AzTrials
AzTrials

AnesthesiaNCT05644340

Feasibility and Safety Properties of Metabolic Flow Anesthesia Driven by Automated Gas Control in Pediatric Patients

A study testing Speed 8 (Fast balancing gas flow) and Speed 4 (Medium speed balancing gas flow) in people with Anesthesia, run by Istanbul University at 1 site in Turkey (Türkiye).

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Low flow anesthesia was considered to be causing rebreathing, hypoxia and hypercarbia in the past. However, developing technologies made anesthesia ventilators safer. Low flow anesthesia is proved to be safe and cost-effective for almost a decade, and newer anesthetic machines with automated gas flow and metabolic… Read more about this study

Who is it for?
Ages Up to 18 years
Conditions the study is for
Anesthesia
What is being tested?
Speed 8 (Fast balancing gas flow) and Speed 4 (Medium speed balancing gas flow)
Could I receive a placebo?
No, everyone receives an active treatment
How many people
130 participants
Where
1 siteTurkey (Türkiye)
Study dates
16 Dec 2022to 10 Apr 2023
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Up to 18 years
  • All sexes
  • No healthy volunteers
  • Child, Adult

Who may be able to join

  • Pediatric surgery patients
  • Elective or Semielective surgeries
  • Patients suitable for inhalation anesthesia

Who cannot join

  • Emergency surgery
  • Patients who are contraindicated for inhalation anesthesia

Trial locations and contacts

1 site in 1 country.

Turkey (Türkiye)1 site
  • Istanbul University Istanbul Faculty of Medicine

    Istanbul, 34093

Other trials in Turkey (Türkiye)

About this study

Low flow anesthesia was considered to be causing rebreathing, hypoxia and hypercarbia in the past. However, developing technologies made anesthesia ventilators safer. Low flow anesthesia is proved to be safe and cost-effective for almost a decade, and newer anesthetic machines with automated gas flow and metabolic flow anesthesia (<0.3 L/min gas flow) features are now becoming prominent.

The literature still lacks of pediatric data regarding the cost analysis and safety profile of low flow and especially in metabolic flow anesthesia. In this study, it is aimed to observe inhaled agent expenditure of automated gas flow anesthesia which reaches metabolic flow limits in pediatric patients. For that, automated gas flow will be set to provide a desired end-tidal sevoflurane concentration during general anesthesia. Accordingly, inspired fraction of oxygen and air values will be recorded in 15-minute intervals. Primary outcome will be the inhaled agent (sevoflurane) amount wasted in milliliters for both inhaled agent maintenance speed (8-fast and 4-slow). Secondarily, delta value of set and detected inspired fraction of oxygen (DeltaFiO2=DetectedFiO2-SetFiO2) will be analyzed. DeltaFiO2 higher than 5 units will be accepted as "unsafe" gas mixture, and the incidence will be evaluated. Secondary outcomes will also include duration of emergence from anesthesia including both extubation and obeying verbal commands.

Conditions
Anesthesia
Being tested
Speed 8 (Fast balancing gas flow), Speed 4 (Medium speed balancing gas flow)
Keywords
pediatric anesthesia, metabolic flow anesthesia, low flow anesthesia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Speed 8 (Fast balancing gas flow)Procedure or surgery

    General anesthesia will be induced via intravenous agents, and anesthesia maintenance will be provided via inhalation for all the patients. The maintenance will be provided with sevoflurane using automated gas flow with the selected speed of 8. The anesthesia machine indicates amount of sevoflurane inhaled, inspired and exhaled oxygen, carbon dioxyde, air and sevoflurane concentrations. Accordingly these data and actual flow rate will be recorded every 15 minutes.

  • Speed 4 (Medium speed balancing gas flow)Procedure or surgery

    General anesthesia will be induced via intravenous agents, and anesthesia maintenance will be provided via inhalation for all the patients. The maintenance will be provided with sevoflurane using automated gas flow with the selected speed of 4 (Medium speed). The anesthesia machine indicates amount of sevoflurane inhaled, inspired and exhaled oxygen, carbon dioxyde, air and sevoflurane concentrations. Accordingly these data and actual flow rate will be recorded every 15 minutes.

Study groups in NCT05644340
Study groupRoleWhat they receive
Automated Gas Flow Group using speed 8 to reach targeted end-tidal sevoflurane concentrationActive comparatorPediatric patients who are operated under general anesthesia using automated gas flow which is set to speed 8 to achieve targeted end-expiratory sevoflurane concentration (MAC 1.2) will be included in the study. Automated gas flow provides a gas mixture in different proportions which is automatically generated and consists of sevoflurane, oxygen and air. Inspired and end-tidal concentrations of sevoflurane, oxygen and air will be available on the anesthesia ventilator screen which will be recorded accordingly in15-minute intervals.
Receives: Procedure: Speed 8 (Fast balancing gas flow)
Automated Gas Flow Group using speed 4 to reach targeted sevoflurane concentrationActive comparatorPediatric patients who are operated under general anesthesia using automated gas flow which is set to speed 4 to achieve targeted end-expiratory sevoflurane concentration (MAC 1.2) will be included in the study. Automated gas flow provides a gas mixture in different proportions which is automatically generated and consists of sevoflurane, oxygen and air. Inspired and end-tidal concentrations of sevoflurane, oxygen and air will be available on the anesthesia ventilator screen which will be recorded accordingly in15-minute intervals.
Receives: Procedure: Speed 4 (Medium speed balancing gas flow)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Total amount of sevoflurane consumed

    At the end of the surgery, total amount of sevoflurane, which is indicated on the anesthesia machine screen, will be recorded in milliliters

    Measured: up to 3 hours

Secondary outcomes (3)
  1. Time to extubation after inhalation anesthesia stop

    Time between the inhalation anesthesia stop and extubation in minutes

    Measured: Up to 45 minutes

  2. Time to cooperation after inhalation anesthesia stop

    Time between the inhalation anesthesia stop and cooperation to verbal impulses in minutes

    Measured: Up to 2 hours

  3. Delta Oxygen Concentration

    The adjusted oxygen fraction (generally 40%) minus the actual inhaled oxygen fraction will provide the delta value. The data will be recorded every 15-minute during the surgery, and delta >%5 will be considered as "unsafe"

    Measured: up to 2 hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Dec 2022
  2. Study start16 Dec 2022
  3. Primary completion10 Apr 2023
  4. Study completion10 Apr 2023

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Screening
Allocation
Non-randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
130 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05644340
Sponsor's protocol ID
2019/154
Status last verified
Apr 2023
First submitted
29 Nov 2022
Last updated
11 Apr 2023
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing Speed 8 (Fast balancing gas flow) and Speed 4 (Medium speed balancing gas flow) in people with Anesthesia, run by Istanbul University at 1 site in Turkey (Türkiye).

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 11 Apr 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Total amount of sevoflurane consumed (time frame: up to 3 hours). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 Apr 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in