Abdominal Aortic AneurysmGIBSNCT05607277
Global Iliac Branch Study
An observational study of Abdominal Aortic Aneurysm and Iliac Aneurysm, run by University of Wisconsin, Madison at 1 site in United States.
Trial summary
This project seeks to determine if certain anatomic factors, specifically tortuous and non-conformable iliac arteries, may predict device complications, including seal zone failure, type III endoleak, and occlusion. Read more about this study
- Who is it for?
- Ages 21 years and older
- Conditions the study is for
- Abdominal Aortic Aneurysm, Iliac Aneurysm
- What is being tested?
- Endovascular Repair of abdominal aortic aneurysms
- Type of treatment
- Surgery or procedure
- How many people
- 297 participants
- Where
- 1 siteUnited States
- Study dates
- Nov 2014to Jun 2021
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 21 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: 400 subjects with Endovascular repair with Iliac Branched Devices for treatment of abdominal aortic aneurysm with iliac involvement.
Who may be able to join
- Subjects who have undergone endovascular aortic repair of AAA with iliac involvement via iliac branch device.
Who cannot join
- None
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Global Iliac Branch Study (Iliac Conformability Paper, Gore vs. Cook)
This project seeks to determine if certain anatomic factors, specifically tortuous and non-conformable iliac arteries, may predict device complications, including seal zone failure, type III endoleak, and occlusion. Approximately 400 subjects from 5 academic centers across the United States, Europe, and Asia will be included in this study. Various markers of pre- and post-treatment iliac anatomy will be measured using CT imaging, and clinical events will be reported by academic centers. The relationship of imaging data to patient demographics will then be assessed alongside anatomic and demographic predictors of non-conformability.
Read the detailed description
Background and significance Abdominal aortic aneurysms (AAAs) affect 0.5% to 1.3% of women and 4.0% to 7.6% of men age 65 and older1-4. Infrarenal AAAs frequently extend distally through the aortic bifurcation and into the common, external, and/or internal iliac arteries,5,6 presenting a challenge for aneurysm repair. Current guidelines prioritize repair strategies which preserve blood flow to the internal iliac artery (IIA) with the goal of reducing the complications of buttock claudication and pelvic ischemia.7-9 As endovascular intervention has become standard practice for those with eligible anatomy, 7 branched endovascular devices have been developed to preserve IIA blood flow when repairing AAAs with iliac involvement.
With the ongoing development of devices and techniques, the range of iliac anatomy eligible for endovascular repair has increased. Most notably, multiple iliac branch devices (IBDs) are being used to treat AAAs involving highly tortuous iliac arteries. A variety of IBDs are available globally, and as such, there is an opportunity to determine if certain anatomic factors- specifically tortuous and non-conformable iliac arteries- may predict device complications.
To begin exploring this question, the Global Iliac Branch Study (GIBS)- a partnership between 5 centers across the United States, Europe, and Asia- was developed to evaluate performance of branched endografts based on anatomical assessments, with analysis of CT scans using centralized and standardized analysis protocols at the AortaCore Imaging Lab at the University of Wisconsin-Madison.
Previous work In addition to elevated risk of conversion to open repair,10 iliac tortuosity has previously been associated with increased risk of "conformability" events, including seal zone failure, type III endoleak, occlusion, stenosis, compression, and device migration.11-13
Previously, the applicant and her faculty mentor have explored the interaction between iliac tortuosity and device conformability in patients treated with the W.L.GORE EXCLUDER iliac branch endoprosthesis (IBE).14 Non-conformation was defined as a decrease in the total iliac index of tortuosity beyond 15%. This study found that non-conformation, as well as internal iliac artery diameter of less than 10 mm, were associated with adverse iliac events after iliac branch endoprosthesis (odds ratio, 8.2 [P = .02] and odds ratio, 12.3 [P = .02], respectively).
Similar to the aforementioned studies demonstrating increasing ranges of anatomic eligibility with the development of more complex and accommodating devices, the applicant and her mentor explored device eligibility for endovascular repair (EVAR) of small AAA over two years in a paper published in November 2021 in the Journal of Vascular Surgery which found high levels of anatomic eligibility for EVAR at baseline, and preservation of this eligibility over two years.15 These findings, like those previously mentioned, suggested that advancements in EVAR device design have improved anatomic eligibility for the procedure. Compared to open repair, EVAR is associated with decreased periprocedural morbidity and hospital length of stay,16 and as such is the preferred approach, as well as a major target for innovation in the field of vascular surgery.
