AzTrials
AzTrials

Intraocular LensCLAINTNCT05697978

Distance and Intermediate Visual Acuity in Patients With Implanted Monofocal Negative Aspheric Intraocular Lens

A study testing Monofocal intraocular lens Clareon (Alcon LLC) in people with Intraocular Lens, run by Faculty Hospital Kralovske Vinohrady at 3 sites in Czechia.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

To get the visual outcomes for distance and intermediate and binocular defocus curve in patients with implanted monofocal intraocular lens Clareon (IOL; model SY60CL; Alcon Vision LLC) at 3 months after the surgery. Read more about this study

Who is it for?
Ages 45 to 80 yearsHealthy volunteers can take part
Conditions the study is for
Intraocular Lens
What is being tested?
Monofocal intraocular lens Clareon (Alcon LLC)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
100 participants
Where
3 sitesCzechia
Study dates
1 Oct 2022to 1 Aug 2023
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 45 to 80 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • presence of cataract in both eyes
  • no other ocular pathology affecting visual acuity
  • bilateral phacoemulsification cataract surgery was arranged for both eyes
  • corneal astigmatism up to 0,5 cylinder (measured by IOL Master biometry)
  • dioptric power of both selective lens within 1,5 D range in one patient
  • selecting IOL power between 15 D and 28 D power range

Who cannot join

  • complicated cataract
  • corneal opacities or irregularities
  • amblyopia
  • anisometropia
  • coexisting ocular pathologies
  • glaucoma
  • history of ocular surgery
  • refusal or unable to maintain follow-up

Trial locations and contacts

3 sites in 1 country.

Andrea Janekova, MD contact

+420775727002

janekovaandrea@gmail.com

Pavel Studeny, MD contact

+420775555342

StudenyPavel@seznam.cz

Czechia3 sites, 3 recruiting
  • Somich Eye Clinic

    Karlovy Vary, 36001

    Pavel Studeny, MD, 775555342, StudenyPavel@seznam.cz

    Recruiting
  • Eye Center Prague

    Prague, Czech Republic, 11000

    Andrea Janekova, MD, +420775727002, janekovaandrea@gmail.com

    Recruiting
  • Faculty hospital Kralovske Vinohrady

    Prague, Czech Republic, 11000

    Andrea Janekova, MD, +420775727002, janekovaandrea@gmail.com

    Recruiting

Other trials in Czechia

About this study

To get the visual outcomes for distance and intermediate and binocular defocus curve in patients with implanted monofocal intraocular lens Clareon (IOL; model SY60CL; Alcon Vision LLC) at 3 months after the surgery.

Read the detailed description

The goal of refractive cataract surgery is to remove the opacity, or cataract and to produce the desired refractive outcome. In most cases, the desired outcome is an emmetropic eye, or an eye that sees 20/20 Snellen for distance vision post-surgery with the implant of a monofocal IOL. This, however, does not offer much in the way of intermediate and near vision. The increased desire for simultaneous distance, intermediate and near vision has increased the popularity of multifocal IOLs (MIOLs). However MIOLs provide visual acuity for all distances, they has occurence of optical phenomena such as glare and halo and lower contrast sensitivity. Extended depth of focus (EDOF) lens should provide distance vision as good as monofocal lens and intermediate vision better than monofocal but without or with less appearance of optical phenomenon or decreased contrast sensitivity.

This study is prospective, multi-center, conducted from 10/2022 to 08/2023 in the Ophthalmology department of Faculty Hospital Kralovske Vinohrady in Prague, in Eye Center Prague and Eye Clinic SOMICH (Karlovy Vary). The research protocol was explained to all participants and informed consent was signed before enrolling patient to the study. The study was approved by the Ethics Committee of Faculty Hospital Kralovske Vinohrady and will enrolled up to 100 patients with presence of cataract in both eyes.

Bilateral clear corneal phacoemulsification and IOL implantation is performed by two experienced surgeon using the same technique in both eyes. The surgical process involved topical anesthesia, superior 3-step clear corneal incision (2,2mm), 5,0mm curvilinear capsulorhexis, phacoemulsification, bilateral irrigation- aspiration and implantation of monofocal aspheric intraocular lens (Clareon Alcon vision LLC).

Patients are scheduled for visit at 3 months after the surgery.

