Head and Neck CancerNCT05666193
On-treatment Adaptation of Head and Neck Cancer Dosimetry Plans Using Novel Cone-beam CT and AI-driven Software
A study testing CBCT Imaging in people with Head and Neck Cancer, run by Varian, a Siemens Healthineers Company at 1 site in Canada.
Trial summary
This is a feasibility study investigating the use of a high-performance HyperSight cone beam CT (CBCT) and adaptive planning software for both online and offline radiotherapy treatment planning for head and neck cancer. Read more about this study
- Who is it for?
- Ages 19 years and older
- Conditions the study is for
- Head and Neck Cancer
- What is being tested?
- CBCT Imaging
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 30 participants
- Where
- 1 siteCanada
- Study dates
- 10 Jul 2023to 19 Dec 2024
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 19 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patient age ≥ 19
- Patient is scheduled for treatment on one of the five TrueBeam platforms at the NS Health QE2 site.
- Patient is receiving radiation therapy for cancer of the head and neck involving a target in either the ipsilateral or bilateral neck, with a minimum of 21 fractions.
Who cannot join
- Patient is pregnant or has plans for pregnancy during the period of treatment.
- Patient is unwilling to consent to participating to the study, or for whom informed consent is not possible.
- Patient has previously undergone radiation therapy to the oral cavity or sinuses.
- Patient has had either a bilateral neck dissection and/or laryngectomy.
Trial locations and contacts
1 site in 1 country.
About this study
This is a feasibility study investigating the use of a high-performance HyperSight cone beam CT (CBCT) and adaptive planning software for both online and offline radiotherapy treatment planning for head and neck cancer.
Read the detailed description
This study focuses on imaging and radiotherapy treatment plan modification for head \& neck cancer patients using a high-performance cone beam CT (CBCT) image guidance system (HyperSight) and AI-driven adaptive planning software. The HyperSight imaging system is a forthcoming component of a radiation therapy (RT) treatment platform, called Ethos (Varian Medical Systems).
RT is used in the treatment of approximately 75% of all head and neck (H\&N) cancers with either curative or palliative intent. External beam radiation therapy is typically delivered over 5-7 weeks in 25-35 daily treatments (or "fractions"). Image guided radiation therapy (IGRT) is now a standard of care for external beam radiotherapy. During an IGRT treatment session, a CBCT imaging system built into the treatment unit is used to acquire 3D images of the patient's anatomy immediately prior to, and, if required, at several time points during, the daily delivery of radiation. The CBCT image data are used by the treatment team to carefully align the patient to a treatment planning fan-beam CT (FBCT) images that was acquired 1-2 weeks prior to the start of treatment, and which was used to generate the dosimetry plan that determines the daily radiation delivery. Verification of the patient position and alignment with the treatment planning images increases the precision of radiation delivery.
Daily imaging is particularly important for accurate setup of patients treated for head and neck (H\&N) cancer, as these patients often experience weight loss and target volume changes throughout the course of treatment. These volume changes can alter the expected dose distribution, as organs at risk (OAR) migrate to high dose regions or target volumes develop inhomogeneities. When volume changes are perceived by the treatment team to have a significant impact on radiation delivery, patients may be sent for a second planning FBCT and have a new treatment plan created for the remainder of their treatment. This process is referred to as offline replanning or offline adaptation. The radiation oncologist must decide whether to pause treatment or continue with the original treatment plan until a new plan is created. In either case, it can take several days between the point when an issue is identified and when a new plan is ready to be delivered. Offline replanning is not a regularly scheduled part of the clinical workflow and creates disruption of routine imaging, contouring and planning tasks for other patients. These tasks must be moved aside to free the necessary resources to create a new plan for the patient who is already receiving treatment and to permit the treatment team to start delivering the new plan as soon as possible.
The CBCT images acquired with the high-performance HyperSight CBCT imaging system have demonstrated Hounsfield Unit accuracy sufficient for accurate dosimetry calculations in phantoms. These images can therefore potentially be used to plan, or re-plan a radiation treatment delivery. The ability to use imaging that is acquired as part of the daily treatment delivery for re-planning could reduce the need to send patients for additional imaging and could also reduce the time and resources required to re-plan treatment delivery mid-course. This is of great importance for a cohort of patients already known to be vulnerable to the need for replanning.