Methods and analysis CT images of 400 subjects with IBDs from 5 centers around the globe will be transferred and analyzed at the University of Wisconsin-Madison AortaCore Imaging Lab under an Institutional Review Board (IRB) approved protocol. Post-processing workstations using Aquarius Intuition (version 4.4.12, TeraRecon) will be used to measure morphology data. Each CT will be fit with a manually corrected centerline that is equidistant from the outer walls of the aneurysmal vessels. Measurements will be completed at both the pre-treatment and post-treatment intervals; these include common, external, and internal iliac artery diameters and lengths, common iliac artery index of tortuosity (Common Iliac Index; Centerline length of the common iliac artery (CIA) divided by the shortest straight-line distance between the CIA origin and iliac bifurcation), total iliac artery index of tortuosity (Total Iliac Index; centerline length of the CIA plus centerline length of the external iliac artery, divided by the shortest straight-line distance between the CIA origin and terminal external iliac artery), and presence of the double iliac sign (when any portion of the iliac vessel is tortuous enough to be duplicated in a single cut of an axial computed tomography slice.)17 Figures 1 and 2 demonstrate these measurement techniques for capturing and quantifying tortuosity.
Measurement of these values before and after device deployment allows the determination of differences in iliac artery length pre- and post-treatment, which is used to quantify device "conformability."18 Notably, devices which produce minimal changes to native anatomy are considered more "conformable" and devices that make greater changes to iliac lengths and angle anatomy are considered "non-conformable" (Figure 3.)
In addition to pre-treatment demographics and comorbidities, including age, sex, and geographic origin, associations between iliac tortuosity indices and the aforementioned CT measurements will be determined in relation to clinical events collected by each center including conversion to open repair, re-intervention, endoleak, occlusion, compression, patient-reported symptoms and adverse events, and death.
Continuous variables will be compared using the unpaired Student t test if normally distributed and the Mann-Whitney U test or Wilcoxon matched pairs test if they are not normally distributed. Categorical variables will be compared using the Fisher exact test or Pearson's x2 test.
Expected outcomes As previously described, in preliminary data14 we have identified that a postoperative change in iliac tortuosity ("non-conformability") predicts adverse events in a sample size of 98 patients. We hypothesize that a larger sample size of 400 patients will confirm this relationship between non-conformability and adverse events, and enable identification of pre-operative predictors of non-conformability. Furthermore, we anticipate that the inclusion of a more diverse selection of endovascular devices will more broadly capture the relationship between device conformability and iliac tortuosity beyond what can be determined based on commercially available devices in the United States.
- Conditions
- Abdominal Aortic Aneurysm, Iliac Aneurysm
- Being tested
- Endovascular Repair of abdominal aortic aneurysms
- Keywords
- Abdominal aortic aneurysm, Aorta-Iliac aneurysm, Endovascular aneurysm repair, Iliac Branch Devices
- Medical subject headings
- Aortic Aneurysm, Abdominal, Iliac Aneurysm
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Endovascular Repair of abdominal aortic aneurysmsProcedure or surgery
Also called Endovascular repair of abdominal aorto-iliac aneurysm
Femoral artery access
What is being measured
The primary outcome is the main question the study is designed to answer.
Device conformability in relation to endovascular repair of abdominal aortoiliac aneurysms.
Adverse events: any radiographic or clinical ipsilateral complication, i.e. dissection, kink, compression, occlusion, endoleaks.
Measured: Pre-treatment
Device conformability in relation to endovascular repair of abdominal aortoiliac aneurysms.
Adverse events: any radiographic or clinical ipsilateral complication, i.e. dissection, kink, compression, occlusion, endoleaks.
Measured: 1 day at First post-operative imaging appointment
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted7 Nov 2022
- Study startNov 2014
- Primary completionDec 2020
- Study completionJun 2021
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (16)Papers the sponsor has linked to this study.
