AzTrials
AzTrials

Cardiopulmonary Exercise TestNCT05520307

Validity of SeismoFit VO2max Estimation in Patients With Heart Failure or Ischemic Heart Disease

An observational study of Cardiopulmonary Exercise Test, run by University of Copenhagen at 1 site in Denmark.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Measurement of cardiorespiratory fitness (VO2max) is considered an important tool in risk prediction of cardiovascular disease and overall patient management. The gold standard method for determining VO2max is a maximal cardiopulmonary exercise test (CPET). Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Cardiopulmonary Exercise Test
How many people
180 participants
Where
1 siteDenmark
Study dates
16 Dec 2023to 31 Aug 2024
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Adult, Older adult

Study population: Patients with heart failure: HFrEF (LVEF < 40%) and NYHA I-III. And Patients with Ischemic heart disease

Who may be able to join

  • Fulfilling the guidelines for rehabilitation sat out by the Danish Society of Cardiology.
  • Approved for exercise testing on a cycle ergometer by a specialized doctor in cardiology.

Who cannot join

  • Absolute contraindications with training
  • Conditions that prevent maximal exercise testing assess by a specialized doctor in cardiology.

Trial locations and contacts

1 site in 1 country.

Jørn W Helge, Professor contact

+45 28757506

jhelge@sund.ku.dk

Denmark1 site, 1 recruiting
  • Herlev and Gentofte Hospital

    Gentofte Municipality, 2900

    Morten Lamberts, MD, PhD, morten.kjoebek.lamberts@regionh.dk

    Recruiting

Other trials in Denmark

About this study

Measurement of cardiorespiratory fitness (VO2max) is considered an important tool in risk prediction of cardiovascular disease and overall patient management. The gold standard method for determining VO2max is a maximal cardiopulmonary exercise test (CPET). This requires time, maximal exercise until voluntary exhaustion and expensive equipment and are therefor not always suitable. A non-exercise VO2max prediction model using seismocardiography (SCG) at rest in combination with demographic data has been proposed as an possible alternative. SCG is a non-invasive three-dimensional measurement technique of precordial vibrations caused by the beating heart and can provide information on cardiac performance. New advances in low-weight three-axis accelerometer, signal processing and feature selection has made this methodology attractive in the recent years. VentriJect Aps has develop a medical device for measuring SCG (SeismoFit) together with an cloud solution for signal processing and prediction of VO2max. The validity of the SeismoFit device has previously been assesses in healthy subjects, but not yet in patients.

The aim of this study is therefore to investigate the validity of the SeismoFit VO2max estimation in patients with heart failure (HF) or ischemic heart disease (IHD).

Read the detailed description

The study is composed of three parts in order to investigate the validity and reliability of the SeimsoFit VO2max estimation.

  1. A cross-sectional part: 80 patients with HF and 60 patients with IHD are recruited for this part. An interim data analysis is planed after 50% of the patients have been through testing, in order to allow for algorithm adjustment, before the data analysis of the last 50% are performed. This part requires one test day.
  2. A longitudinal part: 60 patients with HF and 40 patients with IHD are recruited to perform a follow-up test (from part 1) after being medical customized to the treatment doses. This is typically within 3-4 month, depending on the patient.

This part requires one follow-up test day in addition to the test in part 1.

  1. A test-retest part: 20 HF and 20 IHD patients are recruited for this part. This part requires one test day within 2-7 days after the last test in part 2.

The testing procedures are identical for the different study parts and includes:

  • Measurement of weight and height.
  • Estimation of VO2max with the SeismoFit device at supine rest. The SeismoFit device is patented by the company VentriJect Aps and it contains a three-axis accelerometer and a 3-v battery. The SeismoFit is attached to the lower part of the sternum with double adhesive tape. The SCG recording takes 40 seconds and signal process takes approximately one to two minutes depending on the internet connection. The algorithm uses SCG information and weight, height, age and sex.
  • A direct measurement of VO2max applying a graded exercise test until voluntary exhaustion with continuous pulmonary gas exchange measurements. The protocol will be customized for the different patients. However, a starting workload of 50 Watt with 25 Watt increments every 2 minutes are the standard protocol used. The patients will be monitored with ECG and blood pressure measurements during the test. Directly following termination of the test, the patients will rate their perceived exertion on the Borg 6-20 scale.