In addition to the challenges involved in mid-treatment re-planning, another issue commonly encountered in H\&N patients is the presence of imaging artifacts from high-density metal objects in their oral cavity such as dental fillings and implants. These artifacts can cause difficulties in visualization of target volumes and OARs on planning CT as well as perturbation of dose calculation, particularly for cancers in the oral cavity. Metal artifacts can also cause a significant reduction in CBCT image quality, limiting the usefulness of IGRT for patient positioning.
The HyperSight CBCT imaging system incorporates several hardware and software changes that have the potential to provide higher quality CBCT images including improved visualization of volume changes and improved metal artifact reduction.
With minimal disruption for participating patients, this study will enable a comparison of (i) the patient's treatment planning FBCT and (ii) the patient's conventional CBCT on an existing treatment unit (Truebeam CBCT) with (iii) patient CBCT images on the HyperSight system. Image quality of the high performance CBCT will thereby be compared to both a best-case standard (FBCT) and the conventional CBCT for IGRT (Truebeam CBCT) to identify potential improvements in the HyperSight CBCT images. Image quality will be quantified in terms of contrast-to-noise ratio (CNR), resolution, Hounsfield Unit (HU) accuracy and artifact reduction with a focus on anatomy germane to the image guidance task. A qualitative assessment of the different image datasets will also be performed through feedback from multiple observers (radiation oncologists and radiation therapists). Radiation doses to key targets and organs at risk will be calculated from the high performance CBCTs and compared to the doses calculated in the subject's treatment plan to determine the suitability of the CBCT images for RT dosimetric planning. Various re-planning scenarios will also be examined to determine potential increases in efficiency from using the HyperSight CBCT imaging system for re-planning.
Image sets (i) and (ii) above are already acquired as part of standard-of-care for radiation treatment. Two additional CBCTs, taken on the day of the patient's treatment planning FBCT and again on the day the patients receive their 21st treatment fraction (approximately two-thirds through treatment) will be acquired from each subject on the HyperSight CBCT imaging system for this study. Not every patient will require mid-treatment re-planning but based on prior institutional data, if re-planning is required, the indications for re-planning should be evident in most of that population by the time 2/3 of their treatment has been delivered. If the treatment team determines that a patient requires a second planning FBCT during treatment, the patient will be scheduled for a third HyperSight CBCT on the same day that they receive their second planning FBCT.
Radiation treatment planning and delivery will not be altered due to patients' participation in this study. Patients will receive radiotherapy according to current departmental procedures and on the department's existing linear accelerator platforms. The decision to obtain a second planning CT and to generate a new mid-treatment plan will not be affected by a subject's participation in the study.
The HyperSight CBCTs that are acquired in this study will allow the examination of several re-planning strategies. The process of mid-treatment re-planning can be simulated for all subjects using the HyperSight CBCT acquired at fraction 21. Timing and workflow efficiencies can be evaluated in these simulated re-planning processes and compared to institutional norms (e.g., average time from identification of the need for re-planning to the start of delivery of a new treatment plan). In the subset of study subjects who require re-planning as part of their treatment, the HyperSight CBCTs acquired on the day of the second FBCT will also be used to generate a treatment plan and the dosimetry of the HyperSight CBCT-based re-plan will be compared to the dosimetry of the mid-treatment re-plans generated for these subjects using the current offline re-planning methods.
In addition to the simulation of current offline re-planning methods using the HyperSight CBCT images, this study will evaluate the online adaptive workflow that is available through the Ethos Radiotherapy System. Online adaptive workflow leverages AI-based anatomical structure contouring and plan optimization tools to adjust the daily radiation treatment delivery. Instead of delivering the same treatment in every fraction, the treatment plan defined prior to the start of treatment is optimized based on the anatomy captured in the CBCT acquired at the start of the daily fraction. Independent of the patient's clinical treatment plan, the AI-driven adaptive planning component of Ethos will be used to simulate online adaptation of the treatment plan. This study will evaluate the potential dosimetric benefits of daily online adaptive planning in Head and Neck cancer and the potential for online adaptation to reduce the need for offline re-planning. The time and resources required to implement an online adaptive workflow will be compared to standard IGRT delivery.
