Pre-TermNEO2MATICNCT05629910
NeO2Matic-Pilot Trial
A study testing O2Matic in people with Pre-Term and Respiratory Distress Syndrome, Newborn, run by Copenhagen University Hospital, Rigshospitalet at 1 site in Denmark.
Trial summary
The main goal of this trial is to test if: automated adjustment of supplemental oxygen to preterm infants in noninvasive respiratory support based on feedback from a measurement of blood-oxygen saturation results in more stable blood-oxygenation compared to routine nurse controlled adjustment of oxygen Read more about this study
- Who is it for?
- Ages Up to 6 months
- Conditions the study is for
- Pre-Term, Respiratory Distress Syndrome, Newborn, Retinopathy of Prematurity
- What is being tested?
- O2Matic
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 30 participants
- Where
- 1 siteDenmark
- Study dates
- 1 Jan 2024to 1 Jul 2025
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages Up to 6 months
- All sexes
- No healthy volunteers
- Child
Who may be able to join
- Newborn infants receiving nHFT via Optiflow 4-8 l/min and FiO2>0.25, requiring adjustments of FiO2 beyond the extra need during care procedures
- Likely to be maintained on nHFT during study period of 48 hrs
Who cannot join
- major congenital abnormalities
- hemodynamic instability including large PDA with right to left shunting
- clinician's concern regarding infant stability.
- Unstable infants with frequent apneas, predominantly having need for oxygen during apneic events
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Randomised Cross-over Study of Closed Loop Oxygen Control in Newborn Infants Receiving Nasal Highflow Therapy Via Airvo-2 Combined With O2Matic
The main goal of this trial is to test if:
automated adjustment of supplemental oxygen to preterm infants in noninvasive respiratory support based on feedback from a measurement of blood-oxygen saturation
results in more stable blood-oxygenation compared to routine nurse controlled adjustment of oxygen
Read the detailed description
Due to immature lungs and immature regulation of breathing, preterm infants require long periods of respiratory support including supplemental oxygen. Noninvasive monitoring of oxygenation using pulse oximetry (SpO2, blood oxygen saturation) has become standard of care despite not always accurately reflecting paO2 (partial pressure of oxygen). Several clinical trials have aimed to determine the optimal range for SpO2. Although subject to an ongoing debate currently most neonatal units aim to keep SpO2 within a target-range (TR) of 90-95% based on consensus guidelines. Recent reviews and meta-analyses have shown that SpO2 outside this range is associated with adverse outcome. Hyperoxia is associated with BPD (bronchopulmonary dysplasia) and ROP (retinopathy of prematurity), whereas hypoxia is associated with an increased risk of necrotizing enterocolitis, death and brain damage.
Keeping SpO2 within TR is difficult for the clinical staff and may require frequent manual adjustments of FiO2 (fraction of inspired oxygen) thus representing a huge workload. Recent studies have shown that babies often spend less than 50% of time with SpO2 within target range.
Due to limitations of manual control of FiO2, several commercially available algorithms have been developed facilitating automatic oxygen control (AOC) or closed loop automated oxygen control (CLAC) using feedback from the pulse oximetry as input. Observational trials, randomized clinical trials as well as meta-analyses of short-term outcomes have with a reasonable consistency shown automatic oxygen control to be associated with a significant increase in SpO2 spent in TR from approximately 50% to above 70-80% of time, a reduction in number and duration of episodes with hypoxemia and hyperoxemia , and a substantial reduction in the need for manual adjustments of FiO2 from more than 20 times to one during automated oxygen control.. It still remains to be determined if automatic oxygen control improves relevant long term outcomes, but a large international multi-center randomized clinical trial (FiO2-C Trial) is expected to report on long-term outcomes within 12-24 months.
The current commercially available systems for automatic oxygen control are integrated into brand- specific ventilator-systems and may only work with devices and consumables from that particular company. O2matic® is a danish automatic oxygen control system registered for use in adult patients and has been shown to be significantly better than manual control to maintain SpO2 within target O2matic® has never been tested in a neonatal population but can potentially be used as an add-on to several respiratory support systems used in neonatal care, possibly making automatic oxygen control more universally available at a lower cost. This protocol describes a proposed pilot-trial of automatic oxygen control using O2matic® in spontaneously breathing newborn infants needing respiratory support.
