AzTrials
AzTrials

Pulmonary EmbolismNCT05592444

Strategies to Reduce Contrast Medium in Spectral CT Pulmonary Angiography

A study testing Low iodine Spectral Detector CT Pulmonary Angiography in people with Pulmonary Embolism, run by University Hospital, Akershus at 1 site in Norway.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this study is to assess the effect of three different strategies to inject at reduced volume of contrast medium in Computed Tomography Pulmonary Angiography (CTPA). 330 patients referred for CTPA are randomized to receive either a low-concentration, a low-volume or a saline-diluted injection. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Pulmonary Embolism
What is being tested?
Low iodine Spectral Detector CT Pulmonary Angiography
Could I receive a placebo?
No, everyone receives an active treatment
How many people
330 participants
Where
1 siteNorway
Study dates
23 Nov 2020to 12 Oct 2021
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Inpatients and outpatients with kidney function (eGFR) allowing for safe administration of contrast dose (as calculated with the OmniVis calculator).
  • Patients with clinical suspicion of disease of PE
  • Referral to CTPA diagnosis, treatment planning or follow-up.
  • Peripheral venous catheter (PVC) =/< 18 G

Who cannot join

  • Contraindication to iodinated contrast medium
  • Age < 18 years
  • Lack of informed consent
  • Pregnancy

Trial locations and contacts

1 site in 1 country.

Norway1 site
  • Akershus University Hospital

    Lørenskog, Akershus, 1478

Other trials in Norway

About this study

Official title: Different Strategies to Reduce Contrast Medium in Computed Tomography Pulmonary Angiography Using Spectral Detector CT

The purpose of this study is to assess the effect of three different strategies to inject at reduced volume of contrast medium in Computed Tomography Pulmonary Angiography (CTPA).

330 patients referred for CTPA are randomized to receive either a low-concentration, a low-volume or a saline-diluted injection.

Effects on the level and homogeneity of contrast enhancement are measured and compared between groups.

Read the detailed description

Spectral detector CT facilitates large reductions in contrast medium in vascular CT examinations. To our knowledge, no studies have so far compared different strategies to inject this reduced contrast dose.

The purpose of this study is to assess the effect of three different strategies to inject at reduced volume of contrast medium in Computed Tomography Pulmonary Angiography (CTPA).

330 patients referred for clinically indicated CTPA are randomized to receive either a low-concentration, a low-volume or a saline-diluted injection. All patients receive the same amount of iodine (140 mg/kg).

Effects on the level and homogeneity of contrast enhancement, image noise, contrast-to-noise-ratio and signal-to-noise-ratio are measured in the CT images and the results are compared between groups.

Being tested
Low iodine Spectral Detector CT Pulmonary Angiography
Keywords
Pulmonary Embolism, Spectral Detector CT, Contrast medium
Medical subject headings
Pulmonary Embolism

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Low iodine Spectral Detector CT Pulmonary AngiographyDiagnostic test

    Low iodine Spectral Detector CT Pulmonary Angiography

Study groups in NCT05592444
Study groupRoleWhat they receive
Low concentrationExperimentalPatients receive a contrast medium with an iodine concentration of 140 mg/ml. The volume is 1 ml/kg which result in a dose of 140 mg/kg. Maximal dose of contrast medium is 90 ml i.e. 12.6 g of iodine.
Receives: Diagnostic Test: Low iodine Spectral Detector CT Pulmonary Angiography
Low volumeExperimentalPatients receive a contrast medium with an iodine concentration 350 of mg/ml. The volume is 0.4 ml/kg which result in a dose of 140 mg/kg. Maximal dose of contrast medium is 36 ml i.e. 12.6 g of iodine.
Receives: Diagnostic Test: Low iodine Spectral Detector CT Pulmonary Angiography
Saline DilutionExperimentalPatients receive a contrast medium with an iodine concentration of 350 mg/ml. The contrast medium is diluted 1:1 with saline. The injected volume is 0.8 ml/kg which result in a dose of 140 mg/kg. Maximal dose of contrast medium is 72 ml i.e. 12.6 g of iodine.
Receives: Diagnostic Test: Low iodine Spectral Detector CT Pulmonary Angiography

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Contrast enhancement (Vascular attenuation)

    Contrast enhancement measured as attenuation in the pulmonary artery Branches on the acquired CTPA examination

    Measured: Measured on the CT images from the examination performed at enrollment

Secondary outcomes (3)
  1. Homogeneity of contrast enhancement (image noise)

    Homogeneity of contrast enhancement is measured as the standard deviation of attenuation in the pulmonary artery branches (equals image noise).

    Measured: Measured on the CT images from the examination performed at enrollment

  2. Contrast to noise ratio (CNR)

    CNR is measured as (Vascular attenuation - Muscular attenuation) / Image noise

    Measured: Measured on the CT images from the examination performed at enrollment

  3. Signal to noise ratio (SNR)

    SNR is measured as Vascular attenuation / Image noise

    Measured: Measured on the CT images from the examination performed at enrollment

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted24 Oct 2022
  2. Study start23 Nov 2020
  3. Primary completion12 Oct 2021
  4. Study completion12 Oct 2021

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Parallel groups
Model description
Patients are randomly assigned to one of three injection methods: low concentration, low-volume and saline-dilution.
Masking
Triple blind
Who is masked
Participant, Investigator, Outcomes assessor
Enrolment
330 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05592444
Sponsor's protocol ID
142126
Status last verified
Apr 2024
First submitted
20 Oct 2022
Last updated
16 Apr 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Low iodine Spectral Detector CT Pulmonary Angiography in people with Pulmonary Embolism, run by University Hospital, Akershus at 1 site in Norway.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 16 Apr 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Norway. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Contrast enhancement (Vascular attenuation) (time frame: Measured on the CT images from the examination performed at enrollment). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 16 Apr 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in