- Conditions
- Head and Neck Cancer
- Being tested
- CBCT Imaging
- Medical subject headings
- Head and Neck Neoplasms
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
CBCT ImagingDevice
Subjects are scheduled for two imaging sessions on the Ethos system with the HyperSight CBCT. One session is on the same day as the CT simulation scan for treatment planning. The second session is on the same day as the delivery of ther 21st treatment fraction. If the subject is sent for a mid-treatment FBCT for re-planning, a third HyperSight CBCT imaging session will be scheduled on the same day as the mid-treatment FBCT.
| Study group | Role | What they receive |
|---|---|---|
| HyperSight Imaging Arm | Experimental | Subjects imaged with the new HyperSight CBCT imaging system. Receives: Device: CBCT Imaging |
What is being measured
The primary outcome is the main question the study is designed to answer.
Evaluation of CBCT-based dosimetry calculations
The treatment plan calculated on a subject's fan beam simulation CT will be re-calculated on both the HyperSight CBCT acquired on the day of the subject's simulation CT and on the TrueBeam CBCT used for subject positioning during fraction 1 of treatment delivery. Dose-volume histograms for targets and key organs at risk will be compared between the three dose calculations from each subject.
Measured: 1 day
Evaluate potential reduction in time and resources required for offline plan adaptation
The workflow and opportunity for improved efficiency when using HyperSight CBCT images for offline treatment adaptation, will be compared to the standard process of obtaining a separate FBCT for re-planning. The average time required to generate a revised treatment plan will be measured and compared to institutional norms.
Measured: 4 weeks
Improvements in radiation dosimetry from using online adaptation
The HyperSight CBCT acquired on the same day as the subject's 21st treatment fraction delivery will be used to simulate an online adaptive radiotherapy session, which will produce a treatment plan that is adapted to the anatomy as it appears on that day. The target dose coverage and doses delivered to key organs at risk in the adaptive plan will be compared to the doses that are delivered to those structures by the subject's initial treatment plan.
Measured: 4 weeks
Qualitative assessment of CBCT imaging
Paired HyperSight CBCT and Truebeam CBCT images will be presented to radiation oncologists and radiation therapists, who will rank the images using a Likert scale for the ability to identify significant anatomical structure volume changes that prompt the need for on-treatment replanning.
Measured: 4 weeks
Secondary outcomes (2)
CBCT image quality
The quality of HyperSight CBCT images will be evaluated my measuring contrast-to-noise ratio, resolution, and Hounsfield Unit accuracy. The quality metrics of the HyperSight CBCT images will be compared to those of the fan beam planning CT images and to those of the standard TrueBeam CBCT images. Metal artifact reduction will be compared between images of subjects with dental or other metal implants in the imaging field.
Measured: 4 weeks
Patient experience questionnaire
Subjects will be presented with a questionnaire in which they will be asked to compare their experience of imaging on a fan beam planning CT system to their experience of imaging with the HyperSight CBCT imaging system.
Measured: 1 day
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted27 Dec 2022
- Study start10 Jul 2023
- Primary completion19 Dec 2024
- Study completion19 Dec 2024
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Head and Neck CancerStudies of the same condition, open and under way.
- More trials run by Varian, a Siemens Healthineers CompanyThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- This is a prospective, single-arm, single-site feasibility study designed to generate data describing the quality and applicability of on-couch high-performance CBCT imaging technology during external beam radiation therapy for head and neck cancer patients.