Data from echocardiography measurement and blood samples performed during the standard care treatment at the hospital will be available in this study.

Statistical analysis:

All data will be checked for normal distribution (Shapiro-Wilk test) and equal variance (Brown-Forsythe test). The significant level is p<0.05.

Validity assessment of the SeismoFit VO2max estimation compared with the CPET measured VO2max for HF and IHD patients will be analysed with; A Student's paired t-test or a mixed effect model (part 2), Pearson correlation coefficient r, Standard Error of Estimate (SEE), Mean Absolute Percentage Error (MAPE), Coefficient of Variation (CV%) and Bland-Altman analysis with 95% limits of agreement (BA-plot). Pearson r interpretation is: very high > 0.90, high 0.70-0.90, moderate 0.50-0.70, low 0.30-0.50 and little if any 0.00-0.30. SEE is calculated using: =√(Y-Y')/n-2, with Y representing CPET VO2max and Y' representing SeismoFit VO2max. SEE interpretation is: very good < 4.0 ml/min/kg, good 4.0-6.0 ml/min/kg, fair 6.0-8.0 ml/min/kg, poor 8.0-10.0 ml/min/kg and > 10.0 ml/min/kg very poor. A MAPE ≤ 10% will be used as a criteria level for the SeismoFit VO2max estimation to be considered clinically relevant.

Reliability assessment is analysed with a mixed-effect model, within-subject standard deviation, CV% and Pearson r. The within-subject standard deviation is calculated taking the squared root of the within-subject variance. Statistical analyses will be performed, and figures constructed in R Studio, GraphPad Prism and Microsoft Excel.

Keywords
SeismoFit, CPET, Heart Failure, VO2max assessment, Ischemic heart disease, Seismocardiography
Medical subject headings
Heart Failure, Myocardial Ischemia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

Study groups in NCT05520307
Study groupRoleWhat they receive
HFPatients with heart failure.
IHDPatients with ischemic heart disease.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Validity of SeismoFit VO2max estimation in HF and IHD patients

    Assessment of VO2max at rest with SeismoFit and with a gold standard CPET.

    The validity of the SeismoFit will be based on difference and agreement between the two test methods for both hart failure patients and patients with ischemic heart disease.

    Measured: 1 day

Secondary outcomes (2)
  1. Detection of change in VO2max using SeismoFit

    A follow-up test day after meeting the medical treatment doses in order to investigate if the SeismoFit is able to detect changes in VO2max following medical treatment and physical rehabilitation in these patient groups.

    The validity of SeismoFit will be based on difference and agreement between pre and post standard medical treatment compared with CPET.

    Measured: 4-5 month

  2. Reliability of the SeimoFit VO2max estimation

    A test day performed within 2-7 days after the follow-up test day in order to assess reliability of the SeismoFit estimation.

    The reliability will be based on intra-method variation between the two test days.

    Measured: 7 days

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Aug 2022
  2. Study start16 Dec 2023
  3. Primary completion1 Apr 2024 (estimated)
  4. Study completion31 Aug 2024 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Cross-sectional
Enrolment
180 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05520307
Sponsor's protocol ID
VentriJect Gentofte Study
Status last verified
Jan 2024
First submitted
25 Aug 2022
Last updated
17 Jan 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Hansen MT, Hashiba M, Nielsen SK, Petersen CS, Saederup RG, Schmidt SE, Wolsk E, Helge JW, Lamberts M. Non-exercise estimation of peak oxygen uptake in patients with ischaemic heart disease and heart failure using seismocardiography. Eur Heart J Digit Health. 2025 Sep 2;7(1):ztaf095. doi: 10.1093/ehjdh/ztaf095. eCollection 2026 Jan.

    PubMed 41574039

Questions about this trial

What is this clinical trial studying?

An observational study of Cardiopulmonary Exercise Test, run by University of Copenhagen at 1 site in Denmark.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 17 Jan 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Denmark. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Jørn W Helge, Professor (+45 28757506, jhelge@sund.ku.dk), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Validity of SeismoFit VO2max estimation in HF and IHD patients (time frame: 1 day). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05520307, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Jan 2024.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in
Clinical Trial NCT05520307 | AzTrials