Research question and aim The primary objective is to evaluate if automated adjustment of FiO2 by O2Matic during neonatal nasal highflow therapy or CPAP improves the duration of SpO2 being within target range when compared to nurse-controlled (manual) adjustment of FiO2.
This will be done in a randomized controll cross over trial.
O2Matic - investigational device The O2Matic oxygen controller is a closed-loop system that, based on continuous monitoring of pulse and SpO2 by a wired pulse oximeter, adjusts oxygen flow to the patient. The algorithm in O2matic samples the last 15 seconds of input from the pulse oximeter and calculates increments or decrements in oxygen flow every second based on the last 15 seconds' average. Increments and decrements are proportionally increased relative to the difference between actual SpO2 and target SpO2. Maximal oxygen flow can be specified to fit the actual condition treated and the device used for delivering oxygen to the patient. O2matic allows for flow up to 15 L/minute in automatic mode, but will in this project be limited to 0-8 L/minute which are the flowrates used for nHFT (see further down). During the study alarms from SpO2 and heart-rate-out-of-range will be silenced and blinded (see further down) as study participants will be monitored using the usual central monitoring system used in the NICU The only alarm allowed will be for loss of signal from the oximetry sensor which can be individualized from 0 to 5 minutes, to avoid repeated alarms due to signal loss of shorter duration. The O2Matic is CE-marked and designed for adult care but not registered for use in patients less than 18 years of age. Consequently, this study also aims to test the use of O2Matic in a new patient group.
The O2Matic is only compatible with the Nonin Purelight pulse oximetry sensors - including Nonin Neonatal Oximetry sensors.
During the intervention the O2Matic will be operating in automatic mode adjusting the oxygen flow in response to changes in SpO2.
During the control period O2Matic will be deactivated.
Nasal High Flow Therapy via AIRVO-2 Nasal high flow therapy (nHFT) is a standard treatment modality in neonatal respiratory care which can be provided using the OptiFlowTM interface from Fischer \& Paykell and a gas source providing a mixture of humidified air and oxygen.
The AIRVO-2TM is a humidifier with an integrated flow generator able to deliver warmed and humidified respiratory gases to spontaneously breathing patients through a variety of specific patient interfaces in varying sizes (OptiFlowTM). In clinical practice AIRVO-2 is used with OptiFlow prongs from size "preterm" and up, although the recommended size is from size "infant".
The AIRVO-2 is designed to be able to deliver flow at a constant set flow rate which will be kept constant regardless of manual changes in the fraction of inspired oxygen (FiO2) - the resulting FiO2 will be shown on the display. When used in this study the AIRVO-2 will be used in junior-mode which is necessary when used with a neonatal interface. In junior-mode humidification-temperature is limited to 34 degrees and airflow to a maximum of 25 L/min but in the current study only up to 8 L/min will be used.
Closed loop adjustment of oxygen via O2Matic and AIRVO-2 Oxygen supply to AIRVO-2 can be delivered by connecting the oxygen output from O2Matic to the oxygen inlet on AIRVO-2. In this way nHFT from AIRVO-2 can be delivered with automatically adjusted oxygen supply via the closed loop system from O2Matic at a constant set-flowrate controlled by AIRVO- 2, with the resulting FiO2 measured and displayed by AIRVO-2. O2Matic will adjust FiO2 based on the reading from the Nonin Purelight pulse oximeter connected to O2Matic. It is important to note, that the reading from this pulse oximeter will be blinded to the clinical staff, and all manual adjustments to FiO2 will be done based on readings from the pulse oximeter connected to the central monitoring system in the NICU (Avant 9600 Nonin Pulsoximeter connected via Philips Intellivue).
Study outline and trial design
The study is a pilot trial and designed as an order-randomized, cross-over trial. Infants will be randomized to treatment-order by block randomization to ensure even distribution between the sequence of treatment. All infants will at study start receive nHFT via OptiFlow interface, and then be allocated to:
- Automated adjustment of FiO2 by O2Matic followed by manual FiO2 adjustment or
- Manual adjustment of FiO2 followed by Automated adjustment of FiO2 by O2Matic
Each patient will serve as their own control, and each treatment-period will last 24 hours, and each patient will be exposed to 1 period of each treatment assignment.