- Masking
- None (open label)
- Enrolment
- 30 participants (actual)
Sponsor and investigators
- Lead sponsor
- Varian, a Siemens Healthineers Company
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05666193
- Sponsor's protocol ID
- VAR-2022-06
- Status last verified
- Feb 2025
- First submitted
- 5 Dec 2022
- Last updated
- 4 Feb 2025
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 4 Feb 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- On-treatment Adaptation of Head and Neck Cancer Dosimetry Plans Using Novel Cone-beam CT and AI-driven Software
- ClinicalTrials.gov ID
- NCT05666193
- Acronym / sponsor ID
- VAR-2022-06
- Conditions
- Head and Neck Cancer
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 30 participants (actual)
- Lead sponsor
- Varian, a Siemens Healthineers CompanyIndustry (pharma, biotech, devices)
- Study start
- 10 Jul 2023 (actual)
- Primary completion
- 19 Dec 2024 (actual)
- Study completion
- 19 Dec 2024 (actual)
- First posted
- 27 Dec 2022 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This is a feasibility study investigating the use of a high-performance HyperSight cone beam CT (CBCT) and adaptive planning software for both online and offline radiotherapy treatment planning for head and neck cancer.
Detailed description
This study focuses on imaging and radiotherapy treatment plan modification for head \& neck cancer patients using a high-performance cone beam CT (CBCT) image guidance system (HyperSight) and AI-driven adaptive planning software. The HyperSight imaging system is a forthcoming component of a radiation therapy (RT) treatment platform, called Ethos (Varian Medical Systems).
RT is used in the treatment of approximately 75% of all head and neck (H\&N) cancers with either curative or palliative intent. External beam radiation therapy is typically delivered over 5-7 weeks in 25-35 daily treatments (or "fractions"). Image guided radiation therapy (IGRT) is now a standard of care for external beam radiotherapy. During an IGRT treatment session, a CBCT imaging system built into the treatment unit is used to acquire 3D images of the patient's anatomy immediately prior to, and, if required, at several time points during, the daily delivery of radiation. The CBCT image data are used by the treatment team to carefully align the patient to a treatment planning fan-beam CT (FBCT) images that was acquired 1-2 weeks prior to the start of treatment, and which was used to generate the dosimetry plan that determines the daily radiation delivery. Verification of the patient position and alignment with the treatment planning images increases the precision of radiation delivery.
Daily imaging is particularly important for accurate setup of patients treated for head and neck (H\&N) cancer, as these patients often experience weight loss and target volume changes throughout the course of treatment. These volume changes can alter the expected dose distribution, as organs at risk (OAR) migrate to high dose regions or target volumes develop inhomogeneities. When volume changes are perceived by the treatment team to have a significant impact on radiation delivery, patients may be sent for a second planning FBCT and have a new treatment plan created for the remainder of their treatment. This process is referred to as offline replanning or offline adaptation. The radiation oncologist must decide whether to pause treatment or continue with the original treatment plan until a new plan is created. In either case, it can take several days between the point when an issue is identified and when a new plan is ready to be delivered. Offline replanning is not a regularly scheduled part of the clinical workflow and creates disruption of routine imaging, contouring and planning tasks for other patients. These tasks must be moved aside to free the necessary resources to create a new plan for the patient who is already receiving treatment and to permit the treatment team to start delivering the new plan as soon as possible.
The CBCT images acquired with the high-performance HyperSight CBCT imaging system have demonstrated Hounsfield Unit accuracy sufficient for accurate dosimetry calculations in phantoms. These images can therefore potentially be used to plan, or re-plan a radiation treatment delivery. The ability to use imaging that is acquired as part of the daily treatment delivery for re-planning could reduce the need to send patients for additional imaging and could also reduce the time and resources required to re-plan treatment delivery mid-course. This is of great importance for a cohort of patients already known to be vulnerable to the need for replanning.
In addition to the challenges involved in mid-treatment re-planning, another issue commonly encountered in H\&N patients is the presence of imaging artifacts from high-density metal objects in their oral cavity such as dental fillings and implants. These artifacts can cause difficulties in visualization of target volumes and OARs on planning CT as well as perturbation of dose calculation, particularly for cancers in the oral cavity. Metal artifacts can also cause a significant reduction in CBCT image quality, limiting the usefulness of IGRT for patient positioning.
The HyperSight CBCT imaging system incorporates several hardware and software changes that have the potential to provide higher quality CBCT images including improved visualization of volume changes and improved metal artifact reduction.
