Trial summary

Introduction: One major complaint frequently voiced by complete denture wearers is denture retention. Conventional denture disadvantage is heat-curing resin deformation. In addition, the pack and press technique that is still more common, residual stresses that occur at the time of packing are released when the… Read more about this study

Who is it for?
Ages 50 to 65 years
Conditions the study is for
Completely Edentulous Patients
What is being tested?
two different denture manufacturing technique (heat cure pack and press technique(heat cure acrylic,Acrostone,Egypt)/3d printed dneture(HARZ lab,Russia))
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
1 siteEgypt
Study dates
1 Aug 2021to 1 Aug 2022
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 50 to 65 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients with good neuromuscular control and free of systemic diseases
  • the edentulous ridge was covered with healthy firm and dense mucosa
  • They have upper and lower edentulous healthy alveolar ridges with no remaining roots, no severe bony undercut, or local pathological lesions.
  • patients had no previous dentures with a nearly equal edentulous period.

Who cannot join

  • history of bad habits e.g. severe clenching.
  • T.M.J disorders
  • patients with xerostomia, high palatal vault, and short or hyperactive lips were excluded.

Trial locations and contacts

1 site in 1 country.

Egypt1 site
  • Faculty of Dentistry,Suez Canal University

    Bilbeis, Sharqia Province, 46213

Other trials in Egypt

About this study

Official title: Three Dimensional Printed Versus Conventional Heat Cured Acrylic Complete Denture: An In-Vivo Comparative Study

Introduction:

One major complaint frequently voiced by complete denture wearers is denture retention. Conventional denture disadvantage is heat-curing resin deformation. In addition, the pack and press technique that is still more common, residual stresses that occur at the time of packing are released when the material is removed from the flask, causing the resin to shrink, and this shrinkage is cited as a cause of poor fit of the denture base, In the field of prosthetic dentistry, the ability of additive manufacturing to fabricate prosthetic devices based on CAD data influences the overall quality, the mechanical properties of printed parts, the total cost and the manufacturing time. The milling process wastes large quantities of denture base material, and more recent three-dimensional (3D) prototyping promises a more sustainable additive approach by using less denture resin. However, no clinical reports have been published regarding the accuracy of the mucosal surface or denture retention for denture fabricated using conventional techniques compared to those fabricated using additive manufacturing.

Read more

Aim of the study:

Investigate the effect of two techniques of complete denture manufacturing (conventional and 3D printed) on denture retention, trueness (accuracy), and satisfaction.

Methodology:

Twenty patients will be selected from the outpatient clinic and will be divided into 2 groups, group A for conventional dentures and group B for 3D printed dentures, retention for the two groups will be measured at 0,1 and 3 months, and patient satisfaction will be recorded, and accuracy of the denture base will be measured on the software. The results will be tabulated and statistically analyzed using the SPSS program.

Read the detailed description

Twenty patients will be selected from the Faculty of Dentistry (Suez Canal University) outpatient clinics with the following criteria:

  • Patients with good neuromuscular control and free of systemic diseases
  • Well-formed ridges with firm and healthy mucosa and no bilateral anterior undercuts.

The patients will be divided equally into two groups(n=10), group (A) which will receive conventional heat cure acrylic denture, and group (B) which will receive 3D printed denture.

Methodology:

A primary impression will be taken for each patient and a special self-cured acrylic tray will be fabricated.

Zinc oxide secondary impression (caves outline, Cavex Holland)will be taken for each patient. The impression will be poured with extra hard stone and labeled master cast.

The cast will be scanned and saved in standard tessellation language (stl) format (master cats).

Jaw relation records for each patient will be taken in the conventional method. For group A: the setting up of teeth will be done in a conventional way on the articulator, and flasking of the waxed-up denture will be done. Wax elimination will be done then packing of heat cure acrylic will be done.

For group B: occlusion block will be scanned (swing scanner, DOF inc, Korea)(the scanner has an accuracy of 10 μm) after taking jaw relation record.

Virtual teeth form, size, and setting will be done on the CAD software (Exocad Dental CAD 3.0, Exocad GmbH, Germany) according to jaw relation record.

The denture base extension and thickness will be designed on CAD software. The teeth will be exported in a separate file and the denture base will be exported in a separate stl file.

The virtual denture stl files will be sent to the 3D printer software (Chitubox software, CBD-Tech, china) where slicing of the file and adjustment of layers setting will be done.

The virtual denture will be sent to the 3D printer (photon 3d printer, ANYCUBIC 3D Printing, china) to be printed (printer has Y axis resolution: 1.25um and Layer resolution: 25 ~ 100um), Teeth will be printed alone using tooth-colored resin(dental sand, Harz labs, Russia) and base will be printed alone using pink resin(dental pink, HArzz lab, Russia), then it will be ethyl alcohol washed (99% ethyl alcohol) to remove excess resin. The teeth will be placed in their places in the denture base and secured using pink resin.