- Conditions
- Pre-Term, Respiratory Distress Syndrome, Newborn, Retinopathy of Prematurity, Bronchopulmonary Dysplasia
- Being tested
- O2Matic
- Keywords
- closed loop oxygen control
- Medical subject headings
- Premature Birth, Respiratory Distress Syndrome, Newborn, Retinopathy of Prematurity, Bronchopulmonary Dysplasia
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
O2MaticDevice
During the interventional period the O2Matic will operate in automatic mode using the Neonatal Study Profile. O2Matic will continuously adjust the O2 flow to adjust SpO2 within range based on readings from the pulse oximeter connected to O2Matic, while AIRVO-2 will adjust the flow of ambient air to keep the total gas flow constant.
| Study group | Role | What they receive |
|---|---|---|
| Interventional period: Automated adjustment of FiO2 by O2Matic | Experimental | During the interventional period the O2Matic will operate in automatic mode using the Neonatal Study Profile. O2Matic will continuously adjust the O2 flow to adjust SpO2 within range based on readings from the pulse oximeter connected to O2Matic, while AIRVO-2 will adjust the flow of ambient air to keep the total gas flow constant. Receives: Device: O2Matic |
| Control period - manual adjustment of FiO2 | No intervention | During the control period, the bedside nurse will manually change FiO2 as per routine based on the reading from the Avant 9600 Nonin pulse oximeter connected to the central monitoring system), by changing oxygenflow from O2Matic as required to induce appropriate changes in SpO2: |
What is being measured
The primary outcome is the main question the study is designed to answer.
time in target SpO2 range 90%-95% (90%-100% if FiO2 =21%)
total time spent in target SpO2 range:
- measured by the Nonin pulse oximeter connected to O2Matic and/or
- measured by the Avant 9600 Nonin Pulse oximeter providing data from this pulse oximeter
Measured: 48 hours
Secondary outcomes (9)
number of episodes of SpO2 below 80% lasting at least 60 seconds
analyzed via excel/mat lab
Measured: 48 hours
relative SpO2 distribution in the ranges <80%, 81-85%, 86-89%, 90-95%, >95%
analyzed via excel/mat lab
Measured: 48 hours
burden of hypoxia, i.e. the 'area under the curve' using spO2 = 80% as the threshold
analyzed via excel/mat lab
Measured: 48 hours
duration of episodes with SpO2 above 95% or below 90%
analyzed via excel/mat lab
Measured: 48 hours
frequency of episodes with SpO2 above 95% or below 90%
analyzed via excel/mat lab
Measured: 48 hours
frequency of FiO2 adjustments recorded by O2Matic both during automated and manual mode
analyzed via excel/mat lab
Measured: 48 hours
number of "manual override" of FiO2 control during automated mode
analyzed via excel/mat lab
Measured: 48 hours
overall mean FiO2
analyzed via excel/mat lab
Measured: 48 hours
overall mean flow
analyzed via excel/mat lab
Measured: 48 hours
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted29 Nov 2022
- Study start1 Jan 2024 (estimated)
- Primary completion1 Jan 2025 (estimated)
- Study completion1 Jul 2025 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Pre-TermStudies of the same condition, open and under way.
- More trials run by Copenhagen University Hospital, RigshospitaletThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Model description
- The study is a pilot trial and designed as a order-randomized, cross-over trial. Infants will be randomised to treatment-order by block randomisation to ensure even distribution between the sequence of treatment. All infants will at study start receive nHFT via OptiFlow interface, and then be allocated to: ▪ Automated adjustment of FiO2 by O2Matic followed by manual FiO2 adjustment or ▪ Manual adjustment of FiO2 followed by Automated adjustment of FiO2 by O2Matic Each patient will serve as their own control, and each treatment-period will last 24 hours, and each patient will be exposed to 1 period of each treatment assignment.