With minimal disruption for participating patients, this study will enable a comparison of (i) the patient's treatment planning FBCT and (ii) the patient's conventional CBCT on an existing treatment unit (Truebeam CBCT) with (iii) patient CBCT images on the HyperSight system. Image quality of the high performance CBCT will thereby be compared to both a best-case standard (FBCT) and the conventional CBCT for IGRT (Truebeam CBCT) to identify potential improvements in the HyperSight CBCT images. Image quality will be quantified in terms of contrast-to-noise ratio (CNR), resolution, Hounsfield Unit (HU) accuracy and artifact reduction with a focus on anatomy germane to the image guidance task. A qualitative assessment of the different image datasets will also be performed through feedback from multiple observers (radiation oncologists and radiation therapists). Radiation doses to key targets and organs at risk will be calculated from the high performance CBCTs and compared to the doses calculated in the subject's treatment plan to determine the suitability of the CBCT images for RT dosimetric planning. Various re-planning scenarios will also be examined to determine potential increases in efficiency from using the HyperSight CBCT imaging system for re-planning.
Image sets (i) and (ii) above are already acquired as part of standard-of-care for radiation treatment. Two additional CBCTs, taken on the day of the patient's treatment planning FBCT and again on the day the patients receive their 21st treatment fraction (approximately two-thirds through treatment) will be acquired from each subject on the HyperSight CBCT imaging system for this study. Not every patient will require mid-treatment re-planning but based on prior institutional data, if re-planning is required, the indications for re-planning should be evident in most of that population by the time 2/3 of their treatment has been delivered. If the treatment team determines that a patient requires a second planning FBCT during treatment, the patient will be scheduled for a third HyperSight CBCT on the same day that they receive their second planning FBCT.
Radiation treatment planning and delivery will not be altered due to patients' participation in this study. Patients will receive radiotherapy according to current departmental procedures and on the department's existing linear accelerator platforms. The decision to obtain a second planning CT and to generate a new mid-treatment plan will not be affected by a subject's participation in the study.
The HyperSight CBCTs that are acquired in this study will allow the examination of several re-planning strategies. The process of mid-treatment re-planning can be simulated for all subjects using the HyperSight CBCT acquired at fraction 21. Timing and workflow efficiencies can be evaluated in these simulated re-planning processes and compared to institutional norms (e.g., average time from identification of the need for re-planning to the start of delivery of a new treatment plan). In the subset of study subjects who require re-planning as part of their treatment, the HyperSight CBCTs acquired on the day of the second FBCT will also be used to generate a treatment plan and the dosimetry of the HyperSight CBCT-based re-plan will be compared to the dosimetry of the mid-treatment re-plans generated for these subjects using the current offline re-planning methods.
In addition to the simulation of current offline re-planning methods using the HyperSight CBCT images, this study will evaluate the online adaptive workflow that is available through the Ethos Radiotherapy System. Online adaptive workflow leverages AI-based anatomical structure contouring and plan optimization tools to adjust the daily radiation treatment delivery. Instead of delivering the same treatment in every fraction, the treatment plan defined prior to the start of treatment is optimized based on the anatomy captured in the CBCT acquired at the start of the daily fraction. Independent of the patient's clinical treatment plan, the AI-driven adaptive planning component of Ethos will be used to simulate online adaptation of the treatment plan. This study will evaluate the potential dosimetric benefits of daily online adaptive planning in Head and Neck cancer and the potential for online adaptation to reduce the need for offline re-planning. The time and resources required to implement an online adaptive workflow will be compared to standard IGRT delivery.
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- This is a prospective, single-arm, single-site feasibility study designed to generate data describing the quality and applicability of on-couch high-performance CBCT imaging technology during external beam radiation therapy for head and neck cancer patients.
| Arm | Type | Receives |
|---|---|---|
| HyperSight Imaging Arm | Experimental | Device: CBCT ImagingSubjects imaged with the new HyperSight CBCT imaging system. |
Who may qualify
- Ages
- 19 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Patient age ≥ 19
- Patient is scheduled for treatment on one of the five TrueBeam platforms at the NS Health QE2 site.
- Patient is receiving radiation therapy for cancer of the head and neck involving a target in either the ipsilateral or bilateral neck, with a minimum of 21 fractions.
Key exclusion criteria (4 listed)
- Patient is pregnant or has plans for pregnancy during the period of treatment.
