. Epub 2018 Sep 20. English, Spanish.
- Background: PubMed 24693890Corley DA, Jensen CD, Marks AR, Zhao WK, Lee JK, Doubeni CA, Zauber AG, de Boer J, Fireman BH, Schottinger JE, Quinn VP, Ghai NR, Levin TR, Quesenberry CP. Adenoma detection rate and risk of colorectal cancer and death. N Engl J Med. 2014 Apr 3;370(14):1298-306. doi: 10.1056/NEJMoa1309086.
- Background: PubMed 30738046Zhao S, Wang S, Pan P, Xia T, Chang X, Yang X, Guo L, Meng Q, Yang F, Qian W, Xu Z, Wang Y, Wang Z, Gu L, Wang R, Jia F, Yao J, Li Z, Bai Y. Magnitude, Risk Factors, and Factors Associated With Adenoma Miss Rate of Tandem Colonoscopy: A Systematic Review and Meta-analysis. Gastroenterology. 2019 May;156(6):1661-1674.e11. doi: 10.1053/j.gastro.2019.01.260. Epub 2019 Feb 6.
- Background: PubMed 25597420ASGE Technology Committee; Abu Dayyeh BK, Thosani N, Konda V, Wallace MB, Rex DK, Chauhan SS, Hwang JH, Komanduri S, Manfredi M, Maple JT, Murad FM, Siddiqui UD, Banerjee S. ASGE Technology Committee systematic review and meta-analysis assessing the ASGE PIVI thresholds for adopting real-time endoscopic assessment of the histology of diminutive colorectal polyps. Gastrointest Endosc. 2015 Mar;81(3):502.e1-502.e16. doi: 10.1016/j.gie.2014.12.022. Epub 2015 Jan 16.
- Background: PubMed 30296432Puig I, Lopez-Ceron M, Arnau A, Rosinol O, Cuatrecasas M, Herreros-de-Tejada A, Ferrandez A, Serra-Burriel M, Nogales O, Vida F, de Castro L, Lopez-Vicente J, Vega P, Alvarez-Gonzalez MA, Gonzalez-Santiago J, Hernandez-Conde M, Diez-Redondo P, Rivero-Sanchez L, Gimeno-Garcia AZ, Burgos A, Garcia-Alonso FJ, Bustamante-Balen M, Martinez-Bauer E, Penas B, Pellise M; EndoCAR group, Spanish Gastroenterological Association and the Spanish Digestive Endoscopy Society. Accuracy of the Narrow-Band Imaging International Colorectal Endoscopic Classification System in Identification of Deep Invasion in Colorectal Polyps. Gastroenterology. 2019 Jan;156(1):75-87. doi: 10.1053/j.gastro.2018.10.004. Epub 2018 Oct 6.
- Background: PubMed 32119927Jin EH, Lee D, Bae JH, Kang HY, Kwak MS, Seo JY, Yang JI, Yang SY, Lim SH, Yim JY, Lim JH, Chung GE, Chung SJ, Choi JM, Han YM, Kang SJ, Lee J, Chan Kim H, Kim JS. Improved Accuracy in Optical Diagnosis of Colorectal Polyps Using Convolutional Neural Networks with Visual Explanations. Gastroenterology. 2020 Jun;158(8):2169-2179.e8. doi: 10.1053/j.gastro.2020.02.036. Epub 2020 Feb 29.
- Background: PubMed 32598963Hassan C, Spadaccini M, Iannone A, Maselli R, Jovani M, Chandrasekar VT, Antonelli G, Yu H, Areia M, Dinis-Ribeiro M, Bhandari P, Sharma P, Rex DK, Rosch T, Wallace M, Repici A. Performance of artificial intelligence in colonoscopy for adenoma and polyp detection: a systematic review and meta-analysis. Gastrointest Endosc. 2021 Jan;93(1):77-85.e6. doi: 10.1016/j.gie.2020.06.059. Epub 2020 Jun 26.
- Background: PubMed 26782820Parmar R, Martel M, Rostom A, Barkun AN. Validated Scales for Colon Cleansing: A Systematic Review. Am J Gastroenterol. 2016 Feb;111(2):197-204; quiz 205. doi: 10.1038/ajg.2015.417. Epub 2016 Jan 19.
- Background: PubMed 34172255Parsa N, Rex DK, Byrne MF. Colorectal polyp characterization with standard endoscopy: Will Artificial Intelligence succeed where human eyes failed? Best Pract Res Clin Gastroenterol. 2021 Jun-Aug;52-53:101736. doi: 10.1016/j.bpg.2021.101736. Epub 2021 Feb 22.
- Background: PubMed 24054741Wani S, Rastogi A. Narrow-band imaging in the prediction of submucosal invasive colon cancer: how "NICE" is it? Gastrointest Endosc. 2013 Oct;78(4):633-6. doi: 10.1016/j.gie.2013.06.015. No abstract available.
- Background: PubMed 31446179Mangas-Sanjuan C, Santana E, Cubiella J, Rodriguez-Camacho E, Seoane A, Alvarez-Gonzalez MA, Suarez A, Alvarez-Garcia V, Gonzalez N, Lue A, Cid-Gomez L, Ponce M, Bujanda L, Portillo I, Pellise M, Diez-Redondo P, Herraiz M, Ono A, Pizarro A, Zapater P, Jover R; QUALISCOPIA Study Investigators. Variation in Colonoscopy Performance Measures According to Procedure Indication. Clin Gastroenterol Hepatol. 2020 May;18(5):1216-1223.e2. doi: 10.1016/j.cgh.2019.08.035. Epub 2019 Aug 22.
- Polydeep websiteLink provided by the sponsor.
- 43th congress of digestive endoscopy spanish societyLink provided by the sponsor.
- Effect of a deep-learning computer-aided detection system on adenoma detection during colonoscopy (CADe-DB trial): a double-blind randomised study.Link provided by the sponsor.
- Individual participant dataSharing planned: No
Related trials for Colorectal Cancer
RecruitingObservational study
Evaluation for NCI Surgery Branch Clinical Research Protocols
Synovial Cell Cancer, Melanoma
RecruitingObservational study
Obtaining Solid Tumor Tissue From People Having Biopsy or Surgery for Certain Types of Cancer
Colorectal Neoplasms, Gastric Neoplasms
Active, not recruitingPhase 2
Targeted Therapy Directed by Genetic Testing in Treating Patients With Advanced Refractory Solid Tumors, Lymphomas, or Multiple Myeloma (The MATCH Screening Trial)
Advanced Lymphoma, Advanced Malignant Solid Neoplasm
Active, not recruitingPhase 3
Combination Chemotherapy With or Without Atezolizumab in Treating Patients With Stage III Colon Cancer and Deficient DNA Mismatch Repair
Colon Adenocarcinoma, DNA Repair Disorder
Active, not recruitingPhase 3
Testing the Addition of Atezolizumab to Combination Chemotherapy or Atezolizumab Alone for Metastatic Colon or Rectal Cancer, the COMMIT Study
Metastatic Colorectal Adenocarcinoma, Stage IV Colorectal Cancer AJCC v7
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Sensitivity of Polydeep vs high experienced endoscopists for colorectal polyp detection in people with Colorectal Cancer, run by Fundacin Biomedica Galicia Sur at 1 site in Spain.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 24 Feb 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Spain. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Sensitivity of polydeep vs high experienced endoscopist blinded to polydeep (time frame: 1 year). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT05514301, which also lists 11 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Feb 2025; AzTrials last refreshed its copy on 27 Oct 2026.