- Masking
- None (open label)
- Enrolment
- 30 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Copenhagen University Hospital, Rigshospitalet
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Christian Heiring, Copenhagen University Hospital, Rigshospitalet
- Investigators
- Christian Heiring, Principal investigator, Copenhagen University Hospital, Rigshospitalet
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05629910
- Sponsor's protocol ID
- 2208839
- Other IDs
- 2022051232
- Acronym
- NEO2MATIC
- Status last verified
- Nov 2023
- First submitted
- 7 Nov 2022
- Last updated
- 18 Nov 2023
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 18 Nov 2023. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Randomised Cross-over Study of Closed Loop Oxygen Control in Newborn Infants Receiving Nasal Highflow Therapy Via Airvo-2 Combined With O2Matic
- ClinicalTrials.gov ID
- NCT05629910
- Acronym / sponsor ID
- NEO2MATIC / 2208839
- Conditions
- Pre-Term, Respiratory Distress Syndrome, Newborn, Retinopathy of Prematurity, Bronchopulmonary Dysplasia
- Keywords
- closed loop oxygen control
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 30 participants (estimated)
- Lead sponsor
- Copenhagen University Hospital, RigshospitaletUniversity, hospital or other
- Study start
- 1 Jan 2024 (estimated)
- Primary completion
- 1 Jan 2025 (estimated)
- Study completion
- 1 Jul 2025 (estimated)
- First posted
- 29 Nov 2022 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The main goal of this trial is to test if:
automated adjustment of supplemental oxygen to preterm infants in noninvasive respiratory support based on feedback from a measurement of blood-oxygen saturation
results in more stable blood-oxygenation compared to routine nurse controlled adjustment of oxygen
Detailed description
Due to immature lungs and immature regulation of breathing, preterm infants require long periods of respiratory support including supplemental oxygen. Noninvasive monitoring of oxygenation using pulse oximetry (SpO2, blood oxygen saturation) has become standard of care despite not always accurately reflecting paO2 (partial pressure of oxygen). Several clinical trials have aimed to determine the optimal range for SpO2. Although subject to an ongoing debate currently most neonatal units aim to keep SpO2 within a target-range (TR) of 90-95% based on consensus guidelines. Recent reviews and meta-analyses have shown that SpO2 outside this range is associated with adverse outcome. Hyperoxia is associated with BPD (bronchopulmonary dysplasia) and ROP (retinopathy of prematurity), whereas hypoxia is associated with an increased risk of necrotizing enterocolitis, death and brain damage.
Keeping SpO2 within TR is difficult for the clinical staff and may require frequent manual adjustments of FiO2 (fraction of inspired oxygen) thus representing a huge workload. Recent studies have shown that babies often spend less than 50% of time with SpO2 within target range.
Due to limitations of manual control of FiO2, several commercially available algorithms have been developed facilitating automatic oxygen control (AOC) or closed loop automated oxygen control (CLAC) using feedback from the pulse oximetry as input. Observational trials, randomized clinical trials as well as meta-analyses of short-term outcomes have with a reasonable consistency shown automatic oxygen control to be associated with a significant increase in SpO2 spent in TR from approximately 50% to above 70-80% of time, a reduction in number and duration of episodes with hypoxemia and hyperoxemia , and a substantial reduction in the need for manual adjustments of FiO2 from more than 20 times to one during automated oxygen control.. It still remains to be determined if automatic oxygen control improves relevant long term outcomes, but a large international multi-center randomized clinical trial (FiO2-C Trial) is expected to report on long-term outcomes within 12-24 months.
The current commercially available systems for automatic oxygen control are integrated into brand- specific ventilator-systems and may only work with devices and consumables from that particular company. O2matic® is a danish automatic oxygen control system registered for use in adult patients and has been shown to be significantly better than manual control to maintain SpO2 within target O2matic® has never been tested in a neonatal population but can potentially be used as an add-on to several respiratory support systems used in neonatal care, possibly making automatic oxygen control more universally available at a lower cost. This protocol describes a proposed pilot-trial of automatic oxygen control using O2matic® in spontaneously breathing newborn infants needing respiratory support.
Research question and aim The primary objective is to evaluate if automated adjustment of FiO2 by O2Matic during neonatal nasal highflow therapy or CPAP improves the duration of SpO2 being within target range when compared to nurse-controlled (manual) adjustment of FiO2.
This will be done in a randomized controll cross over trial.