- Other trials for Abdominal Aortic AneurysmStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case only
- Time perspective
- Retrospective
- Enrolment
- 297 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Wisconsin, Madison
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Jon Matsumura, MD, Principal investigator, University of Wisconsin, Madison
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05607277
- Sponsor's protocol ID
- 2020-0677
- Other IDs
- A539750, SMPH/SURGERY/VASCULAR SURGERY, Protocol Version 7/29/2020
- Acronym
- GIBS
- Status last verified
- Oct 2022
- First submitted
- 26 Oct 2022
- Last updated
- 19 Apr 2024
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Publications
Chichester Aneurysm Screening Group; Viborg Aneurysm Screening Study; Western Australian Abdominal Aortic Aneurysm Program; Multicentre Aneurysm Screening Study. A comparative study of the prevalence of abdominal aortic aneurysms in the United Kingdom, Denmark, and Australia. J Med Screen. 2001;8(1):46-50. doi: 10.1136/jms.8.1.46.
PubMed 11373850Derubertis BG, Trocciola SM, Ryer EJ, Pieracci FM, McKinsey JF, Faries PL, Kent KC. Abdominal aortic aneurysm in women: prevalence, risk factors, and implications for screening. J Vasc Surg. 2007 Oct;46(4):630-635. doi: 10.1016/j.jvs.2007.06.024.
PubMed 17903646US Preventive Services Task Force; Owens DK, Davidson KW, Krist AH, Barry MJ, Cabana M, Caughey AB, Doubeni CA, Epling JW Jr, Kubik M, Landefeld CS, Mangione CM, Pbert L, Silverstein M, Simon MA, Tseng CW, Wong JB. Screening for Abdominal Aortic Aneurysm: US Preventive Services Task Force Recommendation Statement. JAMA. 2019 Dec 10;322(22):2211-2218. doi: 10.1001/jama.2019.18928.
PubMed 31821437Svensjo S, Bjorck M, Wanhainen A. Current prevalence of abdominal aortic aneurysm in 70-year-old women. Br J Surg. 2013 Feb;100(3):367-72. doi: 10.1002/bjs.8984. Epub 2012 Nov 28.
PubMed 23192439Ghosh J, Murray D, Paravastu S, Farquharson F, Walker MG, Serracino-Inglott F. Contemporary management of aorto-iliac aneurysms in the endovascular era. Eur J Vasc Endovasc Surg. 2009 Feb;37(2):182-8. doi: 10.1016/j.ejvs.2008.11.001. Epub 2008 Nov 29.
PubMed 19046903Maurel B, Bartoli MA, Jean-Baptiste E, Reix T, Cardon A, Goueffic Y, Martinez R, Cochennec F, Albertini JN, Chauffour X, Steinmetz E, Haulon S; Association Universitaire de Recherche en Chirurgie Vasculaire, France. Perioperative evaluation of iliac ZBIS branch devices: a French multicenter study. Ann Vasc Surg. 2013 Feb;27(2):131-8. doi: 10.1016/j.avsg.2011.02.052.
PubMed 23380549Chaikof EL, Dalman RL, Eskandari MK, Jackson BM, Lee WA, Mansour MA, Mastracci TM, Mell M, Murad MH, Nguyen LL, Oderich GS, Patel MS, Schermerhorn ML, Starnes BW. The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm. J Vasc Surg. 2018 Jan;67(1):2-77.e2. doi: 10.1016/j.jvs.2017.10.044.
PubMed 29268916Faries PL, Morrissey N, Burks JA, Gravereaux E, Kerstein MD, Teodorescu VJ, Hollier LH, Marin ML. Internal iliac artery revascularization as an adjunct to endovascular repair of aortoiliac aneurysms. J Vasc Surg. 2001 Nov;34(5):892-9. doi: 10.1067/mva.2001.118085.
PubMed 11700492Kouvelos GN, Katsargyris A, Antoniou GA, Oikonomou K, Verhoeven EL. Outcome after Interruption or Preservation of Internal Iliac Artery Flow During Endovascular Repair of Abdominal Aorto-iliac Aneurysms. Eur J Vasc Endovasc Surg. 2016 Nov;52(5):621-634. doi: 10.1016/j.ejvs.2016.07.081. Epub 2016 Sep 2.
