AzTrials
AzTrials

Artificial; Complications, HeartNCT05644405

Stroke Volume Variations and Pulse Pressure Variations Undergoing Artificial Pneumothorax Surgery

A study testing FloTrac Vigileo in people with Artificial; Complications, Heart, run by Chinese PLA General Hospital at 1 site in China.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Stroke volume variation (SVV) and pulse pressure variation (PPV) have been thought to be sensitive predictors of fluid responsiveness in mechanically ventilated participants. In this paper, the investigators reported a special group of people to use SVV and PPV during their operation. Read more about this study

Who is it for?
Ages 18 to 65 yearsHealthy volunteers can take part
Conditions the study is for
Artificial; Complications, Heart
What is being tested?
FloTrac Vigileo
How many people
6 participants
Where
1 siteChina
Study dates
1 Jul 2021to 15 Nov 2022
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 65 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Must be arranged for thoracoscopic surgical treatment of esophageal cancer Must be mechanically ventilated with artificial Pneumothorax during the operation Must be normal in Allen test.

Who cannot join

  • Hypertension Coronary heart disease Arrhythmia Left ventricle ejection fractions < 50% (EF<50%) Pulmonary hypertension Congenital cardiovascular malformation Peripheral vascular disease Long-term history of oral vasoactive drugs

Trial locations and contacts

1 site in 1 country.

China1 site
  • The Sixth Medical Center of Chinese PLA General Hospital

    Beijing, Beijing Municipality, 100048

Other trials in China

About this study

Official title: Accuracy of Stroke Volume Variation and Pulse Pressure Variation to Predict Fluid Responsiveness in Patients With Artificial Pneumothorax During Esophageal Surgery

Stroke volume variation (SVV) and pulse pressure variation (PPV) have been thought to be sensitive predictors of fluid responsiveness in mechanically ventilated participants. In this paper, the investigators reported a special group of people to use SVV and PPV during their operation. The maintenance of hemodynamic stability and the critical organ perfusion is crucial to the treatment for patients with artificial Pneumothorax during esophageal surgery, because artificial pneumothorax causes incomplete ventilation of one lung. In addition, artificial pneumothorax may seriously affect theparticipant's heart and lung function, brings more challenges to the intraoperative anesthetic management, expecially in volume management. Little information is available about the accuracy of SVV and PPV to predict fluid responsiveness in participants with artificial Pneumothorax during esophageal surgery. It is unclear whether it will affect the accuracy of SVV and PPV, and whether it will cause the change of their threshold values. The investigators will discuss it in the passage and the investigators will give an preliminary mechanism to explain the results.

Read the detailed description

Backgroud: This study aims to evaluate the ability of stroke volume variation (SVV) and pulse pressure variation (PPV) to predict fluid responsiveness in mechanically ventilated participants with artificial Pneumothorax during esophageal surgery.

Methods: 40 participants, diagnosed with esophageal cancer, undergoing thoracoscopic radical resection of esophageal cancer were studied. All the participants used Vigileo/FloTrac system for analysis. Haemodynamic data such as MAP, HR, SV, SVI, CO, CI, SVV, PPV were recorded before and after volume expansion (VE). Fluid responsiveness was defined as an increase in SVI≥10%(△SVI≥10%). Participants were divided into Responders and Non-responders by changes in △SVI ≥10% and < 10%. Nonparametric Wilcoxon rank sum test was used to compare the hemodynamic parameters of Responders and Non-responders before and after VE. Pearson correlation analysis was used to analyze the values of SVV, PPV and △SVI. The receiver operating characteristic (ROC) curve of each hemodynamic index was drawn to determine its accuracy and threshold.

Being tested
FloTrac Vigileo

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • FloTrac VigileoDiagnostic test

    A dedicated transducer (FloTrac TM, Edwards Lifesciences, LLC, Irvine, CA, USA) was connected to the radial arterial line on one side and to the Vigileo System (Vigileo TM Edwards Lifesciences, LLC, Irvine, CA, USA) on the other side

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The area under the receiver operating characteristic (ROC) curve

    According to the area under the curve, the predictive ability and the diagnostic thresholds of SVV and PPV were determined. The p value less than 0.05 was regarded as statistically significant.

    Measured: 1YEARS

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Dec 2022
  2. Study start1 Jul 2021
  3. Primary completion20 Sep 2022
  4. Study completion15 Nov 2022

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
6 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05644405
Sponsor's protocol ID
CY2022-01
Status last verified
Dec 2022
First submitted
19 Nov 2022
Last updated
9 Dec 2022
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: We don't want to share plan

Publications

  • Choi KH, Shim JK, Kim DW, Byun CS, Park JH. Dynamic Indices Fail to Predict Fluid Responsiveness in Patients Undergoing One-Lung Ventilation for Thoracoscopic Surgery. J Clin Med. 2021 May 27;10(11):2335. doi: 10.3390/jcm10112335.

    PubMed 34071746
  • Chuang KH, Lai HH, Chen Y, Chen LC, Lu HI, Chen YH, Li SH, Lo CM. Improvement of surgical complications using single-lumen endotracheal tube intubation and artificial carbon dioxide pneumothorax in esophagectomy: a meta-analysis. J Cardiothorac Surg. 2021 Apr 21;16(1):100. doi: 10.1186/s13019-021-01459-1.

    PubMed 33882958

Questions about this trial

What is this clinical trial studying?

A study testing FloTrac Vigileo in people with Artificial; Complications, Heart, run by Chinese PLA General Hospital at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 9 Dec 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The area under the receiver operating characteristic (ROC) curve (time frame: 1YEARS). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05644405, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Dec 2022.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in