O2Matic - investigational device The O2Matic oxygen controller is a closed-loop system that, based on continuous monitoring of pulse and SpO2 by a wired pulse oximeter, adjusts oxygen flow to the patient. The algorithm in O2matic samples the last 15 seconds of input from the pulse oximeter and calculates increments or decrements in oxygen flow every second based on the last 15 seconds' average. Increments and decrements are proportionally increased relative to the difference between actual SpO2 and target SpO2. Maximal oxygen flow can be specified to fit the actual condition treated and the device used for delivering oxygen to the patient. O2matic allows for flow up to 15 L/minute in automatic mode, but will in this project be limited to 0-8 L/minute which are the flowrates used for nHFT (see further down). During the study alarms from SpO2 and heart-rate-out-of-range will be silenced and blinded (see further down) as study participants will be monitored using the usual central monitoring system used in the NICU The only alarm allowed will be for loss of signal from the oximetry sensor which can be individualized from 0 to 5 minutes, to avoid repeated alarms due to signal loss of shorter duration. The O2Matic is CE-marked and designed for adult care but not registered for use in patients less than 18 years of age. Consequently, this study also aims to test the use of O2Matic in a new patient group.
The O2Matic is only compatible with the Nonin Purelight pulse oximetry sensors - including Nonin Neonatal Oximetry sensors.
During the intervention the O2Matic will be operating in automatic mode adjusting the oxygen flow in response to changes in SpO2.
During the control period O2Matic will be deactivated.
Nasal High Flow Therapy via AIRVO-2 Nasal high flow therapy (nHFT) is a standard treatment modality in neonatal respiratory care which can be provided using the OptiFlowTM interface from Fischer \& Paykell and a gas source providing a mixture of humidified air and oxygen.
The AIRVO-2TM is a humidifier with an integrated flow generator able to deliver warmed and humidified respiratory gases to spontaneously breathing patients through a variety of specific patient interfaces in varying sizes (OptiFlowTM). In clinical practice AIRVO-2 is used with OptiFlow prongs from size "preterm" and up, although the recommended size is from size "infant".
The AIRVO-2 is designed to be able to deliver flow at a constant set flow rate which will be kept constant regardless of manual changes in the fraction of inspired oxygen (FiO2) - the resulting FiO2 will be shown on the display. When used in this study the AIRVO-2 will be used in junior-mode which is necessary when used with a neonatal interface. In junior-mode humidification-temperature is limited to 34 degrees and airflow to a maximum of 25 L/min but in the current study only up to 8 L/min will be used.
Closed loop adjustment of oxygen via O2Matic and AIRVO-2 Oxygen supply to AIRVO-2 can be delivered by connecting the oxygen output from O2Matic to the oxygen inlet on AIRVO-2. In this way nHFT from AIRVO-2 can be delivered with automatically adjusted oxygen supply via the closed loop system from O2Matic at a constant set-flowrate controlled by AIRVO- 2, with the resulting FiO2 measured and displayed by AIRVO-2. O2Matic will adjust FiO2 based on the reading from the Nonin Purelight pulse oximeter connected to O2Matic. It is important to note, that the reading from this pulse oximeter will be blinded to the clinical staff, and all manual adjustments to FiO2 will be done based on readings from the pulse oximeter connected to the central monitoring system in the NICU (Avant 9600 Nonin Pulsoximeter connected via Philips Intellivue).
Study outline and trial design
The study is a pilot trial and designed as an order-randomized, cross-over trial. Infants will be randomized to treatment-order by block randomization to ensure even distribution between the sequence of treatment. All infants will at study start receive nHFT via OptiFlow interface, and then be allocated to:
- Automated adjustment of FiO2 by O2Matic followed by manual FiO2 adjustment or
- Manual adjustment of FiO2 followed by Automated adjustment of FiO2 by O2Matic
Each patient will serve as their own control, and each treatment-period will last 24 hours, and each patient will be exposed to 1 period of each treatment assignment.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- None (open label)
- Number of arms
- 2
- Model description
- The study is a pilot trial and designed as a order-randomized, cross-over trial. Infants will be randomised to treatment-order by block randomisation to ensure even distribution between the sequence of treatment. All infants will at study start receive nHFT via OptiFlow interface, and then be allocated to: ▪ Automated adjustment of FiO2 by O2Matic followed by manual FiO2 adjustment or ▪ Manual adjustment of FiO2 followed by Automated adjustment of FiO2 by O2Matic Each patient will serve as their own control, and each treatment-period will last 24 hours, and each patient will be exposed to 1 period of each treatment assignment.
