AzTrials
AzTrials

Diabetes Mellitus, Type 2NCT05666479

CGM Monitoring in T2DM Patients Undergoing Orthopaedic Replacement Surgery

An observational study of Diabetes Mellitus, Type 2 and Arthroplasty, Replacement, Hip, run by Stony Brook University at 1 site in United States.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The purpose of this study is to analyze the efficacy and accuracy of real-time continuous glucose monitoring devices (rtCGM) in patients with Type 2 diabetes undergoing inpatient elective hip or knee surgery in the pre-, peri-, and post-operative setting at Stony Brook University Hospital (SBUH). Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Dexcom G6 Pro Continuous Glucose Monitor (CGM)
Type of treatment
Medical device
How many people
32 participants
Where
1 siteUnited States
Study dates
9 Sep 2022to Sep 2024
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Patients with type 2 diabetes undergoing orthopaedic hip or knee replacement surgery.

Who may be able to join

  • Greater than or equal to 18 years of age
  • Scheduled for elective inpatient hip or knee replacement surgery at Stony Brook University Hospital (SBUH)
  • Clinically diagnosed Type 2 Diabetes at least 6 months prior to surgery
  • Literate and able to provide written informed consent
  • Negative pregnancy test by serum or urine HCG at screening [as documented in subject's medical record) for women of childbearing potential (WCBP)]

Who cannot join

  • Less than 18 years of age
  • Not scheduled for elective inpatient hip or knee replacement surgery at SBUH
  • No clinical diagnosis of Type 2 diabetes at least 6 months prior to surgery
  • Not literate or unable to provide written informed consent
  • Documented diagnosis of organ failure
  • Documented diagnosis of chronic infection
Show all 9Show fewer
  • Documented diagnosis of any active malignancy
  • Documented diagnosis of hepatic (liver) dysfunction or cirrhosis
  • Pregnant by serum or urine HCG at screening [as documented in subject's medical record) for women of childbearing potential (WCBP)]

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Stony Brook University

    Stony Brook, New York, 11794

Other trials in United States

About this study

Official title: Clinical Effectiveness of Continuous Blood Glucose Monitoring In Patients With Type 2 Diabetes Undergoing Orthopaedic Hip or Knee Replacement Surgery

The purpose of this study is to analyze the efficacy and accuracy of real-time continuous glucose monitoring devices (rtCGM) in patients with Type 2 diabetes undergoing inpatient elective hip or knee surgery in the pre-, peri-, and post-operative setting at Stony Brook University Hospital (SBUH).

Being tested
Dexcom G6 Pro Continuous Glucose Monitor (CGM)
Keywords
Type 2 Diabetes, Orthopaedic Hip Replacement, Orthopaedic Knee Replacement, Continuous Blood Glucose Monitoring
Medical subject headings
Diabetes Mellitus, Type 2

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Dexcom G6 Pro Continuous Glucose Monitor (CGM)Device

    A DexCom G6 CGM will be implanted on the subject's abdomen contralateral to the surgical site (i.e. left abdomen for right knee or right hip replacements) no less than 30 cm from the surgical site. This CGM shall be termed "primary" for study purposes. Subjects will wear the primary DexCom G6 CGM for the entirety of the following 10-day timeline: 3/4-days pre-operative, day of hip or knee replacement surgery, and 5/6-day postoperative recovery.

    A second CGM will be implanted in subjects postoperatively while in the Post Anesthesia Care Unit (PACU). This CGM, termed "secondary" for study purposes, will be implanted immediately adjacent to the primary CGM. Subjects will wear the secondary DexCom CGM for the 7 days: day of hip or knee replacement surgery (postoperatively) and 5/6-day postoperative recovery.

Study groups in NCT05666479
Study groupRoleWhat they receive
Patients with Type 2 Diabetes Undergoing Orthopaedic Hip or Knee Replacement SurgeryNot described
Receives: Device: Dexcom G6 Pro Continuous Glucose Monitor (CGM)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Accuracy of Real-Time Continuous Glucose Monitoring

    Analyze data from real-time continuous glucose monitoring and point-of-care glucose monitoring (POC-BG). rtCGM data will be matched and compared to POC-BG collected for standard clinical care in the pre-op and post-op settings (i.e. mealtimes, bedtime, and every 6 hours).

    Measured: 10 days

Secondary outcomes (2)
  1. Interference of Intraoperative Electrocautery on Real-Time Continuous Glucose Monitoring

    Analyze intraoperative rtCGM. Electrocautery, a common surgical technique using electrical current to mitigate bleeding by thermal damage of tissue, may emit electrical pulses which adversely interfere with the measurement and/or data transmission of the rtCGM device. All data points collected during the 60-90-minute operative window will be analyzed for interference, aberrant, or missing values.

    Measured: 60-90 minutes

  2. Assess Irreversible Damage/Interference of Real-Time Continuous Glucose Monitoring Devices Caused by Electrocautery

    Assess irreversible damage/interference of rtCGMs caused by electrocautery. In the postoperative setting, a second rtCGM will be implanted on patients. Data sets between the two rtCGMs will be analyzed for statistically significant mean absolute relative difference (MARD).

    Measured: 6-7 days

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted27 Dec 2022
  2. Study start9 Sep 2022
  3. Primary completion30 Apr 2024 (estimated)
  4. Study completionSep 2024 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Prospective
Enrolment
32 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05666479
Sponsor's protocol ID
IRB2021-00351
Status last verified
Apr 2024
First submitted
17 Dec 2022
Last updated
19 Apr 2024
Results posted
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

An observational study of Diabetes Mellitus, Type 2 and Arthroplasty, Replacement, Hip, run by Stony Brook University at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 19 Apr 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Accuracy of Real-Time Continuous Glucose Monitoring (time frame: 10 days). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Apr 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in