PubMed 27600731Cuypers PW, Laheij RJ, Buth J. Which factors increase the risk of conversion to open surgery following endovascular abdominal aortic aneurysm repair? The EUROSTAR collaborators. Eur J Vasc Endovasc Surg. 2000 Aug;20(2):183-9. doi: 10.1053/ejvs.2000.1167.
PubMed 10944101Iwakoshi S, Nakai T, Ichihashi S, Inoue T, Sakaguchi S, Hirose T, Tabayashi N, Watkins AC, Kichikawa K. Conformability and Efficacy of the Zenith Spiral Z Leg Compared with the Zenith Flex Leg in Endovascular Abdominal Aortic Aneurysm Repair. Ann Vasc Surg. 2019 Aug;59:127-133. doi: 10.1016/j.avsg.2019.02.013. Epub 2019 May 7.
PubMed 31071429Wolf YG, Tillich M, Lee WA, Rubin GD, Fogarty TJ, Zarins CK. Impact of aortoiliac tortuosity on endovascular repair of abdominal aortic aneurysms: evaluation of 3D computer-based assessment. J Vasc Surg. 2001 Oct;34(4):594-9. doi: 10.1067/mva.2001.118586.
PubMed 11668310Parra JR, Ayerdi J, McLafferty R, Gruneiro L, Ramsey D, Solis M, Hodgson K. Conformational changes associated with proximal seal zone failure in abdominal aortic endografts. J Vasc Surg. 2003 Jan;37(1):106-11. doi: 10.1067/mva.2002.53.
PubMed 12514585DeRoo E, Harris D, Olson S, Panthofer A, Meadows W, Pauli T, Peterson B, Schneider D, Matsumura J. Conformability of the GORE EXCLUDER iliac branch endoprosthesis is associated with freedom from adverse iliac events. J Vasc Surg. 2021 Nov;74(5):1558-1564.e1. doi: 10.1016/j.jvs.2021.05.026. Epub 2021 Jun 1.
PubMed 34082005Panthofer AM, Olson SL, Rademacher BL, Grudzinski JK, Chaikof EL, Matsumura JS; N-TA(3)CT Investigators. Anatomic eligibility for endovascular aneurysm repair preserved over 2 years of surveillance. J Vasc Surg. 2021 Nov;74(5):1527-1536.e1. doi: 10.1016/j.jvs.2021.04.044. Epub 2021 May 4.
PubMed 33957227
Study at a glance
From the registry record, last updated by the sponsor on 19 Apr 2024. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Global Iliac Branch Study (Iliac Conformability Paper, Gore vs. Cook)
- ClinicalTrials.gov ID
- NCT05607277
- Acronym / sponsor ID
- GIBS / 2020-0677
- Conditions
- Abdominal Aortic Aneurysm, Iliac Aneurysm
- Keywords
- Abdominal aortic aneurysm, Aorta-Iliac aneurysm, Endovascular aneurysm repair, Iliac Branch Devices
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 297 participants (actual)
- Lead sponsor
- University of Wisconsin, MadisonUniversity, hospital or other
- Study start
- Nov 2014 (actual)
- Primary completion
- Dec 2020 (actual)
- Study completion
- Jun 2021 (actual)
- First posted
- 7 Nov 2022 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This project seeks to determine if certain anatomic factors, specifically tortuous and non-conformable iliac arteries, may predict device complications, including seal zone failure, type III endoleak, and occlusion. Approximately 400 subjects from 5 academic centers across the United States, Europe, and Asia will be included in this study. Various markers of pre- and post-treatment iliac anatomy will be measured using CT imaging, and clinical events will be reported by academic centers. The relationship of imaging data to patient demographics will then be assessed alongside anatomic and demographic predictors of non-conformability.
Detailed description
Background and significance Abdominal aortic aneurysms (AAAs) affect 0.5% to 1.3% of women and 4.0% to 7.6% of men age 65 and older1-4. Infrarenal AAAs frequently extend distally through the aortic bifurcation and into the common, external, and/or internal iliac arteries,5,6 presenting a challenge for aneurysm repair. Current guidelines prioritize repair strategies which preserve blood flow to the internal iliac artery (IIA) with the goal of reducing the complications of buttock claudication and pelvic ischemia.7-9 As endovascular intervention has become standard practice for those with eligible anatomy, 7 branched endovascular devices have been developed to preserve IIA blood flow when repairing AAAs with iliac involvement.