Being tested
Monofocal intraocular lens Clareon (Alcon LLC)
Keywords
intraocular lens, monofocal lens, intermediate visual acuity

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Monofocal intraocular lens Clareon (Alcon LLC)Device

    monofocal aspheric lens implanted in eyes of patient during routine cataract surgery

Study groups in NCT05697978
Study groupRoleWhat they receive
Monofocal lensOtherEyes of patients with implanted monofocal aspheric lens Clareon (Alcon LLC)
Receives: Device: Monofocal intraocular lens Clareon (Alcon LLC)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Monocular corrected Distance Visual Acuity (CDVA)

    Monocular corrected distance visual acuity (CDVA) is measured at 4 m using an ETDRS (Early Treatment Diabetic Retinopathy Study) illumination cabinet (Precision Vision) under photopic conditions.

    Measured: 3 months

  2. Binocular corrected Distance Visual Acuity (CDVA)

    Binocular corrected distance visual acuity (CDVA) is measured at 4 m using an ETDRS (Early Treatment Diabetic Retinopathy Study) illumination cabinet (Precision Vision) under photopic conditions.

    Measured: 3 months

  3. Monocular uncorrected intermediate visual acuity (UIVA)

    Monocular intermediate visual acuity is measured using printed ETDRS charts for distance of 66cm

    Measured: 3 months

  4. Binocular uncorrected intermediate visual acuity (UIVA)

    Binocular intermediate visual acuity is measured using printed ETDRS charts for distance of 66cm

    Measured: 3 months

  5. Monocular distance corrected intermediate visual acuity (DCIVA)

    Monocular distance corrected intermediate visual acuity is measured using printed ETDRS charts for distance of 66cm

    Measured: 3 months

  6. Binocular distance corrected intermediate visual acuity (DCIVA)

    Binocular distance corrected intermediate visual acuity is measured using printed ETDRS charts for distance of 66cm

    Measured: 3 months

Secondary outcomes (1)
  1. Binocular defocus curve

    A defocus curve that measures visual acuity should be obtained by using the best corrected distance refraction and then defocusing the image in 0.5 increments from +1.5 to -3.0 diopter with spherical plus and spherical minus trial lenses (i.e.,+1.5 D, +1.0 D, +0.5 D, 0.00 D, -0.5 D, -1.00 D, . . . ,-2.50 D) with visual acuity recorded at each change in correction.

    Measured: 3 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted26 Jan 2023
  2. Study start1 Oct 2022
  3. Primary completion1 May 2023 (estimated)
  4. Study completion1 Aug 2023 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Model description
each patient in group received monofocal intraocular lens in both eyes
Masking
None (open label)
Enrolment
100 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05697978
Sponsor's protocol ID
CZ-001
Acronym
CLAINT
Status last verified
Feb 2023
First submitted
15 Jan 2023
Last updated
23 Feb 2023
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Lehmann R, Maxwell A, Lubeck DM, Fong R, Walters TR, Fakadej A. Effectiveness and Safety of the Clareon Monofocal Intraocular Lens: Outcomes from a 12-Month Single-Arm Clinical Study in a Large Sample. Clin Ophthalmol. 2021 Apr 20;15:1647-1657. doi: 10.2147/OPTH.S295008. eCollection 2021.

    PubMed 33907378
  • Werner L, Thatthamla I, Ong M, Schatz H, Garcia-Gonzalez M, Gros-Otero J, Canones-Zafra R, Teus MA. Evaluation of clarity characteristics in a new hydrophobic acrylic IOL in comparison to commercially available IOLs. J Cataract Refract Surg. 2019 Oct;45(10):1490-1497. doi: 10.1016/j.jcrs.2019.05.017. Epub 2019 Aug 6.

    PubMed 31399323
  • Bala C, Poyales F, Guarro M, Mesa RR, Mearza A, Varma DK, Jasti S, Lemp-Hull J. Multicountry clinical outcomes of a new nondiffractive presbyopia-correcting IOL. J Cataract Refract Surg. 2022 Feb 1;48(2):136-143. doi: 10.1097/j.jcrs.0000000000000712.

    PubMed 34288635

Questions about this trial

What is this clinical trial studying?

A study testing Monofocal intraocular lens Clareon (Alcon LLC) in people with Intraocular Lens, run by Faculty Hospital Kralovske Vinohrady at 3 sites in Czechia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 23 Feb 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 3 sites in Czechia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Andrea Janekova, MD (+420775727002, janekovaandrea@gmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Monocular corrected Distance Visual Acuity (CDVA) (time frame: 3 months). The study lists 6 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05697978, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 23 Feb 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in