- Patient is unwilling to consent to participating to the study, or for whom informed consent is not possible.
- Patient has previously undergone radiation therapy to the oral cavity or sinuses.
- Patient has had either a bilateral neck dissection and/or laryngectomy.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| CBCT ImagingSubjects are scheduled for two imaging sessions on the Ethos system with the HyperSight CBCT. One session is on the same day as the CT simulation scan for treatment planning. The second session is on the same day as the delivery of ther 21st treatment fraction. If the subject is sent for a mid-treatment FBCT for re-planning, a third HyperSight CBCT imaging session will be scheduled on the same day as the mid-treatment FBCT. | Device | HyperSight Imaging Arm |
Primary outcome
Evaluation of CBCT-based dosimetry calculations
Time frame: 1 day
The treatment plan calculated on a subject's fan beam simulation CT will be re-calculated on both the HyperSight CBCT acquired on the day of the subject's simulation CT and on the TrueBeam CBCT used for subject positioning during fraction 1 of treatment delivery. Dose-volume histograms for targets and key organs at risk will be compared between the three dose calculations from each subject.
Evaluate potential reduction in time and resources required for offline plan adaptation
Time frame: 4 weeks
The workflow and opportunity for improved efficiency when using HyperSight CBCT images for offline treatment adaptation, will be compared to the standard process of obtaining a separate FBCT for re-planning. The average time required to generate a revised treatment plan will be measured and compared to institutional norms.
Improvements in radiation dosimetry from using online adaptation
Time frame: 4 weeks
The HyperSight CBCT acquired on the same day as the subject's 21st treatment fraction delivery will be used to simulate an online adaptive radiotherapy session, which will produce a treatment plan that is adapted to the anatomy as it appears on that day. The target dose coverage and doses delivered to key organs at risk in the adaptive plan will be compared to the doses that are delivered to those structures by the subject's initial treatment plan.
Qualitative assessment of CBCT imaging
Time frame: 4 weeks
Paired HyperSight CBCT and Truebeam CBCT images will be presented to radiation oncologists and radiation therapists, who will rank the images using a Likert scale for the ability to identify significant anatomical structure volume changes that prompt the need for on-treatment replanning.
2 secondary outcomes
CBCT image quality
Time frame: 4 weeks
Patient experience questionnaire
Time frame: 1 day
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 4 Feb 2025.
- Individual participant dataSharing planned: No
Related trials for Head and Neck Cancer
RecruitingPhase 1/2
Study of INBRX-106 and INBRX-106 in Combination With Pembrolizumab (Keytruda®) in Subjects With Locally Advanced or Metastatic Solid Tumors (Hexavalent OX40 Agonist)
Solid Tumor, Non-Small Cell Lung Cancer
RecruitingObservational study
Proton Re-irradiation in Patients With Recurrent or Second Primary Head and Neck Cancer , a Multicentre Phase II Single Arm Trial
Head & Neck Cancer
RecruitingPhase 2/3
Multicenter Validation Trial of [18F]AlF-FAPI-74 for PET Imaging of Cancer-associated Fibroblasts Through Fibroblast Activation Protein Inhibitors (FAPI) in Different Tumor Types
Oesophageal Cancer, Gastric Cancer
RecruitingPhase 2
Proton Spatially Fractionated Radiotherapy or Photon Stereotactic Body Radiotherapy in Combination With Pembrolizumab Before Surgery for the Treatment of Locally Advanced and Radiation-Naive Locoregionally Recurrent Oral Cavity Cancer, OSPRI Trial
Locally Advanced Oral Cavity Squamous Cell Carcinoma, Locally Recurrent Oral Cavity Squamous Cell Carcinoma
RecruitingPhase 4
Lidocaine Infiltration and Neuroimmunomodulation in Head and Neck Cancer Surgery
Head and Neck Cancer (H&N)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing CBCT Imaging in people with Head and Neck Cancer, run by Varian, a Siemens Healthineers Company at 1 site in Canada.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 4 Feb 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Evaluation of CBCT-based dosimetry calculations (time frame: 1 day). The study lists 4 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Feb 2025.