With the ongoing development of devices and techniques, the range of iliac anatomy eligible for endovascular repair has increased. Most notably, multiple iliac branch devices (IBDs) are being used to treat AAAs involving highly tortuous iliac arteries. A variety of IBDs are available globally, and as such, there is an opportunity to determine if certain anatomic factors- specifically tortuous and non-conformable iliac arteries- may predict device complications.
To begin exploring this question, the Global Iliac Branch Study (GIBS)- a partnership between 5 centers across the United States, Europe, and Asia- was developed to evaluate performance of branched endografts based on anatomical assessments, with analysis of CT scans using centralized and standardized analysis protocols at the AortaCore Imaging Lab at the University of Wisconsin-Madison.
Previous work In addition to elevated risk of conversion to open repair,10 iliac tortuosity has previously been associated with increased risk of "conformability" events, including seal zone failure, type III endoleak, occlusion, stenosis, compression, and device migration.11-13
Previously, the applicant and her faculty mentor have explored the interaction between iliac tortuosity and device conformability in patients treated with the W.L.GORE EXCLUDER iliac branch endoprosthesis (IBE).14 Non-conformation was defined as a decrease in the total iliac index of tortuosity beyond 15%. This study found that non-conformation, as well as internal iliac artery diameter of less than 10 mm, were associated with adverse iliac events after iliac branch endoprosthesis (odds ratio, 8.2 [P = .02] and odds ratio, 12.3 [P = .02], respectively).
Similar to the aforementioned studies demonstrating increasing ranges of anatomic eligibility with the development of more complex and accommodating devices, the applicant and her mentor explored device eligibility for endovascular repair (EVAR) of small AAA over two years in a paper published in November 2021 in the Journal of Vascular Surgery which found high levels of anatomic eligibility for EVAR at baseline, and preservation of this eligibility over two years.15 These findings, like those previously mentioned, suggested that advancements in EVAR device design have improved anatomic eligibility for the procedure. Compared to open repair, EVAR is associated with decreased periprocedural morbidity and hospital length of stay,16 and as such is the preferred approach, as well as a major target for innovation in the field of vascular surgery.
Methods and analysis CT images of 400 subjects with IBDs from 5 centers around the globe will be transferred and analyzed at the University of Wisconsin-Madison AortaCore Imaging Lab under an Institutional Review Board (IRB) approved protocol. Post-processing workstations using Aquarius Intuition (version 4.4.12, TeraRecon) will be used to measure morphology data. Each CT will be fit with a manually corrected centerline that is equidistant from the outer walls of the aneurysmal vessels. Measurements will be completed at both the pre-treatment and post-treatment intervals; these include common, external, and internal iliac artery diameters and lengths, common iliac artery index of tortuosity (Common Iliac Index; Centerline length of the common iliac artery (CIA) divided by the shortest straight-line distance between the CIA origin and iliac bifurcation), total iliac artery index of tortuosity (Total Iliac Index; centerline length of the CIA plus centerline length of the external iliac artery, divided by the shortest straight-line distance between the CIA origin and terminal external iliac artery), and presence of the double iliac sign (when any portion of the iliac vessel is tortuous enough to be duplicated in a single cut of an axial computed tomography slice.)17 Figures 1 and 2 demonstrate these measurement techniques for capturing and quantifying tortuosity.
Measurement of these values before and after device deployment allows the determination of differences in iliac artery length pre- and post-treatment, which is used to quantify device "conformability."18 Notably, devices which produce minimal changes to native anatomy are considered more "conformable" and devices that make greater changes to iliac lengths and angle anatomy are considered "non-conformable" (Figure 3.)
In addition to pre-treatment demographics and comorbidities, including age, sex, and geographic origin, associations between iliac tortuosity indices and the aforementioned CT measurements will be determined in relation to clinical events collected by each center including conversion to open repair, re-intervention, endoleak, occlusion, compression, patient-reported symptoms and adverse events, and death.