Post-curing for remaining uncured resin will be done using a post-curing chamber for 30 minutes (bre-lux power unit 2,bredent, united kingdom).

Regarding the maxillary denture:

Retention will be measured clinically by using a force gauge (weihang electronic gauge,weihang industries, china) for group A and group B at 0,1 and 3 months. A force gauge will be applied by fixing the chain at the center of the polished surface of the denture. The pull end of the force gauge will be connected to the denture to measure the retention. The force gauge will pull the denture vertically downward until denture retention will be lost, and the denture will move vertically. The force at which the denture dislodges will be recorded in grams. The pull-off procedure will be repeated 10 times to obtain 10 records for each elder, and then the mean of these records will be calculated.

Participants will answer a denture satisfaction questionnaire. Possible answers for each question and respective scores will be: unsatisfactory =0, regular =1, and good =2 (Rehmann et al., 2008) For group, A and group B denture base will be checked for accuracy of fit after scanning using a bench scanner with 1.3 megapixels dual camera and 10-micron accuracy (swing scanner, DOF inc, Korea) and will be compared to the virtual one planned on the master cast using metrology software (Geomagic Control X,3D systems, Canada). This will be done by the superimposition of the scanned printed or processed denture and the virtual reference denture. This will be done by selecting a point-to-point match and then the best fit function.

Color maps of the surface matching differences will be done. Areas that will be yellow to red in color will indicate impingement of the denture base with the cast. Areas that will be blue in color will indicate space between the denture base and cast. The ideal denture will show a color map that will be entirely green, giving a measurement value of 0, which will represent no processing deformation and an ideal adaptation of the denture base to the cast.

The results will be tabulated and statistically analyzed using SPSS Statistics Version 20 for Windows (SPSS, Inc., an IBM Company, USA).

Being tested
two different denture manufacturing technique (heat cure pack and press technique(heat cure acrylic,Acrostone,Egypt)/3d printed dneture(HARZ lab,Russia))
Keywords
3d printing, CAD-CAM, retention, adaptation, denture

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • two different denture manufacturing technique (heat cure pack and press technique(heat cure acrylic,Acrostone,Egypt)/3d printed dneture(HARZ lab,Russia))Device

    retention for the two groups will be measured at 0,1 and 3months, patient satisfaction will be recorded, and accuracy of the denture base will be measured on the software.

Study groups in NCT05585008
Study groupRoleWhat they receive
group AActive comparatorgroup A will receive a conventional heat-cure acrylic denture
Receives: Device: two different denture manufacturing technique (heat cure pack and press technique(heat cure acrylic,Acrostone,Egypt)/3d printed dneture(HARZ lab,Russia))
group BActive comparatorgroup B will receive a 3D printed complete denture
Receives: Device: two different denture manufacturing technique (heat cure pack and press technique(heat cure acrylic,Acrostone,Egypt)/3d printed dneture(HARZ lab,Russia))

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. accuracy of fit (adaptation)

    the deviation of the denture fiitng surface from its corresponding cast will be measured using metrology software (GOM inspect,USA))

    Measured: 1 week

  2. retention

    retention will be measured using digital force gauge(weihang electronic gauge,weihang industries, china)

    Measured: 3 months

  3. patient satisfaction

    Participants will answer a denture satisfaction questionnaire. Possible answers for each question and respective scores will be: unsatisfactory =0, regular =1, and good =2 (Rehmann et al., 2008)

    Measured: 3 months

Secondary outcomes (1)
  1. retention over time period

    change in denture retention over time period(0,1 and 3 months from denture insertion) will be measured for each group

    Measured: 3 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted18 Oct 2022
  2. Study start1 Aug 2021
  3. Primary completion1 May 2022
  4. Study completion1 Aug 2022

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Outcomes assessor
Enrolment
20 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05585008
Sponsor's protocol ID
318/2021
Status last verified
Nov 2022
First submitted
12 Oct 2022
Last updated
8 Nov 2022
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes

Publications

  • Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques. J Prosthet Dent. 2016 Aug;116(2):249-56. doi: 10.1016/j.prosdent.2016.02.017. Epub 2016 Apr 23.

    PubMed 27112416

Questions about this trial

What is this clinical trial studying?

A study testing two different denture manufacturing technique (heat cure pack and press technique(heat cure acrylic,Acrostone,Egypt)/3d printed dneture(HARZ lab,Russia)) in people with Completely Edentulous Patients, run by Suez Canal University at 1 site in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 8 Nov 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

accuracy of fit (adaptation) (time frame: 1 week). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05585008, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Nov 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in