| Arm | Type | Receives |
|---|---|---|
| Interventional period: Automated adjustment of FiO2 by O2Matic | Experimental | Device: O2MaticDuring the interventional period the O2Matic will operate in automatic mode using the Neonatal Study Profile. O2Matic will continuously adjust the O2 flow to adjust SpO2 within range based on readings from the pulse oximeter connected to O2Matic, while AIRVO-2 will adjust the flow of ambient air to keep the total gas flow constant. |
| Control period - manual adjustment of FiO2 | No intervention | –During the control period, the bedside nurse will manually change FiO2 as per routine based on the reading from the Avant 9600 Nonin pulse oximeter connected to the central monitoring system), by changing oxygenflow from O2Matic as required to induce appropriate changes in SpO2: |
Who may qualify
- Ages
- Up to 6 months
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child
Key inclusion criteria (2 listed)
- Newborn infants receiving nHFT via Optiflow 4-8 l/min and FiO2>0.25, requiring adjustments of FiO2 beyond the extra need during care procedures
- Likely to be maintained on nHFT during study period of 48 hrs
Key exclusion criteria (4 listed)
- major congenital abnormalities
- hemodynamic instability including large PDA with right to left shunting
- clinician's concern regarding infant stability.
- Unstable infants with frequent apneas, predominantly having need for oxygen during apneic events
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| O2MaticDuring the interventional period the O2Matic will operate in automatic mode using the Neonatal Study Profile. O2Matic will continuously adjust the O2 flow to adjust SpO2 within range based on readings from the pulse oximeter connected to O2Matic, while AIRVO-2 will adjust the flow of ambient air to keep the total gas flow constant. | Device | Interventional period: Automated adjustment of FiO2 by O2Matic |
Primary outcome
time in target SpO2 range 90%-95% (90%-100% if FiO2 =21%)
Time frame: 48 hours
total time spent in target SpO2 range: * measured by the Nonin pulse oximeter connected to O2Matic and/or * measured by the Avant 9600 Nonin Pulse oximeter providing data from this pulse oximeter
9 secondary outcomes
number of episodes of SpO2 below 80% lasting at least 60 seconds
Time frame: 48 hours
relative SpO2 distribution in the ranges <80%, 81-85%, 86-89%, 90-95%, >95%
Time frame: 48 hours
burden of hypoxia, i.e. the 'area under the curve' using spO2 = 80% as the threshold
Time frame: 48 hours
duration of episodes with SpO2 above 95% or below 90%
Time frame: 48 hours
frequency of episodes with SpO2 above 95% or below 90%
Time frame: 48 hours
frequency of FiO2 adjustments recorded by O2Matic both during automated and manual mode
Time frame: 48 hours
number of "manual override" of FiO2 control during automated mode
Time frame: 48 hours
overall mean FiO2
Time frame: 48 hours
overall mean flow
Time frame: 48 hours
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 18 Nov 2023.
- Individual participant dataSharing planned: Yes
Related trials for Pre-Term
RecruitingPhase 3
Selective Antibiotics When Symptoms Develop Versus Universal Antibiotics for Preterm Neonates
Sepsis, PROM, Preterm (Pregnancy)
Active, not recruitingObservational study
Assessment of Cognitive Function in Breast Cancer and Lymphoma Patients Receiving Chemotherapy
Breast Cancer, Lymphoma
Recruiting
The Effect of Breast Milk, 10% and 20% Dextrose on Pain and Physiological Variables During Heel Puncture in Infants
Newborn Care, Pain Management
RecruitingObservational study
Characterization of Diseases With Salivary Gland Involvement
Healthy Volunteer, Sjogren's Syndrome
Not yet recruiting
The Hemodynamic Impact of High-frequency Oscillatory Ventilation and Periodic Sighs in Preterm Infants
Preterm, Respiratory Distress Syndrome in Premature Infant
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Christian Heiring principal investigator
Copenhagen University Hospital, Rigshospitalet
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing O2Matic in people with Pre-Term and Respiratory Distress Syndrome, Newborn, run by Copenhagen University Hospital, Rigshospitalet at 1 site in Denmark.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 18 Nov 2023. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Denmark. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Christian Heiring (+4535453545, christian.heiring@regionh.dk), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
time in target SpO2 range 90%-95% (90%-100% if FiO2 =21%) (time frame: 48 hours). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Nov 2023.