Continuous variables will be compared using the unpaired Student t test if normally distributed and the Mann-Whitney U test or Wilcoxon matched pairs test if they are not normally distributed. Categorical variables will be compared using the Fisher exact test or Pearson's x2 test.
Expected outcomes As previously described, in preliminary data14 we have identified that a postoperative change in iliac tortuosity ("non-conformability") predicts adverse events in a sample size of 98 patients. We hypothesize that a larger sample size of 400 patients will confirm this relationship between non-conformability and adverse events, and enable identification of pre-operative predictors of non-conformability. Furthermore, we anticipate that the inclusion of a more diverse selection of endovascular devices will more broadly capture the relationship between device conformability and iliac tortuosity beyond what can be determined based on commercially available devices in the United States.
Study design
- Observational model
- Case only
- Time perspective
- Retrospective
Who may qualify
- Ages
- 21 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- 400 subjects with Endovascular repair with Iliac Branched Devices for treatment of abdominal aortic aneurysm with iliac involvement.
Key inclusion criteria (1 listed)
- Subjects who have undergone endovascular aortic repair of AAA with iliac involvement via iliac branch device.
Key exclusion criteria (1 listed)
- None
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Endovascular Repair of abdominal aortic aneurysmsAlso: Endovascular repair of abdominal aorto-iliac aneurysmFemoral artery access | Procedure or surgery | – |
Primary outcome
Device conformability in relation to endovascular repair of abdominal aortoiliac aneurysms.
Time frame: Pre-treatment
Adverse events: any radiographic or clinical ipsilateral complication, i.e. dissection, kink, compression, occlusion, endoleaks.
Device conformability in relation to endovascular repair of abdominal aortoiliac aneurysms.
Time frame: 1 day at First post-operative imaging appointment
Adverse events: any radiographic or clinical ipsilateral complication, i.e. dissection, kink, compression, occlusion, endoleaks.
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 19 Apr 2024.
- Background: PubMed 11373850Chichester Aneurysm Screening Group; Viborg Aneurysm Screening Study; Western Australian Abdominal Aortic Aneurysm Program; Multicentre Aneurysm Screening Study. A comparative study of the prevalence of abdominal aortic aneurysms in the United Kingdom, Denmark, and Australia. J Med Screen. 2001;8(1):46-50. doi: 10.1136/jms.8.1.46.
- Background: PubMed 17903646Derubertis BG, Trocciola SM, Ryer EJ, Pieracci FM, McKinsey JF, Faries PL, Kent KC. Abdominal aortic aneurysm in women: prevalence, risk factors, and implications for screening. J Vasc Surg. 2007 Oct;46(4):630-635. doi: 10.1016/j.jvs.2007.06.024.
- Background: PubMed 31821437US Preventive Services Task Force; Owens DK, Davidson KW, Krist AH, Barry MJ, Cabana M, Caughey AB, Doubeni CA, Epling JW Jr, Kubik M, Landefeld CS, Mangione CM, Pbert L, Silverstein M, Simon MA, Tseng CW, Wong JB. Screening for Abdominal Aortic Aneurysm: US Preventive Services Task Force Recommendation Statement. JAMA. 2019 Dec 10;322(22):2211-2218. doi: 10.1001/jama.2019.18928.
- Background: PubMed 23192439Svensjo S, Bjorck M, Wanhainen A. Current prevalence of abdominal aortic aneurysm in 70-year-old women. Br J Surg. 2013 Feb;100(3):367-72. doi: 10.1002/bjs.8984. Epub 2012 Nov 28.
- Background: PubMed 19046903Ghosh J, Murray D, Paravastu S, Farquharson F, Walker MG, Serracino-Inglott F. Contemporary management of aorto-iliac aneurysms in the endovascular era. Eur J Vasc Endovasc Surg. 2009 Feb;37(2):182-8. doi: 10.1016/j.ejvs.2008.11.001. Epub 2008 Nov 29.
- Background: PubMed 23380549Maurel B, Bartoli MA, Jean-Baptiste E, Reix T, Cardon A, Goueffic Y, Martinez R, Cochennec F, Albertini JN, Chauffour X, Steinmetz E, Haulon S; Association Universitaire de Recherche en Chirurgie Vasculaire, France. Perioperative evaluation of iliac ZBIS branch devices: a French multicenter study. Ann Vasc Surg. 2013 Feb;27(2):131-8. doi: 10.1016/j.avsg.2011.02.052.
- Background: PubMed 29268916Chaikof EL, Dalman RL, Eskandari MK, Jackson BM, Lee WA, Mansour MA, Mastracci TM, Mell M, Murad MH, Nguyen LL, Oderich GS, Patel MS, Schermerhorn ML, Starnes BW. The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm. J Vasc Surg. 2018 Jan;67(1):2-77.e2. doi: 10.1016/j.jvs.2017.10.044.
- Background: PubMed 11700492Faries PL, Morrissey N, Burks JA, Gravereaux E, Kerstein MD, Teodorescu VJ, Hollier LH, Marin ML. Internal iliac artery revascularization as an adjunct to endovascular repair of aortoiliac aneurysms. J Vasc Surg. 2001 Nov;34(5):892-9. doi: 10.1067/mva.2001.118085.
- Background: PubMed 27600731Kouvelos GN, Katsargyris A, Antoniou GA, Oikonomou K, Verhoeven EL. Outcome after Interruption or Preservation of Internal Iliac Artery Flow During Endovascular Repair of Abdominal Aorto-iliac Aneurysms. Eur J Vasc Endovasc Surg. 2016 Nov;52(5):621-634. doi: 10.1016/j.ejvs.2016.07.081. Epub 2016 Sep 2.
- Background: PubMed 10944101Cuypers PW, Laheij RJ, Buth J. Which factors increase the risk of conversion to open surgery following endovascular abdominal aortic aneurysm repair? The EUROSTAR collaborators. Eur J Vasc Endovasc Surg. 2000 Aug;20(2):183-9. doi: 10.1053/ejvs.2000.1167.
- Background: PubMed 31071429Iwakoshi S, Nakai T, Ichihashi S, Inoue T, Sakaguchi S, Hirose T, Tabayashi N, Watkins AC, Kichikawa K. Conformability and Efficacy of the Zenith Spiral Z Leg Compared with the Zenith Flex Leg in Endovascular Abdominal Aortic Aneurysm Repair. Ann Vasc Surg. 2019 Aug;59:127-133. doi: 10.1016/j.avsg.2019.02.013. Epub 2019 May 7.
- Background: PubMed 11668310Wolf YG, Tillich M, Lee WA, Rubin GD, Fogarty TJ, Zarins CK. Impact of aortoiliac tortuosity on endovascular repair of abdominal aortic aneurysms: evaluation of 3D computer-based assessment. J Vasc Surg. 2001 Oct;34(4):594-9. doi: 10.1067/mva.2001.118586.
- Individual participant dataSharing planned: No
Related trials for Abdominal Aortic Aneurysm
RecruitingPhase 4
Effect of Remimazolam Versus Propofol Total Intravenous Anesthesia on Intraoperative Hemodynamic Stability in Patients Undergoing Thoracic or Abdominal Endovascular Aortic Repair
Aortic Aneurysm, Thoracoabdominal, Aortic Aneurysm, Abdominal
Not yet recruitingObservational study
Aortic Size and Height Indices in Abdominal Aortic Aneurysms
Abdominal Aortic Aneurysm, Abdominal Aortic Aneurysm, Ruptured
Not yet recruitingObservational study
Real-World Data Collection of GORE Devices Used In the Endovascular Treatment of Aortic Aneurysms Which Incorporate Visceral Arteries.
Complex Aortic Aneurysms, Thoracoabdominal Aneurysm
Enrolling by invitation
Endovascular Treatment of Thoracic Aortic Disease
Thoracic Aortic Aneurysms, Dissecting, Aneurysm
Active, not recruiting
ANEUFIX for Endoleak Type II Repair
Abdominal Aortic Aneurysm, Endoleak
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Jon Matsumura, MD principal investigator
University of Wisconsin, Madison
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Abdominal Aortic Aneurysm and Iliac Aneurysm, run by University of Wisconsin, Madison at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 19 Apr 2024. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Device conformability in relation to endovascular repair of abdominal aortoiliac aneurysms. (time frame: Pre-treatment). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT05607277, which also lists 16 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Apr 2024.